FRIGIDAIRE FG7S D,M Series Single Stage Condensing Gas Furnace
Technical Specifications
- Model: FG7S (D and M Series)
- Type: High Efficiency, Single Stage Condensing, Upflow/Horizontal and Downflow Gas Furnace Models
- AFUE: 95.0
- Btuh Input: 38,000 – 120,000
Features and Benefits
- The high efficiency upflow gas furnace can be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing appliance appearance. Design certified by CSA for application in Canada and the United States.
Gas Furnace Components
*UPFLOW / HORIZONTAL FURNACE (SD & SD-E SERIES)**
- Flame Sensor
- Finish Flange
- Roll-Out Switch
- Burner Assembly
- Main Air Limit Switch
- Inducer Limit Switch
- Pressure Switch (Inducer)
- Inducer Assembly
- Blower Door Switch
- Igniter
- Gas Valve
- Furnace Control Board
- Pressure Switch (Condensate)
- Transformer
- Motor Choke
- Motor Control Board
- Blower Assembly
*DOWNFLOW FURNACE (SM SERIES)**
- Blower Assembly (behind blower panel)
- Finish Flange
- Furnace Control Board
- Blower Door Switch (behind blower panel)
- Inducer Limit Switch
- Gas Valve
- Igniter
- Transformer
- Inducer Assembly
- Pressure Switch
- Flame Sensor
- Burner Assembly
- Roll-Out Switch
- Gas Manifold
Dimensions
*SD Upflow / Horizontal Furnaces
Model # | Dim. -A- | Dim. -B- | Dim. -C- |
---|---|---|---|
038D-24B | 17 1/2 | 15 7/8 | 16 1/8 |
054D-24B | 21 | 19 3/8 | 19 5/8 |
072D-35C | 24 1/2 | 22 7/8 | 23 1/8 |
090D-35C | 28 | 26 7/8 | 28 1/8 |
108D-45D | 34 1/2 | 31 7/8 | 34 1/8 |
120D-45D | 38 | 36 1/4 | 37 7/8 |
*SM Downflow Furnaces
Model # | Dim. -A- | Dim. -B- | Dim. -C- |
---|---|---|---|
054D-24B | 17 1/2 | 15 7/8 | 16 1/8 |
072D-35C | 21 | 19 3/8 | 19 5/8 |
090D-35C | 24 1/2 | 22 7/8 | 23 1/8 |
118D-45D | 28 | 26 7/8 | 28 1/8 |
Blower Performance – FG7SD
Model Number & Heating Input (Btuh)| Motor Speed| External Static Pressure
(Inches Water Column)| CFM Rise
---|---|---|---
SD038D-24B Bottom Return (38,000)| HIGH*| 0.1| 1519
SD038D-24B Side Return (38,000)| MED-H**| 0.2| 1483
SD054D-24B Bottom Return (54,000)| MED-L LOW| 0.3| 1433
FAQ
-
Q: Where can I install the upflow gas furnace?
A: The upflow gas furnace can be installed free standing in a utility room, basement, or enclosed in an alcove or closet. -
Q: What is the AFUE rating of the gas furnace?
A: The AFUE rating of the gas furnace is 95.0. -
Q: Can the upflow/horizontal units be used for horizontal application?
A: Yes, the upflow/horizontal units come ready for upflow or horizontal application. -
Q: Is the gas furnace certified for use in Canada and the United States?
A: Yes, the gas furnace is design certified by CSA for application in Canada and the United States.
TECHNICAL SPECIFICATIONS
FG7S (D and M Series)
- High Efficiency, Single Stage Condensing, Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000 – 120,000 Btuh Input The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal units come ready for upflow or horizontal application.
- The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- 30 second blower delay at start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Flexi ble category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
- High Static Blowers: All models equipped with high static blowers.
- Low Boy Height : Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
- 60 second fixed cooling cycle blower-off delay (TDR) increases cooling performance when matched with a Nortek Global HVAC coil.
- High efficiency blower kits maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
- LP convertible : Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
- Incorporates integrated control board with connections for electronic air cleaner and humidifier.
- Two piece door design enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartme nt: Sealed door to reduce air leakage and insulated for ultra quiet operation.
- Sealed Vestibule reduces burner and inducer sound levels.
- Furnace Air Leakage : These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
GAS FURNACE COMPONENTS
*UPFLOW / HORIZONTAL FURNACE (SD & SD-E SERIES)**
*DOWNFLOW FURNACE (SM SERIES)**
DIMENTIONS
BLOWER PERFORMANCE – FG7SD
BLOWER PERFORMANCE – FG7SM
NOTES
- Factory Set Cooling Speed
- Factory Set Heating Speed
- Two openings are recommended for airflows above 1,600 CFM if filter(s) is(are) adjacent to furnace
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are for reference only. These conditions are not recommended
VENTING
- All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.
VENT TABLE
NOTE
- Subtract 2.5 ft. for each additional 2″ elbow and 3.5 ft. for each additional 3″ elbow.
- Two 45 degree elbows are equivalent to one 90 degree elbow.
- One short radius elbow is equivalent to two long radius elbows.
- Do not include termination elbows in calculation of vent length.
- This table is applicable for elevations from sea level to 2000 ft. For higher elevations decrease vent pipe lengths by 8% per 1000 ft. of altitude. 6. Only the listed pipe materials are approved for use with FG7 Condensing Furnaces.
SPECIFICATIONS
Note: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency
- Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
ACCESSORIES
GENERAL TERMS OF LIMITED WARRANTY
- Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
- For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
- Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
- Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2016) 749D-0816 (Replaces 749D-0512)
- www.frigidairehvac.com
- FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc.
- © Nortek Global HVAC, LLC. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>