EVOLVE ES Water Softeners Best Softener Companies Owner’s Manual

June 8, 2024
EVOLVE

EVOLVE ES Water Softeners Best Softener Companies

EVOLVE-ES-Water-Softeners-Best-Softener-Companies-PRODUCT-
IMAGE

Specifications

  • Model: Evolve Series
  • Water Test Parameters:
    • Hardness: __ gpg
    • Iron: __ ppm
    • pH: __
    • Nitrates: __ ppm (*Over 10 ppm may be harmful for human consumption)
    • Manganese: __ ppm
    • Sulphur: __ (yes/no)
    • Total Dissolved Solids: __

Product Information

Your Evolve Series softener is a precision-built, high-quality product designed to deliver softened water when properly installed and operated. Please read this manual thoroughly before installation. Keep it for future reference. For any queries, contact your local dealer.

Pre-Installation Instructions
The manufacturer has preset the water treatment unit’s cycle sequence, times, salt dose, exchange capacity, and refill time.

Follow these steps:

  • Dealer should…
  • Installer should…
  • Homeowner should…

General Operating Displays & Navigation
During normal operation, default displays show time of day and flow rate. Additional displays include capacity remaining and days to regeneration. Use the NEXT button to cycle through displays. In other screens, use REGEN to go back and CLOCK to return to general displays. Changes made will be saved if no buttons are pressed within five minutes.

Double Regeneration
To perform a double regeneration:

  1. Press REGEN once. “REGEN TODAY” will flash.
  2. Hold REGEN for three seconds to start regeneration.

The valve regenerates twice within 24 hours.

Bypass Valve
The bypass valve has two plug valves operated by red handles:

  1. NORMAL OPERATION: Handles point in flow direction for regular operation.

FAQ

  1. Q: How often should the water softener be regenerated?
    A: The water softener should typically be regenerated based on your water usage and the capacity of the unit. It is recommended to monitor and adjust regeneration frequency as needed.

  2. Q: Can the water softener remove nitrates from water?
    A: Water conditioners do not remove nitrates. Specialized equipment is required to eliminate nitrates from water.

Total Dissolved Solids ____

  • Over 10 ppm may be harmful for human consumption.
    Water conditioners do not remove nitrates or coliform bacteria, this requires specialized equipment.
    Look for our Evolve instructional videos on Youtube

PRODUCT INFORMATION
Installing Dealer must fill out this information prior to unit installation

  • MODEL NUMBER
  • SERIAL NUMBER
  • DEALER INFORMATION:

Your Evolve Series softener is a precision built, high quality product. These units will deliver softened water for many years to come when installed and operated properly. Please study this manual carefully and understand the cautions and notes before installing. This manual should be kept for future reference. If you have any questions regarding your water softener, contact your local dealer.

PRE-INSTALLATION INSTRUCTIONS

The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time.

THE DEALER SHOULD…

  • Read this page and guide the installer regarding hardness, day override and time of regeneration.

THE INSTALLER SHOULD…

  • Program installer settings including hardness, day override, and time of regeneration.
  • Read Operating Displays and Maintenance section.
  • Set the time of day
  • Read Power Loss and Error Display section.
  • Ensure that system and installation are in compliance with all state and local laws and regulations.

THE HOMEOWNER SHOULD…

  • Read Programming Procedures section.
  • Read Operating Displays and Maintenance section.

GENERAL OPERATING DISPLAYS & NAVIGATION
During normal operation, the default user displays are “time of day” and “gallons per minute”. Flow rate, capacity remaining, and days to a regeneration are optional displays. For more explanation, consult the “operating displays and maintenance section”. Pressing the NEXT button on a general operating screen will cycle through the available operating displays.
In any screen other than a general operating display, the NEXT button will proceed to the next step, the REGEN button will return to a previous step, and the CLOCK button will return to the general operating displays. Any changes made prior to the exit will be incorporated. If no buttons are pressed within five minutes, the display will return to the general operating displays.

DOUBLE REGENERATION
Two generations within 24 hours are possible with a return to the preset program.

To initiate a double regeneration:

  1. Press the REGEN button once. “REGEN TODAY” will flash on the display.
  2. Press and hold the REGEN button for three seconds until a regeneration begins.

Once the valve has completed the immediate regeneration, the valve will regenerate once more during the preset time.

BYPASS VALVE

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building. Be sure to install bypass valve onto main control valve before beginning plumbing or make provisions in the plumbing system for a bypass. The bypass body and rotors are glass-filled Noryl® and the nuts and caps are glass-filled polypropylene. All seals are self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings can easily be replaced if service is required.
The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles. The handles identify the direction of flow. The plug valves enable the bypass valve to operate in four positions.

  1. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener or filter. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. 1).

  2. BYPASS POSITION: The inlet and outlet handles point to the center of the bypass. The system is isolated from the water pressure in the plumbing system. Untreated water is supplied to the building (Fig. 2).

  3. DIAGNOSTIC POSITION: The inlet handle points toward the control valve and the outlet handle points to the center of bypass valve. Untreated supply water is allowed to flow to the system and to the building, while not allowing water to exit from the system to the building (Fig. 3). This allows the service technician to test the unit and perform other functions without disrupting the water going to the building.
    NOTE: The system must be rinsed before returning the bypass valve to the normal position.

  4. SHUT OFF POSITION: The inlet handle points to the center of the bypass valve and the outlet handle points away from the control valve. The water is shut off to the building. The water treatment system will depressurize upon opening a tap in the building. A negative pressure in the building combined with the unit being in regeneration could cause a siphoning to the building. If water is available on the outlet side of the unit, it is an indication of water bypassing the system (Fig. 4) (i.e. a plumbing cross-connection somewhere in the building).

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(1\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(2\)

INSTALLATION
GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water treatment unit is not designed to support the weight of the plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants, or spray silicone anywhere. A silicone lubricant may be used on black “O” Rings, but is not necessary. Avoid any type of lubricants, including silicone, on red or clear lip seals.
Do not use pipe dope or other sealants on threads. Teflon® tape must be used on the threads of the 1” NPT inlet and outlet and on the threads for the drain line connection. Teflon® tape is not used on the nut connections or caps because “O” Ring seals are used. The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic Service Wrench,

CV3193-02. If necessary, pliers can be used to unscrew the nut or cap. Do not

use a pipe wrench to tighten nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.

SITE REQUIREMENTS

  • Water pressure – 30-100 psi
  • Water temperature – 33-100°F (0.5-37.7°C)
  • Electrical – 115/120V, 60Hz uninterrupted outlet
  • Current draw is 0.5 amperes
  • The plug-in transformer is for dry locations only

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(3\)

WELL WATER INSTALLATION

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(4\)

MUNICIPAL INSTALLATION

  1. The distance between the drain and the water treatment unit should be as short as possible (see #9).

  2. Since salt must be added periodically to the brine tank, it should be in an easily accessible location.

  3. The media tank should be installed on a firm, level surface (above or below grade).

  4. It is NOT recommended to install any water treatment unit with less than 10 feet of piping between its outlet and the inlet of a water heater.
    CAUTION: To protect the unit in the event of a hot water heater backup, the manufacturer recommends the use of an expansion tank on the outlet side of the unit (see diagram).

  5. Do not locate unit where it or its connections (including the drain and overflow lines) will ever be subjected to temperatures under 33°F.

  6. Do not subject the tank to any vacuum as this may cause an “implosion” and could result in leaking. If there is a possibility a vacuum could occur, please make provision for a vacuum breaker in the installation.

  7. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. If it is desired to bypass outside hydrants, a cold water kitchen sink, or other locations, provisions should be made at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you face the unit. There are a variety of installation fittings available. They are listed under the Installation Fitting Assemblies section of the manual. When assembling the installation fitting package (inlet and outlet), connect the fitting to the plumbing system first and then attach the nut, split ring and “O” Ring. Heat from soldering or solvent cements may damage the nut, split ring or “O” Ring. Solder joints should be cool and solvent cements should be set before installing the nut, split ring and “O” Ring. Avoid getting solder flux, primer, and solvent cement on any part of the “O” Rings, split rings, bypass valve or control valve. If the building’s electrical system is grounded to the plumbing, install a copper grounding strap from the inlet to the outlet pipe. Plumbing must be done in accordance with all applicable local codes.

  8. INSTALLING GROUND: To maintain an electrical ground in metal plumbing of a home’s cold water piping (such as a copper plumbing system), install a ground clamp or jumper wiring.
    NOTE: If replacing an existing unit, also replace the ground clamps/wire. If removing a unit, replace the piping with the same type of piping as the original to assure plumbing integrity and grounding.

  9. DRAIN LINE: First, be sure that the drain can handle the backwash rate of the system. Solder joints near the drain must be done prior to connecting the drain line flow control fitting. Leave at least 6” between the drain line flow control fitting and solder joints. Failure to do this could cause interior damage to the flow control. Install a 1/2” I.D. tube to the Drain Line Assembly in accordance with plumbing regulations or discard the tubing nut and use the 3/4” NPT fitting for rigid pipe (recommended). If the backwash rate is greater than 7 gpm, use a 3/4” drain line. Where the drain line is elevated but empties into a drain below the level of the control valve, form a 7” loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve. This will provide an adequate anti-siphon trap. Piping the drain line overhead <10 ft is normally not a problem. Be sure adequate pressure is available (40-60 psi is recommended). Where the drain empties into an overhead sewer line, a sink-type trap must be used with appropriate air gap (see drawing). Run drain tube to its discharge point in accordance with plumbing codes. Pay special attention to codes for air gaps and anti-siphon devices.
    CAUTION: Never insert a drain line into a drain, sewer line, or trap. Always allow an air gap of 1-1/2” or twice the pipe diameter, whichever is greater, between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the softener.EVOLVE-ES-Water-Softeners-
Best-Softener-Companies-\(7\)

  10. SAFETY BRINE TANK CONNECTION: Install the 3/8” O.D. polyethylene tube from the Refill Elbow to the Brine Safety Float valve in the brine tank.EVOLVE-ES-Water-Softeners-Best-Softener-Companies-\(8\)

  11. OVERFLOW LINE CONNECTION: An overflow drain line is recommended where a brine overflow could damage furnishings or the building structure. Your unit is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow. In the event of a malfunction, however, an overflow line connection will direct the “overflow” to the drain instead of spilling on the floor where it could cause considerable damage. This fitting is an elbow on the side of the brine tank. Attach a length of 1/2” I.D. tubing to fitting and run to drain. Do not elevate overflow line higher than 3” below bottom of overflow fitting. Do not connect this tube into the drain line of the control valve. Overflow line must be a direct, separate line from overflow fitting to drain, sewer, or tub. The overflow line is a gravity drain and cannot run higher than the initial drain point. Allow an air gap as per the drain line instructions.

PROGRAMMING PROCEDURES

Set Time of Day
Typically, time of day should only need to be set after extended power outages or when daylight saving time begins or ends or after the battery has been replaced. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. To set the clock:

  • STEP 1 – Press the CLOCK button.
  • STEP 2 – Set the hour of the day using + or – buttons. AM/PM toggles after 12. Press NEXT to go to step 3.
  • STEP 3 – Set the minutes using + or – buttons. Press NEXT to go to step 4 or REGEN to return to previous step.
  • STEP 4 – Set the day of the week using + or – buttons. Press NEXT to exit clock setting or REGEN to return to previous step.

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(9\)

Programming

The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated after the hardness is entered. Press NEXT to cycle to the next step or REGEN to return to the previous step.

  • STEP 1 – Press and hold the NEXT and + buttons simultaneously for 3 seconds.
  • STEP 2 – HARDNESS: Use the + or – buttons to adjust the hardness value in grains per gallons. Adjustable from 1 to 150 gpg in 1 grain increments (default setting is 20).

The hardness value is based on the actual compensated hardness of the water and must be set by an authorized dealer following an on-site water analysis. Adjusting the number will only impact the frequency of regeneration and will not alter or affect the hardness of the water treated by the unit.
Note: If a resin media is used, increase the grains per gallon if soluble iron is present (1 ppm = 4 gpg). This screen will not display if “FILTER” mode is selected.

  • STEP 3 – DAYS BETWEEN REGENERATION (DAY OVERRIDE): Use the + or – buttons to adjust the day override. Adjustable from 1-28 days or OFF. The manufacturer has factory set 12 days as the default.

The Day Override value represents the maximum number of days between regenerations. If any number is set (1-28 days), a regeneration will be scheduled for that day if the gallon capacity has not been met. If OFF is set, the unit will only initiate a regeneration once the gallon capacity has been met.

  • STEP 4 – REGENERATION HOUR: Use the + or – buttons to adjust the time of day the unit will regenerate. AM/PM toggles after 12. The manufacturer has factory set 2:00 A.M. as the default setting which is recommended for a normal household.
  • STEP 5 – REGENERATION MINUTES: Use the + or – buttons to set minutes.
  • STEP 6 – BACKLIGHT DISPLAY CONTROL: Use the + or – buttons to turn the backlight setting ON or OFF. If unit is set to OFF, the backlight will turn off after 5 minutes of inactivity. This setting is not available on all models.

Press NEXT to return to General Display.

STARTUP INSTRUCTIONS FOR DOWNFLOW REGENERATING UNITS

FLUSHING OF SYSTEM:
To flush the system of any debris and air after installation is complete, please perform the following steps:

  1. Rotate bypass handles to the bypass mode (Fig. 2 on page 4) .
  2. Turn on inlet water and check for leaks in the newly installed plumbing.
  3. Fully open a cold water faucet, preferable at a laundry sink or bathtub without an aerator.
  4. Wait two to three minutes or until water runs clear, then turn water off and follow start-up instructions.

Below is the name of each cycle as it appears on the screen with a description of the cycle position. The timing of each cycle will vary depending on the unit size as set from the factory.

