LITE-ON TECHNOLOGY PPQ201707BG96 WWAN Module User Manual
- June 15, 2024
- Lite On Technology
Table of Contents
- PPQ201707BG96 WWAN Module
- Product Information
- Specifications
- Safety Instructions
- Repair and Maintenance Clause
- Federal Communication Commission Interference Statement
- Industry Canada Statement
- Radiation Exposure Statement
- Improper Connection Warning
- Product Usage Instructions
- Introduction
- Product View
- Step-by-Step Usage Instructions
- FAQ (Frequently Asked Questions)
- Q: Who can repair or maintain the US Type Charger-80A?
- Q: What should I do if I suspect damage to the equipment?
- Q: What should I do if I have doubts about proper
- Q: Can I make any modifications to the equipment?
PPQ201707BG96 WWAN Module
Product Information
Specifications
- Product Name: US Type Charger-80A
- User Manual Revision: 2.0
Safety Instructions
The following symbols are used in this manual:
- WARNING: RISK OF PERSONAL INJURY
- WARNING: RISK OF ELECTRIC SHOCK
- WARNING: RISK OF FIRE OR EXPLOSION
- CAUTION: RISK OF DAMAGE TO THE EQUIPMENT
Please read and follow all safety instructions and markings
provided in this document before installing or using the Electric
Vehicle Supply Equipment (EVSE).
The user is responsible for following all applicable codes and
safety standards.
Repair and Maintenance Clause
Only licensed electricians are allowed to repair or maintain
this equipment. General users should not attempt to repair or
maintain it.
Always turn off the input power before repairing or maintaining
the equipment.
Federal Communication Commission Interference Statement
This equipment complies with part 15 of the FCC rules. It must
not cause harmful interference, and it must accept any interference
received. To minimize interference:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and
receiver. -
Connect the equipment into an outlet on a different circuit
than the receiver. -
Consult the dealer or an experienced radio/TV technician for
help.
Any changes or modifications not covered in this guide must be
approved in writing by the manufacturer’s Regulatory Engineering
Department. Unauthorized changes or modifications may void the
user’s authority to operate this equipment.
Industry Canada Statement
This equipment complies with ISED’s license-exempt RSSs. It must
not cause harmful interference and must accept any interference
received.
Radiation Exposure Statement
This equipment complies with ISED radiation exposure limits for
an uncontrolled environment. It should be installed and operated
with a distance of at least 20cm between the radiator and the
user’s body.
Improper Connection Warning
Improper connection of the equipment grounding conductor can
result in a risk of electric shock. If you are unsure about proper
grounding, consult a qualified electrician or serviceman.
Product Usage Instructions
Introduction
The US Type Charger-80A is an Electric Vehicle Supply Equipment
(EVSE) designed for charging electric vehicles. This section
provides an overview of the product and its components.
Product View
The product consists of the following components:
- [Insert description of product components]
Step-by-Step Usage Instructions
-
[Insert step-by-step instructions on how to install the US Type
Charger-80A] -
[Insert step-by-step instructions on how to use the US Type
Charger-80A]
FAQ (Frequently Asked Questions)
Q: Who can repair or maintain the US Type Charger-80A?
Only licensed electricians are authorized to repair or maintain
this equipment. General users should not attempt to repair or
maintain it.
Q: What should I do if I suspect damage to the equipment?
If you suspect damage to the equipment, do not use it and
contact a licensed electrician or the manufacturer for
assistance.
Q: What should I do if I have doubts about proper
grounding?
If you are unsure about proper grounding, it is recommended to
consult a qualified electrician or serviceman for assistance.
Q: Can I make any modifications to the equipment?
No, any changes or modifications to the equipment must be
approved in writing by the manufacturer’s Regulatory Engineering
Department. Unauthorized modifications may void the user’s
authority to operate the equipment.
US Type Charger-80A
User Manual
Revision 2.0
User Manual Rev 2.0
IMPORTANT SAFETY INSTRUCTIONS
This document contains instructions and warnings that must be followed when
installing and using the Electric Vehicle Supply Equipment (EVSE). Before
installing or using the EVSE, read this entire document as well as WARNING and
CAUTION markings in this document.
Safety Instructions
The symbols used have the following meaning:
WARNING: RISK OF PERSONAL INJURY WARNING: RISK OF ELECTRIC SHOCK WARNING: RISK
OF FIRE OR EXPLOSION CAUTION: RISK OF DAMAGE TO THE EQUIPMENT
The information provided in this manual in no way exempts the user of
responsibility to follow all applicable codes or safety standards.
This document provides instructions for the Electric Vehicle Supply Equipment
(EVSE) and should not be used for any other product.
Repair and Maintenance Clause
Only licensed electricians can repair or maintain this equipment. It is
forbidden for general users to repair or maintain it.
Turn off input power before repair or maintenance this equipment.
US Type Charger-80A
1
User Manual Rev 2.0
Federal Communication Commission Interference Statement
This equipment complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This equipment may not cause harmful
interference, and (2) this equipment must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between
the equipment and receiver. Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not covered in this Guide must be approved in writing
by the manufacturer’s Regulatory Engineering Department. Changes or
modifications made without written approval may void the user’s authority to
operate this equipment.
Industry Canada statement:
This equipment complies with ISED’s license-exempt RSSs. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this equipment must accept any interference received,
including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable,
et (2) ce dispositif doit accepter tout brouillage reçu, y compris un
brouillage susceptible de provoquer un fonctionnement indésirable.
US Type Charger-80A
2
User Manual Rev 2.0
Radiation Exposure Statement:
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
greater than 20cm between the radiator & your body.
Déclaration d’exposition aux radiations:
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED
établies pour un environnement non contrôlé. Cet équipement doit être installé
et utilisé à plus de 20 cm entre le radiateur et votre corps.
WARNING: RISK OF PERSONAL INJURY This equipment is intended only for charging
vehicles that do not require ventilation during charging. Please refer to your
vehicle’s owner’s manual to determine ventilation requirements. WARNING: RISK
OF PERSONAL INJURY Do not use extender cables to increase the length of the
charging cable. Maximum length is limited to 25 feet by the National Fire
Protection Agency. WARNING: RISK OF PERSONAL INJURY Do not drag this equipment
by input power cord. WARNING: RF Exposure Information (MPE) This device has
been tested and meets applicable limits for Radio Frequency (RF) exposure.
This equipment should be installed and operated with minimum distance 20 cm
between the radiator & your body. WARNING: RISK OF ELECTRIC SHOCK Basic
precautions should always be followed when using electrical products,
including the following:
· Read all the instructions before using this equipment. · This equipment
should be supervised when used around children. · Do not put fingers into the
EV connector. · Do not uses this equipment if the flexible power cord or EV
cable is frayed, has broken
insulation, or any other signs of damage. · Do not use this equipment if the
enclosure or the EV connector is broken, cracked, open,
or shows any other indication of damage.
WARNING: RISK OF ELECTRIC SHOCK
US Type Charger-80A
3
User Manual Rev 2.0
Improper connection of the equipment grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or serviceman if you are
in doubt as to whether the product is properly ground-ed.
WARNING: RISK OF ELECTRIC SHOCK Do not touch live electrical parts. Incorrect
connections may cause electric shock. WARNING: RISK OF ELECTRIC SHOCK Do not
remove cover or attempt to open the enclosure. No user serviceable parts
inside. Refer servicing to qualified service personnel. WARNING: RISK OF FIRE
OR EXPLOSION To reduce the risk of fire, replace only with same type and
rating of fuse. WARNING: RISK OF FIRE OR EXPLOSION This equipment has internal
arcing or sparking parts which should not be exposed to flammable vapors. It
should not locate in a recessed area or below floor level. Automatic reset
feature provided. WARNING: RISK OF FIRE OR EXPLOSION Do not use this device
with an extension cord. CAUTION: RISK OF DAMAGE TO THE EQUIPMENT Do not
operate this equipment in temperatures outside its operating range of -35°C to
+55°C (-31°F to +131°F). CAUTION: RISK OF DAMAGE TO THE EQUIPMENT Store this
equipment in a clean dry place in temperatures between -40°C and +80°C (-40°F
to +176°F). CAUTION: RISK OF DAMAGE TO THE EQUIPMENT Not exceed maximum 150V
to ground.
