FantiniCosmi C800WIFIOTRQ Wi-Fi Smart Remote Control For Heat Generators
Product Information
Specifications
- Power supply: 230 V – 50 Hz (Power supply unit C800AL) / 2 AA1.5 V alkaline batteries
- Battery life: > 1 year
- Communication protocol: OpenTherm
- Max. mains power consumption: 1 W
- LEDS switch-off: 5 / 10 s from last press; always ON (only with 230V mains supply)
- Temperature adjustment scale: Measurement scale/room Tdisplay
- Temperature display: Celsius/Fahrenheit
- Nominal conductor cross-section for flexible cables: 0.5 to 1 mm2
- Minimum adjusting differential: Thermal gradient of reference 4 K/h
- Maximum room temperature
- Storage temperature
- Software: Class A
- Insulation class: Class II
- Protection rating: IP32
- Degree of pollution: 2
- Mounting: On the wall or on a flush-mounted box type 500-502-503
- Remote control dimensions: 98 x 98 x 20 mm (square base) / 125 x 98 x 20 mm (rectangular base)
- C800AL power supply unit dimensions: 43 x 43/48 x 35 mm
- Weight: 0.100 kg
- Compliant with standards: EN 60730-1 and second parts; Directive 2014/53/EU (RED); 2014/30/EU (EMC); 2014/35/EU (LVD)
- ErP classification (Reg. EU 811/2013 – 813/2013): V; 3% or VI; 4% when combined with a boiler with external probe.
- Product manufactured in Italy.
OPENTHERM® WI-FI SMART REMOTE CONTROL FOR HEAT GENERATORS
Dear customer, thank you for purchasing the Fantini Cosmi smart remote control
model C800WIFIOTRQ suitable for OpenTherm® heat generators for the management
of heating systems and sanitary hot water. This manual holds all the
information required for a correct installation and configuration. You can
also download this manual in digital format and in different languages by
framing the QR code below and entering the product code.
Package contents
- C800WIFIOTRQ remote control
- Rectangular base
- Manual
Warnings
Carefully read the installation instructions, safety warnings, operating
and maintenance instructions in this booklet, which should be kept for further
reference.
- After removing the packaging, check the integrity of the appliance; if in doubt, do not use it.
- Installation of the appliance should only be carried out by qualified technicians in compliance with the current standards.
- The use of any electrical appliance involves observing certain basic rules. In particular:
- DO NOT touch the device with wet hands or wet feet or bare feet.
- DO NOT expose the device to the weather (rain, sun, etc.).
- Before carrying out any maintenance or cleaning work, switch off the power supply.
- DO NOT power the appliance with the cover open.
TECHNICAL DATA
Product Usage Instructions
Installation
Installation and maintenance operations must be carried out with the
system’s electrical voltage switched off and by qualified personnel, in
compliance with the regulations in force.
Power Supply
Separate the front cover from the base by pressing the button on the bottom
edge of the cover and releasing the housing upwards, as shown in the figure.
Battery Power Supply: To power the device with batteries, use 2 AA 1.5V alkaline batteries. Insert the batteries in the battery compartment at the rear of the device, observing the indicated polarities.
Note: If the device is powered by 230V mains don’t insert batteries.
LOW BATTERY WARNING
- 1 flash per minute on display in Stand-by: the batteries are running low and it is still possible to operate the device but they need to be replaced.
- 1 flash per minute and Low Bat appears on the display in Stand-by: the batteries are exhausted the device can no longer be operated and will go to OFF.
Batteries can be replaced at any time without losing the stored settings.
MAINS POWER SUPPLY 230V – 50Hz
It is possible to power the device using the C800AL power supply unit (optional) which requires the flush-mounting. Unscrew the screw as shown in the drawing and lower the plastic cover to gain access to the terminal block for the electrical connections.
Note: Use the square base for 500 and 502 flush-mounting boxes and the rectangular base for 503 flush-mounting box (see page 11).
Insert the cables coming out from the C800AL power supply unit to the C800WIFIOTRQ base.
Hook the C800AL up to the 4 tabs of the base, making sure that the fixing is secure.
Connect the cables to the terminal block, as shown in the table.
Close and screw on the terminal block cover.
CONNECTION TO THE SYSTEM
Installation and maintenance operations must be carried out with the system’s
electrical voltage switched off and by qualified personnel, in compliance with
the regulations in force.
For a correct installation, prepare a dedicated line for the bus connection.
CONNECTION WITH BATTERY POWER SUPPLY
- Unscrew the screw as shown in the drawing and lower the plastic cover to gain access to the terminal block for the electrical connections.
- Connect the terminals 2 and 4 to the heating system.
- Close and screw the terminal box cover. Hang up the front cover to the base.
CONNECTION WITH MAINS POWER SUPPLY 230V – 50HZ
If supplied with 230V, connect the C800AL terminals to the electrical and
heating systems as follows:
WALL FASTENING
For an optimal operation of the device, it is advisable to install the remote
control at a height of approx. 1.5 mt above the floor, in a suitable position
to correctly detect the room temperature (see the example in the drawing).
WALL MOUNTING (for battery power supply only)
The tabs on the back of the base must be removed for the wall mounting. In
this way the remote control will properly adhere to the wall.
FIXING ON FLUSH-MOUNTED BOXES
The remote control is supplied with a square and a rectangular bases to allow
the fixing on flush-mounted boxes type 500-502-503.
Hang up the front cover.
It is now possible to restore power to the system.
When switching on for the first time, wait for the device to communicate with the boiler. When the display LEDs switch off, the device is ready.
USE FROM THE DEVICE
From the device it is possible to select the regulation type of the heating system, the operating modes and the desired current temperatures, along with the management of the sanitary hot water. To customize the program and choose the temperatures of the heating system, it is necessary to pair the device with the Intelliclima+ App and proceed with the relevant configuration (see page 25 and/or APP manual on pdf.fantinicosmi.it).
DISPLAY ACTIVATION
When the remote control is in Stand-by the display is switched off. Lightly
press the central MODE button for 1 second to activate the screen and display
the room temperature. When first turned on, and whether the system is switched
off, OFF will be displayed.
OPERATING MODE SELECTION
With the display switched on, press the central MODE button to view the
current operating mode.
Press the central MODE button again to select the desired operating mode:
OFF- SHUTDOWN PROGRAM
In OFF mode, the system is switched off. During the WINTER season it maintains
the antifreeze temperature, if set (see the APP manual on
pdf.fantinicosmi.it).
MANUAL PROGRAM
The remote control maintains a fixed temperature, for an unlimited time, until
when another program is selected.
AUT- “AUTO” WEEKLY PROGRAM
The device follows the weekly profile set in PROGRAMS. It is possible to
associate one of the three programmable temperatures (off/antifreeze, comfort
temperature and economy temperature) every quarter of an hour, for every day
of the week (see the APP manual on pdf.fantinicosmi.it).
Tcom settable from 2 ÷ 40 °C
Teco settable from 2 ÷ 40 °C
Note: Tcom > Teco
HDL- HOLIDAY” DAILY PROGRAM
The device follows the daily profile set in PROGRAMS. It is possible to
associate one of the three programmable temperatures (off/antifreeze, comfort
temperature and economy temperature) every quarter of an hour (see the APP
manual on pdf. fantinicosmi.it). This sequence will be repeated, identical,
every day.
Tcom settable from 2 ÷ 40 °C
Teco settable from 2 ÷ 40 °C
Note: Tcom > Teco
To use this mode it is necessary to set the current day and time from the user
menu (see page 19) and/or via APP (see the APP manual on pdf.fantinicosmi.it).
ACS- SANITARY HOT WATER PROGRAM (DAILY) **
This function is available only if the boiler board is configured to manage
the production of sanitary hot water. If the ACS operating mode is enabled
(see page 21), during SUMMER or WINTER operation the remote control is also
able to manage a temperature program in certain time slots of the day for the
production of sanitary hot water. The remote control holds a standard program
to manage the production of sanitary hot water that can be freely modified by
the user associating one of the two temperature levels Tcom and Teco (comfort
temperature and economy temperature) every quarter of an hour (see the APP
manual on pdf.fantinicosmi.it). By accessing this mode from the device it is
possible to temporarily modify the current Tcom / Teco temperature . Upon the
subsequent advancement on the profile band it willreturn to the values set
initially. To permanently modify the temperature it is necessary to access the
Intelliclima+ App (see the APP manual on pdf.fantinicosmi.it).
Tcom settable according to the boiler limits
Teco settable according to the boiler limits
Note: Tcom > Teco
- Mode only visible if activated via the device (see page 21-22) and/or via APP (see the APP manual on pdf.fantinicosmi.it).
- To use this mode it is necessary to set the current day and time from the user menu (see page 19) and/or via APP (see the APP manual on pdf.fantinicosmi.it).
**JDL- JOLLY” TEMPORARY PROGRAM *****
It is possible to maintain a certain temperature for a certain number of hours
(from 1 up to 240); after the system will revert to the previously active
program.
Example: Automatic + Jolly at 17°C for 1 week. Once the Jolly period is over, the remote control resumes the operation with the automatic program.
