WARNING: READ BEFORE CONTINUING
To reduce the risk of fire, electric shock or injury to persons using this
freezer, read all instructions and follow basic safety precautions before
using the unit, including the following:
Do not modify the plug provided with the unit. If it will not fit the outlet,
have a proper outlet installed by a qualified electrician.
Do not position equipment so it is difficult to disconnect from the power
supply.
While under warranty, do not attempt to repair or replace any part of the
freezer for servicing without first contacting the So-Low Service Department.
BEFORE CALLING THE MANUFACTURER’S TECHNICAL SUPPORT DEPARTMENT
Please have the model number of the unit, box identification number, and
serial number ready as well as the problem description. The model, serial
number and box id number can be found on the serial tag, which is located on
the interior left upper wall, or back of the unit.
SAVE THESE INSTRUCTIONS
So-Low Environmental Equipment Company 10310 Spartan
Drive Cincinnati, OH 45215-1221
Tel: 513-772-9410 http://www.so-low.com
For customer service: Email: sales@so-low.com
For parts replacement: Email: parts@so-low.com
For technical support: Email: service@so-low.com
Application Notes
Thank you for choosing and using our products! For your safe and convenient
use and reasonable maintenance of the equipment, please read the Operation
Instructions carefully before use and keep it properly for reference
The equipment operator can copy some chapters of this operation manual, but
only for internal use, for example, to instruct the user how to deal with
emergencies. These chapters are clearly marked in the catalog of the manual.
So-Low Environmental has obligation and responsibility for any instrument
damage caused by the user’s failure to use the equipment according to the
instructions or the method specified by the manufacturer.
Due to the rapid improvement of our products, the functions described in the
instructions may be inconsistent with those of the products you purchased.
Please refer to the physical functions.
- Please carefully read the Attention and Safety Precautions (in 2. Safety Instructions).
- During transportation or use, no violent vibration or collision is allowed, and the refrigerator shall be kept away from rain.
- Store in a clean room with humidity of no more than 80 %, no corrosive gas and good ventilation.
- Pharmacy/Medical refrigerators (hereinafter referred to as equipment) can only be operated by trained and authorized personnel.
- Maintenance of the equipment can only be completed by us, or an agent authorized by us.
- If the operator encounters any situation not mentioned in this manual, please contact So-Low Environmental or an agent authorized by us for the correct handling method.
- If the equipment is not used according to the method specified in the specification, it may be damaged.
- Try to use the accessories provided by us. If users would like to use other accessories, we will not be responsible for the adverse consequences caused therefrom.
- Equipment must be inspected and maintained regularly to ensure good operation of the equipment.
Tips
- Properly use protective equipment (including protective clothing, protective gloves, goggles, etc.)
- Keep good hygiene habits
- Please pay attention to safety when using this product
- Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerating circuit.
- Do not use electrical appliances inside the food/ice storage compartments unless they are o the type recommended by the manufacturer.
Safety Instructions
When using this product for the first time, please pay attention to the meaning of the following warning signs and carefully read the safety precautions, so that you can use this equipment safely and correctly.
| Warning! Failure to observe the precautions may result in serious personal
injury or death.
---|---
****| Protective conductor terminal
| Do not place it obliquely
| Beware of electric shock.
| This equipment is a precision instrument
| Attention! Failure to observe the precautions may result in personal injury
or equipment failure and related property losses.
| Risk of Exploration This sign indicates the risk of explosion when using
volatile and explosive chemicals.
| Avoid direct sunlight
| Beware of fire
Warning: Failure to observe the precautions may result in serious personal
injury or death.
Do not touch the equipment with wet hands to avoid electric shock; Equipment
shall not be grounded through gas pipeline, water supply pipeline, telephone
line or lightning rod, which may easily cause electric shock.
This equipment can only be installed by professional technicians or after-
sales maintenance personnel, it may cause electric shock or fire.
Please handle the power cord carefully to avoid short circuits or open
circuits. Please turn off the power before pulling out the power plug. Don’t
bundle the power cord, don’t press it under furniture or heavy objects.
After installation, the power plug must be within reach, so that the power
plug can be unplugged in time in case of emergency.
Be sure to install the equipment on solid and flat ground and take due care to
prevent tipping over. If the ground is not solid enough or the installation
location is not appropriate, it may cause the equipment to fall over and cause
equipment damage or personal injury.
Do not lengthen the power cord without authorization to avoid heating or fire.
Do not use the power supply that is not specified in the equipment design, to
avoid overheating, short circuit, and other faults.
This equipment adopts a 110V/60HZ AC power supply. If the operating voltage is
too low or too high, a suitable automatic voltage stabilizer must be installed
for cooperative use.
Please place the equipment stably and avoid shaking.
Do not place the equipment in a dangerous area, and do not operate the
equipment near flammable items to prevent explosion or fire accidents.
Do not place the equipment in areas exposed to the sun or rain, to prevent
danger such as short circuit or overheating.
Do not tilt or lay the equipment sideways, and do not impact the equipment
body; Refrigeration systems are installed in the equipment, which is easy to
be damaged by tilt or impact.
Please place the equipment in a dry and dust-free environment to avoid risks
such as overheating, and short circuit.
In case of unexpected sound, smell, smoke, etc. when the power is turned on,
please unplug the power in time and contact the manufacturer or supplier.
Please place the equipment in a dry and ventilated environment and ensure that
the equipment vents and instrument surfaces are not blocked or shielded by
walls or other objects; Do not use it in a poorly ventilated environment to
prevent damage caused by heat released by equipment.
It is forbidden to disassemble and modify this equipment without
authorization, to avoid potential safety hazards. In this case, So-Low will
not bear any responsibility for quality accidents.
It is forbidden to put flammable and explosive dangerous goods, strong
corrosive acids, alkalis and other items unsuitable for the equipment in the
equipment.
When storing toxic, harmful, or radioactive materials, please use the
equipment in safe areas. Improper use may cause harm to human health or the
environment.
Metal objects such as nails or iron wires shall not be inserted into any
aperture and gap or any outlet of the equipment, otherwise electric shock or
injury may be caused due to accidental contact between the above objects and
moving parts.
To ensure the normal operation and ventilation and heat dissipation of the
equipment, the back, left and right sides of the cabinet shall be at least 1-2
inches away from the wall, and the air inlet and air outlet must not be
blocked by obstacles!
**** This equipment must be connected to a ground wire.
Note: Failure to observe the precautions may result in personal injury or
equipment failure and related property losses.
It is forbidden to store living animals, flowers, or other items with strict
temperature requirements in the equipment.
When the equipment is running, do not touch the inner surface of the cabinet
without wearing protective gear.
Hold the handle and close the door to avoid pinching your fingers; When the
equipment is not used for a long time, please unplug it and pack it for
storage.
When restarting the equipment after power failure or power off, please check
the equipment settings first, otherwise the stored items may be damaged due to
the change of settings.
The equipment can be used for item preservation, not as production equipment!
Keep the keys in a safe location.
When handling the equipment, please be careful not to tip over the equipment,
to prevent equipment damage or personal injury.
When handling, it shall be lifted from the bottom, with the inclined plane is
not greater than 45°, and it shall be handled with care. Please use the
equipment in safe areas. Improper use may cause harm to human health or the
environment.
Precautions in Use
- Before putting the items into the equipment, please confirm that the temperature in the freezer storage chamber has reached the set value first, and then put the articles in batches. Every time you put in items; they shall not exceed 1/3 of the inner volume of the freezer storage chamber to prevent excessive temperature rise.
- The equipment temperature display value is the temperature at the temperature sensor in the freezer storage chamber.
- There is a certain gap between the displayed temperature and the actual temperature at the center of the equipment when the equipment just starts running, but as the equipment enters a stable state, the displayed temperature will gradually approach the actual temperature.
- Please use a diluted neutral cleaner to clean the equipment, and do not use brushes, acid, gasoline, soap powder, polishing agent, or hot water to clean the equipment, otherwise the painted surface and plastic rubber parts may be damaged. Be careful not to wipe plastic rubber parts with volatile solvents such as gasoline.
- When the equipment is not used for a long time, the power supply shall be cut off.
Product Installation
4.1 Installation Environment
- Ambient temperature: 16℃ ~ 32℃, the most ideal temperature is 18℃ ~ 25℃, and the air conditioning system shall be used when necessary.
- Relative humidity: ≤80%RH.
- There is no strong vibration and corrosive gas around.
- Avoid the existence of a large amount of dust.
- Avoid rocking or shaking the equipment.
- Elevation of the working position of the equipment: less than 2000m.
- Indoor use, pollution degree 2, and overvoltage category II.
- Input voltage AC single-phase 110V.
- There is no direct sunlight, other cold and heat sources, and strong electromagnetic interference, which will affect the normal operation of the control system and directly damage the system in severe cases.
4.2 Installation Site
To operate the equipment normally and obtain the best performance level, the
installation site of the equipment shall meet the following requirements:
- It cannot be installed in a narrow and closed space, and the door of the room shall not be smaller or lower than this equipment, which shall at least ensure the normal access of the equipment, to avoid the maintenance difficulties in case of equipment failure, which may result in damage to stored items due to the failure to repair the equipment in time.
- The installation floor must be solid, flat, non-combustible, and able to bear the weight of the equipment during operation.
- It shall be with good ventilation, and direct sunlight shall be avoided.
- Each piece of equipment needs to use a power outlet independently.
- Please ensure that the current by the power outlet shall be ≥10A, and the plug and outlet are firmly connected.
- Check the working voltage before use. In areas with unstable voltage, consider using a voltage stabilizer suitable for equipment load. The power of the voltage stabilizer is greater than 4KW to ensure that the input voltage requirements in the installation environment are met.
- Equipment shall be reliably grounded. If the power cord outlet is equipped with grounding wire, check whether the grounding is good before use. If the outlet is not equipped with grounding wire, it must be installed by professional engineers and technicians.
Attention: Since the ambient temperature has great influence on the
equipment, if the above environmental requirements cannot be met, the
equipment may not run normally. Please improve the environment before using
the equipment; The equipment is operated intermittently
4.3 Preparation before Use:
- Remove the outer packaging of all products (including the protective foam in the packaging box)
- Inventory of accessories: Please check the accessories and materials according to the packing list.
- Cleaning: Clean the product once before use.
4.4 First Power-on
When using the equipment for the first time, please follow these steps:
- After the equipment is placed, leveled, and cleaned, it shall stand for more than 24 hours, and then power it on to ensure the normal operation of the equipment.
- Under no-load condition, connect the power cord to a dedicated outlet with appropriate specifications.
- After plugging in, turn on the power switch of the equipment.
- Check whether the operating temperature of the equipment reaches the required value, observe the normal start and stop of the equipment for 24 hours, and put a small amount of items in the freezer after confirming the normal performance.
- Please store items in batches, with the items not exceeding 1/3 of the freezer volume each time.
- Try not to open the door during cooling, otherwise the temperature will rise.
4.5 Operation after Power Failure
- The equipment has a memory function for the set value. When the power is restored after power failure, the equipment will continue to operate before power failure.
- Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the compressor.
- We guarantee the normal operation of this equipment under certain conditions, but we are not responsible for any loss or damage of stored items after a power failure.
Notes:
-
A special person shall be responsible for checking and recording the running status of the equipment every day (record and check once every 2-4 hours). In case of failure or shutdown, the temperature in the freezer will rise.
If it cannot be repaired in a short time, please take out the stored items and transfer them to a place that meets the temperature requirements for storage to avoid damage to the items. -
Before putting items into the equipment, it shall be confirmed in advance whether the temperature range of the equipment meets the temperature requirement of the items, so as to avoid damage to stored items due to the difference between the settable temperature of the equipment and the required temperature of the items. Please pay attention not to block the air outlet and air inlet when putting items into the equipment.
-
Due to the refrigeration inertia, there is a certain difference between the actual display temperature and the set temperature of the equipment, which is a normal phenomenon.
-
The equipment is an item storage equipment, which cannot be used for routine production operations. It is strictly forbidden to put too many items which are relatively hot into the equipment at one time, otherwise the compressor will run for a long time, and be burned due to high temperature. Items must be put in batches, so as to ensure that the freezer is cooled step by step until the temperature required for storing items is reached.
-
Electrical appliances without production license shall not be used inside the equipment.
-
Do not change the set temperature frequently in a short time, otherwise the expected setting effect may not be achieved due to the large temperature inertia; Ensure that there is a certain air circulation space around the cabinet when putting in items, especially do not block the temperature sensor in the cabinet (for collecting the temperature of the cabinet), otherwise it will affect the stability and accurate control of the temperature in the freezer body!
-
Items shall not be placed directly at the bottom of the freezer, but on the bottom shelf, otherwise the refrigeration effect of the equipment will be affected.
-
When putting in items, if the moisture content of the items is too much or too little, it will affect the humidity change in the cabinet, so it is best to keep the items sealed; The humidity of the working environment will affect the change of humidity in the cabinet, especially if the door is opened too frequently and the door is not closed properly
Component Composition
Display control panel
DHK25-10SD/DHK40-10SD
MV30-4UCF/MV40-4UCF
- Due to the improvement of products and model diffierences, the actual products may be different from the diagram. Please refer to the actual products! The diagram is only used for functional parts description.
- Structure and composition The product consists of freezer body, door (glass door structure or foam door structure), refrigeration system and control system.
Intended use:
- Scope of application: It is suitable for storing items in hospitals, pharmacies, epidemic prevention stations, research institutions, biopharmaceuticals and other units.
- The storage temperature inside the box can be adjusted through the temperature button on the control panel, which is convenient to use and reliable in performance.
- The freezer comes with drawers, each of which can hold 40 pounds.
Operating Instructions
6.1 Function Introduction
Function description of Type A control panel(Applicable to MV40-4UCF,MV30-4UCF,DHK25-10SD,DHK40-10SD)
Control board introduction:
a. -25 is display window for temperature. Under normal operating
conditions, the average temperature of the freezer compartment in the cabinet
is displayed in units of °C; Different running status can be displayed in the
setup state (see below for details).
b. Door opening indicator : when the door is opened, the indicator light will
be on. when the door is opened more than 1 minute, the indicator lighting with
buzzer alarm, display “do”.
c. Fault indicator: The indicator is off when the product is operating
normally; the indicator is on when the product is operating abnormally.
d.“PRINT”: The system can retain 7 days of data for printing. Press the Print
key to print the temperature for the set period of time.
e. In parameter setting mode, move to the previous parameter or decrease the
value of the parameter. For example, when adjust the set temperature, press
this button to reduce the set temperature. When adjust the parameter value,
long press the key to quickly decrease the parameter.
f. In parameter setting mode, you can move to the next parameter or increase
the value of the parameter. For example, when adjust the set temperature,
press this button to increase the set temperature value. When adjust the
parameter value, press and hold the up button for a long time and the
parameter will increase rapidly. Under normal conditions, press and hold the
key for 3 seconds to import the U disk for 12 months.
g. is the button for set/mute, when there is no alarm state and the key is not
unlocked, press ,Displaying ambient temperature for 5 seconds and then
restores normal display; In the unlockedstate, press for 3 seconds, can enter
the user menu. When buzzer alarm (including high temperature alarm, door open
alarm, sensor fault alarm, etc.), in the locked state, first time press ,
Buzzer stops tweeting, 5 seconds after showing ambient temperature, resume
normal display (The key mute is only to turn off the buzzer of this abnormal
state alarm. If the fault is not eliminated, the buzzer will continue to alarm
when the next exception occurs), press again, buzzer alarms, After the ambient
emperature is displayed for 5 seconds, the cabinet temperature and alarm
status are restored. When the press is under unlocked state, can be used as a
set button. In the unlock state, in the parameter setting mode, press this key
to display the value and the parameter name. If the pressed time is longer
than 3 seconds, the setting will be saved and returned to normal interface.
h. USB data ;
Automatic export: when the U disk is connected to the USB interface, the
recorder buzzer will chirp once and display “on”. PDF files of data that not
currently exported will be generated in the U disk. After data transmission,
the buzzer will chirp once again and display “End”.After 6s, it will return to
normal display.
Note: when the data is very little, the digital tube will not display “on”
and “End”.
