CHAUVET PROFESSIONAL onAir Panel 3 IP RGBWW LED Installation Guide
- June 15, 2024
- Chauvet Professional
Table of Contents
onAir Panel 3 IP RGBWW LED
PHOTOMETRICS REPORT
Installation Guide
Introduction
Testing Process
Total Illuminance Measurements
Illuminance is measured using the Viso Systems LabSpion®, which takes multiple
measurements across a light beam to calculate the total delivered lumens,
beam, and field of a product. These values can be described as the empirical
output of the product as it projects from the lens or lenses. All photometric
data contained in this report are obtained from the actual illuminance of the
tested Chauvet light source and are never theoretical values derived from
calculations.
Testing Lab Equipment and Process
The Chauvet headquarters in Sunrise, Florida has a climate- and light-
controlled photometric testing laboratory where Chauvet products are analyzed
and photometric data are measured using the Viso Systems LabSpion® light
measurement solution.
This system includes a spectrometer sensor, which measures the precise light
and color output of the fixture, and a two-axis goniometer, which rotates the
product to allow for multi-angle and multidirectional measurement. The Viso
Light Inspector software then collects and summarizes the data. From the data
gathered, the software can also measure the beam and field angles, accurate
color temperature, color quality, and illuminance at multiple distances. The
custom-built, Chauvet-specific template presents this information in the
photometric and chromaticity reports that follow.
IES (Illuminating Engineering Society) files, an industry-standard file
format, are also generated from each test for easy distribution of photometric
data.
Several light meters are also used for specific products or to recheck for
precision. Accuracy is verified using one or more of the devices listed below:
- Sekonic SpectroMaster C-700-U
- EXTECH HD450 Datalogging Heavy Duty Light Meter
- Asensetek Essence Lighting Passport
To ensure accurate measurements in every photometric or chromaticity test, Chauvet routinely calibrates the LabSpion® system every six months as recommended by Viso Systems.
Photometrics & Chromaticity Reports
Photometric & Chromaticity Report
onAir Panel 3 IP: Medium Filter – Full Power
Report Summary
Measurements
Fixture Output: 6744 lm
Fixture Peak: 2901 cd
Fixture Efficacy: 41 lm/W
Intensity @ 5m: 116 lux
Color Temperature: 5437 K
CRI: 68.6
CRI R9 Value: -30.2
CQS: 86.8
TLCI: 70
TM-30 Rf: 82.4
TM-30 Rg: 115.7
Beam Angle (50%): 92.5°
Field Angle (10%): 152.2°
Cutoff Angle (3%): 168.6°
Conditions
AC Supply: 117 V, 60 Hz
Power: 165.73 W
Current: 1.41 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/9/2023 to LM-63-2002 Standards.
Overall Measurement
onAir Panel 3 IP: Medium Filter – Full Power
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance| 1m| 2m| 3m| 4m| 5m| 6m| 7m|
8m| 9m| 10m
---|---|---|---|---|---|---|---|---|---|---
Lux| 2890| 723| 321| 181| 116| 80| 59| 45| 36| 29
Distance| 11m| 12m| 13m| 14m| 15m| 16m|
17m| 18m| 19m| 20m
Lux| 24| 20| 17| 15| 13| 11| 10| 9| 8| 7
Distance| 3.3ft| 6.6ft| 9.8ft| 13.1ft| 16.4ft|
19.7ft| 23ft| 26.2ft| 29.5ft| 32.8ft
FC| 268| 67| 30| 17| 11| 7| 5| 4| 3| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft|
49.2ft| 52.5ft| 55.8ft| 59.1ft| 62.3ft| 65.6ft
FC| 2| 2| 2| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5437 K | 0.334 | 0.315 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0180| 0.315| 0.218
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
68.6| -30.2| 86.8
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
70| 82.4| 115.7
TM-30 Details
onAir Panel 3 IP: Medium Filter – 3200K
Report Summary
Measurements
Fixture Output: 5704 lm
Fixture Peak: 2463 cd
Fixture Efficacy: 50 lm/W
Intensity @ 5m: 98 lux
Color Temperature: 3218 K
