RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration User Guide

June 15, 2024
RADWAG

AP-12.5Y Automatic Device For Multi Channel Pipette Calibration
User Guide

AP-12.5Y Automatic Device For Multi Channel Pipette Calibration

To view the complete User Manual, go to the website or scan the QR code:

https://radwag.com/en/manuals/1ZS

CONTENT
AP-12.5Y | AP-12.1.5YRADWAG AP-12.5Y Automatic Device For Multi Channel
Pipette Calibration - parts*The plug type may vary by country.

RECOMMENDATIONS AND WARNINGS

Operate the device in a room where the temperature ranges between 10 – 40 °C (50 – 104 °F) and where the relative humidity is below 80%.
The temperature change must occur gradually and slowly.
The use of an anti-vibration table is recommended for obtaining stable and repeatable weighing results.

RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration -
heat Sourecs

Place the balance away from heat sources. Avoid exposing the balance to the sunlight.| Avoid exposing the balance to a magnetic field. Do not weigh magnetic substances.| Do not place the balance in a hazardous
area. Do not weigh explosive or flammable materials.
RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration -
balance

Make sure that the balance is placed on an even surface.| Do not place the balance on an unstable surface exposed to shocks and vibrations.| Do not place the balance in a hazardous
area. Do not weigh explosive or flammable materials.

COMPONENTS ASSEMBLY

AP-12.5Y | AP-12.1.5YRADWAG AP-12.5Y Automatic Device For Multi Channel
Pipette Calibration - COMPONENTS ASSEMBLY

PREPARING FOR WORK

Place the device at the workstation, wait until it reaches room temperature.
4.1. Temperature Stabilization Prior to switching the device on, let it reach room temperature (estimated stabilization time: up to 8 hours).  Connect the power supply cable to the DC socket on the back of the balance or on the back of the terminal. Connect the power supply to the mains.
Do not connect the balance and the terminal to the power supply at the same time.
4.2. Switching the Balance On The balance switches on automatically when connected to the mains. If the balance is manually switched off using the top menu, it must be switched on using the button underneath the display housing on the left.RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - automatic levellingThe balance with automatic levelling starts the program and the levelling process runs automatically.RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - displayedWhen auto levelling is complete, the home screen is displayed.
4.3. Balance LevellingRADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - status pictogram Press the level status pictogram.RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - control panelThe control panel of the levelling function is displayed. To level the balance, turn its feet; keep turning until the pictogram on the screen is in the central position. Press to return to the home screen.

HOME SCREEN

information about the currently used working mode, logged-in operator, date, time, active connection with a computer. RADWAG AP-12.5Y Automatic Device
For Multi Channel Pipette Calibration - HOME SCREEN

 BASIC OPERATIONS

6.1. Internal AdjustmentRADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - Internal AdjustmentRADWAG AP-12.5Y Automatic Device
For Multi Channel Pipette Calibration - Internal adjustment
14 6.2. ZeroingRADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - Zeroing Make sure that the weighing pan is empty and press “Zeroing” button.RADWAG
AP-12.5Y Automatic Device For Multi Channel Pipette Calibration - Zeroing
1The balance has been zeroed.
6.3. Taring RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - TaringWith loaded weighing pan: upon stabilization of the weighing result, press “Tare” button.RADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - Taring 1The balance has been tared.
6.4. Working Modes
Slide down the top menu, press “Working modes” pictogram to display the list of available working modes.RADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - Working modes

Weighing SQC
Parts counting Formulations
Checkweighing Peak hold
Dosing Statistics
Percent weighing Optional:
Pipette calibration PGC
Density Comparator
Differential weighing Animal weighing Mass control

6.5. Unit Selection
Press the current mass unit pictogram to display the list of available units.
RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration -
Unit Selection

Gram [g] Singapore tael [tls]
Miligram [mg] Taiwanese tael [tlt]
Kilogram [kg] Chinese tael [tlc]
Carat [c] Momme [m]
Pound [lb] Grain [gr]
Ounce [oz] Tical [ti]
Troy ounce [ozt] Newton [N]
Pennyweight [dwt] Mesghal [msg]
Hong Kong Tael [tlh]

 SETTINGS

Some balance settings are available only for the Administrator.
Prior to the balance parameters setup, log in as the Administrator.
7.1. Administrator LoginRADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - Administrator Login Slide down the top menu and press „Log in”.RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - Administrator Login 1Select „Admin” from the menu.![RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration

  • Enter password](https://manuals.plus/wp-content/uploads/2023/12/RADWAG-AP-12 .5Y-Automatic-Device-For-Multi-Channel-Pipette-Calibration-Enter- password.png)RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - logged 7.2. Operator Settings
    Prior to operators configuration, log in as the Administrator (see section 9.1). ![RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration
  • enter Menu](https://manuals.plus/wp-content/uploads/2023/12/RADWAG-AP-12.5Y- Automatic-Device-For-Multi-Channel-Pipette-Calibration-enter-Menu.png)Press to enter Menu and select „Operators”.RADWAG AP-12.5Y Automatic Device For Multi
Channel Pipette Calibration - necessary fieldsPress add button and fill in the necessary fields for a new operator.RADWAG AP-12.5Y Automatic Device For
Multi Channel Pipette Calibration - Operator Settings 7.3. Proximity Sensors Setup
    You can assign a function of your choice to each proximity sensor. In addition, you can assign various functions to the same sensor in different working modes. See  the exemplary procedure for sensors configuration for the „Weighing” mode.RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette
Calibration - Sensors Setup Select a respective sensor (right or left) from the list. Select a function to be assigned to the sensor.

CONNECTING PERIPHERALS

RADWAG AP-12.5Y Automatic Device For Multi Channel Pipette Calibration -
CONNECTING PERIPHERALSWi-Fi® is a registered trademark of Wi-Fi Alliance.
*A USB to RS232 converter must be used for proper connection.

CLEANING AND MAINTENANCE

9.1. Guidelines and Precautions Prior to cleaning it is necessary to disconnect the device from the mains! Remove the plug from the outlet and disconnect all cables. Use soft cloth made of either natural or synthetic fibers exclusively. Avoid using stiff or hard fabric, as this may cause scratches on the surface!

Apply the cleanser to the cloth. Remember not to apply the cleanser directly onto the device!
Do not use aggressive cleaning agents (e.g. solvents, chlorine preparations, corrosive chemicals, bleach).
Use neither sharp-structured nor scrubbing-purposed substances.
Make sure that neither dust nor liquid gets inside the weighing system (device inside).
9.2. Cleaning Instructions
If it is necessary to disassemble the weighing chamber, follow the instructions in section 11.3.

  • GLASS PANES AND COMPONENTS can be cleaned using window cleaner.
  • WEIGHING PANS AND STAINLESS STEEL OR ALUMINIUM COMPONENTS can be cleaned using a cloth slightly soaked in a solution of water and gentle cleanser (e.g. soap or dishwashing liquid).
  • OPERATION PANEL AND HOUSING can be cleaned using a cloth slightly soaked in a solution of water and gentle cleanser (e.g. soap or dishwashing liquid).
  •  Dry sample leftovers can be removed using either a brush or a handheld vacuum cleaner.
  • Clean components can be dried using a soft cloth or a dust-free paper towel. With this, the remaining moisture will be absorbed.
  •  Install all the components, providing they are completely dry.