Q-TRAN Q-VAULT Direct Burial Transformer Installation Guide

June 15, 2024
Q-TRAN

Q-VAULT Direct Burial Transformer

Product Information

Specifications

  • Model Numbers:
    • Q-SET+QZ-30
    • Q-SET+QZ-60
    • Q-SET+QZ-96
    • Q-SET+QZ-DW-96
    • Q-SET+QZ-DMX-96
    • Q-SET+QZ-DALI-96
  • Output Class: CLASS 2
  • Max Lamp Load:
    • Q-SET+QZ-30: 30W
    • Q-SET+QZ-60: 60W
    • Q-SET+QZ-96: 96W
    • Q-SET+QZ-DW-96: 96W
    • Q-SET+QZ-DMX-96: 96W
    • Q-SET+QZ-DALI-96: 96W
  • Primary Volts: 120V/277 (60Hz)
  • Lamp Volts: 24VDC
  • Dimmer Rating: 0-10/ELV/MLV

Product Usage Instructions

Installation

To install the Q-VAULT – Q-SET+QZ-DALI, follow these steps:

  1. Ensure you are following all applicable local codes and
    regulations.

  2. Choose the appropriate model number based on your
    requirements.

  3. Connect the Q-SET LOW VOLTAGE LUMINAIRE POWER SUPPLY to your
    power source.

  4. Make sure the output class matches your requirements.

  5. Take note of the maximum lamp load for your model.

  6. Connect the lamp to the Q-SET+QZ-DALI using the specified lamp
    volts.

  7. If using a dimmer, ensure it is compatible with the dimmer
    rating provided.

  8. Follow the specific installation instructions for outdoor or
    indoor use, depending on your application.

Outdoor Installation

For outdoor installations, refer to the following
guidelines:

CSA Listing

Under 30 Volts = LV Wire Buried 0 to 6:

  • CSA Certified for both the U.S. and Canada to the UL-1838
    Standard for Landscape Lighting with in-ground enclosure and
    component power supply operating at less than 30VDC.

  • The LV Q-WIRE can be installed underground up to 6 feet.

Pool & Spa – Under 30 Volts:

  • CSA Certified for the U.S. to the UL-379 Pool & Spa Power
    Supply Standard.

  • Intended for power supplies used to power fountain, swimming
    pool, and spa luminaires operating at less than 30V.

15 to 30 Volts = LV Wire Buried 18:

  • CSA Certified for both the U.S. and Canada to UL-2108 Standard
    with a listing of Low Voltage Luminaire Power Supply for lamps
    operating at 12 or 24 volts where the secondary voltage is between
    15 to 30 volts.

  • The secondary wiring must be installed 18 inches below grade
    per the N.E.C.

Indoor Installation

For indoor installations, follow these guidelines:

LV Lighting under 30 Volts:

  • CSA Certified for both the U.S. and Canada to UL-2108 Standard
    as a Low Voltage Luminaire Power Supply for lamps operating at 12V
    or 24V.

  • Allows for live conductor lighting equipment mounted above 7
    feet and other types of LV Lighting equipment, per N.E.C. Article

Note: It is important to refer to the last page of the user
manual for additional information.

Warnings

Pay attention to the following warnings during installation:

  • Conduit Connection Warning (for Q-VAULT
    120/277V):
    Install the power unit at least 5 feet (1.5m)
    away from the pool or spa and 10 feet (3.05m) away from a fountain.
    If the power unit is installed within 10 feet (3.05m) of a pool or
    spa, connect it to a GFCI protected branch circuit.

  • Power Supply Cord Connection Warning: Install
    the power unit at least 5 feet (1.5m) away from the pool, spa, or
    fountain. If the power unit is installed indoors within 10 feet
    (3.05m) of a pool, spa, or fountain, or outdoors, connect it to a
    receptacle protected by a GFCI.

  • Fire Risk Warning: If the installation
    requires running wire through a building structure, special wiring
    methods are needed. Contact a qualified electrician.

  • Outdoor Cord-connected Unit Warning: The unit
    should be connected to a GFCI protected hooded flush type cover
    plate receptacle marked Wet Location.

FAQ

Q: Can the Q-SET+QZ-DALI be used for outdoor landscape

lighting?

A: Yes, the Q-SET+QZ-DALI is CSA Certified for outdoor landscape
lighting applications.

Q: What is the maximum lamp load for the Q-SET+QZ-60

model?

A: The Q-SET+QZ-60 has a maximum lamp load of 60W.

Q: Can I use a dimmer with the Q-SET+QZ-DALI?

A: Yes, the Q-SET+QZ-DALI is compatible with dimmers that have a
0-10/ELV/MLV rating.

Q: Are there any special requirements for indoor

installations?

A: For indoor installations, ensure that the LV Lighting
equipment is mounted above 7 feet and follow N.E.C. Article 411
guidelines.

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

CANADA

· 3426-94 Luminaires – Landscape Lighting Systems – Certified to UL – 1838 Standard. · 3425-95 Luminaires – Low Voltage Lighting Systems – Certified to UL – 2108 Standard. · 3425-96 Luminaires – Component Hydromassage – Certified to UL – 379 Pool & Spa Standard.
· 3426-04 Luminaires – Landscape Lighting Systems – Component (including Hydromassage). · 3425-15 Luminaires – Low Voltage Lighting Systems.

· For supply connections use wire rated for at least 90°C · Suitable for in- ground installation. · Not for installation to conduit extending directly to an underwater pool light forming shell. In line Pool and Spa rated junction box required. · Suitable for use with submersible luminaries · Suitable for direct burial use. · Warning: risk of fire – if installation involves running wiring through a building structure, special wiring methods are needed. Consult National
and Local Codes.

MODEL NUMBER
Q-SET+QZ-30 Q-SET+QZ-60 Q-SET+QZ-96 Q-SET+QZ-DW-96 Q-SET+QZ-DMX-96 Q-SET+QZ- DALI-96

Q-SET LOW VOLTAGE LUMINAIRE POWER SUPPLY

OUTPUT CLASS
CLASS 2 CLASS 2 CLASS 2 CLASS 2 CLASS 2 CLASS 2

MAX LAMP LOAD
30W 60W 96W 96W 96W 96W

PRIMARY VOLTS
120V/277 (60Hz) 120V/277 (60Hz) 120V/277 (60Hz) 120V/277 (60Hz) 120V/277 (60Hz) 120V/277 (60Hz)

LAMP VOLTS
24VDC 24VDC 24VDC 24VDC 24VDC 24VDC

DIMMER RATING
0-10/ELV/MLV 0-10/ELV/MLV 0-10/ELV/MLV 0-10/ELV/MLV
NO NO

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

Q-SET+QZ-30 Q-SET+QZ-60 Q-SET+QZ-96 Q-SET+QZ-DW-96 Q-SET+QZ-DMX-96 Q-SET+QZ- DALI-96
Q-SET+QZ-30 Q-SET+QZ-60 Q-SET+QZ-96 Q-SET+QZ-DW-96 Q-SET+QZ-DMX-96 Q-SET+QZ- DALI-96
Q-SET+QZ-30 Q-SET+QZ-60 Q-SET+QZ-96 Q-SET+QZ-DW-96 Q-SET+QZ-DMX-96 Q-SET+QZ- DALI-96

OUTDOOR

CSA LISTING
Under 30 Volts = LV Wire Burried 0″ to 6″

Outdoor Landscape Lighting – Under 30 Volts CSA Certified for both the U.S. and Canada to the UL-1838 Standard for Landscape Lighting with in-ground enclosure and component power supply operating at less than 30VDC. This listing allows for the LV Q-WIRE to be installed 0″ to 6″ underground.
Pool & Spa – Under 30 Volts CSA Certified for the U.S. to the UL-379 Pool & Spa Power Supply Standard. This listing is intended for power supplies used to power fountain, swimming pool and spa luminaires operating at less than 30V.