Name of Cycle   Description
FILL                         BRINE TANK FILL
SOFTENING           SOFT WATER BRINE MAKING
BACKWASH           BACKWASH
REGENERANT DRAW DN (DOWN) BRINE DRAW AND SLOW RINSE
RINSE                     FAST RINSE
The system is now ready for filling with water and for testing.

  1. With the softener in the bypass mode (Fig. 2 on page 4) and the control valve in normal operation where the display shows either the time of day or the gallons remaining, manually add 3” of water to the brine tank.
    NOTE: If too much water is put into the brine tank during softener start up, it could result in a “salty water” complaint after the first regeneration.
    During the first regeneration, the unit will draw out the initial volume of brine/regenerant and refill it with the correct preset amount.

  2. With the softener in bypass mode, press and hold the REGEN button until the motor starts. Release button. The display reads “FILL” and the remaining time in this step is counting down. Since the brine tank was already filled in Step 1, press REGEN again and the display will read SOFTENING 240 (During a full regeneration this will be a 4 hour period for salt to dissolve). Press REGEN again to put the valve into “BACKWASH.” Once valve has stopped in position, unplug the transformer so that the valve will not cycle to the next position. Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air.
    CAUTION: If water flows too rapidly, there will be a loss of media to the drain.

  3. When the water is flowing steadily to the drain without the presence of air, slowly open the inlet valve. Restore power and momentarily press the ????? button to advance the control to the “BRINE” position.

  4. With the bypass now in diagnostic mode (Fig. 3 on page 4), check to verify that water is being drawn from brine tank with no air leaks or bubbles in the brine line. There should be a slow flow to the drain. Disconnect brine line from the safety float valve in the brine tank and check for a vacuum. After proper confirmation, reconnect brine line making sure to insert properly.

  5. Momentarily press ????? again until the display reads “RINSE.” There should be a rapid flow to the drain. Unplug transformer to keep the valve in the “RINSE” position. Allow to run until steady, clear and without air. While the unit is rinsing, load the brine tank with water softener salt (Refer to Brine Tank Maintenance and Salt Section). Restore power.

  6. Place bypass valve in the normal operating mode (Fig. 1 on page 4) by opening the outlet bypass handle.
    Press ????? and the unit will return to the service position with time of day being displayed.

  7. CONDITIONING OF MEDIA:
    To flush any remaining debris and air from the system again:

  8. Full open a cold water faucet, preferably at a laundry sink or bathtub without an aerator.

  9. Wait two to three minutes or until water runs clear, then turn water off.

  10. Turn on hot water and check for air, then turn water off after air is discharged.

  11. SANITIZING OF UNIT UPON INSTALLATION AND AFTER SERVICE:
    At this time, it is advised to sanitize the softener:

  12. Open brine tank and remove brine well cover.

  13. Pour 1 oz. of household bleach into the brine well.
    NOTE: Avoid pouring bleach directly onto the safety float components in the brine well.

  14. Replace brine well cover.
    Unit sanitizing will be complete when the first cycle is run and the bleach is flushed from the unit.

  15. Check time of day. Start-up is now complete.

OPERATING DISPLAYS AND MAINTENANCE

GENERAL OPERATION: When the system is operating, one of five displays may be shown and will alternate with the installing dealer’s name and phone number for future service (if set). Pressing NEXT will alternate between the displays.

  1. Time of Day Screen: Displays the current time of day, the day of the week, and flow rate.
  2. Flow Rate Screen: Displays the current treated water flow rate through the system in Gallons Per Minute.
  3. Capacity Remaining Screen: Displays the amount of gallons of treated water remaining until the system triggers a regeneration.
  4. Days to a Regen Screen: Displays the number of days until the system triggers a regeneration. Based on the days override value.
  5. Dealer Name Screen: Displays dealer specific name and phone number. This scrolling display will only appear if set by the dealer.

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(13\)

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display. If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute flowing through the system.
REGENERATION MODE: Typically, a system is set to regenerate at a time of no water usage. If there is a demand for water when the system is regenerating, untreated water will be delivered. When the system begins to regenerate, the display will include information about the step of the regeneration process and the time remaining for that step to be completed. The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed.

MANUAL REGENERATION: Sometimes there may be a need to regenerate a unit before the control valve calls for it. This may be needed if a period of heavy water use is anticipated or when the system has been operating without salt.

  • To initiate a manual regeneration at the next preset regeneration time, press and release the REGEN button. The words “REGEN TODAY” will flash on the display to indicate that the system will regenerate at the scheduled regeneration time (see the Programming Procedures section). If you pressed the REGEN button in error, pressing and releasing the button again will cancel the command.
  • To initiate a manual regeneration immediately, press and hold the REGEN button for three seconds. The system will begin to regenerate immediately. This command cannot be canceled.

