ALPINE HEARING PROTECTION M-L Alpine Sleep Deep Instruction Manual
- June 15, 2024
- ALPINE HEARING PROTECTION
Table of Contents
SLEEP DEEP
SLEEP COMFORTABLY EVERY NIGHT
M-L Alpine Sleep Deep
Watch the instructions for a comfortable night’s sleep
alpinehearingprotection.com/pages/sleepdeep-
fittingATTENUATION DATA Alpine SleepDeep
Tested according to EN 352-2: 2020
1 | Frequency Hz | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
---|---|---|---|---|---|---|---|---|---|
2 | Mean Attenuation dB | 24,4 | 25,9 | 24,1 | 25,7 | 26,2 | 32,0 | 37,9 | 42,4 |
3 | Standard Deviation dB | 3,9 | 3,8 | 4,4 | 4,9 | 4,5 | 5,0 | 4,3 | 6,7 |
4 | Assumed Protection in dB (APV) | 20,5 | 22,1 | 19,7 | 20,8 | 21,7 | 27, 0 | 33,6 |
35,7
SNR, H-, M- and L-values
| | SNR| H| M| L
---|---|---|---|---|---
2| Mean Attenuation dB| 29,8| 31,4| 26,9| 25,5
3| Standard Deviation dB| 3,3| 3,6| 3,9| 3,9
4| Value dB| 27| 28| 23| 22
Size=M/L
H=28 M=23 L=22
SNR=27
Noise Reduction Rating The Noise Reduction Rating shows
the range of protection expected from this protector in normal usage. The
lower number is the amount of protection possible for most users (80%) to
achieve or exceed. The higher number is the amount possible for a few
motivated proficient users (20%) to achieve or exceed. Higher numbers denote
greater protection.
Alpine Hearing Protection
Soesterberg, The Netherlands
Alpine SleepDeep
Federal law prohibits removal of this label prior to purchase Label required
by U.S.
EPA Regulation
40 CFR Part 211, Subpart B
The hearing protector is intended to protect the wearer from hazardous noise levels. The wearer should ensure that the earplugs are fi tted, adjusted and maintained in accordance with this Instruction Manual. Any other uses are not intended and therefore not allowed. Always wear the earplugs when in a noisy environment, without interruption. Slightly pull up your ear and with your other hand insert the earplug into the ear, until the protector fi ts snugly. Do not place the earplug too deep in the ear. Improper fi t, improper use or failure to follow the instructions of this device will decrease noise reduction eff ectiveness, increase the risk of hearing damage and aff ect the lifespan of the reusable earplugs. Alpine Hearing Protection is not liable for any damage arising from misuse. Check the working order of the earplugs regularly and store them in the original, clean packaging. Clean the earplugs regularly with mild soap and lukewarm water. Dry off after cleaning. The reusable earplugs can be used approximately 100 times. Sudden or rapid removal of hearing protection may cause damage to the eardrum. When this device is worn as directed, the level of noise entering a person’s ear is approximated by the diff erences between the A-weighted environmental noise level and the lesser and greater NRRs. Caution: For predominantly low frequency noise environments in which the diff erence in the measured C-weighted and A-weighted noise levels (dBCdBA) exceeds 3 dB, the user is directed to the enclosed graph of the variability of noise reduction with noise spectra to determine the level of protection. This product may be adversely aff ected by certain chemical substances. Further information should be sought from the manufacturer. Hereby, Alpine Hearing Protection, declares that the hearing protector SleepDeep is in compliance with the PPE regulation (EU) 2016/425. The full text of the EU Declaration of Conformity is available at the following internet address: www.alpine.eu/doc
Alpine Hearing Protection
Amersfoortsestraat 70-d
3769 AL Soesterberg
The Netherlands
T +31-(0)346-333350
www.alpine.eu
Version 022-02 CE certified and monitored by PZT GmbH,
Bismarckstr. 264B, 26389 Wilhelmshaven, #1974, Germany
References
- EU Declarations of Conformity – Alpine Hearing Protection
- SleepDeep fitting – Alpine Hearing Protection
- Alpine Hearing Protection - Nr.1 Earplugs for every Age and Situation
- Alpine Hearing Protection - Nr.1 Earplugs for every Age and Situation
- EU Declarations of Conformity – Alpine Hearing Protection
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>