PowerXchanger Step-Up Series Double Conversion AC Power Converter Instruction Manual
- June 14, 2024
- POWERXCHANGER
Table of Contents
Operating Manual
Double Conversion AC Power Converter
Step-Up Series
22050UX-1000
22050UX-1500
22050UX-2000
22050UX-3000
Step-Up Series Double Conversion AC Power Converter
Input Range: | 100 Vac ~ 285 Vac |
---|---|
Input Frequency: | 60Hz |
Output Range: | 200V-220V-230V-240V Selectable |
Output Frequency: | 50 Hz |
Read this manual before using PowerXchanger®. Failure to follow the
instructions and safety precautions in this manual can result in serious
injury or death.
Keep this manual in a safe location for future reference.
CAUTION :
- The Converter connection instructions and operation described in the manual must be followed in the indicated order.
- Converter must be connected to a nearby wall outlet that is easily accessible. The Converter can be disconnected from the AC-power source by removing the power cord.
- DO NOT install the Converter near liquids or in an excessively damp environment.
- DO NOT let a foreign body penetrate inside the Converter.
- DO NOT block the ventilation grates of the Converter.
- DO NOT expose the Converter to direct sunlight or source of heat.
- If the Converter must be stored prior to installation, storage must be in a dry place.
- The admissible storage temperature range is -15℃ to +55℃.
Special Symbols
The following are examples of symbols used on the Converter to alert you the
important information.
CAUTION
Risk of Electric Shock Do Not Open Cover
CAUTION To reduce the risk of electric shock, Do not remove cover (or
back) No user-serviceable parts inside Refer servcing to the factory
RISK OF ELECTRIC SHOCK –
Indicates that a risk of electric shock is present, and the associated warning
should be observed
CAUTION; REFER TO OPERATOR’S MANUAL –
Refer to your operator’s manual for additional information, such as important
operating and maintenance.
SAFETY EARTHING TERMINAL –
Indicates the primary safety ground.
OVERVIEW AND FEATURES
This series is a double conversion Power Converter which produces stable pure
sine wave voltage and frequency output (O/P). With the Converter, you can
protect your equipment from most of the power problems, including power sags,
power surges, brownouts, and line noise, etc. With the common neutral
topology, the Converter provides internal connection from AC I/P neutral to AC
O/P neutral; thus, it does not need to use an isolation transformer to provide
0 volt from AC I/P neutral to O/P neutral. This feature will reduce the
interference when connected to communication or video systems.
With outstanding performance and reliability, the unique benefits of the
Converter include the following:
- Common Neutral, Double Conversion Topology (O/P Neutral to I/P Neutral is 0 Volts Normally)
- Wide Range Input Window and Input Power Factor Correction
- Low Noise Smart Cooling Fan Design
- High Efficiency, New Full-bridge Converter Design
- Full Function LCD Display
- Automatic Restart of Loads After Overload Shutdown
- AC Input Generator Compatible
PRESENTATION
2.1 Front Panel
The following shows the functions of the LCD Display:
- Data Select
- Main Control Button
- LCD Display
2.2 Rear Panels
UX-1000, UX-1500, UX-2000, UX-3000
- Circuit Breaker
- Power Cord
- Cooling Fan
INSTALLATION
- SAVE THESE INSTRUCTION. Please follow these instructions for installation and maintenance of the Converter. Please read all instructions before operating the equipment and save this manual for future reference.
- Increased ambient temperature will shorten the life of the Converter, keep the Converter away from heating elements.
- If ambient temperature is over 40℃, the load level will be reduced.
- The ambient temperature should be between 0°C and 40°C to ensure optimal operation, over this range will reduce the average output power due to thermal de-rating.
OPERATION
4.1 After installation with normal city power, the Converter will turn on
automatically. Confirm the output voltage and frequency with the LCD display
by pressing the up/down select button.
4.2 Converter OFF: Pushing the main control button for 3 seconds will
turn off the output voltage of the Converter. The CPU will be in “OFF” (idle)
mode when the LCD shows “OFF”
4.3 In Idle Mode, the Converter will turn on again when the main control
button is pushed for 1 second. Please disconnect the input power if you want
to shut down the Converter completely. 4.4 Change the Output Voltage and
Frequency: Push the two selection buttons, △ and ▽, at the same time for 3
seconds until the LCD display begins to blink. 4.4.1 To Change the Converter
O/P Frequency
When the frequency value is blinking, push any selection button, △ or ▽, for 1
second to change the frequency setting. The setting will keep changing every 2
seconds if you keep pushing the button. Push the two selection buttons at the
same time to access the next setting customization option. To confirm the
setting, leave the LCD Display blinking without pushing any buttons for 30
seconds. Once it stops blinking the new setting will take
effect. 4.4.2 To Change
the Converters Rated Voltage
When the voltage value is blinking, push any selection button for 1 second to
change the rated voltage. Keep pushing the button until the required voltage
is blinking. Then, push the two select buttons at the same time to confirm, or
leave the LCD blinking for 30 seconds to end.
INDICATION AND CONTROL
5.1 LCD Display
The Converters LCD display shows the Input Voltage, Output Voltage, Output
Frequency, Output Load Level, and Temperature.
5.2 Thermal Protection
If the Converter detects that it is starting to overheat, it will perform a
sequence of 32 beeps every two seconds. The LCD Display will also show a high
temperature symbol when the inside of the unit is too hot.
If the Converter continues to overheat, it will eventually turn itself off to
protect itself from damage. Once the Converter has cooled off sufficiently, it
will automatically restart.
5.3 Output Short Circuit Protection
If the Converter detects that the output voltage is too low for at least
250ms, and the output is short circuited or extremely overloaded, the
Converter will shut down and attempt to restart after 30 seconds.
The Converter will continue attempts to restart up to 30 times. If the
overload is still present after 30 attempts, the Converter shuts down and
latches off. To restore the Converter’s functionality, remove the cause of the
output short circuit or extreme overload, then push the main control button
for 1 second to turn the Converter on again.
5.4 Output Overload Alarm
The Converter can accept up to 129% of a load (See Specification Sheet for
each Model’s Rating on Page 12) before a continuous alarm begins to sound. If
the output current drawn by the load exceeds the Converter’s over current
alarm threshold, the CPU timer will start to countdown. If the overload
continues for more than one minute an audible alarm will sound as long as the
overload is present. If the overload alarm continues for more than one minute,
the Converter will turn off the output. After a 30 second delay, the
Converters output will restart.
5.5 Output Overload Protection
If the output of the Converter is loaded to more than its output overload
protection threshold for more than two seconds, it will turn off its output,
sound an audible alarm, and the LCD will display an overload symbol. After a
30 second delay, the Converter will turn on the output again. If the overload
is no longer present, the audible alarm will stop, and the output will operate
normally. If the overload is still present, the Converter will once again turn
off the output and wait 30 seconds before attempting to start again.
SPECIFICATIONS
Output
Capacity| 1000VA/900W| 1500VA/1350W| 2000VA/1800W| 3000VA/2700W*
Output Voltage| 200V/220V/230V/240V Selectable
Voltage Waveform| Sine Wave
Crest Factor| 3 :1
Output Frequency (Sync to Mains)| 50/60Hz (Selectable from LCD Function
Button)
Output Frequency (Not Sync to Mains)| 50±0.01Hz or 60±0.01Hz
Regulation| ±2% of Selected Output Voltage (Adjustable by Using the Setting
Software)
Output Current
200 V ~ 240 V| 4.2 Amp| 6.3 Amp| 8.4 Amp| 12.5 Amp
Output Peak Current
(<250mS)| 13 Amp| 20 Amp| 27Amp| 37 Amp
Overload Protection| 100%~129% for 60 seconds, then audible alarm; audible
alarm sounds for 60 seconds before shutting down >130%, alarm will go off for
2 seconds and then shutting down
Harmonic Distortion| <3% (At Full Resistive Load)
Efficiency| Up to 90%
Input
Voltage Range| 100V~285Vac| 240 volts
Range: 180V~285V
Requires a Dedicated
240-Volt Power
Frequency Range| 45~70Hz
Input Current| 10 Amp| 15 Amp| 20 Amp| 20 Amp
Wall-Outlet Type Required| NEMA 5-15 R (15 Amps)| NEMA 5-20 R (20 Amps)|
NEMA 5-20 R(20 Amps)| NEMA 6-20 R (20 Amps)
Power Factor| ≧0.98
Surge Current| <100A, 3mS
Communications & Management
Control panel| LCD
Audible alarm| Overload Alarm, Short-Circuit Alarm, and Thermal Alarm
Environmental and Safety
Operating Temp.| Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Transit/storage Temp.| -15℃ to 55℃ (5℉ to 131℉)
Relative Humidity| 5 – 95% Non-Condensing
Operating Altitude| 0 ~ 3000 meters
Audible Noise| ≦45 dBA (At 1 Meter From Surface of Unit)
Safety Markings| | BSMI| | CE
Quality Control System| ISO9001
Physical
Unit Dimensions D x H x W| | UX-1K:| 38×22×18cm| 15×9×7in
| UX-1.5K:| 45×22×18cm| 18×9×7in
| UX-2K:| 51×22×18cm| 20×9×7in
| UX-3K:| 51×22×18cm| 20×9×7in
Unit Weight| | UX-1K:| 6.5kg| 14 lbs
| UX-1.5K:| 7kg| 15.5 lbs
| UX-2K:| 8kg| 17.6 lbs
| UX-3K:| 8.5kg| 18.7 lbs
Shipping Dimensions D x H x W; Weight| | UX-1K:| 51×32×35cm; 7.2kgs|
20×12.5×14in; 16lbs
| UX-1.5K:| 56×32×35cm; 8.8kgs| 22×12.5×14in; 19.50lbs
| UX-2K:| 64×32×35cm; 10.6kgs| 25×12.5×14in; 23.50lbs
| UX-3K:| 64×32×35cm 10.6kg| 25×12.5×14in; 23.5lbs
PS.“*” Please refer to the input range for the condition of output rated capacity.
Step-Up Voltage and Frequency Converter (UX Series) 1000VA/ 1500VA / 2000VA / 3000VA UX-1K / UX-1.5K / UX-2K / UX-3K
LIMITED WARRANTY
Adaptive Frequency Inc. warrants for two years from the date of shipment, the
product is free of manufacturing defects and conforms to Adaptive’s product
specifications in force as of the date of manufacture of the product shipped.
This warranty does not apply to accidental damage, shipping damage, misuse,
abnormal line or source voltage, abnormal conditions of operation beyond the
parameters specified in this product manual;
- Products which have been opened, misused, tampered with internally and or deliberately modified will void the warranty;
- The failure to return a unit claimed to be defective in its original packaging will void the warranty;
- Upon receiving the properly returned defective unit, Adaptive will verify that the unit is defective and upon verification will ship a replacement unit at Adaptive’s cost and reimburse purchaser’s shipping charges for return of the defective unit.
- Prior to shipping the defective unit, purchaser shall contact Adaptive at www.PowerXchanger.com/Returns to complete a return authorization form and so that Adaptive can assist in making the shipping arrangements;
- Any claim under this warranty requires that purchaser send with the return shipment, a proof of purchase, the unit serial number and the completed return authorization form;
- If it is determined that this warranty has been voided for any of the above reasons, the unit will be returned to the sender;
Adaptive shall only be liable under this warranty if the product has been used
in accordance with Adaptive’s instructions, in force on the date of purchase.
The purchaser must examine the product when received and promptly notify
Adaptive in writing of any non-conformity before the product is used and no
later than 30 days after such non-conformity is first discovered. If Adaptive,
in its sole discretion, determines that the product has breached the above
warranty, it will, at its sole discretion: replace the nonconforming product;
refund the purchase price; or issue a credit in the amount of the purchase
price. This is the sole and exclusive remedy for breach of
this warranty. Any modification of this Warranty shall be binding only if such
modification is in writing, and signed by an Adaptive officer. This
information supersedes all other sales information received by the purchaser
during the sales process.
THE FOREGOING WARRANTY SHALL BE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, AND ALL OTHER
WARRANTIES OTHERWISE ARISING BY OPERATION OF LAW, COURSE OF DEALING, CUSTOM,
TRADE OR OTHERWISE.
LIMITED LIABILITY
Adaptive Frequency Inc. (“Adaptive”) shall not be liable in contract or in
tort including, without limitation, negligence, strict liability or otherwise
for loss of sales, revenues or profits; cost of capital or funds; business
interruption or cost of downtime, loss of use, damage to or loss of use of
other property (real or personal); failure to realize expected saving;
frustration of economic or business expectations; claims by third parties
(other than for bodily injury), or economic losses of any kind; or for any
special; incidental, indirect, consequential, punitive or exemplary damages
arising in any way out of the performance of, or failure to perform, its
obligations under any contract for sale of product, even if Adaptive could
foresee or has been advised of the possibility of such damages.
In addition, Adaptive’s liability shall be limited to the purchase price of
the Adaptive product or products that is the source of the claim, and in no
event more than the aggregate purchase price, for the last six months, of
Adaptive’s products purchased by the purchasing party. The Parties expressly
agree that these limitations on damages are allocations of risk constituting,
in part, the consideration for this agreement, and also that such limitations
shall survive the determination of any court of competent jurisdiction that
any remedy provided in these terms or available at law fails of its essential
purpose.
Copyright © 2022 Adaptive Frequency, Inc.
Document 1.4-12-09-2022
Printed in Taiwan