Product Description

SXWS sensors are a family of living space sensors for use with MP and RP Series IP controllers that use the EcoStruxure Building Operation software user interface. These sensors use an RJ-45 Sensor Bus that provides communication and power from the controller. SXWS living space sensors are modular and are ordered in two parts: the sensor base and the cover. Four SXWS communicating sensor base models are available that can be paired with any SXWS cover model. Carbon Dioxide (CO2), Relative Humidity, and Temperature sensor base options provide an efficient, cost-effective solution for living space air quality and comfort needs.

Features

Medium matte white housing or optimum glass panel housing available in white or black

Applicable Documentation

Title Description
SXWS Living Space Sensor Base Installation instructions for all base

variants.
SXWS Living Space Sensor Button and Occupancy Covers| Installation instructions for 3-button covers with and without occupancy sensors and blank cover with occupancy sensor
SXWS Living Space Sensor Touchscreen Cover| Installation instructions for touchscreen models with and without occupancy sensors
SXWS Living Space LCD Temperature Sensor| LCD temperature sensor base and cover installation instructions
SXWS Living Space Resistive Temperature Sensor| Non-communicating temperature sensor installation instructions

Specifications

Operating Environment

Operating temperature| 0 to 50 °C (32 to 122 °F)
Operating humidity range| 0 to 95% RH, non-condensing
Housing material| High impact ABS plastic Flammability rating UL 94 V-0
Mounting location| Not suitable for wet locations. For indoor use only.
Regulatory Information

Agency approvals

| UL 916

European conformance CE: EN61000-6-3

EN61000 Series – industrial immunity standard

FCC Part 15 Class B, REACH, RoHS,

Green Premium, RCM (Australia), ICES-003 (Canada), EAC (Russia)

Available Products

SXWS Sensor Bases

Model Number

|

Description

|

Temp

|

RH

|

CO 2

|

Cover

| IP Controller System Bus (Communicating)
---|---|---|---|---|---|---
SXWSBTXXXSXX| Sensor Base, Temperature| X| | | Not Included| X
SXWSBTHXXSXX| Sensor Base, Temperature, Humidity| X| X| | Not Included| X
SXWSBTXCXSXX| Sensor Base, Temperature, CO2| X| | X| Not Included| X
SXWSBTHCXSXX| Sensor Base, Temperature, Humidity, CO2| X| X| X| Not Included| X

**SXWS Covers***

Model Number

| 61mm (2.4”) Color Touchscreen with Light & Blind Control|

Override

|

Setpoint

| Off-Touchscreen Light & Blind Control Buttons| Off-Touchscreen Light Control Buttons|

Occupancy Sensor (PIR)

|

Housing Finish

---|---|---|---|---|---|---|---
SXWSCDXSELXX| X| X| X| | | | Medium, White
SXWSC3XSELXX| | X| X| | | | Medium, White
SXWSCBXSELXX| | | | | | | Medium, White
SXWSCDPSELXX| X| X| X| | | X| Medium, White
SXWSC3PSELXX| | X| X| | | X| Medium, White
SXWSCBPSELXX| | | | | | X| Medium, White
SXWSCDXSELXW| X| X| X| | | | Optimum, White
SXWSC3XSELXW| | X| X| | | | Optimum, White
SXWSCBXSELXW
| | | | | | | Optimum, White
SXWSCDPSELXW| X| X| X| | | X| Optimum, White
SXWSC3PSELXW| | X| X| | | X| Optimum, White
SXWSCBPSELXW| | | | | | X| Optimum, White
SXWSCDXSELXB| X| X| X| | | | Optimum, Black
SXWSC3XSELXB| | X| X| | | | Optimum, Black
SXWSCBXSELXB**| | | | | | | Optimum, Black
SXWSCDPSELXB| X| X| X| | | X| Optimum, Black
SXWSC3PSELXB| | X| X| | | X| Optimum, Black
SXWSCBPSELXB| | | | | | X| Optimum, Black
SXWSC2XSELXW| X| X| X| | X| | Optimum, White
SXWSC4XSELXW| X| X| X| X| | | Optimum, White
SXWSC2PSELXW| X| X| X| | X| X| Optimum, White
SXWSC4PSELXW| X| X| X| X| | X| Optimum, White
SXWSC2XSELXB| X| X| X| | X| | Optimum, Black
SXWSC4XSELXB| X| X| X| X| | | Optimum, Black
SXWSC2PSELXB| X| X| X| | X| X| Optimum, Black
SXWSC4PSELXB| X| X| X| X| | X| Optimum, Black

Dimensions

Dimensions mm (in.)


Optimum Housing

Medium Housing

Precautions

  • This product is not intended for life or safety applications.
  • Do not install this product in hazardous or classified locations.
  • Read and understand the instructions before installing the product.
  • Turn off all power supplying equipment before working on it.
  • The installer is responsible for conformance to all applicable codes.

If this product is used in a manner not specified by the manufacturer, the protection provided by the product may be impaired. No responsibility is assumed by the manufacturer for any consequences arising out of the use of this material

SXWS Base Installation

  • * With sensor base fully installed, align top of cover to mounting tabes on top of sensor base. Swing cover downward until it latches at the bottom.
    • Install locking screw to secure cover in closed position.