Manually export: If the button is under locked state, after connecting U disk
well and buzzer alarm for one time, press upper button for 3 seconds, digital
tube display “d01”, Press the up button or down button to adjust “d00~d12”,
press , The U disk internally generates a PDF file that generates this file
(d00) or generates the data recorded in the previous month (1-12).
Note: When the alarm of the digital tube flashes and displays tor,” the
recorder is not started: Meanwhile press and key for 3s. and “LoF” disappears,
the recorder is started.
Function settings **
**
a.Power on, open the power switch on the back of the cabient, the machine can
enter the working state;
b.User parameter settings:
Unlock: In the normal running state, press the key and time, the digital tube
will display the parameter code “0000”, and input the password “0005” (enter
the user menu password, enter “0099” to restore the key lock password to the
for 3 seconds at the same default “0005”), Unlock at this time. Press the key
digital tube displays the parameter code for 3 seconds after unlocking, the
“PS1” and enters the setting adjustment.
c.Use the up or down key to scroll through the parameters. The display order
is b1-b2-Set-H-Ln-y-r-S-F-Pt-tH1-P1-PS1.
Press the key to confirm the category. The first parameter name of this type
of parameter will be displayed.
1. Press or to scroll through the values
2. Press the to display the corresponding value
3. Press or to increase or decrease the value
4. Press the to temporarily store the modified value of the lock and return
to the display parameter.
5. If you need to modify other parameters, repeat steps 1-4.
6. Press the for more than 3 seconds to store the modified parameter and
return to the display parameter category.
d. Press the for more than 3 seconds, or if there is no button within 60
seconds, exit the parameter setting program.
Parameter display
NO.
| Menu item| Parameter Range| Suggested settings|
Remarks
---|---|---|---|---
1| b1| V1.0-9.9| 1.0| Hardware version
2| b2| V1.0-9.9| 1.1| Software version
3| Set| -10~-25| -25| Temperature setting
4
|
H
|
0.0~10.0
|
5.0
| Set value of high temperature alarm set+H; When H=0, the alarm is
deactivated; When the
temperature is higher than the high temp alarm set temperature alarm displays
H1
5
|
L
|
0.0~10.0
|
5.0
| Set value of low temperature alarm set-L; When L=0, the alarm is
deactivated; When the temperature is lower than low temp set the low
temperature alarm displays L1
6| Pt| 0~240min| 20| Print interval
7| tH1| 20.0~50.0℃| 40.0| Upper limit of ambient temperature alarm
8| PS1| 0000~9999| 0005| User menu password settings
9| MAX| –| –| The highest temperature since last clearance
10| NIN| –| –| The lowest temperature since last clearance
11| CLR| –| –| Clearance of the Max and Min temperature records
Quick setting of time after power on
After the power-on self-test on the display board is completed, the quick
setting menu is displayed
Menu item | Menu | Menu description | Set range | Default | Unit |
---|---|---|---|---|---|
Quick Settings menu | n | Set logger module time – year | 10~50 | / | |
y | Set logger module time – month | 1~12 | — | / | |
r | Set logger module time – day | 01~31 | — | / | |
S | Set logger module time – hour | 00~23 | — | / | |
F | Set logger module time – minute | 00~59 | — | / | |
Pt | Print interval | 0~240 | 20 | min | |
SCY | Temperature data recording period | 0~240 | |||
0: shielded recorder | 10 | min |
If there is no operation for 60 seconds under the quick setting menu, it will automatically exit the quick setting menu and return to normal display.
Alarm display
Alarm Code | Fault description |
---|---|
H1 | High temperature alarm |
L1 | Low temperature alarm |
H2 | High ambient temperature alarm |
door | Door open alarm |
PF | Power failure alarm |
bL | Low battery alarm |
Er | Data Logging not connected |
LoF | Data Logging not started |
EE | Communication error |
6.2 Functional fittings
1.Printer
Automatic printing:
When the printing interval Pt is not 0, the printer prints the current data
every Pt minutes.
Note: When the printing interval Pt is less than the recording interval
SCy, it is printed according to the recording interval; the remaining printing
intervals are printed as an integral multiple of the recording interval Scy,
that is: the printing interval Pt should be set as an integral multiple of the
recording interval.
Manual printing:
When the key is unlocked and the working voltage is normal, press the print
key to display “P01” by the digital tube, press the up key or down key to
adjust “P00~P07.” Press the set/mute multiplexing key or print key, and the
printer will cancel the manual printing (P00) or print the data recorded in
the previous days (1 ~ 7), with the data interval same as the automatic
printing interval. Printing paper installation:
The printing paper has been installed at the factory. When the paper is used
up after a long time, you may purchase the same paper for installation. The
installation steps are as follows:
- Click the cylindrical button on the printer to open the cover of the printer;
- Put the printing paper into the printer box and pull the paper head of the roll so that the paper slightly exposes from the upper port of the box cover after the box cover of the printer is closed.
- Close the box cover.
2.Remote alarm terminal and RS485 interface
The remote alarm terminal is installed in the back of refrigerator and the
alarm signal is output by the terminal.
The terminal bearing capacity is SELV DC 30V, 2A.
Defrost,Discontinuation and Maintenance
Warning:
- In order to prevent people from getting electric shock or injury, please cut off the power supply of the equipment before any repairs and maintenance
- Make sure you don’t inhale drugs or suspended particles around it when maintaining the equipment, otherwise it will harm your health
7.1. Equipment Maintenance
Defrosting: The equipment will automatically defrost during the working
process for the convenience of use. Cleaning and maintenance: The equipment
should be cleaned and maintained regularly (for safety, please remove the
power plug), and the inner and outer surfaces of the freezer should be wiped
with a warm, damp soft cloth.
Notes:
- Do not use sharp metal appliances during defrosting to avoid damage to the freezer.
- Do not position the equipment so that it is difficult to operate the disconnecting device of separable plug.
- Protection impairment if used in a manner not specified by the manufacturer.
- The power relay switch on the back of the case can not only contact and open the power circuit, but also provide immediate protection in the event of short-circuit faults, severe loads and undervoltage in the power circuit, and it can also be used to start the compressor infrequently to protect the equipment.
7.2. Equipment Discontinuation
Deactivation: If the equipment is stored in an unsupervised area for a long
time and not used, the power supply should be cut off and the inner and outer
surfaces of the freezer should be cleaned with a warm, damp soft cloth, aired
and sealed. The equipment must be locked to ensure that children cannot open
the freezer door.
Scrapping: When the equipment reaches the end of its service life, it should
be scrapped and must be handed over to a qualified professional recycling
agency for disposal per local regulations. Nonprofessionals are not allowed to
disassemble and break down the
equipment without authorization. The scrapped equipment should be placed in a
designated area inaccessible to children to avoid danger.
7.3 Maintenance, Replacement, and Recovery of Rechargeable Batteries
Battery installation position: top of the freezer body and bottom inside
the electrical box.
- Battery maintenance
- In order to prolong the service life of the battery and avoid the product being left unused for a long time, the product must be operated for more than 24 hours every month to facilitate charging.
- When the equipment is not used for a long time, it should be connected to the working power regularly (generally once a month), and the power lock switch should be turned on so that the equipment can run for a period of time to complete charging, and each charging time should be no less than 24 hours;
- When the working power supply is interrupted, the power lock switch of the equipment shall be turned off in time, otherwise it will cause power loss in battery and even permanent damage to the battery in severe cases;
- The main power switch must be turned off during a long-term power outage or during transportation, otherwise long-term discharge causes power loss in battery and even permanent damage to the battery, and the display is abnormal after re-energizing;
- The battery is a consumable, with a service life of about 2-3 years. If the battery is used improperly, such as power loss or reaching the end of battery life, it will cause a low battery alarm (refrigeration is not affected, but there is an alarm failure and influence to the use function of the printer, please contact our local distributor after-sales staff for replacement).
- Battery replacement and recovery
- Turn off the power switch and pull out the power plug from the outlet;
- Remove the screws on the electrical box with a screwdriver. (Note: There are high-voltage electrical components in the electrical box, therefore before opening, turn off the power supply, unplug the power plug and turn off the power lock switch of the freezer, and the electrical box can only be opened by qualified engineers or maintenance personnel).
- Pull out the battery connecting cable; (Before unplugging the battery fixing cable, pay attention to the cathode/anode of the battery and the sequence of the connecting cables, so as to prevent burning down the control system due to installation of the new battery with cathode/anode reversed. Generally, the red wire is connected to the cathode, and the black wire is connected to the anode.
- Use a screwdriver to remove the fastening screws on the battery fixing plate and take out the battery;
- The battery model is BT-12M4.0AC(12V4.0AH);
- For a replaced battery that can be recycled, please contact the local battery recycling agency.
After-sales service
Any product may fail. Please observe the operation of equipment while in use.
Fan motor replacement time: about 6 years; Service life of the product: 10
years.
Problems|
Causes and solutions
---|---
Equipment does not work| Please make sure that the outlet is energized.
Please make sure power plug is plugged in,not loose.
Please make sure the power fuse is not disconnected.
Please make sure the supply voltage is appropriate,not too low or too high.
Compressor is not running| Please make sure that the temperature is set
correctly.
Please check whether the temperature inside the cabinet is too low.
The temperature does not reach the set value| Please make sure that the door
is closed tightly and don’t open it too many times during a short time.
Please don’t put too many items in at one time.
Please make sure that the ambinet temperature is not too high.
High noise| Please make sure that the freezer body is placed on a flat ground.
Please make sure that the freezer body does not contact the wall.
Condensation on freezer body surface| In rainy and humid seasons, door
condensation is normal, and it shall be wiped off with a dry cloth.
Undesirable odor| Equipment needs to be cleaned. Items with heavy smell are
not packed.
The door is not closed properly,
and the cool air leaks
| After the equipment is used for a period of time, the door seal becomes hard
and deformed.
Maintenance method: Blow the deformed part of the hot seal with a blower to
soften it, and then close and compress it after the door seal becomes soft.
The alarm lamp flashes and the buzzer is triggered| If the items were just put
in,it will be automatically eliminated after running for a period of time when
the temperature is stable.
Please check if it is because the door is not locked.
Please check if it is because of the low battery,which will be automatically
eliminated after a period of running.
Please make sure the temperature is not exceeding the standard.
The following conditions are not faults:
-
When the compressor starts and stops, the equipment parts will make a slight impact sound
-
When overheated items are put in after the door is opened, high temperature alarm and high humidity alarm will be triggered in the control system (if this function is available, please refer to the alarm display table);
Solution: Put the items into the equipment after they are naturally cooled. Put the items in small quantities in batches, and do not put too much at a time. After the system runs stably, the high temperature alarm and high humidity alarm will be released automatically. -
Slight sound of running water caused by refrigerant flowing in the pipeline.
Notes:
- The equipment can only be repaired, maintained or improved by the engineers certified by us, so as to ensure the normal operation of the equipment and the compliance with corresponding safety standards.
- Please clean and disinfect the equipment before notifying the maintenance engineer; During the warranty period of the equipment, the Company will not undertake the warranty obligation if the fault or damage is caused by improper use of the user.
- Ambient temperature for storage: -40°C-+55°C, relative humidity: 10% ~ 90%.
Specification
Model| Ambient temperature| Refrigerant| Rated voltage
(v~)| Rated frequency (Hz)| Temp Range (°C)| Effective
volume (L)
---|---|---|---|---|---|---
MV30-4UCF| 16~32℃| R600a| 110| 60|
-10~-25℃| 90
MV40-4UCF| 16~32℃| R290| 110| 60|
-20~-40℃| 90
DHK25-10SD| 16~32℃| R600a| 110| 60|
-10~-25℃| 270
DHK40-10SD| 16~32℃| R290| 110| 60|
-20~-40℃| **** 270
- The foaming material of this product is cyclopentane.
Accessories
**** Name | **** Operation Manual | **** Key | **** Defrosting shovel |
---|---|---|---|
**** Number | **** 1 | **** 2 | **** 1 |
- The specific packing list shall be subject to the physical objects received.
Circuit diagram
Note: some models don’t have the optional parts within the Compressor set dotted line, the detailed is subject to the available