SAVE THESE INSTRUCTIONS
US Type Charger-80A
4
User Manual Rev 2.0
Contents
1 Introduction ………………………………………………………………………………………………………………………… 8 Product view
………………………………………………………………………………………………………………. 8
2 Specifications …………………………………………………………………………………………………………………….. 12 Product
specifications…………………………………………………………………………………………………12
3 Installation ………………………………………………………………………………………………………………………… 14 Before
installation………………………………………………………………………………………………………14 3.1.1 Safety check
………………………………………………………………………………………………….. 14 3.1.2 Grounding instructions
…………………………………………………………………………………… 14 Tools & parts required for
installation…………………………………………………………………………..15 Charge Point
Installation……………………………………………………………………………………………..15 Input Power Cord
Installation ……………………………………………………………………………………… 21 Adjust Max.Output Current
………………………………………………………………………………………… 24 Holster
Installation……………………………………………………………………………………………………..25
4 Getting started …………………………………………………………………………………………………………………… 28 Access
charger via browser [for SC/IC Only]…………………………………………………………………..28 4.1.1
Setting up the local network ……………………………………………………………………………. 28 4.1.2 Setting
up the local network (using Ethernet cable)……………………………………………. 29 4.1.3 Log in
……………………………………………………………………………………………………………. 29 Web-page overview [for SC/IC
only]……………………………………………………………………………..34 4.2.1 Menu overview
……………………………………………………………………………………………… 34
US Type Charger-80A
5
User Manual Rev 2.0
4.2.2 Configuration menu ……………………………………………………………………………………….. 35 4.2.3
Maintenance menu ………………………………………………………………………………………… 35 4.2.4 EVSE
Status……………………………………………………………………………………………………. 37 4.2.5 LLM Status menu [for IC
only]………………………………………………………………………….. 37 4.2.6 Security menu
……………………………………………………………………………………………….. 38 Configuration
……………………………………………………………………………………………………………. 39 4.3.1 Factory settings
……………………………………………………………………………………………… 39 4.3.2 Station
settings………………………………………………………………………………………………. 40 4.3.3 OCPP settings
………………………………………………………………………………………………… 42 4.3.4 Communication settings
…………………………………………………………………………………. 49 Maintenance
…………………………………………………………………………………………………………….. 61 4.4.1
Reboot………………………………………………………………………………………………………….. 61 4.4.2 Firmware
upgrade………………………………………………………………………………………….. 64 EVSE Status
………………………………………………………………………………………………………………. 65 LLM Status (IC support only)
……………………………………………………………………………………….. 66 4.6.1 LLM
information…………………………………………………………………………………………….. 66 4.6.2 Gateway/Client group
table…………………………………………………………………………….. 67 4.6.3 Operation
mode…………………………………………………………………………………………….. 68 Security
……………………………………………………………………………………………………………………. 76 4.7.1 Change password
…………………………………………………………………………………………… 76 5 Operations
………………………………………………………………………………………………………………………… 77 Charging status
indicators……………………………………………………………………………………………77 Authorization (for IC only)
………………………………………………………………………………………….. 78 5.2.1 Online Authorization
………………………………………………………………………………………. 78 5.2.2 Local Authorization
………………………………………………………………………………………… 78 Charging an Electric Vehicle (EV)
…………………………………………………………………………………. 79
US Type Charger-80A
6
User Manual Rev 2.0
5.3.1 Plug and Charge …………………………………………………………………………………………….. 79 5.3.2 RFID card
(for IC only) …………………………………………………………………………………….. 79 Stop charging
……………………………………………………………………………………………………………. 79 5.4.1 Interrupt charging
………………………………………………………………………………………….. 79 5.4.2 Auto restart
…………………………………………………………………………………………………… 80 5.4.3 Power outage recovery
…………………………………………………………………………………… 80 General
care………………………………………………………………………………………………………………80 Customer support
……………………………………………………………………………………………………… 80
US Type Charger-80A
7
1 Introduction
User Manual Rev 2.0
This user manual applies to “80A Level 2 AC Charger for Plug-in Electric
Vehicles (PEVs) and Battery Electric Vehicles (BEVs)”. The Level 2 Electric
Vehicle Supply Equipment (EVSE) with 80A capabilities will be used in North
America. It can provide a shorter charging time than the 16A and 32A EVSE.
!!! Any unauthorized modifications will void the manufacturer’s warranty!!!
Product view
Figure 1-1 Front view
US Type Charger-80A
8
Box Contents Inside the box, you will find the following accessories.
User Manual Rev 2.0
Figure 1-2 Box contents
Table 1-1 Accessories in the box
Item
Description
1
Basic Charger-80A Intelligent Charger-80A
2
Mounting Bracket
3
Holster ASSY
4
Accessories Bag
QTY
Remark
1
1
Attached to the back of the charge point
1
With Hook x1, Holster x1 & M4xL15 tapping screw x2
1
2 AWG Ring terminal lug x 2, #8 AWG Ring terminal lug and M6 machine screw x1
Carton Opening Process 1. Open the carton and remove the EPE Foam
Figure 1-2 Opening the carton
US Type Charger-80A
9
User Manual Rev 2.0
Figure 1-3 Charge point device
2. Take out the charge point and then remove the mounting bracket before
installing it.
US Type Charger-80A
10
User Manual Rev 2.0
Figure 1-4 Take out the charge point
Figure 1-5 Remove the mounting bracket
US Type Charger-80A
11
2 Specifications
User Manual Rev 2.0
Product specifications
Item Application Voltage (Vac) Frequency (Hz) Current (Rms) Charging Connector
Indications
Wi-Fi Ethernet BLE Cellular
RFID
Display Data Protocol Operation Temp. Storage Temp. Mounting Type Wiring Type
Enclosure Level Impact Resistance Dimension (H x W x D) Web Portal Management
Console Management Certification
Table 2-1 Product specifications
BC80A
SC80A
Residential
Residential 208/240VAC (-20% ~ + 15%), Single Phase
60Hz Max. 80 A SAE J1772 Type 1
· Green Steady: Ready · Green Flashing (Fast): Authorized, wait for EV Connect · Green Flashing (Slow): Suspend (Occupying) · Blue Flashing (Slow): Charging · Red Steady: Unrecoverable Fault · Red Flashing (Slow): Recoverable Fault · Yellow Flashing (Slow): Booting / Firmware Upgrading / Out of Service Remark · Fast Flash: On Time 300ms, Off Time 200ms, 2Hz · Slow Flash: On Time 1200ms, Off Time 800ms, 0.5Hz
IC80A Commercial
N/A
802.11 b/g/n
N/A YES
N/A
YES N/A M2M connection (LTE CAT.M1 / CAT.NBIoT)
ISO 14443 A/B,
N/A
ISO 15693,
NEMA interoperability protocol
N/A
116(L)8.5(W)37(H)mm, 5.57mm CHARACTER HEIGHT, 5*8 DOT MATRIX, OLED 20×2
N/A
OCPP 1.6
-35 ~ 55 (-31 to 131)
-40 ~ 80 (-40 to 176)
Wall mount / Pole mount (optional) Hard-wired NEMA 3R IK10
14.1″x10.6″x5.5″
N/A
Yes
Yes
UL 1998/2231/2594
FCC Part 15B
US Type Charger-80A
12
User Manual Rev 2.0
Item
BC80A
SC80A
IC80A
FCC Part 15.247 (Bluetooth 2.4GHz)
FCC Part 15.225 (RFID 13.56MHz) FCC Part 15.247 (WLAN 2.4GHz)
Energy Star
N/A
FCC Part 22/24/27
US Type Charger-80A
13
3 Installation
User Manual Rev 2.0
Before installation
3.1.1 Safety check
· Check for transport damages. · Before connecting the product to the power
supply, check that the power supply voltage and
current rating corresponds with the power supply details shown on the product
rating label.
CAUTION: Disconnect the power supply before installing or repairing the charge
point. Failure to do so may result in physical injury or damage to the power
supply system and the charge point. CAUTION: Avoid touching or pressing the
OLED screen all times, as this may result in damage to the OLED screen.
DANGER: RISK OF SUFFOCATION Keep any packing materials away from children
these materials are a potential source of danger, e.g. suffocation. CAUTION:
Cord extension sets are not allowed to be used.
The charge point must be installed only by a licensed electrician in
accordance with the provisions of the local electrical industry construction
and should comply with national electrical codes and standards.
Before installing the charge point, make sure you have read all of these
instructions in this manual and fully understand its contents.
Appropriate protection is required when connecting to a main switchboard. The
tools and parts used as outlined in the section “Tools & parts required for
installation”.
3.1.2 Grounding instructions
The charge point must be implemented equipment grounding through a permanent
wiring system or an equipment grounding conductor. Use a wire with a dedicated
grounding wire and a ring terminal and connected to the equipment ground
terminal block for grounding.
US Type Charger-80A
14
User Manual Rev 2.0
Tools & parts required for installation
Tool
Mounting Bracket Holster ASSY Screw
Table 3-1 Tools & parts required for installation
QTY Model
Size
1
All 222x173x9 mm
1
All 58x58x70 mm
4
All Tapping: #12
Mechanical: M6
1
All Mechanical: M6
Supplier
All Product Model Model Accessories Commercially Available Commercially
Available Model Accessories
Wire, Copper
3
Heat Shrink Tube
3
Terminal
3
Conduit
1
Philips Screwdriver
1
Torx Screwdriver
1
Hexagon Socket
1
Torque Wrench
1
All 2 AWG
Commercially Available
For 2 AWG wire
Model Accessories
All Color: Red, Black,
Green.
All
For 2 AWG wire
Model Accessories
All
1 inch
All PH3
All T20
All
5/16
All 40 kgf-cm min
Commercially Available
Commercially Available Commercially Available Commercially Available
Commercially Available
Remark Fasten charge point to the wall Hold EV charging plug Fasten Mounting
Bracket & Hook Fasten charge point &Mount bracket
Protect wires & terminals
Connect input wires to the terminal block Protect power cable
Tighten #12 Tapping screws
Charge Point Installation
1. Disassemble top cover
Figure 3-1 Loosen 1 pc M4 screw.
US Type Charger-80A
15
User Manual Rev 2.0 Figure 3-2 Use flat tip screw driver to push snap then open front cover.
Figure 3-3 Loosen 5 pcs M4 screw then open Install cover.
US Type Charger-80A
16
2. Find SIM card socket. (only for Intelligent Charger)
User Manual Rev 2.0
Figure 3-4 Position of SIM card socket
3. Insert SIM card.
3-1 Unlock the SIM Card socket
Figure 3-5 SIM card socket and cover Open/Close direction
US Type Charger-80A
17
3-2 Open the socket then install Sim card
User Manual Rev 2.0
Figure 3-6 open the socket cover
Figure 3-7 input the SIM Card
4. Secure the main body mounting bracket to the wall with appropriate screw.
Follow applicable accessibility requirements for the mounting position. The
unit shall be stored or located at a sufficient height. For indoor site, it
should not be lower than 18 inches (450 mm) and not higher than 4 feet (1.2m).
For outdoor site, it should not be lower than 24 inches (600 mm) and not
higher than 4 feet (1.2m). Refer to Article 625, NEC.
The mounting bracket has ten screw holes. If only two screws be used to fasten the mounting bracket, the screws should pass through the middle two screw holes of the mounting bracket. The other screw holes are reserved for the user.
US Type Charger-80A
18
User Manual Rev 2.0
Figure 3-8 Fasten mounting bracket
Figure 3-9 Screw holes of mounting bracket
Screw sizing suggestion:
A. For masonry walls, use M6 mechanical screws. (Commercially Available) B. For finished walls supported by wood studs, use #12 tapping screws. (Model Accessories) C. Please refer to the following torque. The actual torque is according to the wall material.
Screw M6 #12
Torque 25 kgf.cm min 21.7 lb-in min 25 kgf.cm min 21.7 lb-in min
5. Fasten charge point onto mounting bracket. 5-1. Put the charge point on the mounting bracket.
5-2. Fasten charge point on mounting bracket by tightening M6 screw.
5-3. Please refer to the following torque.
Screw M6
Torque 31 kgf.cm 26.9 lb/in
US Type Charger-80A
19
User Manual Rev 2.0
Figure 3-10 Charge point and mounting bracket
Figure 3-11 Tighten M6 screw
US Type Charger-80A
20
User Manual Rev 2.0
Input Power Cord Installation
1. Choose the appropriate conduit in accordance with all applicable state,
local and national electrical codes and standards.
Figure 3-12 Conduit.
2. Clamp copper terminal to connect copper wire. The clamp point is covered
by heat shrink tube for protecting.
2-1 Refer to the following wire specification. Use conductor type other than
RHH, RHW and RHW-2 with outer covering.
Model Charger-80A
Terminal L1, L2 G
Conductor 2 AWG 8 AWG
Rating 90C copper wire
Figure 3-13 Copper terminal, heat shrink tube and copper wire.
US Type Charger-80A
21
User Manual Rev 2.0
3. Electrical wiring to the charge point. 3-1. Fold the wire end to pass
through the conduit and insert them into the input hole (choose input
direction 1 or 2 and open cap)
.
Figure 3-14 Cable input position
3-2. Fasten the copper wire on the corresponding terminal block. The wiring
instruction is printed in front of the terminal block (L1/L2/G).
Figure 3-15 Input wiring position.
US Type Charger-80A
22
User Manual Rev 2.0
3-3. Use the following torque to connect the wire terminal to the terminal
block.
Screw M6
Torque 31 kgf.cm 26.9 lb-in
CAUTION: To reduce the risk of fire, connect only to a circuit provided with
100 amperes maximum branch circuit overcurrent protection in accordance with
the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code,
Part I, C22.2.
CAUTION: If this unit is installed outdoors, the outlet must be rated for
outdoor installation. The outlet must be installed properly to maintain the
proper NEMA rating of the enclosure.
3-4. Lock the conduit on the enclosure. Please refer to the following torque.
Conduit 1 ”
Torque 35 kgf.cm 30.36 lb-in
3-5. Reassemble Instant cover and Front cover then Fasten M4 screw.
Screw M4
Torque 15 kgf.cm 13 lb-in
US Type Charger-80A
23
Adjust Max. Output Current
1. Refer to Chapter 4 for how to log into web portal. 2. Adjust Max. Output
Current from web portal.
User Manual Rev 2.0
Figure 3-16 Modify Current in Max. Amperage FW Setting field and press “Apply” button.
US Type Charger-80A
24
Holster Installation
1. Separate the holster from the hook.
User Manual Rev 2.0
Figure 3-16 Separate the holster
2. Fasten the hook on the wall with appropriate screws. 2-1. For finished
walls supported by wood studs, use 2PCS screws (#12 tapping or M6 ) . 2-2. The
recommend torque is 25 kgf.cm (21.7 lb-in).
Figure 3-17 Secure the hook
US Type Charger-80A
25
3. Make the holster face up and combine with the hook.
User Manual Rev 2.0
Figure 3-18 Secure the holster
4. Rotate the holster down totally.
Figure 3-19 Rotate the holster
US Type Charger-80A
26
User Manual Rev 2.0
5. Keep the holster in this state and tighten screws completely. 5-1. The
recommend torque is 6 kgf.cm (5.2 lb-in). The screws make the combination
firm.
Figure 3-20 Tighten screws
6. Place EV charging plug on the holster.
Figure 3-21 Place EV charging plug
US Type Charger-80A
27
4 Getting started
User Manual Rev 2.0
Access charger via browser [for SC/IC Only] 4.1.1 Setting up the local network
The default factory setting of networks is Wi-Fi AP mode. You can get the SSID
number from the label on the side of the charge point. Please refer to the
Figure 4-1. The SSID name is IC80A+SN. Then you can connect a computer/smart
phone/iPad to the charge point using Wi-Fi. The default password is
“SN+@IC80A”
Ex. SN : Ex-1193-1A13-1-1234-2444,
The SSID name is IC80AEx-1193-1A13-1-1234-2444.
The password is Ex-1193-1A13-1-1234-2444@IC80A.
Figure 4-1 SN on the main label
US Type Charger-80A
28
User Manual Rev 2.0
4.1.2 Setting up the local network (using Ethernet cable)
Install communication cable between PC and charge point. Please refer to the
Figure 4-2.
USB-RS232 cable
Figure 4-2 Communication cables install diagram
After wiring connection turn power on, Launch TeraTerm or PuTTY (SSH Client
for Windows system) on PC to access to IC-80A Charger through Serial Port. You
should see the login screen(TeraTerm for example):
Go to Setup > Serial Port… to modify Speed to <115200> and press
US Type Charger-80A
29
User Manual Rev 2.0
To be able to Log-in through Serial Port, you should enter “user” in the user name box. The default password is “user123USER123”.
Send “ifconfig” command to get charge point’s IP address from Ethernet interface. This IP address will be used in section 4.1.3 to a web browser address field:
US Type Charger-80A
30
User Manual Rev 2.0
Connect a computer to the charge point using an Ethernet cable. Ethernet cable
RJ45 Connector Grommet RJ45 Cable
NOTE
Please do not remove the grommets. Instead, let Ethernet cable pass through
them. Use tools to combine the RJ45 connector with RJ45 cable.
By this way, the IP level could be >= IP55. The Ethernet cable diameter should
be 3.5mm 5mm.
US Type Charger-80A
31
User Manual Rev 2.0
Set up a dynamic IP Address on your computer. For windows system, choose
“Obtain an IP address automatically” in Internet Protocol Version 4 (TCP/IPv4)
Properties dialog like below figure.
US Type Charger-80A
32
User Manual Rev 2.0
4.1.3 Log in
Open a web browser and enter the IP address in the address field of the browser and press enter.
Connection Method Wi-Fi
Ethernet cable
IP address 10.10.0.1 169.254.XXX.XXX
characteristic Static IP address Different with each charge point
Now you should see the login screen:
To be able to configure the charge point you should enter “admin” in the user name box. The default password is “howru2RU2IC3”.
US Type Charger-80A
33
User Manual Rev 2.0
Web-page overview [for SC/IC only] 4.2.1 Menu overview
To navigate via the web browser, use the menu items available: Configuration,
Maintenance, EVSE Status, LLM Status, and Security.
Logout button
Menu List
US Type Charger-80A
34
4.2.2 Configuration menu
When you choose the Configuration menu, a sub menu will appear:
User Manual Rev 2.0
The “Factory Settings” tab is used to display the information of the charge
point. The “Station Settings” tab is used to set up the configuration
regarding to the charge point itself. The “OCPP Settings” tab is used to set
up the custom properties for uses in OCPP 1.6 services. The “Communication
Settings” tab is used to set up the network connection and load
management.
US Type Charger-80A
35
4.2.3 Maintenance menu
When you choose the Maintenance menu, a sub menu will appear:
User Manual Rev 2.0
The “Command” screen can be used to restart the charge point and reset
settings to Manufacturing default.
The “Charging Profile Data” screen can be used to show and clear charging
profiles including “Charge Point Max Profile”, “Tx Default Profile” and “Tx
Profile”. Charging Profile is defined in OCPP
1.6 specification. The “Local Authorization” screen can be used to display and
clear the Local Authorization List and
Authorization Cache List. Both lists are defined in OCPP 1.6 specification.
The “Firmware Upgrade” screen can be used to upgrade the firmware of the
charge point.
US Type Charger-80A
36
4.2.4 EVSE Status
When you choose the EVSE Status menu, a sub menu will appear:
User Manual Rev 2.0
The “Electric Vehicle Supply Equipment Status” can be used to show the
information of EVSE. Usually the information is only for diagnostic use.
4.2.5 LLM Status menu [for IC only] When you choose the LLM Status menu, a sub
menu will appear:
The “Local Load Management Status” screen shows the Local Load Management (LLM) settings and current Master/Slave group member list.
US Type Charger-80A
37
4.2.6 Security menu
When you choose the Security menu, a sub menu will appear:
User Manual Rev 2.0
The “Change Password” screen can be used to change the password of users for this web portal.
US Type Charger-80A
38
User Manual Rev 2.0
Configuration
4.3.1 Factory settings
Clicking on the “Configuration” and then “Factory Settings” link will bring up
the following screen:
Basic Information Charge Point Vendor The vendor’s name of the charge point. Charge Point Model The model’s name of the charge point. Charge Point Serial Number The unique serial number of the charge point. Firmware Version The software version of the charge point. Meter Type The meter type of the charge point. Reader Type The reader type of the charge point. [Support only on IC] DSMR Type The DSMR type of the charge point. Production Date The production date of the charge point.
US Type Charger-80A
39
User Manual Rev 2.0
Charging Connector Information Number of Connectors Number of connectors of
the charge point. Connector Type Indicates type 1 or type 2 cable installed
in the charge point. Max Amperage Connector The maximum charging current of
the connector capability. A charge point may have multiple connectors
installed. For SC/IC series, there is only one connector on them.
4.3.2 Station settings
Clicking on the “Configuration” and then “Station Settings” link will bring up
the following screen. Since the page is too long to display, we separate it to
2 screens. On this page you can change the properties of the charge point.
Click the “Apply” button at the right side of the property when the value is
changed.
US Type Charger-80A
40
User Manual Rev 2.0
General Settings
Output Power Type AC or DC output power. For SC/IC series, this value is always “AC”.
Power Phase Connected Input power phase connected to the charge point to indicate single phase or three phases. For SC/IC series, this value is always “1”.
Max Amperage HW Setting The DIP switches (Hardware) settings to indicate the maximum charging current.
Max Amperage FW Setting The software settings to indicate the maximum charging current.
PWM Amperage The PWM setting for charging current when the charge point is online. This signal is to tell EV how much current is allowed to use.
Real Amperage The real-time charging current detected by the charge point.
Cold Load Pickup Max Delay Default cold load pickup delay is 120s ~ 720s. The max value could be changeable by this property.
Plug and Charge ID If the value is present, the charge point needs to support plug and charge scenario by using the specific identifier. If absent, authorization for each session is required. This ID must be 8 or more characters.
Reservation Supported If true, the charge point will support reservation related messages from Central System.
Resume Charge After Reboot Indicate if the charge point resumes charging after power recycle. If true, the charge point will resume charging according to UL regulations. If false, the charge point will not resume charging.
RFID Reader Indicate if RFID reader is available. [for IC only]
Ventilation Required Indicate if ventilation equipment is required. If set this option to yes, a ventilation fault will occur when the EV report for need ventilation equipment. Recommend setup value are shown below according to the place and ventilation equipment available or not.
Place
Ventilation Equipment Available
Ventilation Equipment Not Available
Indoor
No
Yes
Outdoor
No
No
US Type Charger-80A
41
User Manual Rev 2.0
Skip HeartBeat Message When set to true, the Charge Point should skip sending
a Heartbeat.req PDU when another PDU has been sent to the Central System
within the configured heartbeat interval. Default value is Yes. LED brightness
The user can modify the LED brightness according to the user’s environment
and preferences. The default setting is 50% brightness.
Other Information Last Boot Time Show last boot time.
4.3.3 OCPP settings
Clicking on the “Configuration” and then “OCPP Settings” link will bring up
the following screen, since the page is too long to display, please using
scrollbar to check remaining pages.
US Type Charger-80A
42
User Manual Rev 2.0
On this page you can change the properties just for the charge point. Click
the “Apply” button at the right side of the property when the value is
changed. Remote Control Settings Remote Control Type: The remote-control mode
accepted by charger. Options are
APP: Charger is controlled by mobile APP. OCPP: Charger is controlled by OCPP
1.6 protocol. Service Settings Charge Point ID The identity of the charge
point as known in the OCPP Central System. Protocol Name The name and
version of OCPP is running in the charge point. Central System URL The URL
of the OCPP v1.6 Central System service. Basic Auth ID The ID for BASIC
authentication in HTTPS (SSL/TLS) connections.
