EVOLVE DOC-2003316 LED Roadway Light
Installation Guide
LED Roadway Light
- High Mast Luminaire (ERHM03)
BEFORE YOU BEGIN
- Read these instructions and save for future use.
RISK OF ELECTRIC SHOCK
Disconnect power before service installation, or maintenance of the product.
RISK OF INJURY OR DAMAGE
Unit will fall if not installed properly. Follow installation instructions.
CAUTION
Wear safety glasses and gloves during installationand servicing.
Storage & Handling
- Store packaged units in a covered dry area
- Check for damage
- Do not impact
- Do not stack
Mounting
- Mount on round tenon.
- Open cover.
- Open clamp to pipe OD.
- Insert pipe thru housing.
- Luminaire may be tilted with respect to pipe. Shift steps to level fixture front-to-back.
- Rotate to level side-to-side.
- Once level, tighten bolts evenly.
WARNING
- Do not torque bolts greater than 12 ft-lbs. (16.3 Nm). Damage may occur.
Wiring
RISK OF SHOCK OR DAMAGE
Follow applicable national and local electrical codes.
RISK OF DAMAGE
Verify supply voltage and wire insulation temperature rating match nameplate
requirements.
- Extend wires past pipe.
- Connect leads. Torque screws per Table 1.
- Gray / Pink Lead = 0V DC (-) Violet Lead = Up To 10V DC (+)
Table
Table
Cu| Al| Torque
10 – 16 AWG| –| 30
8 – 6 AWG| 6 AWG| 45
Dimming
Dimming
Voltage| Watts| Lumens
<1V| ~10% of Rated
9V| 100% Rated
- Linear Transition between Low and High.
- Tolerances may affect levels and linearity
Photoelectric Control
- Rotate receptacle to aim “N” to North.
- Lift, rotate, release, press to seat.
- Insert, twist to lock.
Final Assembly
- Close cover without pinching wires.
Rotating Optics for Asymmetric Distributions
- Loosen set screw.
- Rotate to desired orientation.
- Re-tighten the set screw.
NOTE: If rotation stop is reached, reverse direction to orient in desired direction.
Maintenance/Cleaning
RISK OF ELECTRICAL SHOCK
Make certain power is off before attempting any maintenance.
- Use mild soap/detergent.
- Rinse with cool low pressure water.
- Wipe dry with clean soft cloth.
Specifications
Luminaire ****
| Approx. Net Wt.| Dimensions **| IP Rating Classe IP**
| Effective Projected Area Zone de projection| Operating Temp.
---|---|---|---|---|---
ERHM
| ****
52 lbs (23.6 kg)
| Ø24.8 in. (630 mm)
x 9.7 in. (246 mm)
| ****
IP66 (Optical)
| ****
1.3 ft2 / 0.12m2 (max.)
| ****
-40°F TO +122°F / -40°C to +50°C
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference,
- this device must accept any interference received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme àla NMB-005 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.