FRIGIDAIRE FG7S D,M Series Single Stage Condensing Gas Furnace Owner’s Manual

June 15, 2024
Frigidaire

FRIGIDAIRE FG7S D,M Series Single Stage Condensing Gas Furnace

Technical Specifications

  • Model: FG7S (D and M Series)
  • Type: High Efficiency, Single Stage Condensing, Upflow/Horizontal and Downflow Gas Furnace Models
  • AFUE: 95.0
  • Btuh Input: 38,000 – 120,000

Features and Benefits

  • The high efficiency upflow gas furnace can be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing appliance appearance. Design certified by CSA for application in Canada and the United States.

Gas Furnace Components
*UPFLOW / HORIZONTAL FURNACE (SD & SD-E SERIES)**

  • Flame Sensor
  • Finish Flange
  • Roll-Out Switch
  • Burner Assembly
  • Main Air Limit Switch
  • Inducer Limit Switch
  • Pressure Switch (Inducer)
  • Inducer Assembly
  • Blower Door Switch
  • Igniter
  • Gas Valve
  • Furnace Control Board
  • Pressure Switch (Condensate)
  • Transformer
  • Motor Choke
  • Motor Control Board
  • Blower Assembly

*DOWNFLOW FURNACE (SM SERIES)**

  • Blower Assembly (behind blower panel)
  • Finish Flange
  • Furnace Control Board
  • Blower Door Switch (behind blower panel)
  • Inducer Limit Switch
  • Gas Valve
  • Igniter
  • Transformer
  • Inducer Assembly
  • Pressure Switch
  • Flame Sensor
  • Burner Assembly
  • Roll-Out Switch
  • Gas Manifold

Dimensions
*SD Upflow / Horizontal Furnaces

Model # Dim. -A- Dim. -B- Dim. -C-
038D-24B 17 1/2 15 7/8 16 1/8
054D-24B 21 19 3/8 19 5/8
072D-35C 24 1/2 22 7/8 23 1/8
090D-35C 28 26 7/8 28 1/8
108D-45D 34 1/2 31 7/8 34 1/8
120D-45D 38 36 1/4 37 7/8

*SM Downflow Furnaces

Model # Dim. -A- Dim. -B- Dim. -C-
054D-24B 17 1/2 15 7/8 16 1/8
072D-35C 21 19 3/8 19 5/8
090D-35C 24 1/2 22 7/8 23 1/8
118D-45D 28 26 7/8 28 1/8

Blower Performance – FG7SD

Model Number & Heating Input (Btuh)| Motor Speed| External Static Pressure (Inches Water Column)| CFM Rise
---|---|---|---
SD038D-24B Bottom Return (38,000)| HIGH*| 0.1| 1519
SD038D-24B Side Return (38,000)| MED-H**| 0.2| 1483
SD054D-24B Bottom Return (54,000)| MED-L LOW| 0.3| 1433

FAQ

  1. Q: Where can I install the upflow gas furnace?
    A: The upflow gas furnace can be installed free standing in a utility room, basement, or enclosed in an alcove or closet.

  2. Q: What is the AFUE rating of the gas furnace?
    A: The AFUE rating of the gas furnace is 95.0.

  3. Q: Can the upflow/horizontal units be used for horizontal application?
    A: Yes, the upflow/horizontal units come ready for upflow or horizontal application.

  4. Q: Is the gas furnace certified for use in Canada and the United States?
    A: Yes, the gas furnace is design certified by CSA for application in Canada and the United States.

TECHNICAL SPECIFICATIONS

FG7S (D and M Series)

  • High Efficiency, Single Stage Condensing, Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000 – 120,000 Btuh Input The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application.
  • The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • 30 second blower delay at start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 second post purge increases life of heat exchanger.
  • Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
  • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Flexi ble category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
  • High Static Blowers: All models equipped with high static blowers.
  • Low Boy Height : Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
  • 60 second fixed cooling cycle blower-off delay (TDR) increases cooling performance when matched with a Nortek Global HVAC coil.
  • High efficiency blower kits maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
  • Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
  • LP convertible : Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Incorporates integrated control board with connections for electronic air cleaner and humidifier.
  • Two piece door design enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartme nt: Sealed door to reduce air leakage and insulated for ultra quiet operation.
  • Sealed Vestibule reduces burner and inducer sound levels.
  • Furnace Air Leakage : These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

*UPFLOW / HORIZONTAL FURNACE (SD & SD-E SERIES)**

*DOWNFLOW FURNACE (SM SERIES)**

DIMENTIONS

BLOWER PERFORMANCE – FG7SD

BLOWER PERFORMANCE – FG7SM

NOTES

  • Factory Set Cooling Speed
  • Factory Set Heating Speed
  1. Two openings are recommended for airflows above 1,600 CFM if filter(s) is(are) adjacent to furnace
  2. Temperature rises in the table are approximate. Actual temperature rises may vary.
  3. Temperature rises shaded in gray are for reference only. These conditions are not recommended

VENTING

  • All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.

VENT TABLE

NOTE

  1. Subtract 2.5 ft. for each additional 2″ elbow and 3.5 ft. for each additional 3″ elbow.
  2. Two 45 degree elbows are equivalent to one 90 degree elbow.
  3. One short radius elbow is equivalent to two long radius elbows.
  4. Do not include termination elbows in calculation of vent length.
  5. This table is applicable for elevations from sea level to 2000 ft. For higher elevations decrease vent pipe lengths by 8% per 1000 ft. of altitude. 6. Only the listed pipe materials are approved for use with FG7 Condensing Furnaces.

SPECIFICATIONS

Note: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency

  • Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

ACCESSORIES

GENERAL TERMS OF LIMITED WARRANTY

  • Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
  • For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
  • Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
  • Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2016) 749D-0816 (Replaces 749D-0512)
  • www.frigidairehvac.com
  • FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc.
  • © Nortek Global HVAC, LLC. All Rights Reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Frigidaire User Manuals

Related Manuals