OUTDOOR 15 to 30 Volts = LV Wire burried 18″

Outdoor Landscape Lighting – 15 to 30 Volts CSA Certified for both the U.S. and Canada to UL-2108 Standard with a listing of “Low Voltage Luminaire Power Supply” for lamps operating at 12 or 24 volts where the secondary voltage is between 15 to 30 volts. Please note that the secondary wiring must be installed 18″ below grade per the N.E.C.

INDOOR

LV Lighting under 30 Volts

Indoor Open Conductor Systems – Under 30V
CSA Certified for both the U.S. and Canada to UL-2108 Standard as a “Low Voltage Luminaire Power Supply” for lamps operating at 12V or 24V allows for live conductor lighting equipment mounted above 7 feet and other types of LV Lighting equipment, per N.E.C. Article 411. When tested in conjunction with open conductor lighting system.

NOTE:

Refer to the last page.

Q-VAULT 120/277V (50/60HZ) – 24V
FOR CONDUIT CONNECTION WARNING – RISK OF SHOCK. Install power unit 5 feet (1.5 m) or more from the pool or spa and 10 feet (3.05 m) or more from a fountain. Where the power unit is installed within 10 feet (3.05 m) of a pool or spa, connect unit to GFCI protected branch circuit.
FOR POWER SUPPLY CORD CONNECTION WARNING – RISK OF SHOCK. Installed power unit 5 feet (1.5M) or more from the pool, spa, or fountain. Where the power unit is installed (a) indoors within 10 feet (3.05) of a pool, spa, or fountain or (B) outdoors, connect power unit to a receptacle protected by a GFCI.
WARNING – RISK OF FIRE. If installation requires running wire through a building structure, special wiring methods are needed. Contact a qualified electrician.
WARNING – Outdoor Cord-connected unit shall be connected to a GFCI protected hooded flush type cover plate receptacle marked “Wet Location”.
WARNING – Do not use extension cords.
The main Secondary Wiring is intended for shallow burial – less than 6 inches (152 mm)
For Supply connections use wire rated for at least 90C. · SUITABLE FOR INDOOR / OUTDOOR USE · SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES OR SUBMERSIBLE PUMPS · SUITABLE FOR USE WITH LOW VOLTAGE LANDSCAPE LUMINAIRES / FITTINGS

CONTACT YOUR LOCAL DISTRIBUTOR OR Q-TRAN FOR Q-WIRE, Q-CLIK OR PROPER ACCESSORY KITS.

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

ROUGH IN WIRING

1

Excavate a 14″ x 30″ x 16″ deep hole for the Q-VAULT direct burial housing.

2

Dig trenches for primary & secondary wiring to Q-VAULT housing location.

3

Place drain pipe at a 30 degree angle at the lowest slope of land for proper drainage. Fill bottom of pit

with a minimum of 4″ of gravel.

SEE DIAGRAM A

Note: Increase width to 30″ x 30″ when stabilizing bars are used.

1-3
DIAGRAM A

14″ Land
30″
Excavated Hole

Soil

16″

Drain Pipe

Gravel 4″

4

Bring all primary and secondary wiring into housing.

A: Entry location is provided at both the bottom and

side of the Junction Box located on the Q-VAULT

housing.

B: On the bottom of Junction Box there are: (4) 3/4″ NPT and (2) 1/2″ NPT KO’s. SEE DIAGRAM B

C: Using the Field Drill Guide Labels provided in the installation kit you are able to drill for various fitting sizes. Only knock out openings for conduits being utilized in installation. SEE DIAGRAM C

5

After all field wiring has been installed with proper lead lengths, tighten all fittings properly to assure

they are water proof. All drilled entries require Q Click wire

connectors to insure water tight connection. Use

of other connectors voids warranty.

6

Coil and store field wiring in Junction Box area.

Note: Label all wiring for future reference.

4-6
DIAGRAM B

Knock Outs (in)
1/2 3/4

NPT KO’s
2 4

BBoottttoomm VViieeww

DIAGRAM C

Side Label

Front Label

1/2″ Fittings · Front: 8 max · Side: 2 per side max
3/4″ Fittings · Front: 6 max · Side: 1 per side max
1″ Fittings · Front: 3 max · Side: 1 per side max
1-1/2″ Fittings · Front: 2 max
1/2″ Fittings · Front: 1 max

FOR COMPLETE WATER TIGHT GUARANTEE

PRIMARY WIRING IN (120-277V)
Conduit ­ Use Installation Kit · Step 1: Putty · Step 2: Epoxy · Step 3: Syringe Non-conduit – use Q-CLIK NPT.75, Q.750-1E, Q-WIRE 12/2+GND
WARRANTY IS VOID IF THE CORRECT METHOD IS NOT USED.

SECONDARY WIRING OUT (12-24V)
Low voltage wire (non-conduit) · Q-CLIK
· NPT-or knock outs in bottom of Q-VAULT, .5-.75 · MST to drill into the side of the housing, .5-1.25
· Q-WIRE low voltage marine grade UFB wire (recommended) 10-14AWG · Standard Q-CLIK insert
Conduit ­ low voltage, requires Seal Kit (sold separately) · Step 1: Putty · Step 2: Epoxy · Step 3: Syringe

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

7

Clean debris from the top perimeter and install gasket. SEE DIAGRAM D

8

Install door and tighten the 6 door bolts in the number sequence shown. SEE DIAGRAM E

Note: Nut driver can be used to get bolts seated before final tightening. Proper door bolt tightening must be done with a ratchet wrench using a 3/8″ socket at a maximum torque of 50 in-lbs.

9

Attach the provided Support Bars to the Q-VAULT housing using the 6-32 X 5/8 screws. SEE DIAGRAM F

*OPTIONAL: Concrete Pour Ring Nut & Bolt Installation. SEE DIAGRAM G

Level housing and fill hole with gravel to 4″ of below grade. Add soil to
10 surface. SEE DIAGRAM H
All wire entry/exits other than conduit entries MUST use Q-CLIK connectors. Failure to use them will void warranty.

*Gasket

1 6

3 5

Clean Surface

4

2

7
DIAGRAM D

8
DIAGRAM E

Top View of Q-VAULT housing door. Maximum torque 50 in-lbs.

*Gasket only fits one way. Gasket easily slides over Q-VAULT posts. If you are having to force the gasket, it is backwards (Gasket must sit on top of Q-VAULT. No portion should be overhanging).

9
DIAGRAM F

Support bar 6-32×5/8 screws (QTY:4)

DIAGRAM G

5/16 Nut (QT Y:10)
5/16 Nylock Nut (QT Y:10)
5/16×3″ Bolt (QT Y:10)

Shown with lawn Guard Ring Shown without lawn Guard Ring

30″

Land

10
DIAGRAM H

Drain Pipe

Soil

16″

Gravel 4″

11

Remove cover if installed, be sure to store cover and cover gasket in a clean and dry location.

12 Move field wiring out of the way.

NFC tag

Stick your phone through the slot, holding it over the driver’s NFC tag. Read the factory default settings of the driver. Write the desired address and output voltage. Only applicable
to Q-SET+QZ-DMX and
Q-SET-QZ-DALI

10.70″ 2.34″

9.78″

13 Place Q-SET+QZ low voltage luminaire power supply cassette into the
Q-VAULT housing.

14

Landscape Lighting: Landscape Lighting: Bring primary field wiring directly into the Cassette’s primary terminal block through open hole.

