Distance (X) is a recommended position from front of hangar tube to front of the first collar.
INSTRUCTION
(Y) is the distance between collars.
STEPS
Step 1 – Set distance/Attach collars
- Remove bolts (x2per) from the collar (x4)
- Split collar
- Measure distance as stated on Page1 (Mark position on base if desired)
- Place collar halves on either side of the leg
- Replace bolts loosely
Step 2 – Attach interface
- Unscrew adjuster screws so adjusters can move in and out of the Interface frame freely
- Slide adjuster out to suit position of collars
- Place interface over all collars
Step 3 – Secure Interface
- Place pins (x8) through the holes in adjusters and collar to secure frame
- Pins are all inserted from the front of the base. (see below)
- Secure collar bolts in the following order;
- Make sure bolts face outward (see below)
- Tighten top bolt until hand tight
- Repeat for bottom bolt
- Tighten top bolt with 5mm Allen key until secure
- Repeat for bottom bolt
- Tighten adjuster screws using 5mm Allen key until tight.
Work Instruction Ref: LWI-194-002
Assy Dwg : 194-600/194-700/194-800 Issue: 001