HOUSEGARD FE6HR-B Foam Extinguisher User Manual

June 15, 2024
HOUSEGARD

HOUSEGARD FE6HR-B Foam Extinguisher

HOUSEGARD-FE6HR-B-Foam-Extinguisher-PRODUCT

Product Information

Specifications

  • Product Name: Foam extinguisher FE6HR-B
  • Model: Ver: 230704
  • Intended Use: Extinguishing fires in various materials such as wood, paper, fibrous materials, flammable liquids, chemicals, and electrical installations up to 1000 Volts

Product Usage Instructions

Checking and Inspecting the Fire Extinguisher:

When unpacking the extinguisher, please follow these steps:

  1. Check that the manometer needle points in the green sector.
  2. Verify that the safety pin is mounted and sealed.
  3. Ensure that the hose is mounted. If not, attach the hose.

Note: Visual inspection of the fire extinguisher is the user’s responsibility to ensure that the pressure of the extinguisher is at a satisfactory level.

How Foam Extinguishes Fires:

The foam extinguisher uses foam concentrate to extinguish fires.

The foam works in the following ways:

  • Creates a smothering film that starves the fire of oxygen.
  • Has a cooling effect on the fire.
  • Prevents the burning material from being reignited.

Fire Classes

The fire extinguisher is suitable for extinguishing fires in different classes:

  • Class A – Organic materials such as wood, paper, textiles, etc.
  • Class B – Liquid fires such as oil, gasoline, varnish, paint, etc.

Important Information

When approaching a fire, always follow these precautions:

  • Do not go too close and maintain a safety distance of at least 1 meter.
  • Check possible escape routes before attempting to approach the fire.
  • Avoid approaching the fire if there is a risk of it spreading and blocking your escape route.

How to Operate Your Fire Extinguisher

Follow these steps to use your foam extinguisher:

  1. Pull out the safety pin to free the lever.
  2. Aim the nozzle or hose at the base of the fire.
  3. Squeeze the handle to release the firefighting agent.
  4. Sweep the nozzle or hose across the base of the fire until it is fully extinguished.

Maintenance and Inspection:

For proper maintenance and inspection, please adhere to the following guidelines:

  • In private residences, it is recommended to have an authorized inspection every 5 years.
  • A full service should also be conducted every 5 years.
  • All maintenance must be done according to national standards.

Note: The extinguisher must always be recharged after any use, even if only parts of the contents have been used. Recharging requires special equipment and training. Please contact an authorized service center.
Use only HOUSEGARD-specified foam and spare parts.

FAQ:

Q: How often should I inspect my foam extinguisher?

  • A: It is recommended to have an authorized inspection every 5 years for private residences.

Q: How often should I recharge the extinguisher?

  • A: The extinguisher must be recharged after any use, even if only parts of the contents have been used.

Q: Can I use any foam concentrate in the extinguisher?

  • A: No, use only HOUSEGARD-specified foam and spare parts.
  • IMPORTANT! Read these instructions carefully before using the device. Keep it for future reference. Your new foam extinguisher contains a foam concentrate intended for extinguishing fires in various materials such as wood, paper, fibrous materials, flammable liquids, and chemicals.
  • This fire extinguisher can also be used on fires in electrical installations up to 1000 Volts. Always keep a safety distance of at least 1 meter.

THIS PACKAGING CONTAINS

  • Fire extinguisher, 1 pcs
  • Wall bracket, 1 pcs
  • Hose, 1 pcs
  • User manual, 1 pcs

CHECKING AND INSPECTING THE FIRE EXTINGUISHER

  • When unpacking the extinguisher, please check that the manometer needle points in the green sector. Check that the safety pin is mounted and sealed. Make sure that the hose is mounted. If not, attach the hose.
  • IMPORTANT: Visual inspection of the fire extinguisher is the user’s responsibility, for example, that the pressure of the extinguisher is at a satisfactory level.

HOW FOAM EXTINGUISHES FIRES

  • The foam creates a smothering film and starves the fire of oxygen. It also has a cooling effect on the fire. The foam also prevents the burning material from being reignited.

FIRE CLASSES:

  • Fire extinguishers are classed using a letter-symbol system which denotes the type of fire they are suitable to extinguish.
  • Class A – Organic materials such as wood, paper, textiles, etc.
  • Class B – Liquid fires such as oil, gasoline, varnish, paint, etc.

IMPORTANT INFORMATION

  • Always use caution when approaching a fire. Do not go too close to the fire and keep a safety distance of at least 1 meter. Always check the possible escape routes first.
  • Do not try to approach the fire in case there is a risk that it can spread so that your escape route is blocked.

HOW TO OPERATE YOUR FIRE EXTINGUISHER

  • Pull out the safety pin, to free the lever.
  • Aim the nozzle or hose at the base of the fire.
  • Squeeze the handle to release the firefighting agent.
  • Sweep the nozzle or hose across the base of the fire until it is fully extinguished.

MAINTENANCE AND INSPECTION

  • In private residences, an authorized inspection is recommended every 5 years, and a full service every 5 years.
  • All maintenance must be done according to national standards.

REGULAR SELF-MONITORING

  • Check that the extinguisher is correctly located in the designated place.
  • Make sure the fire extinguisher is intact and without visible damage.
  • Check that the manometer needle points in the green sector.
  • Check that the safety pin is in place and sealed.
  • IMPORTANT: The extinguisher must always be recharged after any use, even if only parts of the contents have been used.
  • Recharging requires special equipment and training, Contact an authorized service center.
  • Use only HOUSEGARD-specified foam and spare parts.

IMPORTANT SAFETY INFORMATION

  • The extinguisher is pressurized. DO NOT incinerate. Do not subject to external force or open forcibly.
  • Damaged or corroded extinguishers must be depressurized before disposal.
  • Service should only be performed by authorized personnel.
  • Make sure the fire extinguisher is suitable for the intended area of use.
  • For more information, see the label of the extinguisher.
  • Never aim the extinguisher’s nozzle at people or animals.
  • Keep the extinguisher clean. Do not use corrosive cleaning agents.
  • Fire extinguishers in vehicles must be securely fastened using a suitable bracket.
  • The fire extinguisher should be kept out of reach for young children.
  • This extinguisher contains a blended foam concentrate. It is nontoxic but can irritate the eyes and skin.
  • First   aid: Eyes: Flush with water for ten minutes. Skin: Wash thoroughly with soap and water. If inhaled: Breathe fresh air and rest.
  • If swallowed: Drink two glasses of water. If symptoms of irritation remain, consult a doctor.
  • Must not be discarded in the normal household waste. On disposal, provide fire extinguishers to your recycling center.
  • Evocolit Class AB Green PFC free does not contain per- and polyfluoroalkyl substances (PFAS).

TECHNICAL SPECIFICATIONS

HOUSEGARD FE6HR-B

  • Model: Housegard FE6HR-B
  • Type: 6 L AB Foam, stored pressured.
  • Fire class: AB
  • Fire rating: 21A-183B
  • Total weight: 9,6 kg
  • Pressurization: 12 Bar
  • Propellant: Nitrogen N2
  • Foam: Evocolit CLASS AB GREEN-PFC free 20
  • Approvals: EN3-7, CE, Wheelmark.
  • Operating temperature: +0 °C to +60 °C

WARRANTY

  • A 5-year warranty applies to pressure drops. The warranty is valid for 5 years calculated from the product’s month of production.
  • The warranty requires that the original seal is intact and that the product has not been opened, used, refilled, or gone through service that has resulted in physical intervention of the product.
  • The warranty applies only when the product is used and stored under normal conditions and environment.
  • The warranty does not apply if the product is stored in corrosive or otherwise unfavorable or stressful environments, or otherwise considered to be damaged by its storage or use.
  • For more information, please visit www.housegard.com

The Green initiative

  • Our vision is to be the leader in sustainability within our industry and the driving force towards environmentally responsible actions.
  • Discover our extensive collection of fire extinguishers, all of which are free from PFAS, ensuring a safer and greener approach to fire safety.
  • © 2023 GPBM Nordic AB. All rights reserved. Supplementary information about the product can be found at www.housegard.com

Documents / Resources

| HOUSEGARD FE6HR-B Foam Extinguisher [pdf] User Manual
FE6HR-B Foam Extinguisher, FE6HR-B, Foam Extinguisher, Extinguisher
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals