Product Information
Specifications
- Model: Economy Series
- Thermostat Models Covered: 2030 1 Heat / 1 Cool Conventional or Heat Pump, 2230 Up to 2 Heat / 1 Cool Conventional or Heat Pump
Features
- Easy-to-use thermostat
- Provides years of reliable performance and comfort control
About Your Thermostat
The thermostat and display have the following buttons
-
BACK Button* – Secondary function of the PROG button, moves to the previous setting
-
HOLD Button – Enters / Exits the HOLD mode (program bypass mode)
-
Battery Compartment – Located on the back side of thermostat (if installed)
-
BACK and NEXT are secondary functions of the PROG and HOLD buttons. When in programming or configuration modes, BACK and NEXT appear in the display screen indicating that the PROG and HOLD now function as BACK and NEXT.
User Settings
User Settings allow you to set the current time of day and customize
various thermostat features. To access the User Settings
- Press and release the MENU button to display the first User Setting.
- Press the “+” or “-” buttons to change the value for the displayed User Setting.
- After your desired setting is displayed, press NEXT (HOLD) to advance to the next User Setting. You may also press BACK (PROG) to move backwards through the User Settings.
- You will exit the user settings after the last setting.
Product Usage Instructions
Setting Your Program Schedule
Prior to setting your program schedule, consider the following tips
- Read all instructions before proceeding.
- Store this manual for future reference.
Programming a 7 Day Schedule
To program a 7 day schedule
- Follow the steps in the User Settings section to access the programming mode.
- Press the MENU button to display the first program event.
- Use the “+” and “-” buttons to set the desired temperature and time for each program event.
- Repeat steps 2-3 for each program event.
- Exit the programming mode when finished.
Programming a 5-2 Day Schedule
To program a 5-2 day schedule
- Follow the steps in the User Settings section to access the programming mode.
- Press the MENU button to display the first program event.
- Use the “+” and “-” buttons to set the desired temperature and time for each program event.
- Repeat steps 2-3 for each program event.
- Exit the programming mode when finished.
Operating Your Thermostat
Setting the System Control Mode
To set the system control mode
- Press the MENU button to access the system control mode.
- Use the “+” and “-” buttons to select the desired system control mode (e.g., heat, cool, auto).
- Exit the system control mode when finished.
Setting the Fan Control Mode
To set the fan control mode
- Press the MENU button to access the fan control mode.
- Use the “+” and “-” buttons to select the desired fan control mode (e.g., on, auto).
- Exit the fan control mode when finished.
Temperature Adjustment
To adjust the temperature
- Press the MENU button to access the temperature adjustment mode.
- Use the “+” and “-” buttons to increase or decrease the temperature.
- Exit the temperature adjustment mode when finished.
Program Event Indicators
The thermostat displays indicators to show program events. Refer to the
user manual for a detailed explanation of each indicator.
System Status and Maintenance Indicators
The thermostat displays indicators to show system status and maintenance
information. Refer to the user manual for a detailed explanation of each
indicator.
Additional Operation Features
Adaptive Recovery Mode
The thermostat has an adaptive recovery mode that learns how long it takes
to reach the desired temperature and adjusts the system accordingly.
Compressor Protection
The thermostat has a compressor protection feature that prevents short
cycling of the compressor, extending its lifespan.
Thermostat Maintenance
Battery Replacement
To replace the batteries
- Open the battery compartment located on the back side of the thermostat.
- Remove the old batteries and dispose of them properly.
- Insert new batteries according to the polarity markings.
- Close the battery compartment.
Thermostat Cleaning
To clean the thermostat
- Turn off the thermostat.
- Use a soft, dry cloth to gently clean the display and buttons.
FAQ
-
Q: What thermostat models are covered by this manual?
A: This manual covers the following thermostat models: 2030 1 Heat / 1 Cool Conventional or Heat Pump, 2230 Up to 2 Heat / 1 Cool Conventional or Heat Pump. -
Q: How do I access the User Settings?
A: To access the User Settings, press and release the MENU button to display the first User Setting. Use the “+” and “-” buttons to change the value for the displayed User Setting. Press NEXT (HOLD) to advance to the next User Setting or BACK (PROG) to move backwards through the User Settings. You will exit the user settings after the last setting. -
Q: How do I program a schedule?
A: To program a schedule, follow the steps provided in the “Setting Your Program Schedule” section of the user manual. There are instructions for programming a 7 day schedule and a 5-2 day schedule. -
Q: How do I adjust the temperature?
A: To adjust the temperature, press the MENU button to access the temperature adjustment mode. Use the “+” and “-” buttons to increase or decrease the temperature. Exit the temperature adjustment mode when finished.
Congratulations! You are in control of one of the easiest-to-use thermostats
on the market today.
This thermostat has been designed to provide you with years of reliable
performance and comfort control.
Features
- Stylish new design with large display and bright blue backlight
- SpeedSet® programming gives you the option of programming all 7 days at once
- Convenient HOLD feature lets you override the program schedule
- Extra large display characters make viewing settings even easier
- User selectable filter monitor reminds you of required filter maintenance
- Precise temperature accuracy keeps you in control of your comfort
About Your Thermostat
Thermostat and Display
-
SYSTEM Switch ………………… Selects the system you want to control
PROG Button…………………….. Enters programming mode or hold for 3 seconds to enter SpeedSet® mode -
BACK Button* …………………… Secondary function of the PROG button – Moves to previous setting
-
HOLD Button …………………….. Enters / Exits the HOLD mode (program bypass mode)
NEXT Button* …………………… Secondary function of the HOLD button – Moves to next setting -
FAN Switch ………………………. Selects the system fan mode
-
Up / Down Arrow Buttons ….. Increases or decreases settings (time, temperature, etc.)
-
MENU Button ……………………. Used to access thermostat User setting mode or exit program mode
-
Room Temperature ………….. Displays the current room temperature
-
Set Temperature ……………… Displays the current setpoint temperature
-
Override Indicator …………… Indicates that the current program schedule has been temporarily overridden
-
Time of Day ……………………..Displays the current time of day
-
Program Event Indicator ….. Indicates which part of the program is currently active
-
System Mode ………………….. Displays the system mode and current system status
-
Fan Mode Indicator …………..Indicates the current system fan mode
-
Fan Status Indicator ………… Indicates that the system fan is running
-
Low Battery Indicator ………. Indicates when the batteries need to be replaced
Battery Compartment ……….. Located on the back side of thermostat (if installed)
BACK and NEXT are secondary functions of the PROG and HOLD buttons. When in programming or configuration modes, BACK and NEXT appear in the display screen indicating that the PROG and HOLD now function as BACK and NEXT.
User Settings
- User Settings allow you set the current time of day as well as customize various thermostat features.
- To access the User Settings, press and release the MENU button to display the first User Setting.
- Press the or buttons to change the value for the displayed User Setting. After your desired setting is displayed, press NEXT (HOLD) to advance to the next User Setting. You may also press BACK (PROG) to move backwards through the User Settings.
- You will exit the user settings after the last setting.
Table of User Settings
NOTE: Some user settings may not be available, depending on how the
thermostat was configured during installation.
No.| User Setting| Displayed| Default Setting|
Available Settings| Description of Available Settings
---|---|---|---|---|---
1| Reset SERVICE FILTER Message| CLR| N0| N0| Select to keep
message displayed
Y| Select to remove message and reset timer
[Only appears if the service filter time interval has expired] If a
service filter time interval was selected in setting 6, the thermostat will
display a SERVICE FILTER message once that time interval is reached. Select NO
to keep the message displayed or select Y (YES) to clear the message and reset
the timer.
2| Current Time of Day (Hour)| (current time)| 12:00| 1-12|
Select the current hour of day
Set the current hour of the day.
3| Current Time of Day (Minute)| (current time)| 12:00| 00-60|
Select the current minute of the hour
Set the current minute of the hour.
4| Current Day of the Week| (current day)| M| M-SU| Select the
current day of the week
Set the current day of the week.
No.| User Setting| Displayed| Default Setting|
Available Settings| Description of Available Settings
---|---|---|---|---|---
5| Service Filter Timer| SERVICE
FILTER
| OFF| OFF| Service filter timer is disabled
30, 60, 90,
120, 180, 365
| Select number of days for service filter timer
Select the number of days before receiving a reminder to change your system
filter (if equipped). When the timer interval has expired, the thermostat will
display the message SERVICE FILTER. To reset this reminder, see setting 1. To
disable, select OFF.
6| Temperature Hold Time (HOLD Button)| HOLD| LONG| LONG|
Select for long (permanent) HOLD mode
24HR| Select for 24 hour (temporary) HOLD mode
[Only available if programming is enabled] Temperature Hold Time lets
you select the time that your thermostat will hold the temperature when the
HOLD button has been pressed. When LONG is selected, the thermostat will hold
your temperature indefinitely. When 24HR is selected, the thermostat will hold
your temperature for 24 hours and then return to the current program
temperature.
7| Program Override Time Limit| OVERRIDE| 4 HR|
- 4HR, 3HR
- 2HR, 1HR
| Select a program override time limit of 1-4 hours.
[Only available if programming is enabled] The Program Override Time
Limit allows you to set a maximum time limit (in hours) that the thermostat
will return to the program after a temporary temperature override has been
made. You may select 1, 2, 3 or 4 hours.
8| User Reset| CLR| NO| NO| Reset disabled – no changes made
Y| Reset enabled – resets thermostat
Selecting (Y) YES will reset all user settings, program and current time.
Setting Your Program Schedule
Tips Before Setting Your Program Schedule
- Make sure your current time and day of the week are set correctly.
- Make sure the AM and PM indicators are correct.
- Your NITE event cannot exceed 11:50 p.m.
- BACK and NEXT are secondary functions of the PROG and HOLD buttons.
This thermostat has been configured with one of the following programming options
- 7-day programming mode with 4 events per day
- 5-2 (weekday/weekend) programming mode with 4 events per day
- Non-Programmable mode
NOTE : If this thermostat was configured to be non-programmable, then you cannot set a program schedule. If you press the PROG or HOLD buttons, the word “NONE” will appear in the display.
Energy Saving Programs
This thermostat comes pre-programmed with a default energy saving program. The
following tables outline the pre-programmed times and temperatures for heating
and cooling in each of your 4 daily events. If you wish to use these settings,
then no further programming is necessary:
Residential 7 Day Programming
Factory Settings
| 5-2 Day Programming Weekday/Weekend Factory Settings
---|---
4 Event| All Days| Weekday| Weekend
MORN| Time: 6:00 am Heat: 70˚ F (21˚ C) Cool: 78˚ F (26˚ C)| Time: 6:00 am
Heat: 70˚ F (21˚ C) Cool: 78˚ F (26˚ C)| Time: 6:00 am Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
DAY| Time: 8:00 am Heat: 62˚ F (17˚ C) Cool: 85˚ F (29˚ C)| Time: 8:00 am
Heat: 62˚ F (17˚ C) Cool: 85˚ F (29˚ C)| Time: 8:00 am Heat: 62˚ F (17˚ C)
Cool: 85˚ F (29˚ C)
EVE| Time: 6:00 pm Heat: 70˚ F (21˚ C) Cool: 78˚ F (26˚ C)| Time: 6:00 pm
Heat: 70˚ F (21˚ C) Cool: 78˚ F (26˚ C)| Time: 6:00 pm Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
NITE| Time: 10:00 pm Heat: 62˚ F (17˚ C) Cool: 82˚ F (28˚ C)| Time: 10:00 pm
Heat: 62˚ F (17˚ C) Cool: 82˚ F (28˚ C)| Time: 10:00 pm Heat: 62˚ F (17˚ C)
Cool: 82˚ F (28˚ C)
Setting a 7-Day program – All 7 Days at Once (SpeedSet®)
(7-day programming mode only)
NOTE: Setting all 7 days at once will copy over any previously programmed individual days.
Available Daily Events
MORN, DAY, EVE, NITE
- Hold the PROG button for 3 seconds until M-SU appears.
- Use SYSTEM switch to select HEAT or COOL. Press NEXT.
- Press or to adjust the hour for the first event. Press NEXT.
- Press or to adjust the minute for the first event. Press NEXT.
- Press or to adjust the temp for the first event. Press NEXT.
- Repeat steps 3-5 for the remaining daily events.
- If needed, repeat steps 2-6 to program the opposite mode.
- Press MENU to exit.
Setting a 7-Day program – Individual Days
(7-day programming mode only)
Available Daily Events
MORN, DAY, EVE, NITE
- Press and release the PROG button.
- Use SYSTEM switch to select HEAT or COOL.
- Press or to select the day you want to program. Press NEXT.
- Press or to adjust the hour for the first event. Press NEXT.
- Press or to adjust the minute for the first event. Press NEXT.
- Press or to adjust the temp for the first event. Press NEXT.
- Repeat steps 4-6 for your remaining daily events.
- If needed, repeat steps 3-7 to program additional days.
- If needed, repeat steps 2-8 to program the opposite mode.
- Press MENU to exit.
Setting a 5-2 Day Weekday/Weekend Program
(5-2 day programming mode only)
Available Daily Events
MORN, DAY, EVE, NITE
- Press and release the PROG button.
- Use SYSTEM switch to select HEAT or COOL.
- Press or to select weekdays or weekend. Press NEXT.
- Press or to adjust the hour for the first event. Press NEXT.
- Press or to adjust the minute for the first event. Press NEXT.
- Press or to adjust the temp for the first event. Press NEXT.
- Repeat steps 4-6 for your remaining daily events.
- If needed, repeat steps 3-7 to program additional days.
- If needed, repeat steps 2-8 to program the opposite mode.
- Press MENU to exit.
Operating Your Thermostat
Setting the SYSTEM Control Mode
The System Control has 4 modes of operation – COOL, OFF, HEAT, and EMER (2230
only). The mode can be selected by moving the SYSTEM switch to the appropriate
mode.
- COOL Only your cooling system will operate.
- OFF Heating and cooling systems are off.
- HEAT Only your heating system will operate
- EMER Operates a backup heat source (Emergency Heat) for heat pump systems only (2230 only).
Setting the FAN Control Mode
The Fan Control has 2 modes of operation – AUTO and ON. The mode can be
selected by moving the FAN switch to the appropriate mode.
- AUTO The system fan will run only when your heating or cooling system is running.
- ON The system fan stays on.
Temperature Adjustment
-
Temporary Adjustment (OVERRIDE) – Press or to adjust the current set temperature. The set temperature will change back to your programmed temperature a few hours later or at the start of the next scheduled program event. OVERRIDE will appear in the display during the entire override period.
-
Extended Adjustment (HOLD) – Press the HOLD button to override all programming. HOLD will appear in the display. You can continue to use the or buttons to adjust the current set temperature. Press HOLD again to resume the program schedule. You can limit your hold time to 24-hours by adjusting User Setting 6 in section 2.
NOTE: If your thermostat was configured to be non-programmable, HOLD and OVERRIDE are not available.
Program Event Indicators
Program event indicators appear in the display to let you know what part of
your current program is active.
MORN, DAY, EVE or NITE
When OVERRIDE appears, your program has been temporarily overridden and will
resume in 1-4 hours depending on the selection for User Setting 7 in section
2. The program will also resume at the beginning of the next scheduled program
event.
NOTE: If your thermostat was configured to be non-programmable, or is in HOLD mode, you will not see a Program Event or OVERRIDE indicator.
System Status and Maintenance Indicators
Status indicators are messages or symbols that appear in the display to let
you know what function your system is currently performing. They are also used
to inform you of various service and maintenance functions.
- HEAT ON The heating system is running.
- COOL ON The cooling system is running.
- HEAT ON AUX The auxiliary stage of heating is running (2230 only).
- EMERGENCY The emergency heating system is
- HEAT ON running (2230 only).
- Indicates that the system fan is running.
- SERVICE A user selectable filter service reminder for changing
- FILTER the filter has been triggered. To set or reset this reminder, see User Setting 5 in section 2.
- LIM Setpoint temperature has reached its upper or lower limit maximum.
- HI TEMP Room temperature has risen above the display range. Cooling will still operate to help lower temperature.
- LO TEMP Room temperature has fallen below the display range. Heat will still operate to help raise temperature.
- CHECK Indicates that there is a potential problem with your system. Contact a local service technician.
- If batteries are installed and they become low, the battery symbol appears in the display. When the batteries become critically low, the battery symbol will flash (see “Changing the Batteries” in section 6).
Additional Operating Features
Adaptive Recovery Mode (ARMTM)
If enabled, Adaptive Recovery Mode attempts to achieve your desired heating or
cooling temperature at the time you have set in your current program schedule,
after a setback period. For example, if you set your heat down to 62° at night
and have a set point of 70° scheduled for 7:00 AM, the thermostat may turn on
your heating system early in order achieve a temperature of 70° by 7:00 AM.
This feature does not operate when the thermostat is in HOLD mode; if the
program is temporarily overridden or if emergency heat is selected on a
multistage heat pump system.
Compressor Protection
This thermostat includes an automatic compressor protection delay to avoid
potential damage to your system from short cycling. This feature activates a
short delay after turning off the system compressor.
Thermostat Maintenance
Changing the Batteries
Depending on your installation, this thermostat may be equipped with two (2)
“AA” type alkaline batteries.
If batteries are installed and they become low, the battery symbol appears in
the display. When the batteries become critically low, the battery symbol will
flash.
To change your batteries
- Remove thermostat body by gently pulling it from base.
- Remove old batteries and replace with new batteries.
- Make sure to correctly position the (+) and (-) symbols.
- Gently push thermostat body back onto base.
NOTE : We recommend replacing the thermostat batteries annually or if the
thermostat will be unattended for
an extended period of time.
Thermostat Cleaning
Never spray any liquid directly on the thermostat. Spray your cleaning liquid
on a soft cloth and then proceed to clean the screen with the damp cloth. Only
use water or household glass cleaner. Never use any abrasive cleansers to
clean your thermostat.
For more information, visit www.braeburnonline.com
Limited Warranty
When installed by a professional contractor, this product is backed by a 5 year limited warranty. Limitations apply. For limitations, terms and conditions, you may obtain a full copy of this warranty.
- Visit us online: www.braeburnonline.com/warranty
- Phone us : 866.268.5599
- Or write us: Braeburn Systems LLC
- 2215 Cornell Avenue
- Montgomery, IL 60538
Braeburn Systems LLC
2215 Cornell Avenue
- Montgomery, IL 60538
- Technical Assistance : www.braeburnonline.com
- Call us toll- free: 866-268-5599 (U.S.)
- 630-844-1968 (Outside the U.S.)
- ©2023 Braeburn Systems LLC
- All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>