NEXSENS CM-HYD Sea Bird Scientific HydroCAT CTD Sensor Installation Guide

June 15, 2024
NEXSENS

NEXSENS CM-HYD Sea Bird Scientific HydroCAT CTD Sensor Installation Guide
NEXSENS CM-HYD Sea Bird Scientific HydroCAT CTD Sensor

Overview

Product Overview

The CM-HYD HydroCAT sensor mount allows the Sea-Bird Scientific HydroCAT CTD sensor to be securely attached to the instrument cage of a CB-Series data buoy system.

  • What’s Included
  • (1) Cage mount bracket
  • (2) 332 Silicon O-rings
  • (4) Sensor mount brackets
  • (4) 3/8-16 x 6-1/2″ Hex head cap screws
  • (4) 3/8-16 x 2″ Hex head cap screws
  • (8) 3/8-16 Nylon nuts
  • (16) 3/8″ Flat washers

Installation on Buoy Instrument Cage

  1. Insert the 6-1/2″ hex head cap screws with a flat washer through the cage mount bracket and the bottom of the sensor mount brackets.
    Installation Instruction
    Figure 2: Install the bottom sensor mount brackets

  2. Place the (2) 332 Silicon O-rings onto the HydroCAT CTD sensor.
    a. Ensure to align the O-rings with the grooves in the bottom sensor mount brackets.
    Installation Instruction
    Figure 3: Space the O-rings out to align with the brackets

  3. Install the top sensor mount brackets onto the other side of the 6-1/2″ hex head cap screws with a flat and lock washer.
    a. Tighten using a 9/16″ socket or hex driver.
    b. Point the steel frame outwards as shown in the image.
    Installation Instruction
    Figure 3: Install the top sensor mount brackets

  4. Use the available holes and the 3/8-16 x 2″ Hex head cap screws, lock and flat washers, and nylon nuts to secure the mount to the cage.
    a. Tighten using a 9/16″ socket or hex driver.
    Installation Instruction
    Figure 4: Secure the mount to the cage

NEXSENS Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals