Welcome to use the “new generation” (wireless outdoor type) pet immunity infrared intrusion detectors. It adopts importer super low pow consumption digital microprocessor, rando dynamic time division and energy accumulate logic recessing technology, patented precise columnar Fresnel lens, Using high intelligent volume recognition + outdoor filter + dual infrared processor technology, adjustable pull counting. Working with advanced patent software technology, it features super detect performance and judges the real invader truly a can overcome the shortcoming of false alar  failed alarm and not alarm.

Characteristics

  • outdoor filter dual infrared processor technology;
  • Microprocessor with super low power consumption The use of general 5 batteries for more than 2 years, easy to buy, no need to change the battery;
  • Dual temperature compensation technologies
  • Adoption of detection technology of reflective mirror: overcome the shortcoming of traditional detector that does not alarm for crawling in
  • The technology of adjustable pulse counting
  • Dual induction technology
  • Time division technology with random dynamic
  • Fresnel optical lens + Volume identification can prevent mistaken alarm and omitted alarm
  • Detection distance: 6-9m
  • Detection angle: 110°
  • Transmission mode: Wireless 433.92mhz (1527)
  • The design of wall mounted and unique plug type installation
  • Pet immunity: 25KG

Note : the use of outdoor installation must be firmly installed; quiet location

Appearance introduction

covered area

  1. Adjust the product to the optimal direction so as to make test;
  2. At the far end of the covered area, perform transverse movement within the detection. scope with the speed of 1 step/second from any direction (about 0.75m/s). The protect will alarm after detecting and the LED light is on for 3 seconds (shown in figure 5)
  3. Carry out pacing from the opposite direction to ensure that perimeter of two sides point towards the center of the protected area at the detection center.
  4. If the ideal detection distance is not obtained, adjust the detection scope up and down to ensure that the detection point towards proper high and low scope.
  5. After adjustment of the detector angle is completed, walk test should be conducted again. Remark: After the walk test is qualified, set the test mode to the factory default mode

Considerations for installation

Please pay attention to the following condition to avoid that it cannot be used normally.

  1. Don’t aim at the pet exceeding 25kg.

  2. Forbid approaching to the

  3. Forbid approaching to the high voltage line

  4. place without firm foundation.

  5. Forbid installation facing the metal.

  6. Forbid facing the sun.

  7. Forbid facing the cold and heat source.

Installation and immunity

  • Installation height 2-2,4m

  • Pet immune: <25kg

Determine the detection of the detector and immunity of the pet according to the  height and angle.

About the installation height

Suitable height

Height is too high, there is a blind spot m

The height is too low and the distance is insufficient m 9

Install the battery

The bottom cover and the top cover snap are aligned and can be squeezed down.

Bracket mounting

Mounting bracket and waterproof cover: (1) Fix the mounting bracket to the wall with screws; (2) Fix the bracket screw and the waterproof cover; (3) Move the inner bayonet of the waterproof cover to the product port to move downward; as shown in the figure.

  1. Screw fixing bracket
  2. Fixed waterproof cover
  3. nest the infrared probe
  4. Correct installation

Work mode and pairing of the detector

N ormal work mode (saving power) :
After detector is triggered, the alarm is triggered after automatic interval of more than 5 seconds.

The pairing method with the host: after the

battery is installed correctly, LED light will be on. Set the host at the cold matching mode

(For entry to the matching code mode of the host, please refer to the instruction of the host).

Method A : move at the right front of the detector

Method B : shake it at the right front of the detector. The indicator light of the detector flashes and the machine gives out an alarm signal at the same time. When the host gives out corresponding prompt sound, indicate that match coding is  successful.

The method to make test in the

  1. Adjust the product to the optimal direction so as to make test;
  2. At the far end of the covered area, perform transverse movement within the detection scope with the speed of 1 step/second from any direction (about 0.75m/s). The protect will alarm after detecting and the LED light is on for 3 seconds (shown in figure 5)
  3. Carry out pacing from the opposite direction to ensure that perimeter of two sides point towards the center of the protected area at the detection center.
  4. If the ideal detection distance is not obtained, adjust the detection scope up and down to ensure that the detection point towards proper high and low scope.
  5. After adjustment of the detector angle is completed, walk test should be conducted again. Remark: After the walk test is qualified, set the test mode to the factory default mode.

Working mode setting

  1. Detection mode: after the detector is triggered, it cannot be triggered for alarm unless the interval is more than 5 seconds.
  2. Battery saving mode: Interval time of making alarm is three minutes
  3. Code Mode: Pressing the tamper button lasting three seconds to send an identifier to recue

Plunger pin operation

-FULL Testing mode
NORM Battery saving mode(Default
-CODE matching code mode

Pulse setting

1 pulse : Alarm against detecting one pulse signal

2 pulses : Alarm against detecting two pulses signal

Three pulses: Alarm against detecting three pulses signal

**Plunger pin operation

**

PLUS 1 pulse (Default)
PLUS 2 pulses
PLUS 3 pulses

Clearing and protection

The detector may be polluted with dirt after long- term use. At the moment, wet cloth may be used to wipe. Plenty of water is not allowed. Otherwise, the water may penetrate into the inside of the box cover, which may result in burnout of circuit.

After-sale service

Although our products have stable function, due to the limitation of its low pressure and use scope, we cannot guarantee that the alarm condition occurred in any condition can trigger the main body to give out alarm or not to give out alarm. The following is some common phenomenon.

  1. When the supply voltage of the detector is not sufficient, the product does not provide detection output alarm. Please check the power supply.
  2. When installation environment of the detector results in mistaken alarm and not alarm, please inspect environmental temperature and surrounding interference measures

Installation

Installation height: 2.2-2.7m;
working temperature: -20-50
Storage temperature: -20-60
Anti-visible light interference: larger than 6500LUX (indoors);
Overall dimension: 1206246mm;
cover: 1353570mm

Specification

  • Working voltage: 3V (1.5V AA battery*2)
  • Working current: 15mA
  • Standby current: ≤9µA
  • Maximum coverage area: 12m X 12m
  • Alarm indicator light: dual-color indicator light (green)
  • Working environment: outdoor / indoors
  • Anti-dismantling switch: normally close;
  • Transportation mode: Wireless 433
  • Alarm output: alarm condition report and anti- dismantling report

Detection area (shown in figure 2)

Angle detecting chart

Distance detecting chart