CRI: 94.8
CRI R9 Value: 93.4
CQS: 93.9
TLCI: 86
TM-30 Rf: 92.9
TM-30 Rg: 103.6
Beam Angle (50%): 92°
Field Angle (10%): 152.1°
Cutoff Angle (3%): 168.4°
Conditions
AC Supply: 119 V, 60 Hz
Power: 115.9 W
Current: 0.972 A
Power Factor: 0.99
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/9/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2460 | 615 | 273 | 154 | 98 | 68 | 50 | 38 | 30 | 25 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 20 | 17 | 15 | 13 | 11 | 10 | 9 | 8 | 7 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 229| 57| 25| 14| 9| 6| 5| 4| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3218 K | 0.423 | 0.400 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0003| 0.400| 0.243
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
94.8| 93.4| 93.9
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
86| 92.9| 103.6
TM-30 Details
onAir Panel 3 IP: Medium Filter – 4000K
Report Summary
Measurements
Fixture Output: 5955 lm
Fixture Peak: 2564 cd
Fixture Efficacy: 48 lm/W
Intensity @ 5m: 102 lux
Color Temperature: 4007 K
CRI: 95.1
CRI R9 Value: 97.3
CQS: 95.4
TLCI: 88
TM-30 Rf: 92.2
TM-30 Rg: 103.4
Beam Angle (50%): 92.3°
Field Angle (10%): 152.1°
Cutoff Angle (3%): 168.5°
Conditions
AC Supply: 120 V, 60 Hz
Power: 124.37 W
Current: 1.04 A
Power Factor: 0.99
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2561 | 640 | 285 | 160 | 102 | 71 | 52 | 40 | 32 | 26 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 21 | 18 | 15 | 13 | 11 | 10 | 9 | 8 | 7 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 238| 59| 26| 15| 10| 7| 5| 4| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
4007 K | 0.380 | 0.377 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0001| 0.377| 0.225
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
95.1| 97.3| 95.4
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
88| 92.2| 103.4
TM-30 Details
onAir Panel 3 IP: Medium Filter – 5600K
Report Summary
Measurements
Fixture Output: 6332 lm
Fixture Peak: 2725 cd
Fixture Efficacy: 46 lm/W
Intensity @ 5m: 109 lux
Color Temperature: 5609 K
CRI: 94.9
CRI R9 Value: 96.1
CQS: 94.6
TLCI: 93
TM-30 Rf: 91.4
TM-30 Rg: 103.8
Beam Angle (50%): 92.4°
Field Angle (10%): 152.1°
Cutoff Angle (3%): 168.5°
Conditions
AC Supply: 117 V, 60 Hz
Power: 138.8 W
Current: 1.18 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2722 | 680 | 302 | 170 | 109 | 76 | 56 | 43 | 34 | 27 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 22 | 19 | 16 | 14 | 12 | 11 | 9 | 8 | 8 | 7 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 253| 63| 28| 16| 10| 7| 5| 4| 3| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5609 K | 0.330 | 0.338 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0038| 0.338| 0.206
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
94.9| 96.1| 94.6
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
93| 91.4| 103.8
TM-30 Details
onAir Panel 3 IP: Medium Filter – Red Only
Report Summary
Measurements
Fixture Output: 1136 lm
Fixture Peak: 493 cd
Fixture Efficacy: 28 lm/W
Intensity @ 5m: 20 lux
Color Temperature: 0 K
CRI: 0.0
CRI R9 Value: 0.0
CQS: 0.0
TLCI: n/a
TM-30 Rf: 0.0
TM-30 Rg: 0.0
Beam Angle (50%): 91.7°
Field Angle (10%): 151.5°
Cutoff Angle (3%): 168.4°
Conditions
AC Supply: 118 V, 60 Hz
Power: 45.27 W
Current: 0.383 A
Power Factor: 0.9
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/9/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 492 | 123 | 55 | 31 | 20 | 14 | 10 | 8 | 6 | 5 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 4 | 3 | 3 | 3 | 2 | 2 | 2 | 2 | 1 | 1 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 46| 11| 5| 3| 2| 1| 1| 1| 1| 0
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
0 K | 0.696 | 0.304 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
n/a| 0.304| 0.530
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
0.0| 0.0| 0.0
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
n/a| 0.0| 0.0
TM-30 Details
onAir Panel 3 IP: Medium Filter – Green Only
Report Summary
Measurements
Fixture Output: 2936 lm
Fixture Peak: 1242 cd
Fixture Efficacy: 38 lm/W
Intensity @ 5m: 50 lux
Color Temperature: 0 K
CRI: 0.0
CRI R9 Value: 0.0
CQS: 0.0
TLCI: n/a
TM-30 Rf: 0.0
TM-30 Rg: 0.0
Beam Angle (50%): 93.6°
Field Angle (10%): 152.8°
Cutoff Angle (3%): 169.8°
Conditions
AC Supply: 118 V, 60 Hz
Power: 79.48 W
Current: 0.674 A
Power Factor: 0.98
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/9/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 1241 | 310 | 138 | 78 | 50 | 34 | 25 | 19 | 15 | 12 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 10 | 9 | 7 | 6 | 6 | 5 | 4 | 4 | 3 | 3 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 115| 29| 13| 7| 5| 3| 2| 2| 1| 1
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 1| 1| 1| 1| 1| 0| 0| 0| 0| 0
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
0 K | 0.168 | 0.727 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
n/a| 0.727| 0.059
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
0.0| 0.0| 0.0
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
n/a| 0.0| 0.0
TM-30 Details
onAir Panel 3 IP: Medium Filter – Blue Only
Report Summary
Measurements
Fixture Output: 337 lm
Fixture Peak: 137 cd
Fixture Efficacy: 10 lm/W
Intensity @ 5m: 5 lux
Color Temperature: 0 K
CRI: 0.0
CRI R9 Value: 0.0
CQS: 0.0
TLCI: n/a
TM-30 Rf: 0.0
TM-30 Rg: 0.0
Beam Angle (50%): 95.8°
Field Angle (10%): 154.4°
Cutoff Angle (3%): 171.6°
Conditions
AC Supply: 119 V, 60 Hz
Power: 39.46 W
Current: 0.332 A
Power Factor: 0.86
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 137 | 34 | 15 | 9 | 5 | 4 | 3 | 2 | 2 | 1 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 13| 3| 1| 1| 1| 0| 0| 0| 0| 0
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 0| 0| 0| 0| 0| 0| 0| 0| 0| 0
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
onAir Panel 3 IP: Medium Filter – Blue Only
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
0 K | 0.149 | 0.033 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
n/a| 0.033| 0.192
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
0.0| 0.0| 0.0
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
n/a| 0.0| 0.0
TM-30 Details
onAir Panel 3 IP: Medium Filter – White Only
Report Summary
Measurements
Fixture Output: 4537 lm
Fixture Peak: 1965 cd
Fixture Efficacy: 57 lm/W
Intensity @ 5m: 78 lux
Color Temperature: 3087 K
CRI: 82.5
CRI R9 Value: 3.8
CQS: 82.0
TLCI: 67
TM-30 Rf: 85.0
TM-30 Rg: 95.8
Beam Angle (50%): 91.9°
Field Angle (10%): 151.9°
Cutoff Angle (3%): 168.2°
Conditions
AC Supply: 118 V, 60 Hz
Power: 82.01 W
Current: 0.695 A
Power Factor: 0.98
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 1962 | 490 | 218 | 123 | 78 | 54 | 40 | 31 | 24 | 20 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 16 | 14 | 12 | 10 | 9 | 8 | 7 | 6 | 5 | 5 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 182| 46| 20| 11| 7| 5| 4| 3| 2| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 1| 1| 1| 1| 1| 1| 1| 1| 0
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3087 K | 0.431 | 0.402 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0001| 0.402| 0.248
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
82.5| 3.8| 82.0
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
67| 85.0| 95.8
TM-30 Details
onAir Panel 3 IP: Light Filter – Full Power
Report Summary
Measurements
Fixture Output: 7268 lm
Fixture Peak: 3380 cd
Fixture Efficacy: 44 lm/W
Intensity @ 5m: 135 lux
Color Temperature: 5619 K
CRI: 69.4
CRI R9 Value: -31.3
CQS: 87.0
TLCI: 71
TM-30 Rf: 82.6
TM-30 Rg: 115.1
Beam Angle (50%): 88.5°
Field Angle (10%): 144.8°
Cutoff Angle (3%): 163.5°
Conditions
AC Supply: 118 V, 60 Hz
Power: 164.2 W
Current: 1.39 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3377 | 844 | 375 | 211 | 135 | 94 | 69 | 53 | 42 | 34 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 28 | 23 | 20 | 17 | 15 | 13 | 12 | 10 | 9 | 8 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 314| 78| 35| 20| 13| 9| 6| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5619 K | 0.330 | 0.313 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0173| 0.313| 0.217
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
69.4| -31.3| 87.0
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
71| 82.6| 115.1
TM-30 Details
onAir Panel 3 IP: Light Filter – 3200K
Report Summary
Measurements
Fixture Output: 7031 lm
Fixture Peak: 3293 cd
Fixture Efficacy: 51 lm/W
Intensity @ 5m: 132 lux
Color Temperature: 3234 K
CRI: 86.7
CRI R9 Value: 69.8
CQS: 87.5
TLCI: 76
TM-30 Rf: 89.5
TM-30 Rg: 104.8
Beam Angle (50%): 88.1°
Field Angle (10%): 144.5°
Cutoff Angle (3%): 163.4°
Conditions
AC Supply: 119 V, 60 Hz
Power: 137.24 W
Current: 1.15 A
Power Factor: 0.99
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3288 | 822 | 365 | 206 | 132 | 91 | 67 | 51 | 41 | 33 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 27 | 23 | 19 | 17 | 15 | 13 | 11 | 10 | 9 | 8 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 305| 76| 34| 19| 12| 8| 6| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3234 K | 0.426 | 0.410 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0040| 0.410| 0.241
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
86.7| 69.8| 87.5
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
76| 89.5| 104.8
TM-30 Details
onAir Panel 3 IP: Light Filter – 4000K
Report Summary
Measurements
Fixture Output: 6871 lm
Fixture Peak: 3213 cd
Fixture Efficacy: 52 lm/W
Intensity @ 5m: 128 lux
Color Temperature: 4010 K
CRI: 93.4
CRI R9 Value: 91.3
CQS: 92.5
TLCI: 85
TM-30 Rf: 91.5
TM-30 Rg: 102.7
Beam Angle (50%): 88.3°
Field Angle (10%): 144.6°
Cutoff Angle (3%): 163.4°
Conditions
AC Supply: 119 V, 60 Hz
Power: 133.78 W
Current: 1.12 A
Power Factor: 0.99
This data sheet conforms to American National Standard E1.9 – 2007 (R2017). All data was measured and calculated by a Viso Systems LabSpion Goniometer at the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002 Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3210 | 802 | 357 | 201 | 128 | 89 | 66 | 50 | 40 | 32 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 27 | 22 | 19 | 16 | 14 | 13 | 11 | 10 | 9 | 8 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 298| 75| 33| 19| 12| 8| 6| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
4010 K | 0.385 | 0.393 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0061| 0.393| 0.222
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
93.4| 91.3| 92.5
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
85| 91.5| 102.7
TM-30 Details
Report Summary
Measurements
Fixture Output: 7617 lm
Fixture Peak: 3554 cd
Fixture Efficacy: 48 lm/W
Intensity @ 5m: 142 lux
Color Temperature: 5661 K
CRI: 92.7
CRI R9 Value: 81.4
CQS: 92.8
TLCI: 87
TM-30 Rf: 90.8
TM-30 Rg: 104.1
Beam Angle (50%): 88.4°
Field Angle (10%): 144.8°
Cutoff Angle (3%): 163.4°
Conditions
AC Supply: 119 V, 60 Hz
Power: 159.05 W
Current: 1.33 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3549 | 887 | 394 | 222 | 142 | 99 | 72 | 55 | 44 | 35 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 29 | 25 | 21 | 18 | 16 | 14 | 12 | 11 | 10 | 9 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 330| 82| 37| 21| 13| 9| 7| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5661 K | 0.329 | 0.354 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0049| 0.354| 0.199
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
92.7| 81.4| 92.8
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
87| 90.8| 104.1
TM-30 Details
Report Summary
Measurements
Fixture Output: 6311 lm
Fixture Peak: 2348 cd
Fixture Efficacy: 39 lm/W
Intensity @ 5m: 94 lux
Color Temperature: 5236 K
CRI: 66.7
CRI R9 Value: -36.1
CQS: 87.6
TLCI: 73
TM-30 Rf: 82.2
TM-30 Rg: 116.8
Beam Angle (50%): 106.2°
Field Angle (10%): 155.3°
Cutoff Angle (3%): 169.5°
Conditions
AC Supply: 119 V, 60 Hz
Power: 164.29 W
Current: 1.39 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2345 | 586 | 261 | 147 | 94 | 65 | 48 | 37 | 29 | 23 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 19 | 16 | 14 | 12 | 10 | 9 | 8 | 7 | 6 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 218| 54| 24| 14| 9| 6| 4| 3| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5236 K | 0.337 | 0.307 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0241| 0.307| 0.224
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
66.7| -36.1| 87.6
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
73| 82.2| 116.8
TM-30 Details
Report Summary
Measurements
Fixture Output: 6227 lm
Fixture Peak: 2317 cd
Fixture Efficacy: 45 lm/W
Intensity @ 5m: 93 lux
Color Temperature: 3221 K
CRI: 86.4
CRI R9 Value: 70.4
CQS: 86.1
TLCI: 74
TM-30 Rf: 89.1
TM-30 Rg: 104.3
Beam Angle (50%): 106°
Field Angle (10%): 155.2°
Cutoff Angle (3%): 169.1°
Conditions
AC Supply: 119 V, 60 Hz
Power: 138.95 W
Current: 1.17 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2315 | 579 | 257 | 145 | 93 | 64 | 47 | 36 | 29 | 23 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 19 | 16 | 14 | 12 | 10 | 9 | 8 | 7 | 6 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 215| 54| 24| 13| 9| 6| 4| 3| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 1| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3221 K | 0.429 | 0.414 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0052| 0.414| 0.241
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
86.4| 70.4| 86.1
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
74| 89.1| 104.3
TM-30 Details
Report Summary
Measurements
Fixture Output: 5997 lm
Fixture Peak: 2236 cd
Fixture Efficacy: 45 lm/W
Intensity @ 5m: 89 lux
Color Temperature: 3975 K
CRI: 93.1
CRI R9 Value: 91.1
CQS: 92.3
TLCI: 84
TM-30 Rf: 91.4
TM-30 Rg: 102.8
Beam Angle (50%): 106°
Field Angle (10%): 155.1°
Cutoff Angle (3%): 169.4°
Conditions
AC Supply: 119 V, 60.1 Hz
Power: 135.22 W
Current: 1.14 A
Power Factor: 0.99
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2233 | 558 | 248 | 140 | 89 | 62 | 46 | 35 | 28 | 22 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 18 | 16 | 13 | 11 | 10 | 9 | 8 | 7 | 6 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 207| 52| 23| 13| 8| 6| 4| 3| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 1| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3975 K | 0.386 | 0.393 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0060| 0.393| 0.222
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
93.1| 91.1| 92.3
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
84| 91.4| 102.8
TM-30 Details
Report Summary
Measurements
Fixture Output: 6580 lm
Fixture Peak: 2450 cd
Fixture Efficacy: 41 lm/W
Intensity @ 5m: 98 lux
Color Temperature: 5604 K
CRI: 92.7
CRI R9 Value: 82.6
CQS: 92.7
TLCI: 87
TM-30 Rf: 90.8
TM-30 Rg: 104.0
Beam Angle (50%): 106.1°
Field Angle (10%): 155.2°
Cutoff Angle (3%): 169.1°
Conditions
AC Supply: 118 V, 60 Hz
Power: 159.31 W
Current: 1.35 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 2445 | 611 | 272 | 153 | 98 | 68 | 50 | 38 | 30 | 24 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 20 | 17 | 14 | 12 | 11 | 10 | 8 | 8 | 7 | 6 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 227| 57| 25| 14| 9| 6| 5| 4| 3| 2
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 2| 2| 1| 1| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5604 K | 0.330 | 0.356 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0052| 0.356| 0.200