US Type Charger-80A
43
User Manual Rev 2.0
Basic Auth Password The password for BASIC authentication in HTTPS (SSL/TLS)
connections. FTP Server Username The username of the FTP Server for OCPP to
download firmware files and upload diagnostic file. FTP Server Password The
password of the FTP Server for OCPP to download firmware files and upload
diagnostic file. Message Transport Layer Select the transport layer of the
OCPP service that will be used. The available option is WS and WSS.
WS: Connection from charge point to OCPP Server uses WebSocket protocol. WSS:
Connection from charge point to OCPP Server uses Secure WebSocket protocol.
Boot Notification Interval Interval of re-sending BootNotification.req if
not accepted by Central System. Boot Notification Retries Number of times to
retry sending BootNotification.req. “-1” means unlimited “0” means don’t
retry. PDU Timeout Interval until the charge point stop waiting for a PDU
response. Download Firmware Interval Interval of downloading firmware from
Central System. Download Firmware Retries Number of times to retry
downloading firmware. Upload Diagnostics Interval Interval of uploading
diagnostic file to Central System. Upload Diagnostics Retries Number of
times to retry uploading diagnostic file.
US Type Charger-80A
44
User Manual Rev 2.0
OCPP1.6 Settings
These settings are defined and requested for support in OCPP 1.6
specification.
AllowOfflineTxForUnknownId If set to yes, an unknown ID (not in
Authorization and Cache List) will be accepted and start the charging session
when charge point is not connected to central system.
AuthorizationCacheEnabled If set to yes, the Authorization Cache is enabled.
AuthorizeRemoteTxRequests Whether a remote request to start a transaction in
the form of a RemoteStartTransaction.req message should be authorized
beforehand like a local action to start a transaction.
BlinkRepeat Number of times to blink the charge point lighting when
signaling. This value is not changeable for IC/SC.
ClockAlignedDataInterval Size (in seconds) of the clock-aligned data
interval. This is the size (in seconds) of the set of evenly spaced
aggregation intervals per day, starting at 00:00:00 (midnight).
US Type Charger-80A
45
User Manual Rev 2.0
ConnectionTimeOut Interval (from successful authorization) until incipient
Transaction is automatically canceled, due to failure of EV driver to
(correctly) insert the charging cable connector(s) into the appropriate
socket(s).
GetConfigurationMaxKeys Maximum number of requested configuration keys in a
GetConfiguration.req PDU.
HeartBeatInterval Defines the heartbeat interval.
LightIntensity Percentage of maximum intensity at which to illuminate the
charge point lighting. This value is not changeable for IC/SC.
LocalAuthorizeOffline Whether the charge point, when offline, will start a
transaction for locallyauthorizedidentifiers.
LocalPreAuthorize Whether the charge point, when online, will start a
transaction for locally authorized identifiers without waiting for or
requesting an Authorize.conf from Central System.
MaxEnergyOnInvalidId Maximum energy in Watt-hour (Wh) delivered when an
identifier is invalidated by Central System after start of a transaction.
MeterValuesAlignedData Clock-aligned measurand(s) to be included in a
MeterValues.req PDU, every ClockAlignedDataInterval seconds. Supported value
are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or
any combination of these 4 value.
MeterValuesAlignedDataMaxLength Maximum number of items in a
MeterValuesAlignedData configuration key.
MeterValuesSampledData Sampled measurands to be included in a
MeterValues.req PDU, every MeterValueSampleInterval seconds. Supported value
are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or
any combination of these 4 value.
MeterValuesSampledDataMaxLength Maximum number of items in a
MeterValuesSampledData configuration key.
MeterValueSampleInterval Interval between sampling of metering (or other)
data, intended to be transmitted by “MeterValues” PDUs
MinimumStatusDuration The minimum duration that a charge point or connector
status is stable before a StatusNotification.req PDU is sent to Central
System.
NumberOfConnectors The number of physical charging connectors of this charge
point.
US Type Charger-80A
46
User Manual Rev 2.0
ResetRetries Number of times to retry an unsuccessful reset of the charge
point.
ConnectorPhaseRotation The phase rotation per connector in respect to the
connector’s energy meter. Possible values per connector are:
NotApplicable (for single phase) Unknown (not (yet) known) RST (Standard
Reference Phasing) RTS (Reversed Reference Phasing) SRT (Reversed 240 degree
rotation) STR (Standard 120 degree rotation) TRS (Standard 240 degree
rotation) TSR (Reversed 120 degree rotation)
ConnectorPhaseRotationMaxLength Maximum number of items in a
ConnectorPhaseRotation configuration key.
StopTransactionOnEVSideDisconnect When set to true, the charge point SHALL
administratively stop the transaction when the cable is unplugged from the EV.
StopTransactionOnInvalidId Whether the charge point will stop an ongoing
transaction when it receives a non-accepted authorization status in a
StartTransaction.conf for this transaction.
US Type Charger-80A
47
User Manual Rev 2.0
StopTxnAlignedData Clock-aligned periodic measurand(s) to be included in the
TransactionData element of StopTransaction.req MeterValues.req PDU for every
ClockAlignedDataInterval of the charging session. Supported value are
Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any
combination of these 4 value.
StopTxnAlignedDataMaxLength Maximum number of items in a StopTxnAlignedData
configuration key.
StopTxnSampledData Sampled measurands to be included in the TransactionData
element of StopTransaction.req PDU, every MeterValueSampleInterval seconds
from the start of the charging session. Supported value are Current.Import,
Energy.Active.Import.Register, and Temperature, Voltage or any combination of
these 4 value.
StopTxnSampledDataMaxLength Maximum number of items in a StopTxnSampledData
configuration key.
SupportedFeatureProfiles A list of supported Feature Profiles. Possible
profile identifiers: Core, FirmwareManagement, LocalAuthListManagement,
Reservation, SmartCharging and RemoteTrigger.
SupportedFeatureProfilesMaxLength Maximum number of items in a
SupportedFeatureProfiles configuration key.
TransactionMessageAttempts How often the charge point should try to submit a
transaction-related message when Central System fails to process it.
TransactionMessageRetryInterval How long the charge point should wait before
resubmitting a transaction-related message that Central System failed to
process.
UnlockConnectorOnEVSideDisconnect When set to true, the charge point SHALL
unlock the cable on charge point side when the cable is unplugged at the EV.
This is not supported by IC/SC since it is plug type and no connector locker.
WebSocket Ping Interval Define the ping pong interval for WebSocket
protocol.
LocalAuthListEnabled Whether the Local Authorization List is enabled.
LocalAuthListMaxLength Maximum number of identifications that can be stored
in the Local Authorization List.
SendLocalListMaxLength Maximum number of identifications that can be send in
a single SendLocalList.req.
US Type Charger-80A
48
User Manual Rev 2.0
ReserveConnectorZeroSupported If this configuration key is present and set
to true: The charge point support reservations on connector 0.
ChargeProfileMaxStackLevel Max Stack Level of a Charging Profile. The number
defined also indicates the max allowed number of installed charging schedules
per Charging Profile purposes. ChargingScheduleAllowedChargingRateUnit A
list of supported quantities for use in a Charging Schedule. This value will
always be ‘Current’ for IC/SC. ChargingScheduleMaxPeriods Maximum number of
periods that may be defined per Charging Schedule.
ConnectorSwitch3to1PhaseSupported If defined and true, this charge point
supports switching from 3 to 1 phase during a charging session. This field is
ready only. MaxChargingProfilesInstalled Maximum number of charging profiles
installed at a time.
4.3.4 Communication settings
Clicking on the “Configuration” and then “Communication Settings” link will
bring up the following screen. Since the page is too long to display, we
separate it to couple screens. On this page you can set up the network
connection. To finish, click the “Apply” button.
US Type Charger-80A
49
User Manual Rev 2.0
Network Mode Specifies if enable the Local Proxy function. Available options
are Gateway, Client and Direct.
Direct: Use charge point as a single standalone device.
Gateway: Use charge point as a gateway charge point. Gateway connected to OCPP
1.6 Server via cellular, Ethernet or Wi-Fi and connected to other charge
points (called Client) via Wi-Fi or Ethernet and forms a local charge points
group. This group is also a LAN (Local Area Network).
Client: Use charge point as a client charge point. Client connected to Gateway
via WiFi/Ethernet. Client connected to OCPP1.6 Server through gateway charge
point (via cellular/Ethernet/Wi-Fi) and Gateway will dispatch incoming remote
command to proper client charge points (or Gateway itself).
US Type Charger-80A
50
User Manual Rev 2.0
Group Use External Gateway Gateway/Client mode use external gateway as a
local network group or not (use Gateway IC).
NOTE
A Gateway charge point can choose using Wi-Fi/Cellular/Ethernet to connect to
the internet by change ‘Group Use External Gateway’ setting. If set to Yes, a
Gateway will use Cellular/WiFi/Ethernet. When changed this setting, the
‘Connectivity’ option will automatically change as well.
All charge point in this Gateway/Client group must have the same ‘Group Use
External Gateway’ setting, i.e. all charge points must set this option to Yes
(including Gateway and Client) when we want to use an external Wi-Fi AP to
connect to internet. In this case, all charge points must also use the same
Wi-Fi settings (SSID, password) for the external Wi-Fi AP.
If you want to change web portal setting of Direct, Gateway and Client mode,
please refer to the separate address of web portal.
Direct / Gateway charge point : 10.10.0.1
Client charge point : 10.10.0.2
Connectivity Specifies whether the charge point should always be connected
to Internet using None, Auto, Wi-Fi, or Cellular. Default value is Auto.
[Cellular: for IC only] The rules for the options are defined as below:
1. None/Auto/Ethernet/Wi-Fi/Cellular for IC-Direct
2. Ethernet/Wi-Fi for IC-Gateway (Group Use External Gateway = Yes)
3. Wi-Fi/Cellular for IC-Gateway (Group Use External Gateway = No)
4. Wi-Fi for SC-Direct/SC Plus-Direct
5. Ethernet/Wi-Fi for IC-Client/SC Plus-Client
Client Connectivity Specifies whether the Gateway Device should always be
connected to Client Device using Ethernet or Wi-Fi.
Gateway Serial Number The serial number of the charge point which acts as a
Gateway.
US Type Charger-80A
51
User Manual Rev 2.0
Gateway LAN IP The IP of master in LAN. This value cannot be modified by
users. Gateway LAN Port (SOAP) The listen port for OCPP SOAP client server.
This value cannot be modified by users. Max Group Size The maximum number of
charge points allowed in a group/LAN is 20. This value cannot be modified by
users. Hide AP SSID Options for hiding SSID of this charge point or not. For
IC/SC this option is always off. There are four kinds of Gateway/Client
Network Topologies as below: Topology#1 Ethernet
All Gateway/Client EVSE in a group that can connect to the Internet via
Ethernet.
Setting up each EVSE according to the following settings
Setting
Gateway
Network Mode
Gateway
Group Use External Gateway
Yes
Client Client Yes
US Type Charger-80A
52
User Manual Rev 2.0
Connectivity
Ethernet
Ethernet
Client Connectivity
None
None
Gateway Serial Number
Gateway Serial Number Gateway Serial Number
Topology#2 Wi-Fi
All Gateway/Client EVSE in a group that can connect to the Internet via Wi-Fi.
Setting up each EVSE according to the following settings
Setting
Gateway
Client
Network Mode
Gateway
Client
Group Use External Gateway
Yes
Yes
Connectivity
Wi-Fi
Wi-Fi
Client Connectivity
None
None
Gateway Serial Number
Gateway Serial Number Gateway Serial Number
US Type Charger-80A
53
User Manual Rev 2.0
Topology#3 Wi-Fi/Cellular + Ethernet The Gateway EVSE in a group that can
connect to the Internet via Wi-Fi or Cellular. The Client EVSE in a group that
can connect to the Gateway EVSE via Ethernet.
Setting up each EVSE according to the following settings
Setting
Gateway
Client
Network Mode
Gateway
Client
Group Use External Gateway
No
No
Connectivity
Wi-Fi / Cellular
Ethernet
Client Connectivity
Ethernet
None
Gateway Serial Number
Gateway Serial Number Gateway Serial Number
US Type Charger-80A
54
User Manual Rev 2.0
Topology#4 Wi-Fi/Cellular + Wi-Fi The Gateway EVSE in a group that can connect
to the Internet via Wi-Fi or Cellular. The Client EVSE in a group that can
connect to the Gateway EVSE via Wi-Fi.
Setting up each EVSE according to the following settings
Setting
Gateway
Client
Network Mode
Gateway
Client
Group Use External Gateway
No
No
Connectivity
Wi-Fi / Cellular
Wi-Fi
Client Connectivity
Wi-Fi
None
Gateway Serial Number
Gateway Serial Number Gateway Serial Number
US Type Charger-80A
55
User Manual Rev 2.0
Active Device Status Active Device Current active network device. Possible
values are None, Ethernet, Wi-Fi or Cellular Active IP Address Current
active IP address. There will be value here only if connected to a network.
Active Netmask Current active netmask address. There will be value here only
if connected to a network. Active Gateway Current active gateway IP address.
There will be value here only if connected to a network and network provide
this data. Active Primary DNS Current active primary DNS IP address. There
will be value here only if connected to a network and network provide this
data. Active Secondary DNS Current active secondary DNS IP address. There
will be value here only if connected to a network and network provide this
data.
Ethernet Settings
Link Mode Configure the Ethernet port to use DHCP or Static IP. If you select Static IP from the dropdown menu, you need to enter values for IP Address, Netmask, and Default Gateway fields.
IP Address The IP address of the charge point. It’s modifiable if Link Mode is Static IP.
Netmask The subnet mask. It’s modifiable if Link Mode is Static IP.
Default Gateway The default gateway. It’s modifiable if Link Mode is Static IP.
US Type Charger-80A
56
User Manual Rev 2.0
Primary DNS The primary Domain Name Server (optional). Secondary DNS The
secondary Domain Name Server (optional). Ping URL Address of the host that
the charge point will ping for the Ethernet connection (optional).
Wi-Fi Settings SSID The SSID name of Wi-Fi Access Point. Press Scan button
to scan and receive current detectable Wi-Fi signal. Security The encryption
of Wi-Fi Access Point. Options are None, WEP, WPA-PSK, WPA2-PSK,
WPAPSK+WPA2-PSK and Auto. Password The password of Wi-Fi Access Point. Wi-Fi
MAC Address Display Wi-Fi device hardware MAC address. Wi-Fi Signal Strength
Display the wireless signal strength of Wi-Fi in dBm.
US Type Charger-80A
57
User Manual Rev 2.0
Cellular Settings [for IC only]
MNC The Mobile Network Code of cellular service provider. There will be no data here if no cellular signal.
ICCID The ICCID of the modem’s SIM card. There will be no data here if no SIM card inserted.
IMSI The IMSI of the modem’s SIM card. There will be no data here if no SIM card inserted.
IMEI The IMEI (International Mobile Equipment Identity) of the modem.
MEID The MEID (Mobile Equipment Identifier) of the modem.
Cellular APN This is the gateway for all cellular traffic. Contact your cellular operator for information about this. For AT&T and Verizon LTE service, just leave it blank since the apn name is built-in in the modem.
APN Username This is the user name your ISP has assigned to you (optional).
APN Password Password to log into the ISP network (optional).
Dial Number Phone number to dial for cellular network.
PIN Code PIN code for the modem’s SIM card (optional). 4 digit number.
Primary DNS The primary Domain Name Server (optional).
Secondary DNS The secondary Domain Name Server (optional).
US Type Charger-80A
58
Cellular Signal Strength The strength of cellular signal in dBm.
User Manual Rev 2.0
Local Load Management (LLM) Settings [for IC only]
Local load management is the process of balancing the supply of electricity on the network with the electrical load by adjusting or controlling the load of each charge point in a local group which is based on Gateway/Client architecture. The Gateway IC must be manually set the maximum current limitations so that it will dynamically adjust output current in each Client IC by charging policy.
When LLM function is on, all charge points will request for charging to Gateway, and Gateway will calculate the proper current limit and reply to each Client. Each charge point will only allow charging when received a current limit from Gateway. If disconnection occurred between a Client and Gateway, then the Client will use fallback value as the limitation.
Local Load Management Enable or disable Local Load Management function. This function can only be enabled in a Gateway or Client charge point.
HINT: If user changes “Network Mode” setting, then related settings will also change automatically such as “Connectivity”, “Local Load Management”. The default value is as follow:
Gateway LAN IP Gateway LAN Port Max Group Number Group Use External Gateway
Gateway Serial Number Connectivity
Local Load Management
Direct Not used Not used Not used Not used Not used Auto Disable, not changeable
Gateway Default value, not changeable Default value, not changeable Default value, not changeable Yes or No Not used Wi-Fi or Cellular
Client Not used Not used Not used Yes or No Used Wi-Fi, not changeable
Enable
Enable
US Type Charger-80A
59
User Manual Rev 2.0
Charging Policy The charging policy for LLM Gateway to decide the charging
current for each charge point. Valid options are:
- UD (default): Uniform Distribution. The maximum amperage is divided by total numbers of charging EV, i.e. each EV will use the same charging current.
- FIFS: First In First Serve.
Group ID An identity of the LLM group. A slave with different group identity will be rejected when attempting to connect to Gateway.
Group Size The total number of charge points in the LLM group. This value is only used in Gateway.
Max Amperage Grid Connection Total ampere of each phase allowed loading for the group of charge points at the same time. This value is only used in Gateway.
Fallback Current The fallback current when Client is not able to communicate with Gateway. Gateway will overwrite fallback current in Client with its own value when Client connected to Gateway.
Note
Any option followed by a star mark (*) means the setting need to reboot to take effect. When these value changed and applied the web portal will display a reminder message box for rebooting the charge point.
US Type Charger-80A
60
Maintenance
This page includes some maintenance functions.
User Manual Rev 2.0
4.4.1 Reboot
Command
Reboot: To restart the charge point.
Reset to MFG default: To reset to the factory default settings.
Charging Profile Data
HINT: Charging Profile is defined in OCPP 1.6 specification for smart
charging. A charging profile consists of a charging schedule, which is
basically a list of time intervals with their maximum charge power or current,
and some values to specify the time period and recurrence of the schedule.
Show All Charging Profile Data: To show the list of Charging Profiles. There
will be a display window. The data display here is a RAW data, usually for
diagnostic use.
US Type Charger-80A
61
User Manual Rev 2.0
Clear All Charging Profile Data: To clear all Charging Profile data.
Local Authorization
HINT: Local authorization is defined in OCPP 1.6 specification. There are two
local list: Local Authorization List and Authorization Cache List. The Local
Authorization List is a list of identifiers that can be synchronized with the
Central System. An Authorization Cache autonomously maintains a record of
previously presented identifiers that have been successfully authorized by the
Central System.
Show Local Authorization List: To show the list of Local Authorization. Each
line of the list shown below indicates a RFID card info. The syntax is
CARD_IDTAG|EXPIRY_DATE|PARENT_CARD_IDTAG|CARD_STATUS
US Type Charger-80A
62
User Manual Rev 2.0
Clear Local Authorization List: To clear the list of Local Authorization.
Upload List: Upload a csv file which including card info to Local
Authorization List. A csv file is a plain text file which each line represent
a RFID card info. The format of a card info is as follow:
CARD_IDTAG,EXPIRY_DATE,PARENT_CARD_IDTAG,CARD_STATUS CARD_IDTAG: 8 ~ 20
character RFID card ID tag combined with alphabet or numbers. EXPIRY_DATE: The
date at which idTag should be removed from the Authorization Cache. Format is
YYYY-MM-DDThh:mm:ss.ttt which indicates a date in AD. Example:
2019-12-31T16:00:00.000 PARENT_CARD_IDTAG: the parent-identifier of the card.
The format is same as CARD_IDTAG. CARD_STATUS: This contains whether the idTag
has been accepted or not by the Central System. Valid options are Accepted,
Blocked, Expired or Invalid. This string is case sensitive. Sample data:
0123456789ABCD,2019-12-31T16:00:00.000,PARENTID,Accepted Show Authorization
Cache List: To show the list of Authorization Cache. Each line of the list
shown below indicates a cached RFID card info. The syntax is
CARD_IDTAG|EXPIRY_DATE|PARENT_CARD_IDTAG|CARD_STATUS|CACHED_DATE
US Type Charger-80A
63
User Manual Rev 2.0
Clear Authorization Cache List: To clear the list of Authorization Cache.
Upload Cache: Upload a csv file which including cached card info to
Authorization Cache List.
A csv file is a plain text file which each line represent a cached RFID card
info. The format of a cached card info is as follow:
CARD_IDTAG,EXPIRY_DATE,PARENT_CARD_IDTAG,CARD_STATUS,CACHED_DATE
CARD_IDTAG: 8 ~ 20 character RFID card ID tag combined with alphabet or
numbers.
EXPIRY_DATE: The date at which idTag should be removed from the Authorization
Cache. Format is YYYY-MM-DDThh:mm:ss.ttt which indicates a date in AD.
Example: 2019-12-31T16:00:00.000
PARENT_CARD_IDTAG: the parent-identifier of the card. The format is same as
CARD_IDTAG.
CARD_STATUS: This contains whether the idTag has been accepted or not by the
Central System. Valid options are Accepted, Blocked, Expired or Invalid. This
string is case sensitive.
CACHED_DATE: The date that the idTag be cached. Format is identical to
EXPIRY_DATE.
Sample data:
0123456789ABCD,2019-12-31T16:00:00.000,PARENTID,Accepted,2018-3-22T16:00:00
4.4.2 Firmware upgrade
To upgrade the firmware of the charge point, you need to download the upgrade
image file to your local hard disk, and then click the “Choose File” button to
locate the firmware file on your computer. Once you have selected the new
firmware file, click the “Upload” button to start the upgrade process. After s
successful upgrade, the web portal will be log out and charge point will
reboot.
Although the web portal does not forbid upload firmware to previous version,
but since the design of firmware upgrade file is including all backward
modifications, downgrading firmware may cause unpredicted problem and is not
recommended.
US Type Charger-80A
64
User Manual Rev 2.0
EVSE Status
To check the specific information of EVSE, you can click the corresponding
buttons:
Show Control Unit State: To display the information of the control unit of
charge point. Mostly the function regarding to charging and safety.
Show Network Unit State: To display the information of the network board of
charge point. Mostly the function regarding to network connection and remote
management.
Show Net Profile State: To display the information of the network connectivity
and settings of charge point.
Show Device State: To display the information of the device service/connection
between charge point and OCPP server/network connectivity.
US Type Charger-80A
65
User Manual Rev 2.0
LLM Status (IC support only)
4.6.1 LLM information
This page shows the Local Load Management information of the charge point. For
more LLM description, please refer to section 4.6.3. Network Operation Mode:
Indicates the charge point is in Direct mode, a Gateway or a Client. LLM Mode:
Indicates Local Load Management function is enabled or disabled. Network
Status: Indicates if the charge point is online or not. Gateway Status:
Indicates if the charge point is connected to the Gateway if it’s a Client.
For Direct and Gateway, it always shows “Connected to Gateway”. Network Active
Device: Indicates the Network connected via which device. It could be Offline,
Wi-Fi or Cellular. Local Load Management Status: Display connected charge
points, total charge points, Group ID of the LLM group as well as a full table
of detail information each charge point if this charge point is Gateway.
US Type Charger-80A
66
User Manual Rev 2.0
4.6.2 Gateway/Client group table
If the charge point is Gateway, the following LLM Group Table is present.
Index: The order of the charge point. The index is first connected to Gateway
first showed. Serial Number: The serial number (Charge Point Identity) of each
charge point. IP: The private local IP address in LLM group of each charge
point. Wire Type: The power source wire type of each charge point. Request:
The requested current of each charge point PWM: The PWM (charger allowed)
current of each charge point Phase 1, Phase 2, Phase 3: The real current
loaded by the vehicles of each charge point. For Intelligent Charger-32A only
Phase 1 has current.
US Type Charger-80A
67
User Manual Rev 2.0
4.6.3 Operation mode
There are two different operation modes, Distribution mode and Priority mode.
Each time when a new coming car is plugged-in and start charging. The LLM
gateway will re-calculate the proper ampere for each charging station.
Base on the different mode, the algorithm is different.
Distribution mode (Uniform Distribution) The available current is divided
equally amongst all available charging stations.
Example 1 In this example, there are three (32A) charging stations in the LLM group. Setting up each charging stations according to the following settings:
Setting
Gateway
Client
Local Load Management
Enable
Enable
Charging Policy
Uniform Distribution
Not used
Group ID
LLM-Group-1
LLM-Group-1
(Same as Gateway)
Group Size
3
Not used
Max Amperage Grid Connection
60
Not used
Fallback Current
10
10
(Same as Gateway)
With one connected vehicle, the charging current is 32A.
US Type Charger-80A
68
User Manual Rev 2.0
With two connected vehicles, the charging currents are evenly reduced to 30A.
With three connected vehicles, the charging currents are further reduced to
20A.
Example 2 In this example, there are two (32A) charging stations and one (16A) charging station in the LLM group. Setting up each charging stations according to the following settings:
US Type Charger-80A
69
Setting
Local Load Management Charging Policy Group ID
Group Size Max Amperage Grid Connection Fallback Current
Gateway Enable Uniform Distribution LLM-Group-1
3 60
10
User Manual Rev 2.0
Client Enable Not used LLM-Group-1 (Same as Gateway) Not used Not used
10 (Same as Gateway)
With one connected vehicle, the charging current is 32A.
With two connected vehicles, the charging currents are evenly reduced to 30A.
With three connected vehicles, the charging currents are further reduced to 24A for 32A charging stations and the charging current is 12A for 16A charging station.
US Type Charger-80A
70
User Manual Rev 2.0
Example 3 In this example, there are five (32A) charging stations in the LLM group and two of the charging stations are offline. Setting up each charging stations according to the following settings:
Setting
Local Load Management Charging Policy Group ID
Gateway Enable Uniform Distribution LLM-Group-1
Group Size
5
Max Amperage Grid Connection
80
Fallback Current
10
Client Enable Not used LLM-Group-1 (Same as Gateway) Not used Not used
10 (Same as Gateway)
With one connected vehicle, the charging current is 32A. (Reserve 20A for offline charging stations)
US Type Charger-80A
71
User Manual Rev 2.0
With two connected vehicles, the charging currents are evenly reduced to 30A.
(Reserve 20A for offline charging stations)
With three connected vehicles, the charging currents are further reduced to
20A. (Reserve 20A for offline charging stations)
Priority mode (First Come Fist Serve) The available current is NOT divided equally amongst all available charging stations. The first vehicle connected would be allocated as much as possible. If any current capacity is left, then the remainder would be given to the other charging stations.
US Type Charger-80A
72
User Manual Rev 2.0
Example 1 In this example, there are three (32A) charging stations in the LLM group. Setting up each charging stations according to the following settings:
Setting
Gateway
Client
Local Load Management
Enable
Enable
Charging Policy
First In First Serve
Not used
Group ID
LLM-Group-1
LLM-Group-1
(Same as Gateway)
Group Size
3
Not used
Max Amperage Grid Connection
60
Not used
Fallback Current
10
10
(Same as Gateway)
The first vehicle connected would receive 32A.
The second vehicle would receive 28A.
US Type Charger-80A
73
The third vehicle is NOT able to receive current.
User Manual Rev 2.0
When the first vehicle left, the second vehicle would receive 32A, and the third vehicle would receive 28A.
Example 2 In this example, there are five (32A) charging stations in the LLM group and two of the charging stations are offline. Setting up each charging stations according to the following settings:
Setting
Gateway
Client
Local Load Management
Enable
Enable
Charging Policy
First In First Serve
Not used
Group ID
LLM-Group-1
LLM-Group-1
(Same as Gateway)
Group Size
5
Not used
Max Amperage Grid Connection
100
Not used
US Type Charger-80A
74
Fallback Current
User Manual Rev 2.0
10
10
(Same as Gateway)
The first vehicle connected would receive 32A. (Reserve 20A for offline charging stations)
The second vehicle would receive 32A. (Reserve 20A for offline charging stations) The second vehicle would receive 16A. (Reserve 20A for offline charging stations)
US Type Charger-80A
75
User Manual Rev 2.0
Security
4.7.1 Change password
To change password, first choose user you want to change password. There are
two default users admin and maintain. Only admin user can access Security
Page. Enter old password and new password then press “Apply” button to change
password of the user. To reset password of all users, press “Reset password of
all users” button.
US Type Charger-80A
76
5 Operations
User Manual Rev 2.0
Charging status indicators
LED Indicator
Table 5-1 Charging status indicators
Description
Not illuminated
Power Off
Definition
Green Steady Green Flashing
Ready
Flashing green (Fast): Authorized, wait for EV Connect Flashing green (Slow):
Suspend (Occupying)
Blue Flashing
Flashing blue (Slow): Charging
Red Steady
Unrecoverable Fault
Red Flashing
Recoverable Fault
Purple Steady
Reserved (from OCPP Service)
Yellow Flashing
Booting / Firmware Upgrading / Out of Service
US Type Charger-80A
77
User Manual Rev 2.0
Authorization (for IC only)
Before the owner of an electric vehicle can start or stop charging, the Charge
Point has to authorize the operation.
5.2.1 Online Authorization
Description: · Generally, before the owner of an electric vehicle can start or
stop charging, the EVSE has to
authorize the operation. The EVSE SHALL only supply energy after
authorization.
Figure 5-1 On-line Authorization
5.2.2 Local Authorization
Description: · Synchronized with the Central System when EVSE is Online. · To
improve the experience for users, the EVSE MAY support local authorization
when EVSE is
offline, and faster authorization response time when communication between
Charge Point and Central System is slow.
Figure 5-2 Local Authorization
US Type Charger-80A
78
Charging an Electric Vehicle (EV)
Choices of start charging are as below:
5.3.1 Plug and Charge
1. Insert the charging plug into the EV 2. Charging session started
User Manual Rev 2.0
Figure 5-3 Connect the charging plug to the EV
5.3.2 RFID card (for IC only)
1. Insert the charging plug into the EV 2. Swipe card 3. Waiting for
authorizing 4. Charging session start
Stop charging
1. Unplug any time (disconnect the charging plug from EV to stop charging
session) 2. Session ended (please return the connector to the holster)
5.4.1 Interrupt charging
Please refer to STOP CHARGING section for more information.
US Type Charger-80A
79
User Manual Rev 2.0
5.4.2 Auto restart
When a charging session is interrupted due to a temporary error condition, the
charge point will automatically restart charging when the cause of the
temporary error condition returns to normal. Status indicator lights remain
flashing RED until the error condition is resolved.
· Temporary error conditions include: Over Current, Over Voltage, Under
Voltage, and Over Temperature.
· For Over Current conditions: The charging session will be stop while OC
occurs. After recovery from OC for 30 seconds, the charge point will
automatically restart charging for three times.
· When charging session stopped due to CCID trip, the charge point will try to
restart after 15 minutes for 3 times.
5.4.3 Power outage recovery
When power resumes after an outage, the charge point restarts automatically
with a delay ranging from 120 to 720 seconds. The delay is designed to avoid
impacting the utility grid when multiple charge points are in the same area
attempting to resume charging simultaneously.
General care
The exterior of the charge point is designed to be waterproof and dust proof.
To ensure proper maintenance of the charge point, follow these guidelines:
· Despite the water resistance of the enclosure, when cleaning it is preferred
to not direct streams of water at the unit. Clean with a soft, damp cloth.
· Make sure the charging plug is put back in the holster after charging to
avoid damage. · Ensure the power cable is stored on the charge point after use
to avoid damage. · If the power cable or the charging plug is damaged, please
contact Customer Support.
Customer support
Please contact your reseller directly for technical support.
US Type Charger-80A
80
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>