wavewear ES111 ElecSuit E-Haptic Suit User Manual

June 14, 2024
wavewear

wavewear ES111 ElecSuit E-Haptic Suit

Manufacturer

  • A. Legal Manufacturer’s Name
    WAVE COMPANY Ltd.

  • B. Legal Manufacturer’s Address
    B-#716 DMC Hi-Tech Industry Center, 330, Seongam-ro, Mapo-gu, Seoul, Korea
    Postcode: 03920

  • C. Storage and Manufacturing
    B-#716 DMC Hi-Tech Industry Center, 330, Seongam-ro, Mapo-gu, Seoul, Korea
    Postcode: 03920

  • D. Tel number
    +82-70-4044-7331

  • E. Regulatory representative
    Mr. Sang Chul Lee

  • F. Certificates of Manufacturer
    i. Business registration

  • G. Company History
    2010 Establishment of Odoroso Co., Ltd.
    2017 Company name changed to Wave Company Co., Ltd.
    2015 Started development of adhesive silicone coated sportswear
    2017 Started development of conductive silicone coated sportswear
    2018 Official launch of adhesive silicone coated sportswear (Wavewear)
    2021 Selected as Mass Challenge finalist
    2022 Selected for attracting investment from Stadia VC

Product Name
ElecSuit: e-Haptic Suit for EMS Workout & VR Games

Mechanism
A low-frequency electrical stimulator sends microcurrents in a specific pattern into the body through electrodes attached to the skin for providing the user with a virtual sense of touch.

Product List

  1. Elec Suit
  2. Controller
    • 2ch e-stim Device
    • Cables
  3. Software

Elec Suit

  • A. Product Name
    Elec Suit

  • B. Material Brand Name
    Elecsil A
    Elecsil B

  • C. Model List
    No| Brand name| Color| Type| Model Name| Model Code
    ---|---|---|---|---|---
    1| ****










Elec Suit

| Black| Top| Standard Sleeveless Top| ES111
2| Bottom| Standard Shorts| ES211
3| Top| PRO   Short Sleeve Top| ES112
4| Bottom| PRO Shorts| ES212

  • D. Picture of the product
    Blue indicates the location of the electrode, which is actually black
    Front Side(Left), Back Side(Right)

wavewear ES111 ElecSuit E-Haptic Suit 1

  1. Brand name
    • Elec Suit (ES)
  2. Type
  3. Top
  4. Bottom
  5. Color
    • Black
  6. Model
  7. 2021 Standard
  8. 2022 PRO
  9. Size
    • XS. XSmall
    • S. Small
    • M. Medium
    • L. Large
    • XL. Xlarge
    • XXL. XXlarge

F. Electrode Structure of Elec Suit

  1. Fabric

    • Spandex Fabric
    • Elastic in all directions
  2. Elecsil A

    • Coating Thickness: less than 0.3mm
    • Coating on Fabric
    • Stretchable and Low Resistance
    • Performs the function of reducing resistance for the coated electrode
  3. Elecsil B (Black)

    • Coating Thickness: less than 0.3mm
    • Coating on Elecsil A, contacting on skin
    • Stretchable, Adhesiveness and Harmless to human body
    • Pass cytotoxicity test(ISO 10993-5), Skin irritation, Skin sensitization(ISO 10993-10)
    • Performs the function of electrical conduction between coated electrode and skin

wavewear ES111 ElecSuit E-Haptic Suit 5

  1. Parts
    No.| Part name| Description
    ---|---|---
    1| M agnetic

button

| Electrically connects the device and conductive silicon

by using magnetic force of button.

2| Non stretchable

film

|

It removes elastic to prevent buttons from detaching.

3| Insulating film| An insulating film is attached to the opposite side of

the magnetic button that touches the skin for preventing unwanted electric conduction to skin.

wavewear ES111 ElecSuit E-Haptic Suit 6

G. Usage

  1. Electrical Stimulation for Haptic
    Realization of virtual tactile sensation through electrical stimulation

  2. EMS training
    During exercise, electrical stimulation is provided to the muscles to maximize contraction and relaxation, allowing for high-intensity exercise in a short period of time.

H. Performance

  1. Elecsil A
    7 * 7 cm size coating sample. Initial distance: 5cm
    Strain to 10% or 100% and then after waiting 2 sec, release to 0% and then waiting 2 sec. during repeating this cycle, measuring resistance.
  • 10% 100 times strain-release (Unit : Ω)
    Initial Resistance 0.028Ω| 1 time 100%| 1 time 0%| 50 times 100%| 50 times 0%
    ---|---|---|---|---
    Immediately

after strain or release

| 0.105| 0.077| 0.403| 0.239
After  waiting

2 sec

| 0.096| 0.098| 0.363| 0.201

  • 100% 50 times strain-release (Unit: Ω)
    Initial Resistance 0.028Ω| 1 time 100%| 1 time 0%| 50 times 100%| 50 times 0%
    ---|---|---|---|---
    Immediately

after strain or release

| 8.036| 0.807| 26.806| 0.889
After  waiting

2 sec

| 7.796| 0.657| 19.843| 0.741

ii. Elecsil B

wavewear ES111 ElecSuit E-Haptic Suit 7

  • Stretchability
    Elecsil B on Elecsil A
    There is no damage even when pulled at 100% strain.

  • Measuring Impedance
    Wearing the PRO top and then measureing impedance to a pair of abdominal electrodes
    Impedance, 100Hz (Unit: Ω)Contact on original skin| Contact on wet skin
    ---|---
    5.8k| 3.2k

  • Washing durability
    No damage for an appearance after 30 times machine wash
    Impedance for skin contact (unit: Ω)Before wash| After wash
    ---|---
    5.28k| 5.8k

Controller

A. Appearance

  1. 2ch e-stim Device
    • Description of an appearance

wavewear ES111 ElecSuit E-Haptic Suit 8

No. Name Description
RGB LED Displays the status of the device.

Color can be controlled during wireless control.

| + Button| Above the side button

Increases the voltage level in manual mode.

| Button| Below the side button

Lowers the voltage level in manual mode.

Press and hold the + and – buttons together to enter Bluetooth pairing mode.

| Power Button| Control power on/off by pressing and holding for about 2 seconds.

In manual mode, you can change the electrical stimulation channel by quickly pressing and releasing the button when the voltage intensity is one level or

higher.

| Battery indicator

LED

| Lights up in red when the battery is charging.

When fully charged, it lights up in green.

| Electrical stimulation AUX Socket| AUX jack (F) type terminal that outputs electrical stimulation

Based on the TOP, there is 1 channel on the left and 2

channels on the right.

| C type     charging

terminal

| Terminal area for charging
---|---|---

  • RGB LED
    No.| Color| Description
    ---|---|---
    1| White| The power is turned on and entered manual mode
    2| Green flicker once| Press the side button to display voltage level control
    3| Purple flicker once| Quickly press and release the power button to display

the electrical stimulation channel change

4| Blue flicker once| Bluetooth pairing status
5| Blue  green  flicker

once

| Bluetooth connected status
2. Cables

  • Plug the AUX jack into the electrical stimulation AUX terminal
  • Connect the magnetic terminal on the other side to the ElecSuit.

wavewear ES111 ElecSuit E-Haptic Suit 9

B. specification

  1. Basic specification
    1. Model Name| 2ch MV2

(Firmware: WaveEnhanced_v3.0 0516)

---|---
2. Rated voltage| 3.7Vdc
3. Power| Li-Po Battery, 240mAh
4. Size| about 45 65 14 mm (DLH)
5. Weight| about 26g
6. Case material| Polycarbonate
7. Usable time| Recommended within 15 minutes for one-time use
8. Channels| 2 channels (4 pads)
9. Maximum voltage (500Ω)| about 55.5V (Based on manual mode)
10. Bluetooth| BLE, 4 multi-point linkages possible
11. minimum

command interval

| More than 100ms
12. Mode| 1)  Manual mode

EMS output of power by pressing buttons

2)  Bluetooth mode

–  EMS mode (Repeatedly output of power)

–  Haptic mode(Cycle 1 output of power)

  1. Manual mode specification****
    1. Stimulation Level| Lv. 1~15
    ---|---
    2. Width of pulse| 200 us 2 pulses biphasic wave
    3. Number of pulses per

pick

| 1.25kHz interval biphasic wave 3 pairs pulse
4. Frequency| about 30 Hz
5. Cycle Width| 3s
6. Cycle interval| 1s
7. Control of channel| Channel 1 and 2 can be changed by clicking the power button
8. Wave Slope| Gradually increase voltage intensity (at the beginning of cycle)

  • Manual mode stimulation intensity at each stage
    Only 1ch 500Ω load (no connected 2ch)
    1ch voltageLv| Voltage(V)| Lv| Voltage(V)| Lv| Voltage(V)
    ---|---|---|---|---|---
    1| 12.5| 6| 28.1| 11| 44.6
    2| 14.9| 7| 31.4| 12| 47.4
    3| 18.1| 8| 35.0| 13| 50.3
    4| 22.1| 9| 38.2| 14| 52.7
    5| 25.3| 10| 41| 15| 55.5
  1. Control elements of Bluetooth mode
    1. Width of pulse| 100, 200, 400 us
    ---|---
    2. Number of pulses per pick| 1~5 pairs
    3. Frequency| 1~500Hz(Width of pulse 100us), 1~250Hz(Width of pulse 200us)

1~125Hz(Width of pulse 400us)

4. Cycle Width| 1.0~10.0s, 0.1s unit control

Infinite operation possible without stopping cycle

5. Cycle interval| 1.0~10.0s, 0.1s unit control (EMS mode)
6. Control of channel| Controllable with 6 patterns

Controlled by pair of channels 1 and 2 (2 types) PAD 1,2,3,4 independent stimulation (4 types)

7. Wave Slope| Tilt adjustment at the beginning of cycle
8. stimulation intensity| 1~1971
9. RGB| RGB LED in the Device

R 0~255, G 0~255, B 0~255

  • Control elements picture Overall view

wavewear ES111 ElecSuit E-Haptic Suit 10

  • Bluetooth mode electrical stimulation intensity Voltage intensity varies depending on the number of picks, pulse width, and frequency. Fix the number of picks to 3 and pulse width to 200us and adjust only the frequency and voltage intensity variables. Voltage intensity based on load 500Ω.
    | 30Hz| 60Hz| 100Hz
    ---|---|---|---
    Minimum Voltage(V)| 12.5| 9.6| 8
    Maximum Voltage(V)| 57.1| 41| 32.2

wavewear ES111 ElecSuit E-Haptic Suit 11

Software

  • Wireless control using command control method

wavewear ES111 ElecSuit E-Haptic Suit 12

FCC

FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 5 mm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Read User Manual Online (PDF format)