INSTALLATION AND MAINTENANCE INSTRUCTIONS
ALUMINIUM FILTER REGULATOR
SIZE: 3/4” & 1”
SERIES
643
These operating instructions are delivered with each product.
Malfunctions, damage or injury may occur if these instructions are not
followed.
Description
Series 643 Air Filter Regulators are designed for use in potentially explosive
atmospheres caused by gases, vapors, mists and/or dusts as per ATEX Directive
2014/34/EU and standards EN ISO 80079-36. . UKSI Regulation 2016: 1107 (as
amended by UKSI 2019:696)- Annex 3A, Part 1 after ATEX directive and BS EN ISO
80079-36 (2016)
Classification (Zone 1 and 21): II 2 G Ex h IIC T5 Gb, II 2 D Ex h IIIC T5 Db
The Classification temperature depends on the ambient temperature. These
regulators are made of external metal parts & internal with plastic/metal
parts.
Startup and maintenance are to be performed as detailed below.
General
This component is not a safety accessory. It is intended only for the
compliant use either as an individual component or incorporated in an
apparatus, machinery and installations. Filter Regulators are designed to be
operated in accordance with the limits specified in the nameplate or as
specified in this document. All applicable directives, legislations, orders
and standards, as amended from time to time, as well as state-of-the-art
practices and procedures must be observed for intended scope of application of
the product. Where applicable take all appropriate measure to ensure the
requirements are met. This device complies with the essential safety
requirements of the EU PED 2014/68/EU. Declaration of conformity is available
on request.
All assembly, operation, use and maintenance must be performed by qualified, authorized personnel. Personnel working with the components must be familiar with the applicable safety and regulations relating to the components, apparatus and machinery installations. In case of problems, please contact ASCO or one of its authorized representatives in your region.
General Operating Specifications
Fluid: Instrument air
Ambient Temperature: For manual drain: the temperature range should be within
-40º C to + 90º C (-40ºF to +194º F); For Auto drain: the range should be
within +1°C to + 80°C (34°F to +176°F).
Inlet Pressure: Do not exceed the maximum operating pressure 20 bar(290psi)
for manual drain FR, 17bar(247psi) for auto drain FR.
Installation
Check the preliminary storage conditions required for the component. They must
be in accordance to the product’s specifications.
Carefully remove the Filter Regulator from the packaging.
Power off and depressurize the apparatus, machinery or installation designed
to receive the FR.
Install the FR near where the air is to be used.
Install ASCO pressure gauge comes accessory on the gauge port. & Do Not modify
the device.
Make sure that the fluid is compatible with the materials it contacts.
Operator or user must ensure that the gas group corresponds to the product’s
classification.
Check Nameplate for correct catalog number, pressure, temperature and service.
Never apply incompatible fluids or exceed pressure rating of the regulator.
The installer must install the air filter regulator at the user’s location in
accordance with the requirements specified in Directive 99/92/EC.
Positioning
For optimum life and performance, the FR should be mounted vertically
upright (Max. Inclination 5°).
Piping
Connect piping to valve according to markings on FR body. Apply pipe compound
sparingly to male pipe threads only. If applied to FR threads, the compound
may enter the FR and cause functional difficulty. Avoid pipe strain by
properly supporting and aligning piping. When tightening the pipe, do not use
the FR as a lever. Locate wrenches applied to piping as close as possible to
connection point.
Direct Frontal mounting or mounting with brackets possible.
Maintenance
NOTE: Ensure the air supply is completely stopped. It is not necessary to removethe FR from the pipeline for repairs.
Cleaning
All FRs should be cleaned periodically. The time between cleanings will vary
depending on the medium and service conditions. The most common part that
requires cleaning is the filter element.
Use running water for regular cleaning or a mild detergent for cleaning the
filter element. Do not use diluted acids, strong detergents or corrosive
chemicals.
For auto drain version clean the filter ring periodically.
Causes of Improper Operation
Incorrect pressure: Check upstream pressure. Pressure to FR must be within
range specified on nameplate.
Excessive Leakage: Disassemble FR and clean all parts. If parts are worn or
damaged, install a complete ASCO Spare Parts kit.
Manual drain operation:
Hold the knurling face of drain with fingers & rotate it to the anti-clockwise
direction looking from top to unscrew the manual drain to purge out the water
that accumulated in the bowl. After draining out, screw the manual drain back
to its original position & ensure proper working of AFR.
Earthing:
The earth is connected to the unit or to the combination of conditioning units
by the downstream and upstream use of metal pipes connected to the earth. If
the pipes are non-conductive, earth connection should be performed by the
assembly and/or fixing devices adapted to the ATEX products.
Automatic draining:
Auto drain provides hassle free draining of equipment which purge out the
water accumulated in the bowl automatically. It also provides manual drain
feature integrated with automatic drain. Anti-clockwise to drain & clockwise
to close drain when looking from top view
FR DISASSEMBLY
- Disassemble FR in an orderly fashion using exploded views for identification and placement of parts. Refer to figure 1.
- Remove bowl from the body (as shown in fig. 17) and the remove bowl seal
- Unscrew the filter assembly by hand itself
- Carefully unscrew the bowl baffle in filter assembly and remove filter element for cleaning
- For normal maintenance(cleaning) it is not necessary to remove the poppet assembly. However, if poppet assembly removal is required, just pull it out of the body.
- Remove the manual drain/auto drain from the bowl
- Remove the bonnet from the body by unscrewing the M6 fasteners and remove top spring and diaphragm assembly.
- All parts are now accessible to clean or replacement. If parts are worn or damaged, install a complete ASCO Spare Parts Kit.
– Service Notice –
When installing a new ASCO spare parts kit, the parts supplied are shown in
Figure. A. The parts supplied are new and a direct replacement for the present
parts provided all news parts are installed.
CAUTION: To ensure proper valve operation, install all parts supplied in
ASCO Spare Parts Kit. Do not mix old and new parts.
FR REASSEMBLY
- Lubricate all gaskets with CERAN LT lubricant or an equivalent low temperature silicone fluid.
- Add a layer of NEVERSEEZ – 160S on all screw threads
- If removed, install poppet assembly in body. Apply a small amount of NEVERSEEZ – 160S to filter sub assembly threads. Hand tight the assembly as far as possible. No special tool is required to provide torque
- Install diaphragm assembly, springs, spring disc and bonnet on top. Secure the bonnet on top of the body by tightening the M6 fasteners
- Replace manual drain/auto drain on bowl and assemble bowl on bottom side of the body (as shown in fig. 18)
- Install FR in vertical position.
EXPLODED VIEW
MOUNTING
|
---|---
FIG. 5: ASSEMBLED VIEW| FIG. 6: DISASSEMBLED VIEW
GAUGES
TAMPER PROOF
FINAL ASSEMBLY (FIG 10)
T- HANDLE
DISASSEMBLY | ASSEMBLY |
---|
|
DRAINS| | METAL MANUAL DRAIN
(Brass/stainless steel)| • TEMPERATURE: -40°C … +90°C
• Min. INLET PESSURE (P1 Min.): 0 Bar
• Max. INLET PRESSURE (P1 Max.): 20 Bar
---|---|---|---
| Automatic
Drain NC/NO| • TEMPERATURE: +1°C … +80°C
• Min. INLET PESSURE (P1 Min.): 0.5 to 1.0 Bar
• Max. INLET PRESSURE (P1 Max.): 17 Bar
FIL TERS| PE| | |
---|---|---|---|---
Filtration| 5 µm| 25 µm| 40 µm
Colour| White| Yellow| Green
ITEMS | N.m | Inch.pounds |
---|---|---|
J | 1.1±0.2 | 10±2 |
K | 0.45±0.1 | 4±1 |
643 SERIES
ATEX
USABLE IN ATEX ZONES
SCREW (1), BOWL (2), BODY (3), BONNET (4), DRAIN (5), AND BOLT (6) ALL ARE METAL PARTS
This category of products does not fall within the scope of the ATEX 2014/34 / EU directive: the risk analysis according to the EN ISO 8007936 standard has shown that no potential source of ignition specific to the products are effective. These product categories are named simple mechanical products and do not include moving parts. These products can be used in specific explosion zones 1 and 21 in compliance with our installation instructions:
-
List of affected components
- Mounting components
- Assembly and connection components
- Mechanical accessories
- Filter
These conditioning units of compressed air and their accessories are capable for use in explosive atmospheres in the form of gas, steam, mists and dust.
SPECIAL CONDITIONS FOR SAFE USAGE:
Risk from electrostatic charges
Prevent electrostatic charging of external insulating surfaces by using the
appropriate installation and cleaning measures. To clean external insulating
surfaces, use a damp cloth.
Connect the conditioning units to the earth.
When combined with other conditioning units, ensure that all metallic and
conductive parts are always interconnected and linked to the earth to avoid
significant electrostatic charges being created.
The earth is connected to the unit or to the combination of conditioning units
by the downstream and upstream use of metal pipes connected to the earth. If
the pipes are non-conductive, earth connection should be performed by the
assembly and/or fixing devices adapted to the ATEX products.
Installation, commissioning and servicing and maintenance
These operations may only be carried out by authorised personnel and in
accordance with the usage instructions.
Only carry out maintenance in zones where there is no explosive atmosphere.
If during maintenance it is established that wearing and spare parts need
exchanging, contact an ASCO Numatics or AVENTICS reseller.
Any modification of the product with parts not supplied by the manufacturer
will invalidate the certification.
Filter equipped with a metallic bowl: (see fig. B)
When replacing a filter element saturated by the filter, proceed as described
below:
- Loosen the screw (1)
- Remove the bowl (2) from the body (3)
- Remove the filter element and replace with a new one
- assemble the bowl (2)
- Tighten the screw (1) in the body (3) up to the contact of the bowl and screw one quarter to a half turn extra in order to ensure ground continuity.
ASCO NUMATICS INDIA Pvt Ltd.,
Plot No P45, 8th Avenue, Mahindra world city
Chengalpattu, Kanchipuram
Tamil nadu- 603002, India
FORM NO: 551463-001
REV: AC
ECN: 326819
PAGE NO: 12