ENGiNDOT TKSUP01A Sump Pumps User Manual
- June 14, 2024
- ENGiNDOT
Table of Contents
ENGiNDOT TKSUP01A Sump Pumps
Product Information
Specifications
- Model: TKSUP01A
- ID: LSD-370P
- Power supply: 115V
- HP: 1/2
- Amp: 5A
- GPM of Water @ Total Feet of Lift:
- 0ft: 3300 GPM
- 5ft: 2900 GPM
- 10ft: 2590 GPM
- 15ft: 2210 GPM
- 20ft: 1550 GPM
- Max. Lift: 27.7ft
- Liquid temperature range: Not specified
- Discharge size: Not specified
- Minimal Sump basin depth: Not specified
- Minimal Sump basin diameter: Not specified
Product Usage Instructions
Safety Information
Before using the sump pump, please adhere to the following safety guidelines:
- Do not splice the electrical power cord.
- Do not allow the electrical cord to become submerged.
- Do not use extension cords as they can be a fire hazard and reduce voltage.
- Do not handle or service the pump while it is connected to a power supply.
- Do not remove the grounding prong from the plug or modify the plug to protect against electrical shock.
- Plug the pump into a 3-wire, grounded, grounding-type receptacle.
Pre-Installation
Before installing the sump pump, please consider the following:
- This submersible sump pump is designed for home sump applications and should only be used for pumping water.
- Do not use the pump for applications involving salt water or brine, waterfalls, fountains, or water recirculation.
- This pump is not designed for use as a swimming pool drainer.
Installation Requirements
During installation, please follow these requirements:
- To reduce motor noise and vibrations, connect a short length of rubber hose (1-7/8 in. (47.6 mm) I.D.) into the discharge line near the pump using suitable clamps.
- If the check valve does not have an air bleed hole, drill a 1/8 in. (3.2 mm) hole in the discharge pipe just above where it screws into the pump discharge to prevent air locks.
- If the pump discharge line is exposed to an outside subfreezing atmosphere, ensure that a portion of the line is installed so any water remaining in the pipe can drain to the outfall by gravity to prevent freezing and potential damage to the pump.
- Do not operate the pump unless it is submerged in water as the shaft seal depends on water for lubrication.
- Do not change the preset tether switch length.
Electrical Requirements
For automatic operation, plug the pump into a GFCI wall outlet and connect it
to an individual branch circuit with no other outlets or equipment in the
circuit.
Size fuses or circuit breakers according to the chart:
HP | Voltage | Individual Branch Circuit Required (Amps) |
---|---|---|
1/2 | 115 | 15 |
Care and Cleaning
To maintain the sump pump’s performance, follow these care and cleaning instructions:
- No specific care and cleaning instructions are provided in the manual.
Troubleshooting
If you encounter any issues with the sump pump, refer to the troubleshooting section in the user manual for assistance.
FAQ
-
Q: Can I use this pump for applications involving salt water or brine?
A: No, using this pump for saltwater or brine applications will void the warranty. -
Q: Can I use this pump as a swimming pool drainer?
A: No, this pump is not designed for use as a swimming pool drainer. -
Q: Can I operate the pump without it being submerged in water?
A: No, the pump’s shaft seal depends on water for lubrication. Operating the pump without submerging it in water may damage the seal.
Safety Information
- Do not splice the electrical power cord.
- Do not allow the electrical cord to become submerged.
- Do not use extension cords. They are a fire hazard and can educe voltage sufficiently to prevent pumping and/or damage the motor.
- Do not handle or service the pump while it is connected to a power supply.
- DO NOT remove the grounding prong from the plug or modify the plug to protect against electrical shock.
- The power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug the pump into a 3-wire, grounded, grounding type receptacle. Connect the pump according to electrical codes that apply.
DANGER
- DANGER: Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death. DANGER: ALWAYS disconnect the power to the pump before servicing. DANGER: Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor hous-ing
- DANGER: Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or ir water before disconnecting the power WARNING: Release all pressure and drain all water from the system before servicing any component.
- WARNING: Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.
- WARNING: Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an exten-sion cord to power this pump is not permitted.
- WARNING: Wear safety goggles at all times when working with pumps.
- WARNING: This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.
- WARNING: Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords. WARNING: Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
- WARNING: Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
- CAUTION: Do not lift the pump by the power cord.
- CAUTION: know the pump and its applications, limitations, and potential hazards.
- CAUTION: Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maxi-mum efficiency. It will also help prevent the pump from clogging resulting in premature failure.
- CAUTION: Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting.
- CAUTION: Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Admin-istration (OSHA) guidelines must be followed.
- IMPORTANT: Ensure the electrical power source is adequate for the require-ments of the pump.
- IMPORTANT: This pump is made of high-strength, corrosion-resistant materi-als. It will provide trouble-free service for a long time when properly installed, maintained and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies. IMPORTANT: The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and restart when the acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.
Warranty
The manufacturer warrants the products to be free from defects in materials and workmanship for a period of two year from date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal use and service. If within one year this product is found upon examination by the manufacturer to be defective in materials or workmanship, the manufactur-er’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect or mishandling. Your original receipt of purchase is required to determine warranty eligibility. This Limited Warranty does not cover products which have been dam-aged as a result of an accident, misuse, abuse, negligence, alteration, improper installation or maintenance, or failure to operate in accordance with the instruc-tions supplied with the products, or operational failures caused by corrosion, rust, or other foreign materials in the system. Requests for service under this warranty shall be made by returning the defective product to the manufacturer as soon as possible after the discovery of any alleged defect. The manufacturer will subsequently take corrective action as promptly as reasonably possible. The manufac-turer does not warrant and especially disclaims any warranty, whether express or implied, of fitness for a particular purpose other than the warranty contained herein. This is the exclusive remedy and any liability for any and all indirect or consequential damages or expenses whatsoever is excluded. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Pre-Installation
PLANNING INSTALLATION
This submersible sump pump is designed for home sump applications. Use this
pump only for pumping water. This unit is not designed as a waterfall or
fountain pump, or for applications involving salt water or brine. Use with
waterfalls, fountains, salt water or brine will void the warranty. Do not use
where water recirculates. This pump is not designed for use as a swimming pool
drainer.
INSTALLATION REQUIREMENTS
- NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay, or gravel surfaces. “
- Use a rigid plastic pipe for the discharge. Do not use ordinary pipe joint compounds. Pipe joint compounds can attack plastics.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used, make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump movement, switch interference, and prevent the pump from starting or stopping.
- To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. (47.6 mm) I.D., e.g radiator hose) can be connected into the discharge line near the pump using suitable clamps.
- If the check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8 in. (3.2 mm) hole in the discharge pipe just above where the discharge pipe screws into the pump discharge. Be sure the hole is below the waterline and the check valve to prevent air locks.
- If the pump discharge line is exposed to outside subfreezing atmosphere, a portion of line exposed must be installed so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause water trapped in the discharge to freeze which could result in damage to the pump.
- The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water as the seal may be damaged if allowed to run dry. Do not change the preset tether switch length.
ELECTRICAL REQUIREMENTS
- For automatic operation, plug the pump into a GFCI wall outlet.
- Connect the pump to an individual branch circuit with no other outlets or equipment in the circuit. Size fuses or circuit breakers according to this chart
HP| Voltage| Individual Branch Circuit Required (Amps)
---|---|---
1/2| 115| 15
PERFORMANCE CHART
Model | HP | Amp | GPM of Water @ Total Feet of Lift | Max. Lift |
---|---|---|---|---|
0ft | 5ft | 10ft | 15ft | 20ft |
TKSUP01A | 1/2 | 5A | 3300 | 2900 |
Power supply | 115 V, 60 Hz, 15 Amp circuit | |||
--- | --- | |||
Liquid temperature range | 32°F – 95°F (0° — 35°C) | |||
Discharge size | 1-1/2 (3/4 and 1-1/4 adaptor included) | |||
Minimal Sump basin depth | 14 inch | |||
Minimal Sump basin diameter | 18 inch |
TOOLS REQUIRED
MATERIALS REQUIRED (NOT INCLUDED)
NOTE : Hardware not shown to actual size.
Part | Description | Quantity |
---|---|---|
AA | Discharge pipe | 1 |
BB | Check valve | 1 |
CC | 90 degrees elbow | 1 |
DD | Pipe adapter | 1 |
Installation
- Preparing a pump basin
- The sump pump must be installed in a sump basin with a minimum diameter of 10 in. (254 mm) for vertical switch models and 14 in. (356 mm) for tethered float switch models.
- The sump basin must have a minimum depth of 14 in. (356 mm) for vertical switch models and 18 in. (457 mm) for tethered float switch models.
- The sump basin can be constructed of tile, concrete, steel, or plastic. Check local codes for approved materials and for proper installation.
Placing the pump in a basin
- Place the pump on a hard surface inside the sump basin. Do not install the pump on clay, earth, or sand surfaces.
- Clear the sump basin of debris which could clog the pump. Keep the inlet screen clear.
Installing the discharge plumbing
- Attach a pipe adapter (DD) to the discharge pipe (AA). Wrap the threads with PTFE pipe thread sealant tape.
- Screw the discharge pipe (AA) onto the pump (A) hand-tight, plus 1-1/2 turns. Install an in-line check valve (BB) or an in-pump check valve.
Operation
Connecting power
Plug the power cord into a 115 V GFCl power outlet.
WABNING : Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water, unless you are certain all power has been turned off to the pump. Remember, the pump should be connected only to a prop- erly grounded, GFCl outlet
Operating the pump
- After connecting power to the pump, test the pump by filling the sump basin with water and observing pump operation through one complete cycle.
- The motor is equipped with an automatically-resetting thermal overload protector.
- If the motor gets too hot, the overload protector will shut off the pump before it is damaged. When the motor has cooled sufficiently, the overload protector will reset, and the motor will restart.
- The pump will not remove all water. If operating a pump manually, and suddenly no water comes out of the discharge hose, shut off the unit immediately. The water level is probably very low and the unit has broken prime.
NOTICE : If the overload protector stops the pump repeatedly, disconnect the power from the pump and check to find the problem. Low voltage, a long extension cord, clogged impeller, screen blocked by debris or water that is too hot can cause motor overheating.
Care and Cleaning
- WARNING : Before removing the pump from the basin for service, always disconnect electrical power to the pump and control switch. Do not lift the pump by the power cord.
- Unscrew the bolts (4) and remove the volute (3).
- If necessary use a flathead screwdriver to hold the shaft (1), then turn the impeller (2) counterclockwise to release the impeller (2).
- Remove debris from around the shaft (1) and the impeller (2).(Impeller is shown removed for clarity. Do not remove impeller.)
- Reassemble the pump.
Troubleshooting
Problem | Probable Cause | Solution |
---|
The pump fails to operate.
| There is no power| Reset the GFCl switch Reset the circuit breaker
Make sure the pump is plugged in
Clean the plug prongs
The impeller is blocked.| Remove the debris around the impeller.
The motor failed.| Replace the pump.
The pump oper- ates, but pumps little or no water.
| The screen is blocked.| Clean the screen.
Debris is caught in the impeller or discharge.| ****
Remove the debris.
The impeller is broken.
| ****
Replace the impeller.
The pump starts and stops too often.
| There is a backflow of water from the piping or the check valve is leaking|
Install or replace the check valve.
Your Service Includes
24-Month Coverage
Within 24 months of purchase, we will provide timely and effective online
after-sales service. We will repair or replace any defective product (due to
manufacturing fault) within the service period.
How to Return Your ENGINDOT Product
- Contact support@wetotek.com with your order number.
- We will issue you a return label for your return.
- Tear off the “Return Details” page and fill in the details.
- Include this inside your return package.
We will issue your replacement/refund on receiving the return package.
Return Details
In order to process your return as quickly as possible, we require the
following information. Please fill out this form and include it in your return
package.
Purchase Name:
|
---|---
Order Number:
|
Date of Purchase:|
Your Email Address:|
Place of Purchase:|
If your purchase was fulfilled by Amazon, please use Amazon’s 30-day return
service.
Model :TKSUP01A
ID :LSD-370P
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>