Miele PG 8056-1 U Built Under Fresh Water Dishwasher Instruction Manual

June 14, 2024
Miele

Miele-logo

Miele PG 8056-1 U Built Under Fresh Water Dishwasher

Product Information

Specifications

  • Model : PG 8055 – PG 8099

  • Installation Plan : Available in multiple languages

  • Product Number : M.-Nr. 11 768 930

  • Electrical Connection:

    • EU, CH, CN, RU, U A, KZ: 3N AC 400 V/50 Hz, 8.9 kW, 3 x 16 A,
      1.7 m

    • BE, NO: 3N AC 400 V/50 Hz, 8.9 kW, 3 x 15-16 A, 1.8 m

    • AU: 3N AC 400 V/50 Hz, 5.9 kW, 1 x 30-32 A, 1.9 m

    • US, CA: AC 230 V/50 Hz, 3.4 kW, 1 x 16 A, 1.7 m

  • Water Connection:

    • Cold Water: 0 – 60 mm
    • Weight: 62.5 kg
    • Noise Level: 47 dB
  • Dosage:

    • Internal Dosage Pump (DOS): 0.35 kWh
    • External Dosage Pump: 0.40 kWh

Product Usage Instructions

Installation
For safe installation and commissioning of the dishwasher, please read the installation plan, the service documentation, and the operating instructions. This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on site for the installation of the dishwasher.

Installation Requirements:

  • This dishwasher must be installed by an authorized technician.
  • Installation must be done in accordance with all applicable standards and guidelines, including legal requirements and health and safety regulations.

Electrical Connection
Connection to the electrical supply should be in accordance with valid regulations and safety standards. The connection cable must be protected from the risk of thermal damage. We recommend connecting the dishwasher to the power supply via a suitable plug and socket as this will make it easier to carry out the electrical safety test during commissioning and after any service work. For hard-wired dishwashers, connection should be made via a suitable mains switch with all-pole isolation, which in the off position ensures a 3 mm gap between all open contacts.

Water Connection

  • Cold Water: Ensure a water connection of 0 – 60 mm.

Dosage

  • Internal Dosage Pump (DOS): Power Consumption: 0.35 kWh
  • External Dosage Pump:  Power Consumption: 0.40 kWh

FAQ

Can I install the dishwasher myself?
No, the dishwasher must be installed by an authorized technician.

What should I do if I encounter any issues during installation?
Please refer to the service documentation and contact customer support for assistance.

Installation notes
For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation and the operating instructions. This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on site for the installation of the dishwasher.

Installation requirements
This dishwasher must be installed by an authorized technician in accordance with the installation instructions supplied. This dishwasher must be installed under all applicable standards and guidelines, including legal requirements and health and safety regulations.

Electrical connection
Connection to the electrical supply should be in accordance with valid regulations and safety standards. The connection cable must be protected from the risk of thermal damage. We recommend connecting the dishwasher to the power supply via a suitable plug and socket as this will make it easier to carry out the electrical safety test during commissioning and after any service work. For hard-wired dishwashers, the connection should be made via a suitable mains switch with all-pole isolation, which in the off position ensures a 3 mm gap between all open contacts. Both the main switch and the socket must be easily accessible after installation.

Faulty components must only be replaced by genuine Miele original spare parts. Only when these parts are fitted can the safety standards of the machine be guaranteed. If the connection cable is faulty it must only be replaced by a Miele-approved service technician to protect the user from danger.

Equipotential bonding and earthing
For added safety, the dishwasher should be protected with a residual current device with a trip current of 30 mA. Equipotential bonding should be carried out if required. The screw connection point for equipotential bonding is located at the back of the dishwasher.

Water connection (without steam condenser)
The dishwasher can be plumbed in to the cold water, hot water and drainage points without a backflow protection device. The stopcock to the water supply must be easily accessible. The water supply to the dishwasher can be connected to either cold water or hot water.

Water connection (with steam con-denser)
The machine can be plumbed in to the cold water, hot water, demin-eralised water and drainage points without a backflow protection device. Use the enclosed Y-piece to establish the water intake for the dishwasher (cold water) and the steam condenser. Alternatively, you can install an additional cold water line to connect the steam condenser. If hot water is not available, both intake hoses (cold and hot water) must be connected to the cold water supply via a Y-piece. The stopcock to the water supply must be easily accessible.

Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any furniture and fittings in the room must therefore be suitable for purpose. If the machine is fitted under a suitable worktop, the panel supplied must be fitted above the door aperture to protect the work-top from moisture damage.

Connecting an external dispensing system
Up to two dispensing systems for liquid cleaning agents and rinsing agents can be connected to the back of the dishwasher. Machines with integrated dispensing systems have an external connection for rinsing agents.

Liquid agents:
Position of external containers
The liquid agent container for external dispensing must be positioned either next to or underneath the machine only. The container may be placed on the floor or in an adjacent cabinet. Do not place the con-tainer on top of or above the machine. Make sure that the dispensing hose does not get kinked or trapped.

Appliance dimensions

Freestanding appliance

  • PG 8055
  • PG 8056 (DOS)
  • PG 8057 TD (DOS)
  • PD 8058 (DOS)
  • PG 8059 (DOS)
  • PG 8096 (DOS)
  • PG 8099 (DOS)Miele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-fig- \(1\)

Built-under appliance

front plinth area, varies depending on appliance type

  • PG 8055 U, PG 8056 U, PG 8056-1, PG 8061 UMiele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-fig- \(2\)
  • PG 8056 U DOS, PG 8096 U (DOS), PG 8099 U (DOS)Miele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-fig- \(3\)

front plinth area, varies depending on appliance type

  • PG 8057 TD U, PG 8058 U, PG 8059 UMiele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-fig- \(4\)
  • PG 8057 TD U DOS, PG 8058 U DOS, PG 8059 U DOSMiele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-fig- \(5\)

Connections on the back of the appliance

  • PG 8055, KW only
  • PG 8056 (DOS)
  • PG 8061, PG 8056-1,
  • PG 8096 (DOS)
  • PG 8099 (DOS)
  • PG 8057 TD (DOS)
  • PG 8058 (DOS)
  • PG 8059 (DOS)* only PG 8058 (DOS)

On-site connectionsMiele-PG-8056-1-U-Built-Under-Fresh-Water-Dishwasher-
fig- \(8\)

KW Cold water WW Hot water
AW Wastewater EL Electrical connection
DS External dispensing, power supply connection PA Equipotential bonding
VE DI water DK Cold water for steam condeser

Technical data

Electrical connection EU, CH, CN, RU, UA, KZ

Voltage| | 3N AC 400 V /

50 Hz

| AC 230 V / 50 Hz
---|---|---|---
Power rating| | 8.9 kW| 3.4 kW
Fuse rating| | 3 x 16 A| 1 x 16 A
Mains connection cable, min. cross-section| | 5 x 2.5 mm²| 3 x 1.5 mm²
Length of connection cable (H05(07)RN-F)| | 1.7 m| 1.7 m

Electrical connection BE, NO

Voltage 3 AC 230 V / 50 Hz AC 230 V / 50 Hz
Power rating 7.1 kW 2.9 kW
Fuse rating 3 x 20 A 3 x 16 A
Mains connection cable, min. cross-section 3 x 1.5 mm² 3 x 1.5 mm²
Length of connection cable (H05(07)RN-F) 1.7 m 1.7 m

Electrical connection AU

Voltage| 3N AC 400 V /

50 Hz

| AC 230 V / 50 Hz| AC 230 V / 50 Hz
---|---|---|---
Power rating| 8.9 kW| 5.9 kW| 2.9 kW
Fuse rating| 3 x 15–16 A| 1 x 30–32 A| 1 x 15–16 A
Mains connection cable, min. cross-section| 5 x 2.5 mm²| 3 x 4 mm²| 3 x 1.5 mm²
Connection cable length| 1.8 m| 1.9 m| 1.8 m

Electrical connection US, CA

Voltage| 2 AC 208 V 60 Hz| 3 AC 208 V 60 Hz| 3 AC 240 V 60 Hz| 2 AC 240 V 60 Hz
---|---|---|---|---
Power rating| 5.8 kW| 5.8 kW| 5.8 kW| 5.8 kW
Fuse rating| 2 pole x 30 A| 3 pole x 20 A| 3 pole x 20 A| 2 pole x 30 A
Mains connection cable, min. cross-section| 3 x AWG 10

(3 x 5.2 mm²)

| 4 x AWG 12

(4 x 3.3 mm²)

| 4 x AWG 12

(4 x 3.3 mm²)

| 3 x AWG 10

(3 x 5.2 mm²)

Connection cable length| approx. 5’9”

(1.8 m)

| approx. 5’9”

(1.8 m)

| approx. 5’9”

(1.8 m)

| approx. 5’9”

(1.8 m)

Electrical connection| NEMA L6-30| NEMA L15-20| NEMA L15-20| NEMA L6-30

Cold water

Max. temperature 20 °C 68 °F
Max. permitted water hardness 10714 mmol/l / 60 °dH 63 gpg
Recommended flow pressure 200 kPa 29 psi
Minimum flow pressure with extended water intake 100 kPa 14.5 psi
Maximum flow pressure 1000 kPa 145 psi
Flow rate 7.5 l/min 2 gal/min
On-site threaded union in accordance with DIN 44991 (flat sealing) 3/4 inch

3/4 Male Garden Hose Thread
Inlet hose length| 1.7 m| 5′ 7″
Length of steam condenser inlet hose| 1.7 m| 5′ 7″

Hot water

Max. temperature 65 °C 149 °F
Max. permitted water hardness 10714 mmol/l / 60 °dH 63 gpg
Recommended flow pressure 200 kPa 29 psi
Minimum flow pressure with extended water intake 40 kPa 5.8 psi
Maximum flow pressure 1000 kPa 145 psi
Flow rate 7.5 l/min 2 gal/min
On-site threaded union in accordance with DIN 44991 (flat sealing) 3/4 inch

3/4 Male Garden Hose Thread
Inlet hose length| 1.7 m| 5′ 7″
Length of steam condenser inlet hose| 1.7 m| 5′ 7″

Wastewater

Max. waste water temperature 85 °C 185 °F
Max. waste water temperature PG 8057 TD 93 °C 200 °F
Drain hose length, standard 1.5 m 4′ 9″
Drain hose, max. drainage length 4.0 m 13′ 1″
Max. drain pump delivery head from bottom edge of machine 1.0 m 3′ 3″
Max. transient flow rate 16 l/min 4.2 gal/min
On-site sleeve for drain hose (Ø x length) 22 x 30 mm 7/8″ x 1 3/16″
Drain hose (Ø) 22 mm 7/8″

Machine data

Machine feet height adjustment 0 – 60 mm 0 – 2 3/8″
Max. net weight 62.5 kg 138 lbs
Max. floor load during operation 1200 N 1200 N
Min. access width, incl. transport pallet 670 mm 26 3/8″
Min. access depth, incl. transport pallet 740 mm 29 3/8″
Min. access height, incl. transport pallet 920 mm 36 1/4″

Sound pressure LpA, washing and drying

PG 8055, PG 8056, PG 8056-1, PG 8096, PG 8099

| 47 dB| 47 dB
Sound pressure LpA, washing and drying PG 8057 TD, PG 8058, PG 8059| 45 dB| 45 dB

Dispensing Internal dispenser pump (DOS)

Max. delivery head 1.5 m 4.9″
Length of dispenser hose, back of appliance to suction lance ca. 1.8 m ca.

5.9″

External dispenser pump

Max. delivery head 1.5 4.9″
Length of dispenser hose, DOS module to suction lance ca. 1.8 ca. 5.9″
Length of dispenser hose, back of appliance to DOS module ca. 2.8 ca. 9.2″
Length of power cable, back of appliance to DOS module ca. 2.8 ca. 9.2

Heat dissipation rate to installation site

From heat radiation during operation 0.35 kWh 1194 BTU
From load items whilst unloading 0.40 kWh 1365 BTU

Installation requirements

Permitted ambient temperature 5 – 40 °C 40 – 104 °F
Max. relative humidity up to 31 °C 80 % 80 %
Rel. humidity, declining proportionally to 40 °C 50 % 50 %
Max. altitude above sea level up to 2000 m 2000 m

Manufacturer: Miele & Cie. KG Carl-Miele-Straße 29 33332 Gütersloh Germany