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
92.7| 82.6| 92.7
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
87| 90.8| 104.0
TM-30 Details
Report Summary
Measurements
Fixture Output: 5788 lm
Fixture Peak: 3630 cd
Fixture Efficacy: 36 lm/W
Intensity @ 5m: 145 lux
Color Temperature: 5673 K
CRI: 70.4
CRI R9 Value: -29.4
CQS: 87.3
TLCI: 72
TM-30 Rf: 82.9
TM-30 Rg: 114.5
Beam Angle (50%): 70.2°
Field Angle (10%): 127.1°
Cutoff Angle (3%): 166.6°
Conditions
AC Supply: 119 V, 60 Hz
Power: 162.48 W
Current: 1.37 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/12/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3625 | 906 | 403 | 227 | 145 | 101 | 74 | 57 | 45 | 36 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 30 | 25 | 21 | 18 | 16 | 14 | 13 | 11 | 10 | 9 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 337| 84| 37| 21| 13| 9| 7| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5673 K | 0.329 | 0.314 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
-0.0163| 0.314| 0.216
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
70.4| -29.4| 87.3
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
72| 82.9| 114.5
TM-30 Details
Report Summary
Measurements
Fixture Output: 5985 lm
Fixture Peak: 3769 cd
Fixture Efficacy: 42 lm/W
Intensity @ 5m: 151 lux
Color Temperature: 3214 K
CRI: 85.9
CRI R9 Value: 70.6
CQS: 85.7
TLCI: 71
TM-30 Rf: 88.7
TM-30 Rg: 104.5
Beam Angle (50%): 69.9°
Field Angle (10%): 126.9°
Cutoff Angle (3%): 166.7°
Conditions
AC Supply: 117 V, 60 Hz
Power: 144.07 W
Current: 1.23 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/13/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3767 | 942 | 419 | 235 | 151 | 105 | 77 | 59 | 47 | 38 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 31 | 26 | 22 | 19 | 17 | 15 | 13 | 12 | 10 | 9 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 350| 87| 39| 22| 14| 10| 7| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 2| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
3214 K | 0.429 | 0.414 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0051| 0.414| 0.242
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
85.9| 70.6| 85.7
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
71| 88.7| 104.5
TM-30 Details
Report Summary
Measurements
Fixture Output: 5668 lm
Fixture Peak: 3558 cd
Fixture Efficacy: 42 lm/W
Intensity @ 5m: 142 lux
Color Temperature: 4053 K
CRI: 93.5
CRI R9 Value: 93.3
CQS: 92.1
TLCI: 84
TM-30 Rf: 91.4
TM-30 Rg: 102.6
Beam Angle (50%): 70.1°
Field Angle (10%): 127.3°
Cutoff Angle (3%): 166.9°
Conditions
AC Supply: 118 V, 60 Hz
Power: 136.06 W
Current: 1.15 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/13/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3555 | 889 | 395 | 222 | 142 | 99 | 73 | 56 | 44 | 36 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 29 | 25 | 21 | 18 | 16 | 14 | 12 | 11 | 10 | 9 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 330| 83| 37| 21| 13| 9| 7| 5| 4| 3
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 2| 2| 2| 1| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
4053 K | 0.383 | 0.394 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0070| 0.394| 0.220
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
93.5| 93.3| 92.1
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
84| 91.4| 102.6
TM-30 Details
Report Summary
Measurements
Fixture Output: 6244 lm
Fixture Peak: 3916 cd
Fixture Efficacy: 39 lm/W
Intensity @ 5m: 156 lux
Color Temperature: 5635 K
CRI: 92.5
CRI R9 Value: 81.4
CQS: 92.5
TLCI: 86
TM-30 Rf: 90.7
TM-30 Rg: 104.3
Beam Angle (50%): 70.2°
Field Angle (10%): 127.3°
Cutoff Angle (3%): 167°
Conditions
AC Supply: 118 V, 60 Hz
Power: 161.79 W
Current: 1.37 A
Power Factor: 1.0
This data sheet conforms to American National Standard E1.9 – 2007 (R2017).
All data was measured and calculated by a Viso Systems LabSpion Goniometer at
the Chauvet PD Optics Laboratory in Sunrise, FL on 6/13/2023 to LM-63-2002
Standards.
Overall Measurement
Beam Details
Beam Intensities from 1-20m (3.3-65.6ft)
Distance | 1m | 2m | 3m | 4m | 5m | 6m | 7m | 8m | 9m | 10m |
---|---|---|---|---|---|---|---|---|---|---|
Lux | 3912 | 978 | 435 | 245 | 156 | 109 | 80 | 61 | 48 | 39 |
Distance | 11m | 12m | 13m | 14m | 15m | 16m | 17m | 18m | 19m | 20m |
Lux | 32 | 27 | 23 | 20 | 17 | 15 | 14 | 12 | 11 | 10 |
Distance | 3.3ft | 6.6ft | 9.8ft | 13.1ft | 16.4ft | 19.7ft | 23ft | 26.2ft | 29.5ft |
32.8ft
FC| 363| 91| 40| 23| 15| 10| 7| 6| 4| 4
Distance| 36.1ft| 39.4ft| 42.7ft| 45.9ft| 49.2ft| 52.5ft| 55.8ft| 59.1ft|
62.3ft| 65.6ft
FC| 3| 3| 2| 2| 2| 1| 1| 1| 1| 1
ISO Diagrams
ISO Candela Diagram
ISO Lux Diagram
Chromaticity
Color Parameters
Color Temperature | Color Coordinate CIE 1931 | Color Coordinate CIE 1931 |
---|---|---|
CCT | x | y |
5635 K | 0.329 | 0.355 |
Color Deviation from Black Body Curve | Color Coordinate CIE 1964 | Color |
Coordinate CIE 1964
---|---|---
ߡuv| y| u
0.0052| 0.355| 0.199
Color Rendering Index| Red Component| Color Quality Scale
---|---|---
CRI| CRI – R9| CQS
92.5| 81.4| 92.5
Television Lighting Consistency Index| Color Fidelity| Color Gamut
---|---|---
TLCI| TM30 – Rf| TM30 Rg
86| 90.7| 104.3
TM-30 Details
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
3360 Davie Rd.
Davie, FL 33314
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice:
844-393-7575
Fax: 954-756-8015
Email:
chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet U.K.
Pod 1 EVO Park
Little Oak Drive, Sherwood Park
Nottinghamshire, NG15 0EB
UK
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110| Email:
UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet Benelux
Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97
Voice: +33 1 78 85 33 59| Email:
BNLtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet France
3, Rue Ampère
91380 Chilly-Mazarin
France| Email:
FRtech@chauvetlighting.fr
Website: www.chauvetprofessional.eu
Chauvet Germany
Bruno-Bürgel-Str. 11
28759 Bremen
Germany
Voice: +49 421 62 60 20| Email:
DEtech@chauvetlighting.de
Website: www.chauvetprofessional.eu
Chauvet Mexico
Av. de las Partidas 34 – 3B
(Entrance by Calle 2)
Zona Industrial Lerma
Lerma, Edo. de México, CP 52000
Voice: +52 728-690-2010| Email:
servicio@chauvet.com.mx
Website: www.chauvetprofessional.mx
Visit the applicable website above to verify our contact information and
instructions to request support.
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact
the dealer of the record.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>