- Mode only visible if activated via APP (see the APP manual on pdf.fantinicosmi.it).
- To use this mode it is necessary to set the current day and time from the user menu (see page 19) and/or via APP (see the APP manual on pdf.fantinicosmi.it).
- Saving of changes is confirmed by a flashing of the last parameter displayed. After saving, the display will return to Stand-by.
TEMPERATURE SETTING
When the display sis witched on, it is possible to modify the temperature
value (Set Point) by pressing the UP or DOWN arrows. The value is increased or
decreased in steps of 0.1°C. In AUT, HOL and ACS modes the temperature
modification made by the device will be temporary and it will return to the
values initially set
upon subsequent advancement along the profile band. To permanently modify the
temperature it is necessary to access the Intelliclima+ App (see the APP
manual on pdf.fantinicosmi.it). Saving of changes is confirmed by a flashing
of the last parameter displayed. After saving, the display will return to
Stand-by.
BASIC SETTINGS
To modify the basic settings you can access to the basic menu:
Saving of changes is confirmed by a flashing of the last parameter displayed. After saving, the display will return to Stand-by.
BASIC SETTINGS MENU
AP Access point
It allows to start the association procedure between the device and the App
(see page 25 and/or the APP manual on pdf.fantinicosmi.it). After
approximately 15 minutes the device will return to the default OFF setting.
- Default value = OFF
- OFF Access Point disabled
- ON Access Point enabled
dAY Current day setting
It allows to set the current day necessary to manage the weekly program (AUT
mode).
- Default value at startup = 1
- Settable values = 1 ÷ 7
- 1=Monday; 2=Tuesday; 3=Wednesday; 4=Thursday; 5=Friday; 6=Saturday; 7=Sunday;
h Current time setting (hour)
It allows to set the current hour necessary to manage the daily and weekly
program (AUT, HOL and ACS mode).
- Default value at startup = 00
- Settable values = 00 ÷ 23
Mi n Current time setting (minutes)
It allows to set the current time necessary to manage the daily and weekly
program (AUT, HOL and ACS mode).
- Default value at startup = 00
- Settable values = 00 ÷ 59
F w Firmware
You can see the firmware release version on this screen.
Sanitary hot water Teco
It allows to set the sanitary hot water temperature in “economy” mode for a
better energy saving, such as during the night or when you are absent for
short periods of time.
- Default Setpoint value = 40°C
- Settable values = Automatic update with boiler limits
- Note: Tcom > Teco
Sanitary hot water Tcom
It allows set the sanitary hot water temperature in “comfort” mode for a
regulation suitable to the moments spent at home.
- Default Setpoint value = 40°C
- Settable values = Automatic update with boiler limits
- Note: Tcom > Teco
Com Instant communication
It allows an instant communication between device and APP during the battery
operation. Once the communication has taken place, the device will return to
communicate with the pre-set cadences (default every 30 minutes, see the APP
manual on pdf.fantinicosmi.it).
- Default value = OFF
- OFF disabled
- ON enabled
- Note: during the 230V mains operation, the communication automatically switches to instantaneous frequency and this function is not visible.
rST Reset basic parameters (user menu)
After enabling reset and confirmed it, the display switches off and the user
menu settings are reset to default values.
- Default value = NO
- NO Reset disabled
- YES Reset enabled
Pw Password
To prevent other users from changing the remote control settings, a password
can be entered to lock the keys. To enable this function, choose an access
code with a value from 1 to 999. This code must be entered, followed by the
MODE button, in order to access any setting, from the temperature control to
the basic or advanced parameters. To disable the key lock, set the value to
“0”.
ADVANCED FUNCTIONS
Further remote control settings can be changed in the Advanced Functions
menu:
It is advisable that a competent and a qualified personnel change the P01 to
P07 parameter values.
Saving of changes is confirmed by a flashing of the last parameter displayed.
After saving, the display will return to Stand-by.
ADVANCED FUNCTIONS MENU
Communication protocol
This function displays the protocol used to communicate with the boiler.
PLS = OpenTherm® Plus
PO2 ACS Enabling
This function enables the sanitary hot water (ACS) management.
Default value = OFF
OFF Disabled
ON Enabled
Po3 Heating water temperature with fixed point regulation
This function allows to set the delivery hot water temperature with the fixed
point regulation. By default the device is pre-set for RADIATOR systems; these
settings can be changed from the APP (see the APP manual on
pdf.fantinicosmi.it).
- Default value = RADIATORS 70°C 20°C ÷ 80°C*
- FAN COIL = 46°C 30°C ÷ 50°C*
- RADIANT PANELS = 42°C 20°C ÷ 45°C*
- These values automatically update with boiler limits.
PO4 Antifreeze temperature
This function avoids blocking the system due to the possible freezing of pipes
during the winter period.
- Default value = 5°C
- OFF = switched off
- 2.0°C ÷ 7.0°C Antifreeze values
Po5 Regulation type
It is possible to select the type of adjustment you want to use.
-
Fixed point: the delivery water fixed temperature is set according to the selected system type: Radiators, Fan Coils, Radiant Panels (see also page 21 – parameter
P03); -
Climatic regulation: the delivery temperature is corrected according to the outside temperature to obtain a constant ambient temperature. Relevant parameters are set by default for RADIATOR systems and can be customized only via APP (see the APP manual on pdf.fantinicosmi.it).
-
Ambient correction: the delivery temperature required by the device is corrected according to the set correction parameter value.
-
Default value = FP
-
FP: Fixed point
-
FPC: Fixed point with ambient correction
-
CL: Climatic
-
CLC: Climatic with ambient correction
P06 Season
Modify the season to activate the regulation in heating mode with ACS or
heating only.
- Default value = WI
- WI = Winter (Heating + ACS if enabled)
- SU = Summer (ACS only if enabled)
Po7 Advanced functions reset
After enabling the reset, the advanced menu settings are reset to default
values.
- Default value = NO
- NO = Reset disabled
- YES = Reset enabled
MAIN EDITABLE FUNCTIONS
| C800WIFIOTRQ| APP Intelliclima +
---|---|---
Mode selection (OFF – MAN – AUT – HOL – JOL)| •| •
Time profiles scheduling (AUT – HOL – JOL – ACS)| –| •
ACS Enabling| •| •
Ambient temperature display| •| •
Comfort and Economy temperature setpoint variation| Temporary| •
Antifreeze temperature setpoint (only in winter)| •| •
Summer/Winter operating modes (only Heating / Heating + ACS)| •| •
Key Lock setting| •| •
Ambient temperature correction (OFFSET)| –| •
Lower and upper temperature limits (Heating and ACS)| –| •
LED brightness level| –| •
AP (Access Point) activation| •| –
Firmware/Software Version| •| •
Device serial number| • (label)| •
Device reset| •| •
Device battery status| •| •
ADDITIONAL SETTINGS FROM THE APP
USE FROM APP
It is possible to proceed with the system parameters configuration only without the need to configure the device to the final WiFi home network (see the APP manual on pdf.fantinicosmi.it).
APP INSTALLATION
Download the Intelliclima+ APP, available free of charge from Google Play
Store and Apple Store. Frame the QR code to be directed to the link directly.
Install the APP and, upon the first activation, create an account by entering the user name and password (an active data connection is required for this). Proceed with the configuration creating a HOUSE and follow the APP wizard. Alternatively, you can add the DEVICE to a previously configured house.
DEVICE PAIRING
Enable the device in AP mode from the user menu:
Saving of changes is confirmed by a flashing of the last parameter displayed.
After saving, the display will return to Stand-by.
The device will remain in active AP mode for approximately 15 minutes. Proceed
with the configuration by adding the C800WIFIOTRQ device and follow the APP
wizard (see the APP manual on pdf.fantinicosmi.it). The device Serial Number
is indicated on the label inside the product.
Note: for further specifications on the device operation via Intelliclima+ APP, please refer to the relevant manual, available in digital format and in several languages by framing the QR code below and typing in product code C800WIFIOTRQ.
For further information and assistance, contact your trusted installer or write to export@fantinicosmit.it indicating the model in use and the problem found.
DISPOSAL
The symbol of the crossed-out wheeled bin indicates that the products must be collected and disposed of separately from household waste. The batteries and integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programs available in your country, contact the local authorities or the sales point where the product was purchased.
WARRANTY CONDITIONS
The conventional warranty lasts 24 months, starting from the date the
equipment is installed. The warranty covers all parts of the equipment, except
those subject to normal wear and tear resulting from use.
FANTINI COSMI S.p.A.
- Via dell’Osio, 6 – 20049 Caleppio di Settala, Milano – ITALY
- Ph. +39 02 95682.222
- Email: export@fantinicosmi.it
- Website: www.fantinicosmi.com
FAQ
-
Q: How long does the battery last?
A: The battery life is more than 1 year. -
Q: What is the communication protocol used?
A: The communication protocol used is OpenTherm. -
Q: Can the device be mounted on a flush-mounted box?
A: Yes, the device can be mounted on a flush-mounted box type 500-502-503.