LIEBHERR SIGN 3576 Premium NoFrost Freezer Owner’s Manual
- June 15, 2024
- LIEBHERR
Table of Contents
LIEBHERR SIGN 3576 Premium NoFrost Freezer
Product Information
Specifications
- Integrated Ventilation
- Venting Options: Above Cupboard, Into Ceiling Space*, At Top of Unit
- Dimensions:
- Width: 560-570 mm
- Height: 1772-1788 mm
- Depth: 40 mm
- Venting Requirements :
- Minimum Ventilation Area: 500 cm2
- Minimum Distance from Cupboard: 200 cm2
Product Usage Instructions
Venting Above Cupboard
To vent the product above the cupboard, follow these steps:
- Ensure there is sufficient space above the cupboard to accommodate the product’s dimensions.
- Position the product on top of the cupboard, aligning it with the ventilation opening.
- Secure the product in place using appropriate mounting brackets or screws.
Venting Into Ceiling Space
To vent the product into the ceiling space, follow these steps:
- Locate a suitable ventilation opening in the ceiling.
- Position the product below the ventilation opening.
- Connect the product’s venting system to the ceiling opening using appropriate ducting or piping.
- Ensure a secure and airtight connection between the product and the ceiling opening.
Venting at the Top of the Unit
To vent the product at the top of the unit, follow these steps:
- Identify the designated venting area at the top of the product.
- Remove any covers or obstacles blocking access to the venting area.
- Connect the product’s venting system to the designated area using appropriate ducting or piping.
- Ensure a secure and airtight connection between the product and the venting area.
Frequently Asked Questions (FAQ)
Q: What is the minimum ventilation area required for this product?
A: The minimum ventilation area requirement for this product is 500 cm2.
Q: What is the minimum distance from the cupboard that needs to be
maintained for proper venting?
A: A minimum distance of 200 cm2 should be maintained between the cupboard
and the product for proper venting.
Q: Can I vent this product into a wall instead of the ceiling space?
A: No, this product is designed to be vented either above a cupboard, into
the ceiling space, or at the top of the unit. Venting into a wall is not
recommended.
Q: How can I secure the product in place above the cupboard?
A: You can use appropriate mounting brackets or screws to securely attach
the product to the top of the cupboard.
Q: Are there any specific maintenance requirements for the venting system?
A: Regularly check and clean the venting system to ensure proper airflow
and prevent blockages. Refer to the maintenance section of the user manual for
detailed instructions.
VENTING ABOVE CUPBOARD
VENTING INTO CEILING SPACE
VENTING AT TOP OF UNIT
Figures 1, 2, and 3 represent the alternate ways that Liebherr integrated appliances can be installed to ensure correct ventilation requirements are achieved. Arrows denote airflow from the ventilation entry to the exit point. The ventilation options apply to the following models: SIGN 3576, SIKB 3550, EWTdf 3553, EWTgb 3583, ICNh 5123, ICNh 5133, ICNh 5173, ICBNh 5173 and Project Only Models SIKB 3520, SIGN 3524. ICNh 5103, IRBh 5120 & SIFNh 5128. *Ceiling spaces and bulkheads must be well-ventilated.
- HEAD OFFICE: 1 Stamford Road Oakleigh Vic 3166, T: 1800 685 899, E: sales@andico.com.au, W: www.andico.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>