Primary Connections:
– Ground to ground labeled on terminal block – Neutral to neutral labeled on terminal block – Hot to hot labeled on terminal block
SEE DIAGRAM I

11-14
DIAGRAM I

Q-SET+QZ Q-VAULT-5
(Must be purchased with Q-VAULT-5) *Install only one Q-SET+QZ per Q-VAULT-5

INPUT

OUTPUT

HOT NEU GND

30W, 60W, 96W

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

HOUSING DOOR: Underside View
CSA Label Desiccant Pouch Spare Parts

HOUSING

HOUSING: Outside View Hole Drill Guide Label: Refer to sticker instructions

NPT
National Pipe Taper
(Conduit Entries)

MST
Machine Screw Thread
(Housing Entries)

For Field Drilled KO’s

Fits

1

Q-ZET

·

Knock Outs (in)
1/2 3/4

NPT KO’s
2 4

Bottom View

Q-CLIK inserts
0.5″ 1.0″ 1.25″

0.75″

INSTALLING Q-SET+QZ
Determine proper lengths and trim to correct length. Low Voltage Connections: 1CH: Q-SET+QZ Connect red wire to +24V on low voltage terminal block. Connect black wire to – on low voltage terminal block .
2CH: Q-SET+QZ-DW Connect black wire to +24V on low voltage terminal block. Connect red wire to Warm on low voltage terminal block. Connect blue wire to Cool on low voltage terminal block.

Non-Dim
HOT NEU GND
Phase Dimmer
HOT NEU GND
0-10V Dimming
HOT NEU GND

DIM +
DIM
+

OUTPUT

INPUT

Cool Warm

1CH
2CH +

LED

30/60/96W
+ _
96W

LED

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

INSTALLING Q-SET+QZ

Low Voltage Connections:
1CH: Q-SET+QZ-DMX / Q-SET+QZ-DALI Connect red wire to +24V on low voltage terminal block. Connect black wire to – on low voltage terminal block.
2CH: Q-SET+QZ-DMX / Q-SET+QZ-DALI Connect black wire to +24V on low voltage terminal block. Connect red wire to Warm on low voltage terminal block. Connect blue wire to Cool on low voltage terminal block.
3CH: Q-SET+QZ-DMX / Q-SET+QZ-DALI Connect black wire to +24V on low voltage terminal block. Connect red wire to R on low voltage terminal block. Connect green wire to G on low voltage terminal block. Connect blue wire to B on low voltage terminal block.
4CH: Q-SET+QZ-DMX / Q-SET+QZ-DALI Connect black wire to +24V on low voltage terminal block. Connect red wire to R on low voltage terminal block. Connect green wire to G on low voltage terminal block. Connect blue wire to B on low voltage terminal block. Connect white wire to W on low voltage terminal block.

DMX
HOT NEU GND
DALI
HOT NEU GND

D+ D_ GND

DMX Controller

DALI

DALI Bus

Controller Power Supply

By others. By others.

OUTPUT

INPUT

1CH
2CH +

LED

30/60/96W
+ _
96W

Cool Warm

LED

R G B_
LED

3CH
96W
+ 4CH
96W

R G B W
LED

SIMPLE AS 1, 2, 3

Use putty provided to seal wires in potting well. It is important that the well is liquid tight so that when the re-enterable epoxy is poured, it

does not escape out the bottom. Be sure the putty is put into the very

bottom of the well to allow ample room for the epoxy. SEE DIAGRAM O

A: The 3M-8882 re-enterable epoxy takes several hours to set. When
2 set it will form a into a water tight “jello” consistency.
B: Mix the two part epoxy together per 3M instructions located on the epoxy packaging.
C: Push all the mixed epoxy together to one end of the bag. Cut the corner of the bag.

