Gima 22005 Sterile Urethral Catheter For Single Use Instruction Manual

June 15, 2024
GIMA

Gima 22005 Sterile Urethral Catheter For Single Use

Gima-22005-Sterile-Urethral-Catheter-For-Single-Use-
PRODUCT

Product Information

Specifications

  • Product Name: Sterile Urethral Catheter for Single Use (Nelaton Catheter)
  • Type: Boy, Girl, Man, Woman
  • Sizes: Straight point / Standard point
  • Structural Composition: The product consists of a drainage funnel and tube

Indications:

The product is indicated for urine obstruction and urinary retention, etc.

Contraindications:

People who are allergic to PVC materials should not use this product.

Performance Features:

  • For single use and sterile
  • A. The tube, head end, and hole are free from contaminants.
  • B. The surface is smooth, the top is round and without pits, and the inner cavity is clean and smooth.

Attention:

The following instructions should be followed carefully for proper usage of the product.

Product Usage Instructions

Step 1: Preparing for Use

Before using the sterile urethral catheter, ensure that you have clean hands and a clean working area. Open the packaging of the catheter and inspect it for any damages or signs of contamination. If the packaging is damaged or the catheter appears contaminated, do not use it and contact the manufacturer or supplier for a replacement.

Step 2: Positioning

Determine the appropriate position for the patient based on their gender and specific medical condition. Provide privacy and comfort to the patient during the procedure.

Step 3: Lubrication

Apply a water-soluble lubricant to the tip of the catheter to ease insertion. Avoid using oil-based lubricants as they can damage the catheter.

Step 4: Insertion

Gently insert the catheter into the urethra according to the provided guidelines and the patient’s anatomy. Take care to avoid any resistance or discomfort during insertion.

Step 5: Drainage

Once the catheter is inserted, urine should start to flow through the catheter. Ensure that the drainage funnel is positioned correctly to collect the urine. Monitor the urine flow and adjust the position of the catheter if necessary.

Step 6: Removal

When the desired amount of urine has been drained or as instructed by a healthcare professional, carefully remove the catheter from the patient’s urethra. Dispose of the used catheter in a proper medical waste container.

Step 7: Post-Procedure Care

After removing the catheter, ensure that the patient is comfortable and provide any necessary post-procedure care. Clean and disinfect the area as required.

FAQ (Frequently Asked Questions)

Q: Can I reuse the sterile urethral catheter?

A: No, the sterile urethral catheter is designed for single-use only. Reusing it can lead to contamination and increase the risk of infection.

Q: How should I store the sterile urethral catheter?

A: Store the sterile urethral catheter in a cool, dry place, away from direct sunlight and extreme temperatures. Follow the storage instructions provided by the manufacturer.

Q: What should I do if the catheter gets blocked during se?

A: If the catheter gets blocked and urine flow stops, do not force it. Contact a healthcare professional for assistance or consider replacing the catheter if necessary.

REF

  • F5110.10 (Gima 22003)
  • F5110.12 (Gima 22004)
  • F5110.14 (Gima 22005)
  • F5110.16 (Gima 22006)
  • F5110.18 (Gima 22007)
  • F5100.08 (Gima 22022)
  • F5100.10 (Gima 22023)
  • F5100.12 (Gima 22024)
  • F5100.14 (Gima 22025)
  • F5100.16 (Gima 22026)

Jiangsu Suyun Medical Materials Co., Ltd. No.18
Jin Qiao Road Dapu Industrial Park 222002 Lianyungang JIANGSU PROVINCE, PEOPLE’S REPUBLIC OF CHINA Made in China

Shanghai International Holding Corp. GmbH (Europe) Eiffestraße, 80, 20537, Hamburg, Germany

Gima S.p.A.
Via Marconi, 1 – 20060 Gessate (MI) Italy gima@gimaitaly.comexport@gimaitaly.com www.gimaitaly.com

Product name:
Sterile single-use urethral catheter (Nelaton catheter)

Type:
boy, girl, man, woman

Sizes:
Straight point/Standard point

Intended use:
For temporary voiding by inserting it into the bladder through the urethra when patients cannot urinate themselves.

Target users:
It can be used by trained doctors, nurses, patients or accompanying staff.

Structural composition:
The product is composed of drainage funnel and tube

Indications:
Urinary obstruction and urinary retention, etc.

Contraindications:
People who are allergic to PVC materials should not use this product.

Patient group:
Patients with urinary retention caused by urinary tract obstruction.

Saving critically ill patients.
Patients requiring diagnosis and treatment of bladder disorders. People undergoing surgery. Patients with spinal cord injury.

Performance features:
single use and sterile

Performance features:

  • A. The tube, head end and hole are free of contaminants.
  • B. The surface is smooth, the top is round and without pits, the inner cavity is clean and smooth.

Method

  • a. Wash your hands and put on gloves to clean around the urethral opening. Those with a foreskin should have the sliding foreskin down to expose and clean the urethral opening.
  • b. After preparing for catheterization, open the individual package from the opening.
  • c. Lubricate the catheter with medical liquid paraffin or medical silicone oil.
  • d. Slowly introduce the urinary catheter into the bladder through the urethra normal catheterization.
    Any residual risks and unwanted side effects: none Installation information: none Clinical benefits: The product helps patients with temporary voiding.

Attention

  • a. When using the product, aseptic requirements must be followed operating specifications and relevant regulations become strict implemented and the product can be used by trained people doctors, nursing staff, patients or accompanying persons staff.

  • However, if patients or accompanying staff are experiencing a perform urinary catheterization, use this under supervision of professional medical personnel. During use, the operator or patient are treated in a timely manner according to medical regulations.

  • b. If you have any doubts about the quality during use, please stop immediately with the use and inform our company quickly.

  • c. The product must be sterilized with EO and the product must be sterile.

  • d. The product is disposable and must be disposed of after use destroyed.

  • e. Check the individual packaging before use.

  • f. Do not use if package is opened or damaged.

  • g. Sterile and valid for 5 years. Do not use after the expiry date.

  • h. This product must be used in combination with a urine container. When used, it should splash urine and pollution of the environment are prevented.

  • i. Discard after use. After use, the products must be are collected, transported, stored and disposed of to ensure that they are harmless to human health and the environment. If it product can be disposed of according to local medical waste disposal regulations.

  • j. If the product is used in a household environment, it must be disposed of as household hazardous waste after use.
    The product is collected, transported, stored and disposed of by a designated facility or company.
    Or the product can be disposed of according to local medical waste disposal regulations.

  • k. All serious incidents relating to the medical device supplied by us must be reported to the manufacturer and the competent authority of the Member State where your registered office is located.

Storage:
The product should be stored at a well-ventilated room temperature.

GIMA WARRANTY CONDITIONS
The standard B2B Gima warranty of 12 months is applied

Symbol index

  • Date of manufacture
  • Manufacturer
  • Keep away from sunlight
  • Don’t use if package is damaged
  • Imported by
  • Keep in a cool, dry place
  • aution: read instructions (warnings) carefully
  • Sterilized using ethylene oxide
  • Authorized representative in the European community
  • Medical Device
  • Consult instructions for use
  • Disposable device, do not re-use
  • Lot number
  • Medical Device compliant with Regulation (EU) 2017/745
  • Expiration date
  • Product code
  • Single sterile barrier system in protective outer packaging
  • Do not resterilize
  • Temperature limit

Read User Manual Online (PDF format)