EVOLVE RSAE Series Poles Street Light Poles and Brackets User Guide

June 15, 2024
EVOLVE

EVOLVE RSAE Series Poles Street Light Poles and Brackets

Product Information

Specifications

  • Series: RSAE
  • Type: Round | Straight | Aluminum
  • Construction:
    • Shaft: One-piece straight aluminum with round cross-section
    • Extruded shafts of 6061-T6 aluminum in 1/8, 3/16, or 1/4 thickness
    • Base plate of 356 cast aluminum
    • Bolt Covers: Four (4) individual bolt covers provided, painted to match pole and base finish
    • Base Cover: 2-Piece base cover supplied with 3 diameter poles
    • Pole Cap: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available
    • Hand Hole: Rectangular 3×5 aluminum hand hole frame (2.38 x 4.38 opening); Mounting provisions for grounding lug located behind gasketed cover
    • Anchor Bolt: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling
  • Finish:
    • Top View: Hand Hole, Bolt Circle
    • Overall Height: 8′ – 30′
    • Base Detail: Handhole 18, Pole Cap, Bolt Covers, Cast Base Plate, Clamping Allowance, Leveling Nut, Anchor Bolt, Projection, Foundation/Footing (by others), Tenon

Product Usage Instructions

Step 1: Determine Pole Specifications
Refer to the ordering information section to determine the specifications of the RSAE pole required for your project. Take note of the series, height, shaft thickness, mounting, poledrilling, finish, and any additional options required.

Step 2: Installation

  1. Prepare the installation site by ensuring a suitable foundation or footing is in place. The foundation/footing should be constructed by others according to local regulations.
  2. Position the pole in the desired location and ensure it is level.
  3. Use the provided galvanized anchor bolts to secure the pole to the foundation/footing. Each pole requires four anchor bolts.
  4. Tighten the anchor bolts using the provided washers and nuts to ensure a secure installation.

Step 3: Mounting Luminaires

  1. Determine the desired side or top mounting location for the luminaires on the pole.
  2. Use the appropriate mounting orientation logic shown in the ordering information section to specify the mounting location.
  3. Install the luminaires on the specified mounting location using the universal drill pattern (UDP) provided on top of the pole. Refer to the UDP drill patterns for specific mounting options.

FAQ

  • Can I customize the finish of the RSAE poles?
    Yes, you can contact the factory for custom color options.

  • What are the available accessories for the RSAE poles?
    The accessories are ordered separately. Please refer to the separate accessory catalog for more information.

APPLICATIONS
Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location.

CONSTRUCTION

Shaft: One-piece straight aluminum with round cross section; Extruded shafts of 6061-T6 aluminum in 1/8”, 3/16”, or 1/4” thickness. Base plate of 356 cast aluminum

Bolt Covers: Four (4) individual bolt covers provided, painted to match pole and base finish
Base Cover: 2-Piece base cover supplied with 3” diameter poles
Pole Cap: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available
Hand Hole: Rectangular 3×5 aluminum hand hole frame (2.38” x 4.38” opening); Mounting provisions for grounding lug located behind gasketed cover
Anchor Bolt: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling

EVOLVE-RSAE-Series-Poles-Street-Light-Poles-and-Brackets-fig-
\(1\)

FINISH

  • Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness
  • Powder paint finish coat available in three standard colors; Custom colors available; RAL number preferable

Example : RSAE16-40A-2-E1-DKBZ-VM2

EVOLVE-RSAE-Series-Poles-Street-Light-Poles-and-Brackets-fig-
\(3\)

NOTES:

  1. Specify option location using MOUNTING ORIENTATION logic shown on this page.
  2. Single-digit numbers are allowed in ordering information.
  3. UDP allows mounting of most popular fixtures on the market.

ACCESSORIES ORDER SEPARATELY

CATALOG NUMBER DESCRIPTION
**VM2SXX*** 2nd mode vibration damper

XX = 08 for 8’, 12 for 12’, 15 for 16’, 20 for 20’, and 24’ for 24’

MOUNTING ORIENTATION

EVOLVE-RSAE-Series-Poles-Street-Light-Poles-and-Brackets-fig-
\(4\)

DRILL PATTERNS

EVOLVE-RSAE-Series-Poles-Street-Light-Poles-and-Brackets-fig-
\(6\)

CATALOG NUMBER

| HEIGHT| NOMINAL SHAFT DIMENSIONS| WALL THICKNESS| BOLT CIRCLE

(SUGGESTED)

| BOLT SQUARE (RANGE)| BASE PLATE DIAMETER| ANCHOR BOLT SIZE| BOLT PROJECTION| POLE WEIGHT
---|---|---|---|---|---|---|---|---|---
FEET| METERS
RSAE10-40A| 10| 3.0| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 27
RSAE12-40A| 12| 3.7| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 31
RSAE14-40A| 14| 4.3| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 36
RSAE16-40A| 16| 4.9| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 40
RSAE18-40A| 18| 5.5| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 45
RSAE20-40A| 20| 6.1| 4” round| 0.125”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 50
RSAE10-40B| 10| 3.0| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 38
---|---|---|---|---|---|---|---|---|---|---
RSAE12-40B| 12| 3.7| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 44
RSAE14-40B| 14| 4.3| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 51
RSAE16-40B| 16| 4.9| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 58
RSAE18-40B| 18| 5.5| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 65
RSAE20-40B| 20| 6.1| 4” round| 0.188”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 71
RSAE12-40C| 12| 3.7| 4” round| .25”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 57
---|---|---|---|---|---|---|---|---|---|---
RSAE14-40C| 14| 4.3| 4” round| .25”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 66
RSAE16-40C| 16| 4.9| 4” round| .25”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 75
RSAE18-40C| 18| 5.5| 4” round| .25”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 83
RSAE20-40C| 20| 6.1| 4” round| .25”| 6.75”| 4.77”| 9.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 92
RSAE12-50B| 12| 3.7| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 56
---|---|---|---|---|---|---|---|---|---|---
RSAE14-50B| 14| 4.3| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 64
RSAE16-50B| 16| 4.9| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 73
RSAE18-50B| 18| 5.5| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 81
RSAE20-50B| 20| 6.1| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 90
RSAE25-50B| 25| 7.6| 5” round| 0.188”| 7.75”| 5.48”| 10.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 111
RSAE16-60A| 16| 4.9| 6” round| 0.125”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 60
---|---|---|---|---|---|---|---|---|---|---
RSAE18-60A| 18| 5.5| 6” round| 0.125”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 67
RSAE20-60A| 20| 6.1| 6” round| 0.125”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 74
RSAE25-60A| 25| 7.6| 6” round| 0.125”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 91
RSAE18-60C| 18| 5.5| 6” round| .25”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 127
---|---|---|---|---|---|---|---|---|---|---
RSAE20-60C| 20| 6.1| 6” round| .25”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 140
RSAE25-60C| 25| 7.6| 6” round| .25”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 174
RSAE30-60C| 30| 9.1| 6” round| .25”| 8.75”| 6.19”| 11.62” Dia x 1.88” Thk| 3/4”x30”x3”| 2-3/4”| 208

NOTES: The factory-supplied template must be used when setting anchor bolts. Current will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts.

  1. EHH EXTRA HANDHOLE
  2. C05 – C07 – C20 – COUPLING
  3. VM2 – VIBRATION DAMPER 2ND MODE
  4. VM2SXX – VIBRATION DAMPER 2ND MODE
  5. GFI – 20 AMP GFCI RECEPTACLE & COVER

OPTION ORIENTATION

Follow the logic below when ordering location-specific options. For each option, include its orientation (in degrees) and its height (in feet).

Example: Option C07 should be ordered as: RSAE20-40A-TA-E1-DBT-CO7-0-15 (.5″ coupling on the handhole/arm side of pole, 15 feet up from the pole base) 1’ spacing required between option. Consult factory for other configurations.

EVOLVE-RSAE-Series-Poles-Street-Light-Poles-and-Brackets-fig-
\(12\)

ASCE 7-05 wind map EPA Load Rating –

3-second gust wind speeds (Use for all locations except Florida)


Catalog Number| 85| 90| 100| 105| 110| 120| 130| 140| 145| 150
RSAE10- 40A| 9.0| 7.9| 6.2| 5.5| 4.8| 3.9| 3.2| 2.7| 2.5| 2.3
RSAE12- 40A| 6.8| 5.9| 4.5| 3.9| 3.4| 2.6| 2.1| 1.7| 1.6| 1.4
RSAE14- 40A| 5.1| 4.4| 3.1| 2.6| 2.2| 1.6| 1.2| 0.9| 0.8| 0.7
RSAE16- 40A| 3.8| 3.2| 2.1| 1.6| 1.3| 0.7| 0.5| NR| NR| NR
RSAE18- 40A| 2.7| 2.1| 1.2| 0.8| NR| NR| NR| NR| NR| NR
RSAE20- 40A| 1.7| 1.2| NR| NR| NR| NR| NR| NR| NR| NR
RSAE10- 40B| 13.7| 12.1| 9.6| 8.6| 7.7| 6.3| 5.3| 4.5| 4.2| 3.9
---|---|---|---|---|---|---|---|---|---|---
RSAE12- 40B| 10.7| 9.4| 7.3| 6.5| 5.7| 4.6| 3.8| 3.2| 3.0| 2.7
RSAE14- 40B| 8.4| 7.3| 5.6| 4.9| 4.2| 3.3| 2.7| 2.2| 2.0| 1.9
RSAE16- 40B| 6.6| 5.8| 4.2| 3.6| 3.0| 2.2| 1.8| 1.4| 1.3| 1.1
RSAE18- 40B| 5.1| 4.3| 3.0| 2.4| 2.0| 1.3| 1.0| 0.7| 0.6| 0.5
RSAE20- 40B| 3.8| 3.1| 2.0| 1.5| 1.1| 0.5| NR| NR| NR| NR
RSAE12- 40C| 14.1| 12.5| 9.9| 8.8| 7.9| 6.4| 5.4| 4.6| 4.2| 3.9
---|---|---|---|---|---|---|---|---|---|---
RSAE14- 40C| 11.3| 9.9| 7.7| 6.8| 6.0| 4.8| 4.0| 3.4| 3.1| 2.9
RSAE16- 40C| 9.1| 7.9| 6.0| 5.3| 4.6| 3.5| 2.9| 2.4| 2.2| 2.0
RSAE18- 40C| 7.3| 6.3| 4.6| 3.9| 3.3| 2.4| 1.9| 1.6| 1.4| 1.2
RSAE20- 40C| 5.7| 4.8| 3.4| 2.8| 2.3| 1.5| 1.1| 0.8| 0.7| 0.6
RSAE12- 50B| 18.1| 16.0| 12.9| 11.7| 10.6| 8.9| 7.5| 6.4| 5.9| 5.5
---|---|---|---|---|---|---|---|---|---|---
RSAE14- 50B| 14.6| 12.8| 10.2| 9.2| 8.4| 7.0| 5.8| 5.0| 4.6| 4.3
RSAE16- 50B| 11.9| 10.3| 8.1| 7.3| 6.6| 5.4| 4.5| 3.8| 3.5| 3.3
RSAE18- 50B| 9.5| 8.2| 6.3| 5.7| 5.1| 4.2| 3.4| 2.8| 2.6| 2.4
RSAE20- 50B| 7.5| 6.4| 4.8| 4.3| 3.8| 3.0| 2.4| 2.0| 1.8| 1.6
RSAE25- 50B| 3.8| 2.9| 1.9| 1.6| 1.3| 0.9| 0.6| NR| NR| NR
RSAE16- 60A| 11.9| 10.6| 8.4| 7.6| 6.9| 5.7| 4.7| 4.0| 3.7| 3.4
---|---|---|---|---|---|---|---|---|---|---
RSAE18- 60A| 9.5| 8.4| 6.7| 6.0| 5.4| 4.4| 3.6| 3.0| 2.8| 2.5
RSAE20- 60A| 7.5| 6.5| 5.1| 4.6| 4.1| 3.3| 2.7| 2.2| 2.0| 1.8
RSAE25- 60A| 3.6| 3.1| 2.2| 1.9| 1.6| 1.1| 0.8| 0.5| NR| NR
RSAE18- 60C| 21.4| 19.1| 15.5| 14.0| 12.0| 9.9| 8.3| 7.0| 6.5| 6.0
---|---|---|---|---|---|---|---|---|---|---
RSAE20- 60C| 17.9| 15.9| 12.8| 11.6| 10.5| 8.1| 6.8| 5.7| 5.2| 4.8
RSAE25- 60C| 11.4| 10.1| 8.0| 7.2| 6.5| 4.8| 3.9| 3.2| 2.9| 2.6
RSAE30- 60C| 6.9| 6.0| 4.6| 4.1| 3.6| 2.4| 1.8| 1.4| 1.2| 1.1
Florida Building Code 2017 EPA Load Rating – 3 second gust wind speeds (Use for Florida only)

Catalog Number| 115| 120| 130| 140| 150| 160| 170| 180
RSAE10- 40A| 6.4| 5.8| 4.7| 3.8| 3.1| 2.5| 2.4| 2.3
RSAE12- 40A| 4.6| 4.1| 3.2| 2.4| 1.8| 1.7| 1.6| 1.5
RSAE14- 40A| 3.2| 2.8| 2.0| 1.4| 0.9| NR| NR| NR
RSAE16- 40A| 2.1| 1.7| 1.0| 0.5| NR| NR| NR| NR
RSAE18- 40A| 1.1| 0.8| NR| NR| NR| NR| NR| NR
RSAE20- 40A| NR| NR| NR| NR| NR| NR| NR| NR
RSAE10- 40B| 10.1| 9.1| 7.6| 6.3| 5.3| 4.4| 4.2| 3.9
---|---|---|---|---|---|---|---|---
RSAE12- 40B| 7.6| 6.9| 5.6| 4.5| 3.7| 2.9| 2.8| 2.7
RSAE14- 40B| 5.8| 5.1| 4.0| 3.1| 2.4| 1.8| 1.6| 1.4
RSAE16- 40B| 4.3| 3.7| 2.7| 2.0| 1.3| 0.8| 0.5| NR
RSAE18- 40B| 3.0| 2.5| 1.7| 1.0| NR| NR| NR| NR
RSAE20- 40B| 1.9| 1.5| 0.7| NR| NR| NR| NR| NR
RSAE12- 40C| 10.3| 9.3| 7.7| 6.4| 5.3| 4.4| 4.2| 4.0
---|---|---|---|---|---|---|---|---
RSAE14- 40C| 8.0| 7.2| 5.8| 4.7| 3.8| 3.0| 2.8| 2.6
RSAE16- 40C| 6.2| 5.5| 4.3| 3.3| 2.5| 1.9| 1.7| 1.5
RSAE18- 40C| 4.6| 4.0| 3.0| 2.1| 1.5| 0.9| 0.7| 0.5
RSAE20- 40C| 3.3| 2.8| 1.9| 1.2| 0.6| NR| NR| NR
RSAE12- 50B| 13.2| 12.0| 9.9| 9.4| 8.0| 6.8| 5.9| 5.1
---|---|---|---|---|---|---|---|---
RSAE14- 50B| 10.4| 9.3| 7.5| 7.0| 6.3| 5.3| 4.5| 3.8
RSAE16- 50B| 8.0| 7.1| 5.6| 5.3| 4.9| 4.0| 3.3| 2.7
RSAE18- 50B| 6.1| 5.3| 3.9| 3.6| 3.3| 3.0| 2.3| 1.8
RSAE20- 50B| 4.4| 3.7| 2.9| 2.8| 2.7| 2.1| 1.5| 1.1
RSAE25- 50B| 1.3| 0.7| 1.0| 0.5| NR| NR| NR| NR
RSAE16- 60A| 9.3| 8.4| 6.8| 5.5| 4.5| 3.7| 2.9| 2.3
---|---|---|---|---|---|---|---|---
RSAE18- 60A| 7.4| 6.6| 5.3| 4.2| 3.3| 2.5| 1.9| 1.4
RSAE20- 60A| 5.9| 5.2| 4.0| 3.0| 2.2| 1.6| 1.0| 0.6
RSAE25- 60A| 3.0| 2.4| 1.5| 0.8| 0.2| NR| NR| NR
RSAE18- 60C| 16.5| 15.0| 12.4| 10.4| 8.7| 7.4| 6.2| 5.2
---|---|---|---|---|---|---|---|---
RSAE20- 60C| 13.8| 12.5| 10.3| 8.5| 7.0| 5.8| 4.8| 4.0
RSAE25- 60C| 9.0| 8.0| 6.3| 4.9| 3.8| 2.9| 2.1| 1.5
RSAE30- 60C| 5.6| 4.8| 3.5| 2.4| 1.5| 0.8| NR| NR

Wind-speed Website disclaimer

Current has no connection to the linked website and makes no representations as to its accuracy. While the information presented on this third-party website provides a useful starting point for analyzing wind conditions, Current has not verified any of the information on this third-party website and assumes no responsibility or liability for its accuracy. The material presented on the windspeed website should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability, and applicability by engineers or other licensed professionals.

Current Inc. does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the windspeed report provided by this website. Users of the information from this third-party website assume all liability arising from such use. Use of the output of these referenced websites do not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the windspeed report. http://windspeed.atcouncil.org

  1. Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30
  2. The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building The Wind Maps are intended only as a general guide and cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application
  3. Allowable pole EPA for job site wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled Responsibility lies with the specifier for correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty
  4. Wind speeds and listed EPAs are for ground-mounted Poles mounted on structures (such as bridges and buildings) and must consider vibration and coefficient of height factors beyond this general guide; Consult local and federal standards
  5. Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity Consult Current’s Pole Vibration Application Guide for environmental risk factors and design considerations:  http://images.salsify.com/image/upload/s–Uk0Lfj10–/bf7prkg0aey64uqoipso
  6. Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear, or other detrimental effects not included in wind velocity ratings

Due to our continued efforts to improve our products, product specifications are subject to change without notice. Unwrap poles immediately upon receipt to avoid condensation build-up and possible corrosion.

Note: There will be a weld witness mark on the side of the pole with the factory-installed VM2.

led.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications are subject to change without notice. All values are design or typical values when measured under laboratory conditions.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals