REMINGTON REM-18PNCH-B Radiant Liquid Propane Cabinet Heater User Manual
- June 6, 2024
- Remington
Table of Contents
CABINET HEATER
User’s Manual & Operating Instructions
MODEL NUMBER
REM-18PNCH-B
CONSUMER: READ AND RETAIN THESE INSTRUCTIONS FOR FUTURE USE
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will be 8
digits. For Example: 12345678.
Have your Serial Number ready before calling customer service at
1-800-641-6996.
DANGER
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING
AND / OR ELECTRIC SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE
INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR
HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE
MANUFACTURER.
WARNING
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER
AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO
OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. KEEP
ALL COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUID
AWAY FROM THIS HEATER.
This heater is designed and approved for use as a construction heater in accordance with Standard for Gas fired Construction heaters ANS Z83.7 * CSA 2.14-2017. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these.
SAFETY INFORMATION
DANGER: Carbon Monoxide Hazard This heater produces carbon monoxide,
which has no odor. Burning the heater in an enclosed space can kill you. Never
use the heater in enclosed spaces such as a tent, a camper, any vehicle or
recreational vehicle (RV), enclosed shelter, or any other enclosed areas.
DANGER: If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of
life.
DANGER: Not for use in residential living areas or in non-adequately
ventilated enclosed spaces. Never bring or store a propane cylinder indoors.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.
WARNING: DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property loss or damage
from the hazards of fire, explosions, burns, asphyxiation or carbon monoxide
poisoning. Only persons who can read and understand these instructions should
use or service this heater.
WARNING: This is an unvented portable heater. It uses air (oxygen) from
the area in which it is used. Adequate combustion and ventilation air must be
provided. Refer to VENTILATION on Page 10.
WARNING: EXTREMELY HOT DURING OPERATION! Do Not touch any metal components
while in operation. Keep all combustible materials, gasoline, and other
flammable vapors and liquid away from this heater.
WARNING: WARNING: This product can expose you to chemicals, including
lead, which is known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
SAFETY INFORMATION (CONT.)
WARNING: RISK OF INDOOR AIR POLLUTION!
The products described in this manual are propane direct-fired, forced air
heaters. Propane forced air heaters are primarily intended for use for
temporary heating of buildings under construction, alteration or repair.
Direct-fired means that all of the combustion products of the heater enter the
heated space. This appliance is rated at 98% combustion efficiency, but does
produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation. Failure to provide proper ventilation in accordance with the instructions in this manual can result in death.
DANGER: CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
People with breathing problems should consult a physician before using this
heater. Early signs of carbon monoxide poisoning resemble the flu. Symptoms of
improper ventilation /carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms: GET FRESH AIR AT ONCE! Have your heater serviced and check for proper ventilation. Some people are more affected by carbon monoxide than others. These include: pregnant women, those with heart or lung problems, anemia or those under the influence of alcohol or at high altitudes.
FOR INDOOR USE ONLY: Adequate ventilation shall be provided in accordance with OSHA 29 CFR 1926.154, Safety Requirements for Temporary and Portable Space Heating Devices and Equipment, ANSI A10.10, ANSI Z223.1/NFPA 54 Liquefied Petroleum Gas Code, NFPA 58 or the Natural Gas and Propane Installation Code, CAN B149.1 as appropriate.
DANGER: PROPANE IS AN EXPLOSIVE GAS.
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
- DO NOT attempt to light the heater.
- Extinguish any open flame.
- Shut off gas to heater.
- If odor continues, contact your local gas supplier or fire department.
- DO NOT touch or use any electric switch or any electric device that can cause a spark.
- Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.
- If you can not reach your gas supplier, call the fire department.
- Service must be done by a qualified service agency.
WARNING: RISK OF BURNS, FIRE AND EXPLOSION!
- NEVER store or use gasoline or other flammable vapors and liquids in the vicinity of this heater.
- NEVER store a propane (LP) cylinder not connected to this heater in the vicinity of this heater.
- NEVER connect heater to an unregulated gas supply.
- NEVER obstruct the flow of combustion and ventilation air.
- NEVER use duct work in front or rear of heater.
- NEVER modify this heater or operate a heater that has been modified.
- NEVER service, move or handle heater while still hot or operating
- Keep all combustible materials, gasoline, and other flammable vapors and liquid away from this heater.
Minimum Clearance From Combustibles
Front| Sides| To p
40 in.| 16 in.| 40 in.
WARNING: AIR QUALITY HAZARD
WARNING: CAUTION! HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
-
Do not use this heater for heating human living quarters
-
Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO₂, and NO₂ considered to be hazardous to health and potentially life threatening
-
Do not use in unventilated areas
-
Know the signs of CO and CO₂ poisoning
• Headaches, stinging eyes
• Dizziness, disorientation
• Difficulty breathing, feels of being suffocated -
Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustions and maintain acceptable air quality shall be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1
-
Periodically monitor levels of CO, CO₂ and NO₂ existing at the construction site – at the minimum at the start of the shift and after 4 hours.
-
Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air quality
-
Ensure that the flow of combustion and ventilation air exchanges cannot become obstructed
-
As the building “tightens up” during the construction phase ventilation may need to be increased
USA 8-Hr Time weighted average (OSHA 29 CFR 1926.55 App A)
CO
CO₂
NO₂| 50 ppm
5000 ppm
USA – Ceiling Limit (Short Term Exposure Limit = 15 minutes)
CO
CO₂
NO₂| 5 ppm
Canada 8-hr time weighted average WorkSafe BC OHS Guidelines Part 5.1 and
Ontario Workplaces Reg 833
25 ppm
5000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
WARNING : For use with propane (LP) gas only.
- ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.
- Use heater in accordance with all local codes and with CSA 5.90 U.S. (5th Ed.) Infrared Patio Heater.
- This heater is shipped from the factory for use with propane (LP) gas only. Do not convert to any other gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1.
- Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame to check for gas leaks.
- Use only the regulator and hose assembly provided with this heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with the proper assembly shown in the parts list, prior to using the heater. The replacement hose assembly should follow manufacturer’s specification.
- This heater is not for use on finished floors.
Minimum and Maximum Inlet Pressure
Model| REM-18PNCH-B
Min.| 5 PSI
Max.| Bottle Pressure
WARNING: The hose assembly shall be pro tected from traffic, building
material, and contact with hot surfaces both during use and while in storage.
WARNING: RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL
SURFACE!
SPECIFICATIONS
Model # | REM-18PNCH-B |
---|---|
BTU | 6,000 / 12,000 / 18,000 |
Fuel Consumption (lb./hr) | 0.29 /0.57 / 0.86 |
Heat Settings | 3 |
Maximum Operating Hours | 69 / 35 / 23 |
Required Cylinder Lbs. | 20 |
Fuel Type | Use ONLY 20 lb. LP Gas Cylinder: 18″ x 12.25″ |
Heating Area (Ft.2) | 150 / 300 / 450 |
Specifications subject to change without notice.
WHAT’S IN THE BOX
FEATURES
UNPACKING
- Remove all packing items applied to heater for shipment. Keep plastic cover caps attached to inlet connector and hose/regulator assembly for storage.
- Remove all items from carton
- Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater.
CAUTION: The Propane (LP) gas pressure regulator and hose assembly supplied with the heater must be used without alteration.
ASSEMBLY
- Place heater on a flat surface.
- Fold propane tank tray down (see Figure 1)
- Attach Back Cover.
- Inspect heater closely for any damage that may have occured during shipping. If there is any damage, return the heater to place of purchase.
Connecting to Gas Supply
IMPORTANT! – Always use a propane (LP) cylinder that has a connection
device compatible with the hose and regulator assembly supplied.
- Remove the back cover by sliding the cover straight up and away from the heater body. Place the LP cylinder on the bottom plate and replace the back cover.
- To connect LP cylinder, insert regulator end fitting into cylinder valve, rotate coupling nut clockwise and tighten firmly (see Figure 2)
- Open valve on propane cylinder slowly. If the valve is not opened slowly, the excess flow check valve in the regulator will stop the flow of gas. If this should happen, close the valve, wait one minute (or until you hear the valve click), and re-open, slowly.
- Be sure to inspect all connections for leaks, by using a 50/50 mixture of dish soap and water on all connection. Any bubbles forming indicate a leak.
CAUTION
The Propane (LP) gas pressure regulator and hose assembly supplied with the
heater must be used without alteration.
CAUTION
Be sure to inspect the regulator hose before each use. If the hose is cut
or frayed, replace it with the manufacturer suggested assembly.
OPERATION
Propane Supply / Information: Propane (LP)
This heater is not supplied with a propane cylinder. Use only an approved
propane cylinder.
LP Characteristics
- Flammable, explosive under pressure, heavier than air, and pools in low areas.
- In its natural state, propane has no odor, but for your safety, an odor that smells like rotten cabbage has been added.
- Contact of propane (LP) gas with the skin can cause freeze burns.
- Heater is manufactured for use with propane gas only. DO NOT attempt to convert to any other gas. Such modifications are dangerous and will void the warranty.
- When the heater is not in use, LP Cylinder must be turned OFF. – Be sure that the LP Cylinder is located on a level and stable surface.
- DO NOT use this heater in a basement or below ground level. Propane is heavier than air and will always seek the lowest level. If you suspect a leak, shut off the valve at the LP Cylinder immediately.
The Propane (LP) cylinder must also be equipped with the following:
- A collar to protect the gas valve.
- A shut-off valve terminating a LP cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections.
- A safety relief valve having direct communications with the vapor space of the LP cylinder.
- The heater must operate on vapor withdrawal from the operating cylinder.
- Always keep LP cylinder fastened and upright.
CAUTION
Propane is safe to use when properly handled. Careless handling of the LP
cylinder could result in a fire and or an explosion.
- Avoid tipping the LP cylinder on its side when connected to a regulator, since this may cause damage to diaphragm in the regulator.
- Handle valves with care.
- Never connect an unregulated LP cylinder to a construction heater.
- DO NOT subject LP cylinder to excessive heat.
- Tightly close the gas shutoff valve on the LP cylinder after each use.
- All fittings must be protected when disconnected from the LP cylinder.
- Never store an LP cylinder inside a building or in the vicinity of an gas burning appliances.
CAUTION: The disconnected tank must never be stored in a building, garage, or any other enclosed area.
Pre-Lighting Instructions: Connecting the LP Cylinder
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
- Turn heater gas valve knob and LP cylinder valve to OFF position.
- LP cylinder valve equipped with old style fitting has LEFT HANDED THREADS. Turn fitting CLOCKWISE to loosen. Protect this fitting when disconnected from LP cylinder.
- Have your LP cylinder filled by your local propane gas supplier.
- Some LP cylinders have a bleed-OFF valve. This valve should be inspected for leaks after each filling of the LP cylinder. Turn the valve clockwise to close.
- Fasten full propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE.
- With heater gas valve knob still in OFF position turn ON the LP cylinder valve and check for leaks with soap solution.
WARNING
Purging and filling of the LP cylinders must be performed by personnel who
have been thoroughly trained in accepted LP gas industry procedures. Failure
to follow these instructions may result in explosion, fire, severe personal
injury or death.
OPERATION (CONT.)
Checking For Leaks
- To check for leaks, make up a 50/50 solution of dish soap and water. Apply this solution to all gas connections. If bubbles appear, there is a leak. If a leak is found, turn off the gas supply, and re-connect the leaking connection. If the leak persists after several tries, contact Pinnacle Customer Service at 800-641-6996.
- The installation of this heater must meet all local codes and/or gas utility requirements. In the absence of local codes, the National Fuel Code ANSI Z223.1 should be followed.
- The minimum clearances to any combustible construction materials must be maintained at all times (See Page 3).
- Inspect the heater before each use, and at least annually by a qualified service person.
WARNING: EXTREMELY HOT during operation. Do Not touch any metal components while in operation. Keep gasoline and any other flammable liquids away from the heater.
Lighting Instructions:
-
STOP! Read all of the safety information provided with this heater.
-
Turn valve on propane cylinder COUNTERCLOCKWISE until fully open.
-
Wait five (5) minutes for any gas to clear. Smell for gas. If none is evident, proceed to the next step.
-
Push in the valve knob and turn to “PILOT”.
NOTE: If this is first time use for heater or LP cylinder has been replaced, hold the valve knob for approximately 30 seconds to allow bleeding of air from system then turn valve knob to PILOT. -
While depressing the valve knob, press red piezo ignition button to ignite. It may be necessary to press the igniter button several times to ignite the center burner panel.
-
Continue to hold valve knob down for 30 seconds after the panel has lit. This will heat the thermocouple. After 30 seconds, release the valve knob.
-
If heater fails to light, or does not stay lit, repeat steps 2 through 6.
-
When the center burner panel stays lit, turn the valve knob to the desired setting.
Shut Down Instructions:
- Turn valve knob to the OFF position.
- Turn the knob at the LP cylinder CLOCKWISE to the OFF position.
- Disconnect regulator hose assembly from the LP cylinder.
Test Firing Heater:
It is always a good idea to test fire your heater in a safe and controlled
environment, in an area with adequate ventilation, and away from any
combustibles to be sure that all functions of the heater and gas supply system
are operating properly. Leak test all gas connections with a 50/50 solution of
dish soap and water. DO NOT use a flame to test for leaks!
Moving and Positioning the Heater:
There is a brake in each of the front wheels of your heater that helps keep it
in place when in use. To engage the brakes, push the lever down on each wheel.
To move the heater, release the brakes, simply by flipping the levers on both
brakes up. The gas must be turned off at the propane supply cylinders(s) when
the heater is not in use.
DANGER
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
VENTILATION
- Risk of indoor air pollution and Carbon Monoxide Poisoning. Use heater only in well ventilated areas.
- Refer to Safety Information on pages 2-3 for information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space of at least 3 square feet (2,800 sq. cm) for each 100,000 BTU / Hr. of heater output. Provide a larger opening if more heaters are being used.
-
FOR INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration, or repair.
Minimum Ventilation Opening NeededREM-18PNCH-B
0.54 ft.2
501.7 cm2
DANGER: CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
STORAGE / MAINTENANCE
Always disconnect the LP cylinder from the regulator assembly and remove the LP cylinder from the heater before putting the heater into storage. If for any reason, the heater is to be stored indoors, the heater MUST be disconnected from the LP cylinder, and the cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with the Standard for Storage and Handling of Liquefied Gasses, ANSI/NFPA 58 and Natural Gas and Propane Installation Code, CSA B149.1- latest edition. The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to protect the fitting from damage.
NOTE: Repair of this heater should be done by a qualified service person.
It is recommended that you save all of the packaging materials that came with
your heater, and re-package the heater using these materials for safe storage.
Debris, dust and dirt inside of the heater body can affect the performance of
your heater. This debris can impair the heater’s ability to draw air for
ventilation and combustion. Spiderwebs can also appear during periods of
inactivity.
Be sure to inspect the heater before each use to look for any such obstructions. Be sure to keep the air passage ways, burner, and combustion areas clean. Wipe with a damp cloth or use a vacuum cleaner to clean these areas. It is suggested that you perform a thorough cleaning at least once every 30 days of operation. You may need to clean the heater more often if conditions are naturally dirty. Clean the heater, including special surfaces, with recommended cleaning agents, if necessary.
Clean the ceramic plaques using compressed air below 30 PSI to prevent damage
to plaques.
A yellow tip of the pilot flame indicates that the burner area may be in need
of cleaning.
DANGER: Never store an LP cylinder inside of a building or near any other
gas or oil-burning appliances.
CAUTION: Always be sure that the heater has been allowed to cool for at least
30 minutes before attempting to store, service, or perform maintenance.
TROUBLESHOOTING GUIDE
Problem | Possible Cause | Solution |
---|---|---|
Burner fails to ignite | 1. Air in gas line |
2. Gas pressure from cylinder too low.
3. LP cylinder valve turned off
4. Obstruction in air passageway.
5. Dirt in pilot orifice.
6. Safety switch in cylinder valve engaged.
7. Tipover switch engaged.| 1. Keep depressing the gas control knob for at
least 30 seconds to remove any in line.
2. Check LP cylinder pressure. Tank may be empty.
3. Open LP cylinder valve.
4. Inspect and clean heater housing.
5. Blow out, or clean pilot orifice.
6. Close LP cylinder valve. Wait 1 min. for switch to click off. Reopen LP
cylinder valve slowly.
7. Move heater to a level surface.
No spark created when ignited| 1. Incorrect igniter electrode position.
2. Electrode damaged or broken.
3. Loose or disconnected igniter wire.
4. Broken igniter wire.| 1. Properly position electrode
2. Replace the electrode.
3. Tighten or reconnect loose wire.
4. Replace igniter wire.
Heater stops running by itself| 1. Thermocouple damaged
2. Gas control valve damaged.
3. Gas leak
4. Thermocouple not in contact with pilot flame.
5. Tip-over switch damaged, or loose connection at tipswitch.
6. Out of fuel.| 1. Replace entire heater
2. Replace gas control valve.
3. Check all connections for leaks using 50/50 solution of dish soap and
water. Repair any leaks found.
4. Clean inside of heater housing.
5. Inspect tip-over switch and connections. Replace if
necessary.
6. Replace LP cylinder
EXPLODED VIEW
PARTS LIST
Item # | Description | REM-18PNCH-B |
---|---|---|
1 | Piezo Button | 50-014-0100 |
LIMITED WARRANTY
Pinnacle Climate Technologies, Inc. warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.
Pinnacle Climate Technologies, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Climate Technologies , Inc. shall determine at its reasonable discretion.
This warranty does not apply to products purchased for rental use. This Limited Warranty does not cover any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.
All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, Pinnacle Climate Technologies, Inc. will examine the item and determine if defective. Pinnacle Climate Technologies, Inc. will repair or replace and return the item, freight pre-paid.
If Pinnacle Climate Technologies, Inc. finds the item to be in normal operating condition, or not defective the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. Pinnacle Climate Technologies, Inc. disclaims all warranties for products that are purchased from sellers other than authorized dealers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY EXPIRES, Pinnacle Climate Technologies, Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle Climate Technologies, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle Climate Technologies, Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.
Pinnacle Climate Technologies, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return or replacement of its equipment, and no such representations are binding on Pinnacle Climate Technologies, Inc.
Always be sure to specify the model number and serial number when making any claim with Pinnacle Climate Technologies, Inc. For your convenience, use the space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin
with the letters PGCV followed by 8 digits. For Example: PGCV12345678. Have
your Serial Number ready before calling customer service at
1-800-641-6996.
Model #:___
Serial #:____
Date of Purchase: ____
Sauk Rapids, MN 56379 USA • Toll Free
800-641-6996
Fax: 320-251-2922 • Web:
www.remingtonheater.com
• Email: info@pinnacleclimate.com
© 2021 Pinnacle Climate Technologies, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>