Product Name and Model Number
Smart LCD display for electric bicycle; Model: YL81F.
Specification
- 24V/36V/48V power supply
- Display rated current 15mA
- Display maximum current 30mA
- Shutdown leakage current <1uA
- Supplied current to the controller 50mA
- Operating temperature -20~60℃
- Storage temperature -30 to 70°C
Appearance and Size
Function Overview and Functional Areas
4.1 Functional overview
The YL81F display offers a variety of features to suit your riding needs,
including:
- Battery level indicator
- Pedal assist (PAS) level indicator
- Speed (current speed, maximum speed, average speed)
- Mileage display (single and total mileage)
- Walk boost mode
- Light ON/OFF
- Error code indicator
- Motor power indicator (optional)
- USB connection indicator (optional)
- Cruise control indicator (optional)
- Bluetooth connection indicator (optional)
- Personalized parameter settings (e.g. wheel diameter, speed limit, rated voltage, PAS parameter, password, and controller current limit setting, etc.).
- Factory default parameter recovery function
4.2 Functional areas
4.3 Button definitions
The YL81F display is equipped with five buttons on the corresponding operating
unit: power on/off , plus , minus , light and toggle .
Routine Operation
5.1 Power on/off
Long press to power on/off the display. When the display is off, it will not
use the battery power and the leakage current is less than 1uA.
The display will automatically shut off if it is not used for more than 10
minutes.
5.2 Display interface switching
When the display is powered on, it will show the Current Speed (km/h) and
Trip Odometer (km) by default. Short press to switch between Trip
Odometer(km), Odometer (km), Maximum Speed (km/h), and Average Speed (km/h).
5.3 Walk boost mode
Long Press and hold , the electric bicycle enters the walk boost mode. The
electric bicycle will walk at a fixed speed of 6 km/h and the display shows .
Release to stop the power output immediately and restore to the state before
walk boost.
The walk boost mode can only be used when pushing the electric bicycle, please
do not use it while riding.
5.4 Turning on/off lights
Press the to make the controller turn on the lights and the display
backlight becomes dim. Press again to make the controller turn off the lights
and the backlight restore brightness.
5.5 PAS level selection
Press / to switch PAS level of electric bicycle, thus changing the motor
output power.
5.6 Battery level display
The Battery level is shown as 5 bars. When the battery is full charged, all of
the 5 bars lighten up. When the battery is fully depleted, the bar will begin
to flash, warning the user to charge the battery as soon as possible.
5.7 Error code display
If there is a fault occurs in the electronic system of the electric bicycle,
the display will automatically show an error code, see Schedule 1 for a
detailed definition of the error code.
When the error code appears on the display, please troubleshoot the problem in
time, the electric bicycle will not be able to drive normally after the
problem occurs.
Personalized Parameter Settings
Each setting needs to be done with the bicycle stationary.
The personalized parameter setting procedure is as follows:
When the display is ON and the speed shows 0,
- Press and hold / simultaneously for more than 2 seconds to enter the personalized parameter setting interface.
- Press / to toggle between the personalized parameter setting interface, and press to enter the parameter changing state.
- Press / to select the parameter, long press for addition operation, long press for subtraction operation.
- Press to save the parameter settings and return to the personalized parameter setting interface.
- Long Press to save the parameter settings and exit the personalized parameter setting interface.
The following options are available on the personalized parameter setting
interface:
6.1 Metric and Imperial setting
01P is the metric and imperial setting, 00 for metric and 01 for imperial.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.2 Rated voltage setting
02P is the rated voltage setting. The available rated voltage range is: 24V,
36V, 48V.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.3 PAS level setting
03P is the Pedal assist level setting. The available PAS level settings are:
0~3, 1~3, 0~5, 1~5, 1~7, 0~7, 0~9, 1~9.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.3.1 PAS level ratio value setting
To meet different requirements for users, the speed of every level can be
adjusted by setting the PAS level ratio value.
Please see the details from Schedule 2.
For example, “45-55%” is the ratio range of PAS 1. The default ratio value of
PAS 1 is 50% which is adjustable.
Press the / to select the parameter and press to save the parameter and enter
into the next level setting.
Press again to save the settings and return to the personalized parameter
setting interface.
6.4 Wheel diameter setting
04P is the wheel diameter setting. The adjustable wheel diameter range is:
8~50inch.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.5 Number of speed sensor magnets setting
05P is the speed sensor magnet number setting. The adjustable speed sensor
magnet number range is: 1 ~ 15 pcs (5S protocol),1 ~ 63 pcs (KDS protocol).
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.6 Speed Limit Setting
06P is the speed limit setting. The adjustable speed limit range is: 1~60km/h
or 1~41km/h. (The maximum adjustable speed limit varies by different
protocols).
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.7 Controller Current Limit Setting
07P is the controller current limit setting. The adjustable range is: 1~31.5A.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
6.8 PAS sensor setting
08P is the PAS sensor setting.
6.8.1 PAS sensor direction setting
run is the PAS sensor direction setting. run-F is front direction and run-b is
opposite direction.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and enter into 6.8.2 PAS
sensor sensitivity setting interface.
6.8.2 PAS sensor sensitivity setting
SCN is the PAS sensor sensitivity setting. The adjustable range is: 2-9. 2 is
the highest level sensitivity while 9 is the lowest.
Press the / to select the parameter and press to save the parameter setting
and enter into 6.8.3 PAS magnets number setting interface.
6.8.3 Number of pedal assist sensor magnets setting
PAS is the pedal assist sensor magnets setting. The adjustable range is:
5-31.
Press the / to select the parameter and press to save the parameter setting
and to return to the personalized parameter setting interface.
6.9 Throttle setting
09P is the throttle setting.
6.9.1 Throttle 6KM/H walk boost setting
HL is the throttle 6KM/H walk boost setting. HL-Y is to enable the walk boost
and the speed will maintain at 6KM/H when using throttle. HL-Y is to disable
the walk boost and it can reach the max speed when using throttle.
Press the / to select the HL-Y and press to save the parameter setting and
return to the personalized parameter setting interface.
Press the / to select the HL-N and press to save the parameter setting and
enter into 6.9.2 Throttle Level setting interface or long press to return to
the personalized parameter setting interface.
6.9.2 Throttle level setting
HF is the throttle Level setting. HF-Y is to enable the throttle level. When
using the throttle, the max speed depends on the throttle level. (0~3, 1~3,
0~5, 1~5, 1~7, 0~7, 0~9, 1~9) HF-N is to disable the throttle level. The speed
is independent with the throttle level and can reach the rated max speed.
Press the / to select the parameter and press to save the parameter setting
and to return to the personalized parameter setting interface.
6.10 Power-on password setting
10P is the power-on password setting. The power-on password is not activated
by default but users can activate it from setting PSd-y. The factory default
password is 1212. Users can set other four-digit password. Please keep the
password in mind after changing it, otherwise you will not be able to use the
display.
Press to enter the parameter changing state. Press the / to select the
parameter. PSd-y means the power-on password is activated while PSd-n is off.
Press to confirm the mode and enter the state of setting the four digits
power-on password or exit to the personalized parameter setting interface.
Remember your password after changing it, or you will not be able to use the
meter!
In the password setting mode, the adjustable digit will flash. Press the / to select the parameter and press to save the numbers and go to the next digit setting. Long press to save the parameter setting and return to the personalized parameter setting interface after finish setting the four digits in turn.
6.11 Auto Sleep Time Setting
11P is the auto sleep time setting. To save the battery power and reach higher
range, this display will be turned off after it has not been used for a time.
The adjustable range is: 1~60min, 00 means no auto shutdown. The factory
default setting is 10 minutes.
Press to enter the parameter changing state. Press the / to select the
parameter and press to save the parameter setting and return to the
personalized parameter setting interface.
Shortcut Operation
7.1 Restore factory settings operation
dEF is the restore factory default parameter settings. dEF-Y is to restore
default settings, and dEF-N is not to restore.
Enter into the main setting interface and keep the speed at 0, press and hold
and simultaneously for 2s to enter the restore factory default setting
interface. Pressing / to toggle to dEF-Y. Then after pressing to confirm, the
display will show dEF-0 for a few seconds and then automatically start to
restore the factory default settings.
The display will automatically exit to setting interface after the
restoration.
7.2 Trip odometer reset operation
The display can record trip odometer and odometer. Trip odometer is not
automatically reset after turning off. The trip odometer needs to be reset
manually.
Enter into the main setting interface and keep the speed at 0, press and hold
and simultaneously for 2s to reset the trip odometer. The main interface will
flash during the reset process.
Quality Assurance and Warranty
8.1 Warranty info
- Yolin will offer a limited warranty for any failure caused by the product defects under normal use during the warranty period.
- The product is warranted for 12 months from the date out of factory.
8.2 Warranty does not cover
- The shell is opened.
- The connector is damaged.
- Scratches on the appearance after the product is out of factory.
- Scratched or broken wires
- Failure or damage caused by force majeure (e.g. fire, earthquake, etc.) or natural disaster (e.g. lightning strike, etc.)
- Out of warranty period.
Wire Connection Diagram
Standard wire connection sequence:
Table 9-1 Standard connector wire sequence table
Standard Wire Sequence | Standard wire color | Function |
---|---|---|
1 | Red (VCC) | Display power wire |
2 | Blue (Kp) | Controller power wire |
3 | Black (GND) | Display ground wire |
4 | Green (RX) | Display data reception wire |
5 | Yellow (TX) | Display data transmit wire |
■ Some models are equipped with waterproof connectors and the color inside wires can not be seen.
Precautions
Pay attention to all the general operating when using the products and do not plug and unplug the display while it is powered on.
- Avoid bumping the display as much as possible.
- Please do not change the parameter settings at will, otherwise normal riding cannot be guaranteed.
- If display does not work properly, please send it to the repair center as soon as possible.
- There may be differences between the physical products and this manual due to normal upgrade. Please refer to the physical products.
Schedule 1: Error Code Definition
YL-01, YL-02 Error codes
Error code | Definition |
---|---|
E001 | Controller failure |
E002 | Communication failure |
E003 | Hall failure |
E004 | Throttle failure |
E005 | Brake failure |
E006 | Motor phase failure |
YL-05, KDS, YL-J Error codes
Error code | Definition |
---|---|
E021 | Current failure |
E022 | Throttle failure |
E023 | Motor phase failure |
E024 | Hall failure |
E025 | Brake failure |
E030 | Communication failure |
Schedule 2: Pedal Assist Level Default Ratio Value
Level ⇒
Level selection ⇓| 1| 2| 3| 4| 5| 6| 7| 8| 9
---|---|---|---|---|---|---|---|---|---
0-3/1-3| 50%| 74%| 92%| –| –| –| –| –| –
0-5/ 1-5| 50%| 61%| 73%| 85%| 96%| –| –| –| –
0-7/ 1-7| 40%| 50%| 60%| 70%| 80%| 90%| 96%| –| –
0-9/ 1-9| 25%| 34%| 43%| 52%| 61%| 70%| 79%| 88%| 96%
Tel: 022-86838795
Fax: 022-86838795
Email:store@yolintech.com
Website:www.yolintech.com
Address: Plant 52-1, Yougu Xinke Park, East of Jingfu Road,
Pharmaceuticals and Medical Equipment Industrial Park, Beichen