WEVER DUCRE PB19-010-572-00_v2 STATION Outdoor Wall LED Light Installation Guide
- June 15, 2024
- WEVER DUCRE
Table of Contents
PB19-010-572-00_v2 STATION Outdoor Wall LED Light
Installation Guide
PB19-010-572-00_v2 STATION Outdoor Wall LED Light
DIMENSIONS
MOUNTING INSTRUCTION
Remove the mounting base from the luminaire by loosening the side screws and
mount it on the wall with screws (screws are not included).
POWER CONNECTION Please use a matching grommet based on the used 220-240V cable
and the corresponding type in the overview table.
Push the grommet into the back plate.| Pull the cable through the back plate.| Mount the back plate on the wall.
Fix the luminaire to the mounting base with the socket screws. Mounting base: grommets:
use pin to make hole not a knife| | |
---|---|---|---
CABLE| | |
TYPE| ROUND
HO5RN-F
HO7RN8-F
HO7RN-F| ROUND
HO5RN-F| ROUND
OUTSIDE 0| min 6.8mm
max 8.9mm| min 5mm
max 6.8mm| min 1.5mm
max 2.6mm
CONDUCTION SECTION| 2or3x 0.75mm2
2or3x 1.0mm2
2or3x 1.5mm2| 2or3x 0.75mm2
2x 1.0mm2| 0.75mm2
1.5mm2
DISMOUNTING AND RECYCLING INSTRUCTIONS Light source & driver
- Loosen the side screws and remove the lamp housing from the mounting base.
- Loosen the wires to remove the driver.
- Break the glass.
- Take out the reflector and unscrew the holder to remove the light source.
The driver can be replaced by the end user.
The light source is not replaceable.
This luminaire contains a light source with the energy class F.