KEMLEN Super Nova RF Fireplace Insert Instruction Manual
- June 4, 2024
- KEMLEN
Table of Contents
KEMLEN Super Nova RF Fireplace Insert
DIMENSIONS
A | B | C | D* | E* | F | G | H | I | |
---|---|---|---|---|---|---|---|---|---|
STD | C / IRON | STD | C / IRON | ||||||
MEASUREMENT | 800 | 1000 | 650 | 434 | 470 | 330 | 377 | 660 | 661 |
TECHNICAL SPECIFICATIONS
PERFORMANCE:
- Average peak heat output – 11.6 kW
- Average Fuel consumption – 1.9 kg/hr.
- Average efficiency – 66%
- Weight – 128 kg.
*Average dry fuel (hardwood) consumption rate in kilogram/hour when heater is used normally and safely.
FIREBOX IS DESIGNED TO BE INSTALLED IN A MASONRY (BRICKWORK OR HEBEL BLOCK)
CAVITY
CAUTION – The gap between the top of the unit and the brick work should
be no more than 25mm. This will prevent the fascia being exposed to radiant
heat from the flue. Any gap larger than 25mm, should be shielded with non-
combustible material (Masonry, Metal and/or insulating material.) Fans must be
installed & operational at all times when a timber mantle is installed.
Minimum Hearth Requirements – Thickness to be a minimum of 9mm non combustible
material and must extend 300mm in front of firebox door and 300mm to each side
of the firebox door.
NOTICE TO ALL INSTALLERS:
DURING THE INSTALLATION OF THE FAN, MAKE SURE TO PULL THE FAN CORD OUT UNTIL THE CABLE TIE STOPS ON THE INSIDE OF THE CONDUIT. DO NOT AT ANY CIRCUMSTANCE PUSH THE CORD BACK THROUGH INTO THE BOX.
BAFFLE PLATE INSTALLATION
- MAKE SURE TO INSTALL AIR TUBE AS REQUIRED. THE OPENING ON THE TUBE END NEEDS TO BE AGAINST THE BACK WALL. ALL ROUND EXIT HOLES MUST BE POINTING TO THE BOTTOM OF THE FIRE BOX OR THE SIDE WALLS.
- CERAMIC BAFFLE PLATES SIZE 230mmX240mm. INSTALL THE BAFFLE PLATE 230mm FRONT TO BACK, 240mm SIDE TO SIDE. GET BAFFLE PLATE INSIDE THE FIREBOX AND TILT ON AN ANGLE. PUSH BAFFLE PLATE OVER THE AIR TUBE
- THEN MOVE SIDEWAYS UNTIL SUPPORTED BY THE SUPPORT PLATE AND TOUCHING THE SIDE WALL. MAKE SURE THE BAFFLE PLATE ALSO TOUCHES THE REAR WALL.
- REPEAT THE PROCESS FOR THE OTHER SIDE.
INSTALLATION INSTRUCTION
SUPER NOVA MASONRY/TIMBER CAVITY INSTALLATION
MANTLE DIMENSIONS
INSTALLATION INSTRUCTION
Improved heating efficiency is achieved by admitting cool air into the brick
cavity where it is heated by the outer skin of the firebox and active flues,
then released back into the room via hot air outlet vents.
NOTE: – Top of brick chimney can be left open, where no trees can cause a
build up of leaves etc. on top the weather plate. Weep holes must be left at
weather tray level as no smoke outlet holes will be needed in sides of
chimney.
ALTERNATIVE BRICK CHIMNEY TERMINATION:
2- off 350mm x 172mm chimney opening minimum size
NOTE: If chimney is more than 950mm wide then the two outlets only are
quite practical on the long side of chimney – width of outlet to be widened in
accordance with the length of the chimney.