RED LION NT5000 Industrial Ethernet Managed Switch User Guide

June 9, 2024
RED LION

QSG – NT5000-B
Drawing No. LP1191
Revised 10/2022

NT5000 Industrial Ethernet Managed Switch Series
Quick Start Guide

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this document or on equipment must be observed to ensure personal safety and to prevent damage to either the device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of personnel safety or consequential equipment not equipped with safeguards. Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in a manner not specified.
This guide provides quick installation instructions. Full installation and management details can be found in the manuals at www.redlion.net.

FOR USE IN HAZARDOUS LOCATIONS: Class I, Division 2, Groups A, B, C, and D T4
II 3 G Ex ec IIC T4 Gc
-40°C≤TAMB ≤85°C
UL 21 ATEX 2645X
UL 22.0038X IECEx
UL 22 UKEX 2346X

CAUTION: Risk of Danger
Read complete instructions prior to installation and operation of the unit.
CAUTION: If equipment is used in a manner not specified by Red Lion, the protection provided by the equipment may be impaired.
CAUTION: Do not perform any services on the unit unless qualified to do so.
Do not substitute unauthorized parts or make unauthorized modifications to the unit.
WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been switched off or area is known to be non-hazardous.
WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty.
CAUTION: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage polarity can cause permanent damage to the unit and voids the warranty.
DANGER: Class 1 Laser Product. Do not stare into the laser.
DANGER: Hot Surface.
During operation, take care to avoid coming into contact with a hot surface. Do not touch it over 1 second.

Conditions of Safe Use per ATEX, IECEx and UKEX

  • The equipment shall only be used in an area of at least pollution degree 2, as defined in EN IEC 60664-1.
  • The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with EN IEC 60079-0.
  • The equipment is open-type and intended to be installed in suitable, tool accessible external enclosure to provide fire, shock, mechanical and environmental protections. The enclosure shall be tool accessible and suitable for the location.

Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to the equipment.

Quick Start Instructions

  1. Unpack the NT5000 and verify the following components are enclosed in the package:
    NT5000
    Quick Start Guide

  2. DIN-Rail or panel-mount the switch. This device shall be mounted with one inch gap on each side between adjacent modules to allow air flow.
    The ventilation openings shall not be blocked.

  3. Connect the power supply to the NT5000. The power supply should be NEC/CEC Class 2, LPS or isolated limited energy power source.
    Power is supplied to the device via the screw terminals.
    – The solid state relay output is rated 49 VDC, 1 A Resistive or General Purpose, and shall be NEC/CEC Class 2, LPS or Limited Energy power source.
    – Terminal torque & wire size (range) 0.5 Nm – 0.6 Nm (0.37 ft/lb – 0.44 ft/lb) and 24-12 AWG.
    – Field wiring is to be copper only. Use VW-1 or better wire which is rated minimum 110°C. All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in accordance with the authority having jurisdiction.

Accessing the Web Software Interface

  1. Launch a web browser and enter the IP address of the device into the address bar. By default, the DHCP Client is enabled and if DHCP times out the device can be reached using the fallback address 192.168.1.201.

  2. For the initial login, enter the default username (admin) and press enter.
    You will be prompted to create new login credentials.
    Note: For security purposes, there is no default password to unlock your unit if you forget the password you have created. Make sure to place a copy of your password in a secure location to ensure you are not locked out.

  3. Upon successfully logging in, a dashboard showing a logical view of your unit will appear.

Red Lion Controls Technical Support
If for any reason you have trouble operating, connecting, or simply have questions concerning your new product, contact Red Lion’s technical support.

Model Numbers/Ratings

MODEL PART NUMBER| **OPERATING TEMP| REDUNDANT POWER INPUT VOLTAGE| MAX POWER**
---|---|---|---
NT-5006-000-0000| -40°C to 85°C| 10-49 VDC| 12W
NT-5006-DM2-0000| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-000-0000| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-DM2-0000| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-SC00| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-SC15| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-SC40| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-SC80| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-ST00| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-ST15| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-ST40| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-FX2-ST80| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-GX2-SC00| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-GX2-SC10| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-GX2-SC40| -40°C to 85°C| 10-49 VDC| 12W
NT-5008-GX2-SC80| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-DM2-0000| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-SC00| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-SC15| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-SC40| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-SC80| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-ST00| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-ST15| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-ST40| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-FX2-ST80| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-GX2-SC00| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-GX2-SC10| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-GX2-SC40| -40°C to 85°C| 10-49 VDC| 12W
NT-5010-GX2-SC80| -40°C to 85°C| 10-49 VDC| 12W
NT-5016-000-0000| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-DM2-0000| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-SC00| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-SC15| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-SC40| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-SC80| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-ST00| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-ST15| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-ST40| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-FX2-ST80| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-GX2-SC00| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-GX2-SC10| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-GX2-SC40| -40°C to 80°C| 10-49 VDC| 18W
NT-5018-GX2-SC80| -40°C to 80°C| 10-49 VDC| 18W

Model number may be followed by –CC indicating conformal coating.

Support: support.redlion.net
Website: www.redlion.net
Inside US: +1 877-432-9908
Outside US: +1 717-767-6511
Red Lion Controls, Inc.
35 Willow Springs Circle York, PA 17406

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals