Yolin YL61F Electric Bike User Manual
- June 14, 2024
- Yolin
Table of Contents
- YL61F Electric Bike
- Electric Bike Display
- Specifications
- Product Usage Instructions
- 1. Installation
- 2. Power Supply Connection
- 3. Display Operation
- Q: How do I change the assist level on the Electric Bike
- Q: Can I use the Electric Bike Display with any electric
- Q: How do I reset the odometer on the Electric Bike
YL61F Electric Bike
Electric Bike Display
Specifications
- Product Name: Smart LCD display for electric bicycle
- Model Number: YL61F
- Power Supply: 36V/48V
- Display Rated Current: 15mA
- Display Maximum Current: 30mA
- Shutdown Leakage Current: [Value not provided]
Product Usage Instructions
1. Installation
To install the Electric Bike Display, follow these steps:
-
Ensure that the power supply to the electric bicycle is
switched off. -
Locate the appropriate mounting position on the handlebar of
the electric bicycle. -
Attach the Electric Bike Display securely to the handlebar
using the provided mounting bracket. -
Connect the display’s wiring harness to the corresponding
connector on the electric bicycle’s controller. -
Tighten all connections and ensure that the display is firmly
in place.
2. Power Supply Connection
The Electric Bike Display requires a 36V or 48V power supply. To
connect the power supply:
-
Locate the power supply connector on the display.
-
Connect the positive (+) wire of the power supply to the
positive terminal of the display. -
Connect the negative (-) wire of the power supply to the
negative terminal of the display.
3. Display Operation
The Electric Bike Display provides various information and
features. Here is an overview:
-
Battery Level: Displays the remaining battery capacity.
-
Speed: Shows the current speed of the electric bicycle.
-
Odometer: Tracks the total distance traveled.
-
Assist Level: Allows you to select different levels of
assistance. -
Backlight: Controls the display’s backlight for better
visibility in low-light conditions.
Refer to the user manual for detailed instructions on using each
feature.
FAQ (Frequently Asked Questions)
Q: How do I change the assist level on the Electric Bike
Display?
A: To change the assist level, press the up or down button on
the display until the desired level is selected. The current assist
level will be shown on the display.
Q: Can I use the Electric Bike Display with any electric
bicycle?
A: The Electric Bike Display is compatible with most electric
bicycles that have a 36V or 48V power supply. However, it is
recommended to check the compatibility with your specific electric
bicycle model before installation.
Q: How do I reset the odometer on the Electric Bike
Display?
A: To reset the odometer, press and hold the reset button on the
display for several seconds. The odometer will be reset to
zero.
Electric Bike Display
User’s Manual
YL61F
Tianjin Yolin Technology Co. Ltd.
TABLE OF CONTENTS
1. Product name and model number
……………………………………………………………………………………………………………………………2 2. Specification
………………………………………………………………………………………………………………………………………………………..2 3. Appearance and
Size ……………………………………………………………………………………………………………………………………………. 2 4. Function
overview and Functional areas ………………………………………………………………………………………………………………… 3
4.1 Functional overview …………………………………………………………………………………………………………………………………….3
4.2 Functional areas …………………………………………………………………………………………………………………………………………..3
4.3 Button definitions ………………………………………………………………………………………………………………………………………..3
5. Routine operation ………………………………………………………………………………………………………………………………………………… 3
5.1 Power on/off ………………………………………………………………………………………………………………………………………………. 3 5.2
Display interface switching …………………………………………………………………………………………………………………………..4
Figure 5-1 Display Interface Switching
……………………………………………………………………………………………………………………… 4 5.3 Walk boost mode
………………………………………………………………………………………………………………………………………… 4 5.4 Turning on/off
lights …………………………………………………………………………………………………………………………………….5 5.5 PAS level
selection ………………………………………………………………………………………………………………………………………5 5.6 Battery
level display …………………………………………………………………………………………………………………………………….5 5.7 Error
code display ………………………………………………………………………………………………………………………………………. 6 6.
Personalized parameter settings
…………………………………………………………………………………………………………………………….. 6 6.1 Backlight luminance
setting ………………………………………………………………………………………………………………………….7 6.2 Metric and
Imperial setting ………………………………………………………………………………………………………………………….. 7 6.3 Rated
voltage setting …………………………………………………………………………………………………………………………………… 8 6.4 Auto
Sleep Time Setting ……………………………………………………………………………………………………………………………….8 6.5 PAS
level setting ………………………………………………………………………………………………………………………………………… 9 6.6 Wheel
diameter setting …………………………………………………………………………………………………………………………………9 6.7 Number
of speed sensor magnets setting ………………………………………………………………………………………………………10 6.8
Speed limit setting ……………………………………………………………………………………………………………………………………..10 6.9
Start-up setting …………………………………………………………………………………………………………………………………………. 11 6.10
Drive mode setting ………………………………………………………………………………………………………………………………….. 11 6.11
Pedal assist sensitivity setting ……………………………………………………………………………………………………………………
12 6.12 Pedal assist strength setting
……………………………………………………………………………………………………………………….12 6.13 Number of pedal assist
sensor magnets setting …………………………………………………………………………………………… 13 6.14 Controller
Current Limit Setting ………………………………………………………………………………………………………………..13 6.15
Controller under voltage value setting
………………………………………………………………………………………………………..14 6.16 ODO reset operation
……………………………………………………………………………………………………………………………….. 14 6.17 Cruise enable
setting ……………………………………………………………………………………………………………………………….. 15 6.18 Promotion
function setting ………………………………………………………………………………………………………………………..15 7. Quality
Assurance and Warranty …………………………………………………………………………………………………………………………..16 7.1
Warranty info …………………………………………………………………………………………………………………………………………….16 7.2
Warranty does not cover ……………………………………………………………………………………………………………………………..16 8.
Wire connection diagram ……………………………………………………………………………………………………………………………………. 16
8.1 Standard wire connection sequence
…………………………………………………………………………………………………………….. 16 9. Precautions
……………………………………………………………………………………………………………………………………………………….. 16 Schedule 1:
Error Code Definition ……………………………………………………………………………………………………………………………17
Schedule 2: Error Code Definition
……………………………………………………………………………………………………………………………17
1. Product name and model number
Smart LCD display for electric bicycle; Model: 61F.
2. Specification
36V/48V power supply Display rated current 15mA Display maximum current 30mA
Shutdown leakage current <1uA Supplied current to the controller 50mA
Operating temperature -2060 Storage temperature -3070
3. Appearance and Size
Figure 3-1 Physical pictture of the YL61F display
Figure 3-2 YL61F Front View Dimension 2
Figure 3-3 YL61F Side View Dimension
4. Function overview and Functional areas
4.1 Functional overview The YL61F display offers a variety of features to suit
riding needs, including: Battery level indicator Pedal assist (PAS) level
indicator Speed (current speed, maximum speed, average speed) Mileage display
(single and total mileage) Walk boost mode Light ON/OFF Error code indicator
(optional) Cruise control indicator (optional) Bluetooth connection indicator
(optional) Personalized parameter settings (e.g. wheel diameter, speed limit,
battery power setting and PAS parameter setting,
password setting, controller current limit setting, etc.). Factory default
parameter recovery function
4.2 Functional areas
Battery level
Speed
PAS level Max speed Cruise control
Walk boost
Trip odometer Odometer
Figure 4-1 YL61F functional area distribution interface
Light ON/OFF
Speed unit Km/h MPH
Average speed
Mileage/speed unit MetricKmKm/h Imperial: MileMile/h
4.3 Button definitions The YL61F display is equipped with three buttons on the correctionding operating unit: power on/off
, plus
and minus .
5. Routine operation
5.1 Power on/off
Long press
to power on/off the display. When the display is off, it will not use the battery power and the leakage
current is less than 1uA. The display will automatically shut off if it is not used for more than 10 minutes.
3
5.2 Display interface switching When the display is powered on, it will show
the Current Speed (Km/h) and trip Odometer (km) by default. Short press
to switch between Trip Odometer (km), Odometer (km), Maximum Speed (km/h), and
Average Speed (km/h).
Trip Odometer
Odometer
Average Speed
Figure 5-1 Display Interface Switching
Maximum Speed
5.3 Walk boost mode Long press and hold
, the electric bicycle enters the walk boost mode. The electric bicycle will walk ata a fixed
speed of 6km per hour and the display shows the state before walk boost.
. Release the button to stop the power output immediately and restore to
Figure 5-2 Helping to implement the display screen
The walk boost mode can only be used when pushing the electric bicycle, please
do not use it while riding.
4
5.4 Turning on/off lights
Long press the
to make the controller turn on the lights and display backlight becomes dim. Long press
again to make the controller turn off the lights and the backlight restore brightness.
Figure 5-3 Backlight display interface
5.5 PAS level selection Press / to switch PAS level of electric bicycle, thus
changing the motor output power.
Figure 5-4 PAS level display interface
5.6 Battery level display The Battery level is shown as 5 bars. When the
battery is full charged, all of the 5 bars lighten up. When the battery is
fully depleted, the bar will begin to flash, warning the user to charge the
battery as soon as possible.
Full power
Four bars power Three bars power Two bars power One bar power Empty power flashing Figure 5-5 Battery Level Display Interface
5
5.7 Error code display If there is a fault occurs in the electric system of
the electric bicycle, the display will automatically show an error code,
see Schedule 1 for a detailed definition of the error code.
Figure 5-6 Error Code Display Interface
When the error code appears on the display, please troubleshoot the problem in
time, the electric bicycle will not be able to drive normally after the
problem occurs.
6. Personalized parameter settings
Each setting needs to be done with the bicycle stationary. The personalized
parameter setting procedure is as follows When the display is ON and the speed
shows 0, The following options are available on the personalized parameter
setting interface:
(1) Press and hold and simultaneously for more than 2 seconds to enter the personalized parameter setting interface.
(2) Press
/
to toggle between the personalized parameter setting interface, and press
parameter changing state.
to enter the
(3) Press / operation.
to select the parameter, long press
for addition operation, long press
for subtraction
(4) Press to save the parameter settings and return to the personalized parameter setting interface.
(5) Long press to save the parameter settings and exit the personalized parameter setting interface.
6
6.1 Backlight luminance setting 01P refers to the backlight luminance setting
option. The adjustable range is: 1-3, 01 for the minimum luminance, 02
for the standard luminance, 03 for the maximum luminance.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-1 Backlight luminance setting interface
6.2 Metric and Imperial setting 02P is the metric and imperial setting option,
00 for metric and 01 for imperial.
Press to enter the parameter changing state. Press the / to select the
parameter and press parameter setting and return to the personalized parameter
setting interface.
to save the
Metric display interface
Imperial display interface
Figure 6-2 Metric and Imperial Units Setting Interface
7
6.3 Rated voltage setting 03P is the rated voltage setting option. The
available rated voltage range is: 36V/48V.
Press to enter the parameter changing state. Press the / to select the
parameter and press parameter setting and return to the personalized parameter
setting interface.
to save the
Figure 6-3 Rated voltage setting interface
6.4 Auto Sleep Time Setting 04P is the auto sleep time setting. To save the
battery power and reach higher range, this dispaly will be turned off after
it has not been used for a time. The adjustable range is: 1~60min, 00 means no
auto shutdown. The factory default setting is 10 minutes.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-4 Auto Power Off Time Setting Interface 8
6.5 PAS level setting 05P is the Pedal assist (PAS) level setting option. The
available Pedal assist level settings are: 0~3, 1~3, 0~5, 1~5, The
factory default setting 0~5.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-5 PAS level setting interface
6.6 Wheel diameter setting 06P is the wheel diameter setting option. Unit: inch, accurace: 0.1, The adjustable wheel diameter range is: 0~50inch.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-6 Wheel diameter setting interface 9
6.7 Number of speed sensor magnets setting 07P is the speed sensor magnet
number setting option. The adjustable speed sensor magnet number range is:
01~255pcs.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-7 Number of speed sensor magnets setting interface
6.8 Speed limit setting 08P is the speed limit setting option. Change this
value to set the maximum riding speed of the electric vehicle; The
adjustable speed limit range is: 0~100km/h, 100 means no speed limit.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-8 Speed limit setting interface 10
6.9 Start-up setting 09P is the start-up setting option. The display can
choose the following start modes: 00 zero start, 01 non-zero
start.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-9 Start-up setting interface
6.10 Drive mode setting 10P is the drive mode setting option. The available
drive modes are: 00 Pedal assist only, 01 Electric only, 02
Both Pedal and assist electric.
Press
to enter the parameter changing state. Press the / to select the parameter and press
the parameter setting and return to the personalized parameter setting interface.
to save
Figure 6-10 Drive mode setting interface 11
6.11 Pedal assist sensitivity setting 11P is the pedal assist sensitivity
setting option. The adjustable range is: 1~24.
Press to enter the parameter changing state. Press the / to select the
parameter and press parameter setting and reyurn to the personalized parameter
setting interface.
to save the
Figure 6-11 Pedal assist sensitivity setting interface
6.12 Pedal assist strength setting 12P is the Pedal assist strength setting
option. The adjustable range is 0~5. 0 is the weakest strength and 5 is the
strongest.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and reyurn to the personalized parameter setting interface.
to save the
Figure 6-12 Pedal assist strength setting interface 12
6.13 Number of pedal assist sensor magnets setting 13P is the number of pedal assist sensor magnets setting option. The adjustable range: 5pcs, 8pcs,12pcs.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-13 Number of pedal assist sensor magnets setting interface
6.14 Controller Current Limit Setting 14P is the controller current limit setting option. The adjustable range is: 1~50Ah, The factory default setting is 12Ah.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-14 Controller Current limit setting interface 13
6.15 Controller under voltage value setting 15P is the controller under
voltage value setting option.
Press to enter the parameter changing state. Press the / to select the
parameter and press parameter setting and return to the personalized parameter
setting interface.
to save the
Figure Controller under voltage value setting interface
6.16 ODO reset operation 16P is the odometer reset setting option. Optional
- Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-16 ODO reset operation 14
6.17 Cruise enable setting 17P is the cruise enable setting option. 00 means disabled cruise, 01 means enable cruise, The factory default 00.
Press to enter the parameter changing state. Press the / to select the parameter and press parameter setting and return to the personalized parameter setting interface.
to save the
Figure 6-17 Cruise enable setting interface
6.18 Promotion function setting 18P is the promotion function setting option. 00 represents no 6km, 01 represents 6km. The factory default 00.
Press
to enable the parameter changing state. Press the / to select the parameter and press
the parameter setting and return to the personalized parameter setting interface interface.
to save
Figure 6-18 Promotion function setting interface 15
7. Quality Assurance and Warranty
7.1 Warranty info Yolin will offer a limited warranty for any failure caused
by the product defects under normal use during the
warrant period. The product is warranted for 12 months from the date out of
factory.
7.2 Warranty does not cover The shell is opened. The connector is damaged.
Scratches on the appearance after the product is out of factory. Scratched or
broken wires Failure or damage caused by force majeure (e.g. fire, earthquake,
etc.) or natural disaster (e.g. lightning strike, etc.) Out of warranty
period.
8. Wire connection diagram
8.1 Standard wire connection sequence
Controller connector
Display connector (Female terminal) Display connector (Male terminal) Figure 9-1 Wire Connection Diagram
Standard Wire Sequence 1 2 3 4 5
Table 9-1 Standard connector wire sequence table
Standard wire color
Function
Red (VCC)
Display power wire
Blue (Kp)
Controller power wire
Black (GND)
Display ground wire
Green (RX)
Display data reception wire
Yellow (TX)
Display data transmit wire
Some models are equipped with waterproof connectors and color inside wires can
not be seen.
9. Precautions
Pay attention to all the general operating when using the products and do not
plug and unplug the display while it is powered on.
Avoid bumping to all the general operating when using the products and do not
plug and unplug the display while it is powered on.
Please do not change the parameter settings at will, otherwise normal riding
cannot be guarantteed. If display does not work properly, please send it to
the repair center as soon as possible. There may be differences between the
physical products and this manual due to normal upgrade. Please refer to the
physical products.
16
Error code E001 E002 E003
Schedule 1: Error Code Definition
YL-01YL-02 Error codes
Definition
Error code
Definition
Controller failure
E004
Throttle failure
Communication failure
E005
Brake failure
Hall failure
E006
Motor phase failure
Error code Error05
Error06
Schedule 2: Error Code Definition
Customized YL-02LKLSError codes
Status significance
Processing method
Brake failure
Whether the brake is in position; Replace
the brake handle
Battery undervoltage
Requires battey charging
Error07
Motor fault
Check whether the power line is loose
Error08 Error09
Throttle failure Controller failure
Whether the handle is returned; Check the handle link. If it is normal, replace the handle Check the controller hall connection
Error10 Error11
Communication reception failure
Communication transmission failure
Check whether the instrument cable is connected properly
Check whether the instrument cable is connected properly
Tel: 022-86838795 Fax: 022-86838795 Email: yolin@yolintech.com Website:
www.yolintech.com Address: Tianjin Beichen District, Tianjin Beichen Economic
Development Zone, Medical Equipment Industrial Park, East of Jingfu Highway,
Ugu New Science Park 52-1 plant
17
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>