JOLUX LED Spring Hook Retrofit Downlight Installation Guide
- June 14, 2024
- Jolux
Table of Contents
JOLUX LED Spring Hook Retrofit Downlight
INSTALLATION INSTRUCTIONS
-
Turn power off
-
Remove previous fixture or bulb
-
Use the right angle side of short spring to hook the ring of E26 adaptor![4. Screw in the E26 adaptor into the open socket
-
Plug in the quick connector](https://manuals.plus/wp-content/uploads/2023/11/JOLUX-LED-Spring-Hook-Retrofit-Downlight-fig-2.jpg)
-
Screw in the E26 adaptor into the open socket
-
Plug in the quick connector
-
Pull another side of spring to hook the ring on lamp backside
-
Release the lamp to be flush with ceiling
-
Turn power on and test
Spring Adjustment
- One long spring hook When the distance from the lamp socket to the ceiling is greater than 5.71 inches.
- One short spring hook When the distance from the lamp socket to the ceiling is between 5.12 and 5.71 inchese
- Two short spring hooks: When the distance from the lamp holder to the ceiling is less than 5.12 inches
WARNING
- Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.