Once a manual regeneration is initiated, the unit will enter the FILL position. This position allows water to enter the brine tank until it reaches the proper level. Once this position is complete, you will notice a 240 minute (4 hours) SOFTENING position. This 4 hour window allows the salt to dissolve and achieve proper brine strength. During these FILL and SOFTENING positions, you will have softened water available for use. Once the unit advances to the BACKWASH position and subsequent positions thereafter (see Start Up Instructions for regeneration sequence), the unit will deliver water, but it will be untreated.
IMPORTANT: With the Dry Salt Storage Feature, the brine tank will refill 4 hours before the actual regeneration occurs. You may experience a small amount of noise for a short period of time at 10:00 p.m. (with factory settings) on the night that the regeneration is to occur. This noise is only the brine tank filling and at no time during this process will you be without treated water.
POWER LOSS AND BATTERY REPLACEMENT: If an extended power outage occurs, the control valve will retain the time of day settings until the board’s battery is depleted. Once the battery is depleted, the display will appear dark and absent of any information. If this occurs, following these steps will determine if the problem is a low battery or a board failure.

To determine if the battery is depleted:

  1. Remove valve cover. Disconnect power from PC Board at the four pin connector at the bottom of the board.

  2. Wait five minutes for board to de-energize. Remove battery with a non-conductive/non-metallic material. Reference the Parts Breakdown section of this manual for location.

  3. Wait five minutes for board to de-energize.

  4. With the battery out, re-connect the power supply to the board. The board’s display should begin to show information.
    This indicates that the board is operating correctly. If the display does not work, call installing dealer for service.

  5. To replace with new battery, unplug transformer from outlet. Install a 3 volt Lithium Coin Cell type 2032 battery, available at most stores. Plug unit back into outlet.
    It is important to replace the battery with the valve unplugged to avoid causing a short and potentially ruining the board.

  6. Reset the time of day (see programming procedures) and initiate regeneration (see operating displays and maintenance).
    If these procedures do not remedy the problem, please consult the installing dealer for service.

ERROR MESSAGE: If the word “ERROR” appears and flashes alternately with the dealer name and phone number, record the ERROR number and contact your servicing dealer promptly. This indicates that the control valve was not able to function properly.
BRINE TANK MAINTENANCE AND SALT: Refill the brine tank as necessary, making sure at least 1/3 of the brine tank is full at all times. Without proper salt levels, the water softener may not operate properly.

Because “typical” settings of this water softener include a dry salt storage feature (a small amount of water in brine tank between regeneration), the manufacturer recommends the use of solar salt for best results. The brine tank is manufactured for the use of solar, pellets or rock salt. Do not use block salt. If pellet or rock salt is used, a cleaning of the brine tank every six months is recommended. If the dry salt storage feature is not being utilized, block salt may be used.
Caution: With some models the manufacturer does NOT recommend the use of any resin cleaners, nor placing any resin cleaners into the brine tank. Furthermore, do not use any salt that indicates it is an iron cleaning salt or that contains any cleaning additives. This may be harmful to the water softener and for human consumption. Consult dealer for proper cleaning instructions.

TROUBLESHOOTING GUIDE

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(19\)EVOLVE-ES-Water-Softeners-
Best-Softener-Companies-\(20\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(21\) EVOLVE-ES-Water-Softeners-
Best-Softener-Companies-\(22\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(23\) EVOLVE-ES-Water-Softeners-
Best-Softener-Companies-\(24\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(25\) EVOLVE-ES-Water-Softeners-
Best-Softener-Companies-\(26\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(27\)

REPLACEMENT PARTS

FRONT COVER AND DRIVE ASSEMBLY

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3367-01-A| 100246343| Evolve Black cover assembly| 1
CV3367-01WR-A| 100246345| Evolve Gray cover assembly| 1
2| CV3107-1| 100246273| Motor Assembly| 1
3| CV3002-A| 100246193| Drive assembly (includes #5 and #6)| —
4| CV4229XP-03| 100243791| PC Board, Evolve ES| 1
5| CV3110| 100246279| Drive gear, 12 x 36| 3
6| CV3109| 100246278| Drive gear cover| 1
not shown| CV3186-06| 100249863| Transformer, 110V-12V (standard)| 1
CV3684-WR-GLD| 100244240| Optional weather cover| 1

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(28\)

PISTON ASSEMBLY

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3005-02| 100249844| 1” spacer stack assembly| 1
CV3430-01| 100249865| 1.25” spacer stack assembly| 1
2| CV3004| 100246196| Drive cap assembly| 1
3| CV3135| 100246281| O-ring 228 (drive cap o-ring)| 1
4| CV3011| 100246232| 1” piston assembly downflow| 1
CV3011-01| 100246233| 1” piston assembly upflow| 1
CV3407| 100243924| 1.25” piston assembly downflow| 1
5| CV3174| 100246296| Regenerant piston| 1
**** 6| CV3001- 04| 100244557| 1” body assembly downflow| 1
CV3001-04UP| 100243827| 1” body assembly upflow| 1
CV3020| 100246239| 1.25” body assembly downflow| 1
7| CV3368| 100246346| Drive backplate| 1
not shown| CD1225-05| 100249834| Top basket softener (optional)| 1

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(29\)

TANK O-RINGS

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3180| 100246307| Base O-Ring| 1
**** 2| CV3105| 100246272| O-Ring 215| 1
CV3358| 100246341| O-Ring 219 (for 1.25” distributor tubes)| 1

BYPASS VALVE

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3006| 100249845| Bypass assembly| 1
2| CV3147| 100246284| Bypass handles| 2

REFILL PORT ASSEMBLY

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3195-01| 100246323| Refill port plug assembly| 1
2| CH4615| 100245862| Elbow locking clip| 1
3| CV4144| 100245015| 3/8” Elbow, Parker fitting| 1
4| CV3163| 100246291| O-ring 019| 1

SERVICE WRENCH – 100249864 (CV3193-02)
Although no tools are necessary to assemble or disassemble the valve, the Service Wrench, (shown in various positions on the valve) is available to aid in assembly or disassembly.

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(33\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(62\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(34\)

WATER METER AND METER PLUG

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CV3151| 100246287| Nut, 1” Quick Connect| 1
2| CV3003| 100246194| Meter assembly| 1
3| CV3003-01| 100246195| Meter plug assembly| 1

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(35\)

DRAIN LINE ASSEMBLY 3/4”

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CH4615| 100245862| Elbow locking clip| 1
2| CPKP10TS8-BULK| 100245919| Optional insert, 5/8” tube| 1
3| CV3192| 100246322| Optional nut, 3/4” drain elbow| 1
4| CV3158-02| 100249851| Drain elbow, 3/4” NPT with O-ring (w/o silencer)| 1
5| CV3163| 100246291| O-ring 019| 1
6| CV3159-01| 100246290| DLFC retainer assembly| 1
7| CV3162-007| 100244908| 0.7 DLFC for 3/4” elbow| 1
CV3162-010| 100244909| 1.0 DLFC for 3/4” elbow
CV3162-013| 100244910| 1.3 DLFC for 3/4” elbow
CV3162-017| 100244911| 1.7 DLFC for 3/4” elbow
CV3162-022| 100249852| 2.2 DLFC for 3/4” elbow
CV3162-027| 100249853| 2.7 DLFC for 3/4” elbow
CV3162-032| 100249854| 3.2 DLFC for 3/4” elbow
CV3162-042| 100249855| 4.2 DLFC for 3/4” elbow
CV3162-053| 100249856| 5.3 DLFC for 3/4” elbow
CV3162-065| 100249857| 6.5 DLFC for3/4” elbow
CV3162-075| 100249858| 7.5 DLFC for 3/4” elbow|
8| CV3331A| 100245051| Drain elbow and retainer assembly (requires DLFC)|
Items 2 and 3, nut and insert are only used with 1/2” I.D. by 5/8” O.D. polytubing. For other piping material, the 3/4” NPT is used.
DRAIN LINE ASSEMBLY 1”

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CH4615| 100245862| Elbow locking clip| 1
2| CV3166| 100246292| Drain FTG body 1| 1
CV3166-01| 100246293| FTG flow control body 1
3| CV3163| 100246291| O-ring 019| 1
4| CV3150| 100246286| Split ring| 1
5| CV3151| 100246287| Nut 1″ QC| 1
6| CV3105| 100246272| O-ring 215| 1
7| CV3190-090| 100246313| 9.0 gpm DLFC for 1” elbow| One DLFC must be used if 1″ fitting is used
CV3190-100| 100246314| 10.0 gpm DLFC for 1” elbow
CV3190-110| 100246315| 11.0 gpm DLFC for 1” elbow
CV3190-130| 100246316| 13.0 gpm DLFC for 1” elbow
CV3190-150| 100246317| 15.0 gpm DLFC for 1” elbow
CV3190-170| 100246318| 17.0 gpm DLFC for 1” elbow
CV3190-200| 100246319| 20.0 gpm DLFC for 1” elbow
CV3190-250| 100246320| 25.0 gpm DLFC for 1” elbow
8| CV3008-04| 100243824| FTG Drain 1″ Strt No/Silencer (requires DLFC)| 1

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(36\)

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(37\)

BRINE TANK ASSEMBLY (EV)

Item #| Legacy Part #| Current Part #| Description| Qty.
1| CG2191-92| 100245811| Brine tank cover, injection molded EV| 1
2| CH1095-01| 100245856| Optional 18” diameter salt grid| 1
CH1080| 100245853| Optional 24” diameter salt grid (Does not include 1 1/2” PVC riser legs)| 1
3| BT1833-1A| 100245568| 18” x 33” brine tank assembly| 1
BT1840-1A| 100245574| 18” x 40” brine tank assembly| 1
BT2441-1A| 100245576| 24” x 41” brine tank assembly| 1
4| CH1030-29S| 100245837| 4” x 29” slotted brine well (18 x 33 BT)| 1
CH1030-36S| 100245841| 4” x 36” slotted brine well (18 x 40, 24 x 40 BTs)| 1
5| CH1018| 100245836| 2 piece overflow set| 1
6| CH4500-48| 100245857| 474 air check assembly, 1/2” x 48”| 1
7| CH4600-50| 100245860| 474 safety brine valve w/ .5 gpm flow control| 1
8| CH7016| 100245880| Cap 4” brine well| 1
9| CH4626| 100245864| Nut safety brine valve stand off| 1
Assemblies
10| CH4700-29WR-1| 100244899| .5 gpm safety float assembly, 18” x 33”|
CH4700-36.5WR-1| 100245872| .5 gpm safety float assembly, 18” x 40”|

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(38\)

SAFETY FLOAT BRINE ELBOW

Item #| Legacy Part #| Current Part #| Description| Qty.
| CV4144| 100245015| 3/8” elbow cap, Parker fitting (no flow control)| 1
CV4144-03| 100242646| 3/8” elbow cap, Parker fitting (w/flow control)| 1
CH4612| 100245861| 1/2” elbow cap| 1

INSTALLATION FITTING ASSEMBLIES

NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings.

For All Assemblies

Item # 1| Legacy Part #
CV3151| Current Part #
100246287| Description
Nut, 1” quick connect| Qty.
2
---|---|---|---|---
2| CV3150| 100246286| Split ring| 2
3| CV3105| 100246272| O-ring 215| 2

Legacy Part # Current Part # Description Qty.
CV3007 100246197 1” PVC male NPT elbow assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-01 100246198 3/4” & 1” PVC solvent elbow assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-02 100246199 1” brass sweat assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-03 100249846 3/4” brass sweat assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-04 100244506 1” plastic male NPT assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-05 100243921 1-1/4” plastic male assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-09 100243922 1-1/4” & 1-1/2” brass sweat assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-12 100249847 3/4” brass shark bite assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-13 100249848 1” brass shark bite assembly 2
Legacy Part # Current Part # Description Qty.
CV3007-17 100245045 1” john guest assembly 2

SPECIFICATIONS

ES-Specifications

MODEL| ES-844| ES-948| ES-1044| ES-1054| ES-1252| ES-1354
---|---|---|---|---|---|---
Rated Softener Capacity:* (Grains/Lbs. Salt)| Minimum| 13,700 @ 3.4| 18,200 @ 4.5| 18,200 @ 4.5| 27,600 @ 7.0| 36,400 @ 9.0| 45,800 @ 11.5
Medium| 16,800 @ 6.0| 23,500 @ 9.0| 23,500 @ 9.0| 36,700 @ 15.0| 47,000 @ 18.0| 53,900 @ 18.0
Maximum| 18,800 @ 8.0| 28,000 @ 15.0| 28,000 @ 15.0| 42,000 @ 22.5| 56,100 @ 30.0| 69,800 @ 37.0
Efficiency at 1 lb Salt Setting (Grains/Lbs. Salt)| 4,042/1| 4,042/1| 4,042/1| 4,042/1| 4,042/1| 4,042/1
Max. Service Flow Rate (GPM)| 11.7| 13.1| 16.0| 13.3| 16.4| 17.1
Max. Pressure Loss at Max. Service (PSI)| 15| 15| 15| 15| 15| 15
Min. to Max. Working Pressure (PSI)| 30-100| 30-100| 30-100| 30-100| 30-100| 30-100
Min. to Max. Operating Temperature (ºF)| 33-100| 33-100| 33-100| 33-100| 33-100| 33-100
Max. Flow to Drain During Regeneration (GPM)| 1.3| 1.7| 2.2| 2.2| 3.2| 3.2
Amount of High Capacity Cat-ion Resin (Cu. Ft.)| .75| 1.0| 1.0| 1.5| 2.0| 2.5
Electrical Requirements (volts-hertz)| 110-50/60| 110-50/60| 110-50/60| 110-50/60| 110-50/60| 110-50/60
Pipe Size| 1”| 1”| 1”| 1”| 1”| 1”
**** Total Dimensions:| Media Tank and Valve| 8”W x 52”H| 9”W x 56”H| 10”W x 52”H| 10”W x 62”H| 12”W x 60”H| 13”W x 62”H
Brine Tank| 18”W x 33”H| 18”W x 33”H| 18”W x 33”H| 18”W x 33”H| 18”W x 40”H| 18”W x 40”H

All Evolve ES water softeners are set at “medium salting” from the factory.

Evolve Series® Water Softener Limited Warranty

Congratulations. You have purchased one of the fi nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, Water-Right® proudly warrants our Evolve Series® water softeners to the original owner, at original installation location, when installed in accordance with Water-Right specifications from the date of original installation as follows:
For the LIFETIME of the original owner: Media tank, except for damages due to freezing, high pressure (120 PSI and above), extreme temperature (100° F and above) or a vacuum on the system.

  • For a period of TEN YEARS: Brine tank.
  • For a period of FIVE YEARS: Complete valve.
  • For a period of ONE YEAR: All other parts and components.

Any part found defective within the terms of this warranty will be repaired or replaced by the dealer at the manufacturer’s discretion. You pay only freight from our factory and local dealer charges. To obtain local warranty service, contact original dealer. If original dealer is unknown, contact Water-Right for authorized service dealer in your area. If no authorized dealer is located in your area, please ship defective part or component freight prepaid to:
Water-Right, Inc.
1900 Prospect Ct. Appleton, Wisconsin 54914
Water-Right, at its discretion, will repair or replace the part or component at its expense and return part freight collect.
The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition of the original installation and is owned by the original owner.
This warranty does not cover expendable or misapplied medias, or damages due to accident, fi re, fl ood, freezing, or any other Act of God. Water-Right is not responsible for damages due to change in water conditions, misapplication, misuse, neglect, vacuum, oxidizing agents, alteration, or lack of maintenance. No responsibility is assumed for loss of use of the unit, inconvenience, loss or damage to real or personal property or any incidental or consequential damages. Furthermore, we assume no liability and extend no warranties, express or implied, for the use of this product with a non-potable water source. To the extent permitted by law, Water-Right disclaims all implied warranties, including without limitation warranties of merchantability and fi tness for particular purpose; to the extent required by law, any such implied warranties are limited in duration to the period specifi ed above for the specifi ed components.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.

QUICK REFERENCE GUIDE

GENERAL OPERATION
When the system is operating, one of four displays will be shown:

  1. Time of day/gpm
  2. Flow rate
  3. Capacity remaining
  4. Days to a regen

Pressing NEXT will toggle between the four choices.

TO SET TIME OF DAY
In the event of a prolonged power outage, time of day flashes, indicating that this needs to be reset. All other information will be stored in memory no matter how long the power outage.

  1. Accessed by pressing CLOCK
  2. Adjust hours with + or — buttons, AM/PM toggles at 12
  3. Press NEXT
  4. Adjust minutes with + or — buttons
  5. Press NEXT
  6. Adjust current day with + or — buttons
  7. Press NEXT to complete and return to normal operation

MANUAL REGENERATION
NOTE: If you need to initiate a manual regeneration, either immediately, or the same night at the pre-programmed time for regeneration (typically 2:00 AM), complete the following steps.

For Immediate Regeneration:
Press and hold REGEN until valve motor starts (typically 3 seconds).

For Regeneration the same night:
Press and release REGEN (notice that flashing “REGEN TODAY” appears).

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(55\)

ERROR
If the display toggles between “Error” and an error code (i.e. a number), call a service technician and report the error code.

BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in the bypass operation diagram below. If your valve doesn’t look like the diagram below, contact your service technician for instructions on how to shut off water.

EVOLVE-ES-Water-Softeners-Best-Softener-
Companies-\(57\)

ADJUST HARDNESS, DAYS BETWEEN REGENERATION, AND TIME OF REGENERATION

For initial set-up or to make adjustments, please complete the following steps.

  1. Accessed by pressing NEXT and + button simultaneously
  2. Adjust hardness using + or — buttons
  3. Press NEXT
  4. Adjust days between regenerations using + or — buttons
  5. Press NEXT
  6. Adjust time of regeneration hour with + or — buttons, AM/PM toggles at 12.
  7. Press NEXT
  8. Adjust time of regeneration minutes with + or — buttons
  9. Press NEXT
  10. Turn display backlight ON or OFF with + or — buttons. Default is ON.
  11. Press NEXT to complete and return to normal operation.

© 2021 Evolve All rights reserved. MAN-EV ES SOFT RevA0124
Manufactured exclusively for Evolve Dealers at: 1900 Prospect Court • Appleton, WI 54914
Phone: 920-739-9401
Fax: 920-739-9406

Love your Evolve Softener? Scan the QR code above with your mobile device to leave a review.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals