FEIT Electric 74206 Dimmable White Round Flat Panel Ceiling Light User Guide

June 15, 2024
Feit Electric

FEIT Electric 74206 Dimmable White Round Flat Panel Ceiling Light

Safety Information

For your safety, always remember to:

  • Turn off the power supply at the fuse or circuit breaker box before you install the fixture.
  • Ground the fixture to avoid potential electric shock and to ensure reliable starting.
  • Double-check all connections to be sure they are tight and correct.
  • Wear rubber soled shoes and work on a sturdy wooden ladder.
  • Account for small parts and destroy packing material, as these may be hazardous to children.
    This fixture is designed for use in a circuit protected by a fuse or circuit breaker. It is also designed to be installed in accordance with local electrical codes. If you are unsure about your wiring, consult a certified electrician or local electrical inspector, and check your local electrical code.

FCC STATEMENT

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Feit Electric Company, 4901 Gregg Road, Pico Rivera, CA 90660. www.feit.com. CAN ICES-005 (B).

WARNING: RISK OF ELECTRIC SHOCK. House electric current can cause painful shock or serious injury unless handled properly.
CAUTION: Turn off the main power at the circuit breaker before installing the fixture, in order to prevent possible shock.
WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

NOTICE: All electrical connections must be in accordance with local and National Electrical Code (N.E.C.) standards. If you are unfamiliar with proper electrical wiring connections obtain the services of a certified electrician.
Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS

WARNING: Risk of fire. Use only on 120 volt 60Hz circuits. Suitable for damp locations. Before installing your lighting fixture, thoroughly review enclosed installation manual. If you do not have sufficient electrical wiring experience, please refer to a do-it-yourself wiring handbook or have your fixture installed by a certified electrician. All electrical connections must be in accordance with Local and National Electrical Code (NEC) Standards. Reliable operating temperature is 0˚F –120˚F. If flickering occurs in low level dimming, increase light level. Compatible with most dimmers including Leviton 6681-IW, Lutron S-600P and Lutron DVCL-153. Dimmable to 10% with most dimmers.

THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION

Supplier’s Declaration of Conformity: 47 CFR § 2.1077 Compliance Information
Responsible Party: Feit Electric Company 4901 Gregg Road, Pico Rivera, CA 90660, USA 562-463-2852
Unique Identifier: 74206/6WYCA

Limited Warranty

This product is warrantied to be free from defects in workmanship and materials for up to 5 years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact- us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province. which vary from state to state or province to province.

Pre-Installation

TOOLS REQUIRED

  • Phillips Screwdriver

HARDWARE INCLUDED

NOTE: Hardware not shown to actual size.
HARDWARE INCLUDED

Part Description Quantity
AA 7.5 in. Fixture 1
BB Mounting Bracket 1
CC 5 & 6 in. Torsion Spring Brackets 2
DD E26 Adapter with Male Connector 1
EE Stripped Wires with Male Connector 1
FF 5 & 6 in. Torsion Springs 2
GG Ground Wire 1
HH Ground Wire Screw 1
II J-Box Mounting Screws 2
JJ Wire Connectors 3
KK 5 & 6 in. Torsion Spring Screws 2
LL 5 & 6 in. Torsion Bracket Mounting Screws 4

Junction Box Installation

  1. Turning Off the Power

    • Turn the power OFF at the switch and fuse box or the circuit breaker.
  2. Choosing a Color Temperature
    Use the slide switch to choose a color temperature before installing. The choices are Soft White, Neutral White, Bright White, Daylight and Daylight Deluxe. You can also choose to adjust the color temperature from the wall switch.

  3. Connecting the Wires

    • Identify the wiring: (Black – line voltage, White – neutral and Green – ground)
    • Connect the stripped wires with male connector (EE) to the two wires coming from the J-box: Black – line voltage to Black, White – neutral to White, using wire connectors provided (JJ).
    • Ensure the fixture (AA) is properly grounded according to local code requirements. Connect the ground wire (FF) to the mounting bracket (BB) and connect to the ground wire in the J-box with the wire connectors provided (JJ).
  4. Installing the Mounting Bracket to the Junction Box

    • Install the mounting bracket (BB) to the J-box by inserting the two mounting screws (II) through the slots in the mounting bracket (BB).
    • Make sure the mounting bracket (BB) is installed with the label facing downwards.
  5. Installing the Fixture to the Mounting Bracket

    • Secure the fixture (AA) to the mounting bracket (BB) by pressing the fixture (AA) into the mounting bracket (BB) until the clips on the fixture (AA) engage together. Make sure the fixture (AA) is firmly locked into place.

5/6 In. Recessed Can Installation

  1. Turning Off the Power

    • Turn the power OFF at the switch and fuse box or the circuit breaker.
    • Remove the existing trim installed in the recessed housing.
  2. Choosing a Color Temperature
    Use the slide switch to choose a color temperature before installing. The choices are Soft White, Neutral White, Bright White, Daylight and Daylight Deluxe. You can also choose to adjust the color temperature from the wall switch.

  3. Remove the Mounting Bracket

    • Remove the mounting bracket (BB) from the fixture (AA).
  4. Installing the 5/6 in. Clip Springs ،to the Mounting Bracket

    • Install the 5/6 in. torsion brackets (CC) to the mounting bracket (BB) using four torsion bracket screws (LL).
  5. Adjusting the Torsion Springs

    • Insert the torsion springs (FF) into mounting bracket (BB).
    • The position of the torsion springs (FF) will vary depending on the diameter of the recessed housing.
      5/6 In. Recessed Can Installation
  6. Installing the Adapter and Connecting the Terminals
    Install the E26 adapter (DD) into the socket.

    • Connect the two terminals together.
      5/6 In. Recessed Can Installation
  7. Installing the fixture into the recessed housing

    • Install torsion spring (FF) into fixture bracket.
    • Gently push the fixture (AA) into the recessed housing

Changing the Color Settings

Changing the Color Settings

  1. When the slide switch is set to 3000K, the color temperature is set to Warm White.

  2. When the slide switch is set to 3500K, the color temperature is set to Neutral White.

  3. When the slide switch is set to 4000K, the color temperature is set to Cool White.

  4. When the slide switch is set to 5000K, the color temperature is set to Daylight.

  5. When the slide switch is set to 6500K, the color temperature is set to Daylight Deluxe.

  6. When the slide switch is set to SWITCH, the color temperature can be changed from 3000K, 3500K, 4000K, 5000K and 6500K with your existing light switch.

  7. To change color temperatures using your existing light switch:
    A. Set the slide switch on the back of the fixture to SWITCH.
    B. Toggle your light switch ON and OFF within 0.5-3 seconds to cycle though the 5 different color temperatures.
    C. If the fixture is left OFF for over 10 seconds then turned ON, the fixture will remember the last color temperature selected and will display that color when turned on again.

  8. Reset function is used when operating multiple color selectable lighting products from the same light switch. In the event multiple fixtures are not displaying the same color at the same time, the fixtures must be reset using your existing light switch. Toggle the wall switch ON and OFF seven times (leave the switch in the ON position for five seconds before toggling to OFF).

LIGHTING DISTRIBUTION

DISTANCE| CENTER BEAM (FOOT CANDLES)| BEAM DIAMETER
3 FT.| 38| 8.3 FT.
5 FT.| 14| 14 FT.
8 FT.| 5.4| 22 FT.
15 FT.| 1.5| 41 FT.
BEAM ANGLE = 108º| BEAM CD @ CB: 343

Customer Support

Questions, problems, missing parts?
**Before returning to store, visitfeit.com/help for further assistance.

FEIT ELECTRIC COMPANY | PICO RIVERA, CA | www.feit.com**

WWW.FEIT.COM
Retain this manual for future use.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Feit Electric User Manuals

Related Manuals