LEVITON PK-93456 50a Locking Flanged Inlets 3 Wire Instruction Manual

May 15, 2024
Leviton

LEVITON PK-93456 50a Locking Flanged Inlets 3 Wire

Product Information

Specifications

  • Color : Black & White
  • Model Number : PK-93456-10-02-0C
  • Power Rating : 50A
  • Locking Flanged Inlets : 3 Wire and 4 Wire

Product Usage Instructions

Installation
WARNING : To avoid fire, shock, or death, turn off power at circuit breaker or fuse and test that power is off before wiring!
CAUTION : To be installed and/or used in accordance with appropriate electrical codes and regulations.

Conductor Color Codes

Conductor Color Couleurs des conducteurs Color de Conductor
G, GRND, GREEN, or Eq G (Grounding terminal) Bare, Green, or Green/Yellow
wire G, a GRND, GREEN, o Eq. G (Terminal a tierra)
W, or WHITE (Neutral terminal) White or Gray wire Blanc ou gris
X, Y, Z, or BLANK (Hot terminal) No specific color X, Y, Z, ou sans marque

(borne active)

Locking Connector
Use the provided dimensions for cuts and perforations.

Locking Plug
Connect the locking plug to the appropriate terminals following the conductor color codes.

Locking Receptacle
Connect the locking receptacle to the appropriate terminals following the conductor color codes.

Application
This product is suitable for use with 50A, 2 Pole, 3 Wire, 250 V DC/600 V AC or 50A, 3 Pole, 4 Wire, 250 V DC/600 V AC configurations.

FAQ

  • Q: How do I install the product?
    A: Follow the installation instructions provided in the user manual. Make sure to turn off power at the circuit breaker or fuse before wiring.

  • Q: What are the conductor color codes?
    A: The conductor color codes are as follows

    • G, GRND, GREEN, or Eq G (Grounding terminal): Bare, Green, or Green/Yellow wire
    • W, or WHITE (Neutral terminal): White or Gray wire
    • X, Y, Z, or BLANK (Hot terminal): No specific color
  • Q: What is the power rating of the product?
    A: The power rating is 50A.

black & white

  • 50A Locking Flanged Inlets
  • 3 Wire and 4 Wire

Installation Instructions

TRADEMARK DISCLAIMER : Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.

FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance Department, 165 Hymus Blvd,
Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.

LIMITED LIFETIME WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use during the lifetime of the product. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com

INSTALLATION INSTRUCTIONS

WARNING : TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING
CAUTIONS :TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.

  • IF YOU ARE UNSURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
  • USE THIS DEVICE ONLY WITH COPPER WIRE.
  • ENSURE THAT LOCKING FLANGED INLET HAS THE PROPER ELECTRICAL RATING FOR THE SYSTEM ON WHICH IT IS BEING INSTALLED.
  • DEVICES ARE FOR GROUNDING CIRCUITS, OR EQUIPMENT GROUNDING ONLY. DO NOT USE IN NON-GROUNDING APPLICATIONS.
  • THE ENCLOSURE USED TO INSTALL THE LOCKING FLANGED INLET MUST BE APPROPRIATE FOR THE LOCATION BEING SERVED (DRY, WET, DAMP).

NOTE : WIRE SIZE AND TYPE MUST COMPLY WITH APPROPRIATE LOCAL ELECTRICAL CODES. IN USA REFER TO NEC TABLES ARTICLE 400.
NOTE : LEVITON’S LOCKING FLANGED INLETS ARE DESIGNED TO ACCEPT WIRES FROM

10 AWG TO #4 AWG.

TO INSTALL

  1. WARNING : TO AVOID FIRE, SHOCK, OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
  2. Strip insulation of each conductor 3/4″ (19.1 mm) per STRIP GAGE molded on the back cover of the Flanged Inlet.
  3. Make sure that stripped wire is clean, and of a bright copper color. If necessary, twist strands of each stripped conductor tightly. DO NOT TIN CONDUCTORS.
  4. NOTE : DO NOT LOOSEN TERMINAL SCREWS.
  5. Insert each stripped conductor into proper wiring well per Table 1, and per markings on device. Check for stray wire strands.
  6. Tighten each terminal to 35 in-lb of torque, using a 5/32″ Allen wrench. CAUTION: TERMINAL MUST TIGHTEN ONTO CONDUCTORS, NOT INSULATION.
  7. Mount Locking Flanged Inlet on panel cut-out per Figure 1.

Figure 1 – Panel Mount Dimensions

Use dimensions for cut-out and drilling purposes

This device is for replacement use only in existing installations

Read User Manual Online (PDF format)