SANTEC 9950CU Roman Tubs Instruction Manual

June 15, 2024
SANTEC

SANTEC 9950CU Roman Tubs

Product Information

Specifications

  • Product Type: Roman Tubs
  • Compatible Collections: AVA
  • Minimum Hole Size for Spout and Handle Trim: 1-1/4″
  • Maximum Hole Size for Spout and Handle Trim: 1-1/2″
  • Maximum Deck Thickness: 1″

Product Usage Instructions

Spout Installation

  1. Flush both supply lines before installation. After flushing, shut off both supply lines.
  2. Remove the tee connector and spout mounting hardware from the quick connect shank, leaving the brass plate on.
  3. Apply a ring of silicone caulking around the designated hole for the spout. Do not use plumber’s putty as it can damage the finish.
  4. From the top of the deck, slip the quick-connect shank through the assigned spout hole.
  5. Secure the quick connect shank by putting the washer and lock nut back on the shank. Tighten the lock nut firmly.
  6. From the top of the deck, slip the spout with the flange and flange washer onto the quick-connect shank top. Align the spout and tighten the set screw with the provided Allen key.
  7. Connect the tee connector to the spout shank.

Handle Trim Installation

  1. Unscrew the pre-assembled handle trim from the valve body. The hot valve assembly (red) should be mounted on the left, and the cold valve assembly (blue) should be mounted on the right.
  2. Remove the top lock nut and fiber gasket from the valve body.
  3. Apply a ring of silicone caulking around the handle hole on the deck top. Do not use plumber’s putty as it can damage the finish.
  4. Slip the valve body up from below the tub deck.
  5. Place the top lock nut and fiber gasket back onto the valve body until the top surface of the lock nut is flush with the top surface of the valve body.
  6. Secure the top lock nut in place before inserting the handle.
  7. Align the handles concerning the spout and tighten the bottom lock nut until secure.

Water Test
To ensure a proper installation, follow these steps:

  1. Turn on the cold water supply.
  2. Use the handle from the faucet set to turn the valve on and off.
  3. Check for leaks. If water leaks from any of the connections, tighten them until the leak stops.
  4. Repeat the same procedure for the hot water supply.

FAQ

  • Q: What size hole is required for the spout and handle trim?
    A: The minimum hole size is 1-1/4″ and the maximum hole size is 1-1/2″.

  • Q: What is the maximum deck thickness for installation?
    A: The maximum deck thickness is 1″. Depending on the deck thickness, it may be necessary to countersink from below.

  • Q: What should I use to seal the holes during installation?
    A: It is recommended to use silicone caulking. Do not use plumber’s putty as it can damage the finish.

  • Q: How should I secure the handles?
    A: Align the handles concerning the spout and tighten the bottom lock nut until secure.

  • Q: How do I perform a water test?
    A: Turn on the cold water supply and use the handle from the faucet set to turn the valve on and off. Check for leaks and tighten any connections if necessary. Repeat the same procedure for the hot water supply.

PLEASE READ THE INSTRUCTIONS COMPLETELY BEFORE BEGINNING THE INSTALLATION.

Overview

SANTEC-9950CU-Roman-Tubs-fig- \(1\)

INSTALLATION INSTRUCTIONS

S POUT INSTALLATION
  • FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION. AFTER FLUSHING, SHUT OFF BOTH SUPPLY LINES.
  • MINIMUM HOLE SIZE FOR THE SPOUT AND HANDLE TRIM IS 1-1/4” AND THE MAXIMUM IS 1 -1/2”
  1. Remove the tee connector and spout mounting hardware from quick connect shank being sure to leave it on a brass plate.
  2. Apply a ring of silicone caulking around the hole designated for the spout. DO NOT USE PLUMBERS’ PUTTY, WHICH CAN DAMAGE FINISH.
  3. From the top of the deck, slip the quick-connect shank through the assigned spout hole.
  4. Secure the quick connect shank by putting the washer and lock nut back on the shank. Tighten the lock nut firmly.
  5. From the top of the deck, slip the spout with the flange and flange washer onto the quick-connect shank top. Align the spout and tighten the set screw with the Allen key provided.
  6. Connect the tee connector to the spout shank.
HANDLE T-RIM INSTALLATION

MAXIMUM DECK THICKNESS 1”. DEPENDING ON DECK THICKNESS, IT MAY BE NECESSARY TO COUNTERSINK FROM BELOW.

Step 1
Unscrew the pre-assembled handle trim from the valve body. Hot valve assembly “Red” to be mounted on the left. Cold valve assembly “Blue” is to be mounted on the right.

Step 2

  1. Remove the top lock nut and the fiber gasket from the valve body.
  2. Apply a ring of silicone caulking around the handle hole on the deck top.

DO NOT USE PLUMBERS’ PUTTY, WHICH CAN DAMAGE FINISH.

Step 3

  1. Slip valve body up from below tub deck.
  2. Place the top lock nut and the fiber gasket back onto the valve body until the top surface of the lock nut is flush with the top surface of the valve body.
  3. Secure the top lock nut in place before inserting the handle.

Step 4
Align handles for the spout and tighten the bottom lock nut until secure.

WATER TEST

  • Turn on the cold water supply.
  • Use the handle from the faucet set to turn the valve on and off.
  • Check for leaks. If water leaks from any of the connections merely tighten the connections until the leak stops.
  • Repeat the same procedure for the hot water supply.

SANTEC RECOMMENDS:

  • The use of Teflon tape or equivalent on all threaded joints.
  • The installation of hard plumbing, not flex connections for all connections.
  • An access panel is provided for all Roman tub installations.

SANTEC-9950CU-Roman-Tubs-fig- \(9\)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals