How to Determine Manufacture Date from Duke Equipment Serial Numbers

Determine Manufacture Date
Determine Manufacture Date

FCP Model Number Convention

Flush Mount Refrigeration Components

FLUSH MOUNT COLD PAN CONDENSING UNIT GRAPHICS/PART #’S 6 SECTION CONFIGURATION SHOWN

Flush Mount Refrigeration Components

ITEM| PART #| DESCRIPTION| 1M-N7| 2M-N7| 3M-N7| 4M-N7| 5M-N7| 6M-N7
---|---|---|---|---|---|---|---|---


1

| 516823| Unit, Cond. ,(74/86)120v 60hz .1930btu/Hr M6zl-H054-Iaa-141| | | 1| 1| 1| 1
516820| Unit, Cond. ,(36/48/60)120v 60hz .1300btu/Hr M6zl-H032- Iaa-141| 1| 1| | | |
2| 226052| Receiver, Parker P# Rt306v-Ts| 1| 1| 1| 1| 1| 1
3| 226117| Accumulator, Sporlan 3″ Dia. 3/8″ Fittings 1bs| 1| 1| 1| 1| 1| 1
526805| Insulation, Accumulator 3″ Dia. 3/8″ Fittings| 1| 1| 1| 1| 1| 1
4| 216415| Glass, Sight Sa-12s Std#7| 1| 1| 1| 1| 1| 1
5| 226039| Filter Drier, W/Pressure Tap C-032-S-T 1/4 Copper Conn| 1| 1| 1| 1| 1| 1



6

| 516851-1| Valve Txv Efd-1/3-Z 1/4″X3/8″ Odf 60 Inch 48 Psi Flow Bench Setting| | | | | 1| 1
526320-2| Valve Txv Efd-1/4-Z 1/4″X3/8″ 44 Psi Flow Bench Setting| | 1| | | |
526320-3| Valve Txv Efd-1/4-Z 1/4″X3/8″ 48 Psi Flow Bench Setting| | | | | |
216859| TXV Insulation| 1| | 1| 1| |
7| 213499| Tubing, 1/2″Id
8| 526064| Plastic Barbed Tube Fitting For Air And Water, Elbow Adapter, For 3/4″ Tube Id X 1/2 Npt Male
9| 524524| Tee Adapter Plastic Barbed ¾ Tube X ½ Npt Male
10| 223564| Clamp, Stainless #C16 Stainless
11| 224300| Adapter, Brass, Gardenhose 3/4″M Npt – 3/4″M G.h.
12| 213608| Fitting, Garden Hose Female 3/4″ Thread – 1/2″ Barb
13| 213234| Clamp, Hose 1/2″

FLUSH MOUNT COLD PAN CONDENSING UNIT GRAPHICS/PART #’S PART # 516823 SHOWN BELOW

Flush Mount Refrigeration Components

ITEM PART # DESCRIPTION QTY
1 227852 Coil Condenser 066-0337-05, 1
2 217851 Assembly, Fan Motor/Brkt 050-0300-00 1
3 227853 Guard Condr. Fan Use #527863 1
4 226407 Control, High Press. cutout 440 Cutout/325cutin 1
5 227854 Compressor AFE17C4E-IAA-901 1

6

| 227861| Compressor, Start Cap 914-0053-04, For 516803,516823| 1
227857| Relay 940-C411-89, For 516803, 516823| 1
227859| Protector 971-0561-48, For 516803, 516823| 1
7| 217819| Blade, Fan #083-0130-00 74-86 Trichn| 1

FLUSH MOUNT COLD PAN CONDENSING UNIT GRAPHICS/PART #’S PART # 516820 SHOWN BELOW

Flush Mount Refrigeration Components

ITEM PART # DESCRIPTION QTY
1 227852 Coil Condenser 066-0337-05, 1
2 217851 Assembly, Fan Motor/Brkt 050-0300-00 1
3 227853 Guard Condr. Fan Use #527863 1
4 226407 Control, High Press. cutout 440 Cutout/325cutin 1
5 527844 Compressor,1/3hp 120v 60hz 1

6

| 227855| Start Cap Compressor 914-0053-00, For 516800, 516820| 1
227856| Relay 940-C411-72, For 516800, 516820| 1
227858| Protector 971-0554-28, For 516800, 516820| 1
7| 217819| Blade, Fan #083-0130-00 74-86 Trichn| 1

Flush Mount Control Components/Drain

FLUSH MOUNT COLD PAN CONTROL GRAPHICS/PART #’S IOA BOX, PART # ELC2002 SHOWN BELOW

Flush Mount Control Components/Drain

ITEM PART # DESCRIPTION QTY
1 600561 Kit, IOA Board Replacement 1
2 ELC0402K Kit, Pcb Can Bus Replacement 1
3 115330 Relay,Dpdt,40a,120vac Coil 1
4 ELC0661 Wire Harness Kit For Elc2001 Ioa Box (1-Cold) 1
5 600575 Kit, Ioc-G Board Replacement 1
6 ELC0625 Harness – Box To IOC-G Pcb 72″ 1
7 ELC0574 Heyco Epdm Snap-In Liquid Tight 1
8 ELC0575 Utility Outlet, Snap-In, Nema 1-15r 1
9 ELC0572 Splice Connector Wago 3-Position 3
10 ELC0571 Splice Connector Wago 2-Position 1
11 ELC0451 Shunt Jumper

FLUSH MOUNT COLD PAN CONTROL GRAPHICS/PART #’S

Flush Mount Control Components/Drain

ITEM PART # DESCRIPTION QTY
1 526814 Control Elreha, 120v Digital, Tarn 21170v K004, Includes
Gasket, Faceplate & 1 Sensor 1
2 160406 Switch,Lighted,Dpst,20a @125v Lrgsck611-Ra-B-E-125n 1
3 522429 Cord, Power Asy. 15amp, 125v W/Terminals,Ruf/Rbc 1

Flush Mount Refrigeration Flow Diagram

FLUSH MOUNT COLD PAN REFRIGERATION FLOW DIAGRAM

Flush Mount Refrigeration Flow Diagram

Flush Mount (448A Refrigerant)
Refrigerant Charge 36″ – 22oz 48/60″ – 23oz
Superheat 4-10°
Sub Cooling 10-15°
LRA 26.5
RLA 7.3
Oil Type POE 10oz
Condenser Fan 120vac .36a
Evaporator Fan N/A
High Pressure Range @75° 170-190 psig
Low Pressure Range @75° 25-40 psig
High Pressure Cut-Out Cut-In 120vac 440 325

Flush Mount Wire Diagram

FLUSH MOUNT COLD PAN WIRE DIAGRAM

Flush Mount Wire Diagram

Customer Support

Duke Manufacturing Co.
2305 N. Broadway
St. Louis, MO 63102

Phone: 314-231-1130
Toll Free: 1-800-735-3853
Fax: 314-231-5074

www.dukemfg.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals