TRIM-TEX 093V Fire Rated Expansion Installation Guide

June 15, 2024
TRIM-TEX

TRIM-TEX 093V Fire Rated Expansion Installation Guide

Fire Rated 093V Expansion

Building out fire-rated control joints on wall assemblies using traditional methods is costly and time consuming. Our fire rated 093X-V expansion bead revolutionizes this process.
Integrated intumescent tape rated for 1 and 2 hours, and the flexible bead accommodates up to ⁄8” in building movement.

Installation Guide

Before Installation:

Snap chalk lines as a guide. Measure, cut and dry fit the bead.

Step 1:

Coat both the bead and drywall with Trim-Tex 847 Spray Adhesive.

Step 2:

Press the bead in place, applying pressure to the mud legs.

Step 3:

Staple every 6”-8” using ½” staples.

Step 4:

Finish with drywall compound.

Step 5:

Remove tear-off strips prior to sanding.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TRIM-TEX User Manuals

Related Manuals