3 A: Using the syringe pull the mixed epoxy into the syringe by pulling
the plunger out slowly.
B: Slowly dispense the mixed epoxy from the syringe into the utilized potting wells. SEE DIAGRAM P

Note: Potting is now complete

LAST STEP
Final Door Installation
Gasket and door installed only in one direction · Clean housing area where door gasket will rest · Reinstall clean door gasket.
Before Door is Installed Put velcro desiccant bag in place. Attach the two velcro loop coins on the desiccant bag to the two velcro hook coins on the underside of the housing door. SEE DIAGRAM Q

1
DIAGRAM O
2-3
DIAGRAM P
DIAGRAM Q

Press Putty into Bottom of Well.

4 5
1

2 6
3

Hand ratchet screws in sequence before fully tightineing bolts to max 50 IN- LBS

Note: Install door and tighten the 6 door bolts NOT TO EXCEED 50 IN-LBS. Door bolt tightening must be done with a ratchet wrench using a 3/8″ socket.

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

NEC CODE & UL STANDARDS FOR LIGHTING
Systems Operating at 30 Volts or Less

READ ACROSS & DOWN

SECONDARY WIRE & BURIAL DEPTH

MAX VOLTS
15V AC 30V DC 15V AC
Only 30V AC 30V DC 30V AC 30V DC

UL- NEC
UL 1838 NEC Annex A
UL Pool & Spa NEC 680 UL 2108 NEC 411
NEC Annex A UL 1598 NEC 410

LUMINAIRE LISTING
Low Voltage Landscape Lighting Luminaires
Low Voltage Pool & Spa Luminaires Low Voltage
Lighting Luminaires
Luminaires

POWER SUPPLY TRANSFORMER

Wire Type
& Burial Depth Grade
6″
Below Grade

6″+

Conduit

UF-B (Q-Wire)

Wire to Class 1 NEC – Chapter 3

0-6″

UF-B (Q-Wire)

L.V.Cable

UF-B Underground Feeder – Burial

Max Secondary Volt at Power
Supply with no load (Open Circuit).

NEC = National Electric Code NFPA-70
UL = Underwriters Laboratories Inc.

Article 411.3 (B-2) Listed NEC – 2008
Grounded Isolation for LV Wet Location
Secondary Circuit Protector 25A Max
Open / Bare Conductor (When Tested)

120V
Only

Wet

UL 1838 – LV Landscape Lighting System: 15V AC / 30V DC Max Output at Power Supply – No Load Luminaires + Power Supplies must be UL 1838 Listed as complimentary components for lighting garden, walkway, patio areas, trees and similar outdoor locations with in ground and above ground fixtures; and for certain indoor locations such as atriums and shopping malls. This listing also covers luminaires submersed in or floating on ponds, rivers, water features and lakes or a portable self contained fountains per NEC Article 682 where immersed persons would not be present as defined by luminaire installation instructions.
UL 1838 allows LV Underground Lighting Cable – no other listing permits this wire type. 120V Primary only. Not for indoor use. Note: NEC Annex A = UL 1838

Submersed

Dry or Damp

UL 1838 Low Voltage Landscape NEC Annex A Lighting Power Supply

UL Pool & Spa Low Voltage Pool & Spa

UL 506

NEC

NEC 680

UL 2108 NEC 411 Annex A

Low Voltage Luminaire Primarily for Wet Locations

120V
Only UL Pool & Spa Listing: 15V AC only Max Output at Power Supply – No Load * Indoor & Outdoor

Luminaires 4 Power Supplies must be UL Pool & Spa Listed as complimentary components for lighting a Pool, Spa, permanent fountain

or other bodies of water intended to contain immersed persons. All wiring must be Class 1 per NEC Chapter 3. 120V Primary only.

Install per NEC Article 680

Low Voltage Luminaire for Submersed Locations with immersed persons

UL 2108 – LV Lighting System: 30V AC / 30V DC Max Output at Power Supply – No load Luminaires + Power Supplies must be UL 2108 Listed as complimentary components. This Standard covers: 4113 (A) Listed Systems for exposed bare conductor systems comprised of cable, linear track or the like where the support structure is exposed and current carrying; here the Power Supply must be listed as part of the same identified lighting systems. Note: Use Power Supply as defined in Luminaire installation instructions.

4113 (B) Assembly of Listed Parts covers mono, dual or multi point L.V Luminaires which are an assembly of listed parts if a UL 2108

Low Voltage Luminaire Power Supply is utilized. For wet Location luminaires UL 2108 covers luminaires with up to 30 volt input provided they are Class

I wired per NEC Chapter 3. For wet Location luminaires with inputs not exceeding 15 volts, UL 1838 applies.

Note: NEC Article 411 + Annex A = UL 2108.

Low Voltage Luminaire Primarily for Dry and Damp Locations

UL 1598 – Luminaires: 30V AC / 30V DC Max Output at Power Supply – No load This UL Standard applies to line voltage luminaires for use in non- hazardous locations and allows up to 600 volts input and all wiring must be Class 1 per NEC Chapter 3. Low Voltage luminaires powered by remote transformer are NOT covered by this standard.

Low

Power Supply

Voltage Luminaires Power Supply

General Purpose or Specialty Transformer

Obsolete for LV Remote Dry, Damp & Wet

15V AC/30DC MAX
Output at power supply with no load
15 AC only MAX
Output at power supply with no load
30V AC/30DC MAX
Output at power supply with no load
600 MAX Transformer
300 MAX low Voltage

This Listing does not cover:

· LV Landscape Lighting products and Submersible Luminaires installed in the United States at 15V or less. (UL 1838 is the Standard per NEC-Annex A)

· Swimming Pool & Spa Luminaires (UL Pool & Spa is the Standard per NEC Article 680)

· Low Voltage Lighting Systems powered by remote transformers (UL 2108 is the Standard per NEC 411 & Annex A)

Note: NEC Article 410

Intended for Line Voltage Luminaires for Dry, Damp and Wet Locations

UL 506-General Purpose or Specialty Transformers: 600V Max

This UL Standard is a transformer standard only and is not a complimentary component to any luminaire standard. UL 1838, Pool & Spa and 2108

does not permit the use of UL 506 transformers unless the transformer is additionally tested and subsequently listed to UL 1838, Pool & Spa or 2108. A

UL-506 transformer may be tested as an internal components to a UL-1598 luminaire, to be an integral transformer.

The Scope of UL-506 (Section 1.2) specifically excludes use in Landscape Lighting Systems and for use in Pool & Spa Lighting Systems.

Additionally, a Cord and Plug connection is not permitted. In no instance can a UL-506 transformer be used in Landscape or Pool & Spa

Lighting. A UL 1838, UL Pool Spa and UL 2108 Power Supply may power a UL-1598 luminaire that was listed prior to the UL-2108 effective

date since these Luminaires are required to be Class 1 wired per NEC Chapter 3.

General Purpose Transformer

Conduit (Q-CLIK)
Yes

UF-B (Q-WIRE)
No

L.V. Cable Optional

Exceeds Standard

Complimentary Component

Transformer Power Supply

T

PS

The UL limit of 15 volts AC at the Power Supply under no load (Open Circuit) was established for life safety due to shock potential in wet conditions. The Standard also requires a grounded isolation barrier between the primary and secondary windings. In the Pool & Spa Standard the primary must be 120V & the connection must be in a separate junction box or compartment.

Q-SET = 3 UL Listings
Q-HEX = 2 UL Listings

UL 1838 UL 2108 UL Pool
& Spa
UL 1838 UL 2108

QOM = 1 UL Listings

UL 1838

Key

© COPYRIGHT Q-TRAN, INC. 2023

Power Supply

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

INSTALLATION Q-VAULT – Q-SET+QZ-DALI

© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com

Specification subject to change. Rev-10-06-23

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals