EuroClad Selekta Design App User Guide
- June 14, 2024
- EuroClad
Table of Contents
V2.0 August 2022
EuroClad-Selekta
DESIGN GUIDE
General and product information
PURPOSE
This design guide relates to the design and specification of EuroClad-Selekta.
IMPORTANT DOCUMENTS
This guide must be read in conjunction with these documents:
EuroClad-Selekta cladding pass™
EuroClad-Selekta specification guide
EuroClad-Selekta installation guide
EuroClad-Selekta care and maintenance guide.
PSP supplies details to assist in the detailing and specification of EuroClad-
Seleka.
SKILLS REQUIRED
This guide is suitable for use by a licensed building practitioner licensed to
the relevant class.
FOR MORE HELP
Technical assistance is available at
www.euroclad.co.
While all reasonable efforts have been made to ensure the accuracy of
information provided, this guide is guide only. It may be subject to change.
FOR OUR WARRANTY
Refer to www.euroclad.co.
PRODUCT DESCRIPTION
EuroClad-Selekta is a prefinished, composite, shiplap cladding. It is
manufactured from processed timber fibres and binding agent (phenolic
adhesive). The cladding is embossed in a variety of realistic timber grains
and colours.
EuroClad-Selekta is available in the following sizes:
Thickness (mm): 18
Length (mm): 5400
Width (mm): cover 155, sheet 170.
EuroClad-Selekta is manufactured in Germany by Werzalit. Only wood product
from forests certified PEFC (Program for the Endorsement of Forest
Certification) is used. This ensures that the manufacturing process is
sustainable with regard to economic, ecological and social standards.
SCOPE AND LIMITATIONS
Refer to EuroClad-Selekta cladding passTM. MORE
INFO
Design
To specify EuroClad-Seleka the required steps are described in this section.
Links to details to be included on the relevant plan sheet, are provided.
STEP 1: CONFIRM SCOPE
Confirm the proposed use is within the scope and limitations of the pass TM.
STEP 2: CONFIRM RELATED BUILDING WORK
EuroClad-Seleka is suitable for use with a timber or lightweight steel framed
building.
Confirm the primary structure:
complies with the NZ Building Code and is designed in accordance with NZS
3604:2011 (section 2) or NASH Design Standard: 2019 Parts 1 and 2; or
is suitable for the intended building work, if the building is an existing
building.
EuroClad-Seleka must be used with an appropriate building underlay or rigid
air barrier and fixings.
Where the wind zone is extra high, a rigid air barrier that complies with
Table 23 of Acceptable Solution E2/AS1 is to be used.
Confirm the building underlay and fixings comply with Table 23 of Acceptable
Solution E2/AS1.
STEP 3: DETAIL THE USE OF THE PRODUCT
Select the orientation of the cladding
EuroClad-Selekta may be installed vertically or horizontally.
Detail cavity system
Confirm the importance level of the building in accordance with AS/NZS 1170.
EuroClad-Seleka must be installed over a drained and ventilated cavity unless the
building is unlined or importance level 1, in which case EuroClad-Selekta may be directfixed.
E2/AS1 may be relied upon for direct fixed installation subject to section 1.2.1 and associated comment.
For vertical installation over a cavity, castellated timber battens with chamfered tops are required. For horizontal installation over a cavity, solid timber battens are required.
Select the relevant PSP details to ensure that the battens are detailed in accordance with EuroClad-Selekta details.
Detail the cavity closers
Select the relevant PSP details to ensure that the cavity closers are detailed in accordance with EuroClad-Selekta details.
Detail laps, penetrations, joints and corners
Select the relevant PSP details to ensure that laps, penetrations, joints,
external and internal corners are detailed in accordance with EuroClad-Selekta
details.
Detail windows, doors and flashings
Select the relevant PSP details to ensure that the windows, doors and
flashings are detailed in accordance with EuroClad-Selekta details.
For more information on EuroClad details please follow the link MORE INFO
STEP 4: QUALITY CHECK
Confirm all relevant design requirements are met.
Check documentation; including plans, details and specification guide have
been correctly completed.
Ensure the building consent plans and specifications clearly define and
include:
all relevant installation details
fixings – type and installation.
Check that all required documentation for the building consent application is
collated.
Document prepared by TBB August 2022 This document is uncontrolled in printed form. See www.euroclad.co for current version. Copyright © 2022 PSP
euroclad@psp.co.nz
09 415 2809
www.euroclad.co
References
- EuroClad - Selekta Weatherboard is a unique, pre-finished engineered timber cladding system with a beautiful wood-grain embossed surface | Euroclad
- PSP pass™ Landing — The Building Business
- EuroClad | Cladding - Building Solutions