First, compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
12 x B1| 2100 x 45 x 18 mm| ID 19547
4 x B2| 2790 x 60 x 40 mm| ID 28251
1 x X4| 1475 x 38 x 38 mm| ID 44840
2 x X2| 1724 x 38 x 38 mm| ID 43522
18 x C1| 150 x 140 x 26 mm| ID 63591
9 x C2| 2744 x 140 x 26 mm| ID 35966
2 x C3| 1590 x 190 x 26 mm| ID 8244
2 x C4| 3300 x 190 x 26 mm| ID 12391
2 x G1| 2970 x 212 x 38 mm| ID 78729
1 x H1| | ID 77301
2 x K1| 440 x 58 x 28 mm| ID 79765
2 x K2| 850 x 58 x 28 mm| ID 79766
2 x Y1| | ID 22599
2 x W1| 2970 x 71 x 38 mm| ID 35643
54 x W2| 2970 x 121 x 38 mm| ID 29489
32 x W3| 743 x 121 x 38 mm| ID 61757
36 x R1| 3300 x 96 x 16 mm| ID 69917
50 x| 4 x 30 mm| ID 3686
90 x| 4 x 35 mm| ID 3687
140 x| 4 x 50 mm| ID 3688
30 x| 4 x 70 mm| ID 3689
10 x| 4,5 x 80 mm| ID 9204
80 x| 4 x 70 mm| ID 39352
370 x| | ID 5621
6 x| | ID 21292
Overview
***** Not included
Length must be determined and sawn
**Cut-outs for screw connections
**
Wood is subject to a natural process of swelling and contraction. For this
reason, over the course of the year your house “grows” and “shrinks”. Shorter
wooden boards (front) adapt faster than longboards to momentary climatic
conditions. This can result in cracking. In order to reduce this cracking and
at the same time allow for the natural growth and shrinkage behavior of the
wood, at the window and door recesses you must join every two boards
positioned directly over each other. For this purpose, use 4 x 60 Spax joints.
Always pre-drill the boards for the screw can drill obliquely into the wood
without slipping connections.
Note You away by setting on the drill vertically for the first 3-5 mm and
only then drilling obliquely.
Dear customer, pay attention to the correct design variant!
|
---|---
|
|
|
Roofing felt installation
Note! This description is only an example!
The bitumen roofing is used for the initial cover and should be supplemented
by a separate product according to customers’ choice after two months. The
number of bitumen strips to be used depends on your actual house size. When
joining rolls of roofing felt end to end, the overlap must be approximately
10cm. The roof is not safe to walk on. The roof is designed for a total load
(snow, wind) and not for a point load. We recommend you always support the
roof from below during installation. The sealing of the roof surfaces to
adjacent components with bitumen sealant has to be affected by the customer!
If it is a saddle-roofed house, do not use roofing tiles for roofing. In this
case, a 20 cm wide strip of bitumen with an overhang should be installed on
both sides of the eaves. For houses with a tonne roof, please install bitumen
roofing under the shingles. In the case of a flat roof, the laying of roof
shingles is not possible!
*** Not included! Protect from moisture!**
|
---|---
|
91989
Building Instructions
First, compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
6 x F1| 2100 x 45 x 18 mm| ID 19547
4 x F2| 1865 x 140 x 26 mm| ID 64828
2 x F3| 2005 x 140 x 26 mm| ID 64827
1 x F4| 2330 x 140 x 26 mm| ID 67969
2 x F5| 2610 x 140 x 26 mm| ID 15537
15 x F6| 4143 x 140 x 26 mm| ID 73853
1 x F7| 4000 x 190 x 26 mm| ID 73855
46 x R1| 3300 x 96 x 19 mm| ID 19571
80 x| 4 x 25 mm| ID 5841
30 x| 4 x 30 mm| ID 3686
10 x| 4 x 50 mm| ID 3688
300 x| 4 x 70 mm| ID 3689
470 x| | ID 5621
10 x| | ID 14041
Overview
Length must be determined and sawn
|
---|---
|
**Mounting roof
**
Roofing felt installation
Note! This description is only an example!
The bitumen roofing is used for the initial cover and should be supplemented
by a separate product according to customers’ choice after two months. The
number of bitumen strips to be used depends on your actual house size. When
joining rolls of roofing felt end to end, the overlap must be approximately
10cm. The roof is not safe to walk on. The roof is designed for a total load
(snow, wind) and not for a point load. We recommend you always support the
roof from below during installation. The sealing of the roof surfaces to
adjacent components with bitumen sealant has to be affected by the customer!
If it is a saddle-roofed house, do not use roofing tiles for roofing. In this
case, a 20 cm wide strip of bitumen with an overhang should be installed on
both sides of the eaves. For houses with a tonne roof, please install bitumen
roofing under the shingles. In the case of a flat roof, the laying of roof
shingles is not possible!
***** Not included! Protect from moisture!
**82314 82315**
First, compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
1 x D1| 1765 x 705 x 36 mm| ID 67826
1 x D2| 1765 x 705 x 36 mm| ID 67827
1 x X1| 1400 x 28 x 18 mm| ID 68619
5 x X2| 1834 x 45 x 18 mm| ID 82077
2 x X3| 1428 x 95 x 18 mm| ID 82078
1 x X4| 1475 x 38 x 28 mm| ID 34189
2 x X5| 1724 x 38 x 28 mm| ID 34188
1 x| | ID 22725
40 x| 4 x 30 mm| ID 3686
20 x| 4 x 40 mm| ID 21925
20 x| 4 x 50 mm| ID 3688
2 x| | 3709
6 x| | ID 3717
1 x| | ID 68586
Dear customer, pay attention to the correct design variant!
System House
Log cabin At 40 mm houses Bars are in the house package At 40 mm houses Bars are in the house package Remove protective film
|
---|---
|
|
**At 40 mm houses Bars are in the house package At 40 mm houses Bars are in the house package Remove protective film**
|
---|---
|
|
Handling/Maintenance/Care of the door
The guarantee is conditional on proper upkeep!
For lasting protection of the value and suitability for use, professional care
and maintenance are also recommended during the warranty period; this is not
included in the warranty obligations. Defects must be repaired immediately
upon detection.
Wood protection treatment of the door
All parts of the door must receive wood protection treatment. Those sections
of the wood, which will not be accessible after installation, should receive
complete treatment before installation.
Treat the product with a blue stain-blocking coat; afterward, apply a double
protective coating of an open-pored wood-protection glaze. The application of
a protective coating should be repeated at least every two years.
Please beware that the inserted plates of other material may come to differ in
color from the doors if you use unsuitable coating material. With colored and
boiler pressure-impregnated houses, only the exposed natural wood (saw cuts)
and parts should need extra treatment.
You can obtain an even color covering in inside areas with one coat of paint.
For that, you should use an open-pored, acrylic-based water-dispersed lacquer.
In order to guarantee a long service life for your product, you should repair
damaged areas immediately. Do this by whetting the damaged area and applying a
new coat of paint. Enquire about suitable glazes at your local paint retailer.
Furthermore, you can seal the joining of the wood-window pane with a suitable
sealant to guarantee a long service life of the door and prevent leakage from
heavy rain. If these precautions of care are not properly carried out, it can
result in deformation, blue stain, fungus infestation in the doors and frames,
and loss of warranty.
Cleaning
Regular cleaning and care is a prerequisite for preserving the service life
and functionality of high-value products. Cleaning is to take place outside,
inside, and also in the rabbeted area. The cleaning agent used must be
suitable for the relevant material; please do a test before you start
cleaning.
Deformation of the door
Wood reacts to environmental influences. Weather exposure will lead to swelling
and contraction of the wood. This causes variances of dimensions and slight
deformation. Depending on the weather exposure, the door may need realignment
by turning the hinges in or outwards. Some door warpage is acceptable as long
as the door can be made to function through the alignment options specifi ed
here. The warranty does not cover damage caused by the use of excessive force.
Adjustment of the door
The door must be accurately adjusted to ensure trouble-free operation. The
door frames must be installed right-angled and perpendicular. Furthermore,
they must be installed so the width of the frame is the same at the top and
bottom. If the door doesn’t close or if one panel is askew, this can be rectifi
ed by limited in- or outward turning of the hinges. You can turn the hinges
outwards up to 5 rotations. If you have a double door, the door to be secured
must always be correctly aligned at the top and bottom with the appropriate
hinges.
**7825**
https://www.karibu-farbenshop.de/
First, compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
18 x A1| 2540 x 121 x 28 mm| ID 42329
2 x Z1| 2100 x 95 x 18 mm| ID 11427
2 x Z2| 2100 x 120 x 18 mm| ID 65102
1 x Z3| 2345 x 60 x 40 mm| ID 39752
40 x| 4 x 30 mm| ID 3686
70 x| 4 x 50 mm| ID 3688
5 x| 4 x 70 mm| ID 3689
***** Not included
Overview
Length must be determined and sawn
|
---|---
|
|
**7823**
https://www.karibu-farbenshop.de/
First, compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
18 x A1| 4000 x 121 x 38 mm| ID 66796
2 x Z1| 2100 x 45 x 18 mm| ID 19547
2 x Z2| 2100 x 95 x 18 mm| ID 11427
3 x Z3| 1980 x 58 x 28 mm| ID 39800
1 x Z4| 3990 x 60 x 40 mm| ID 28695
20 x| 4 x 25 mm| ID 5841
30 x| 4 x 30 mm| ID 3686
150 x| 4 x 50 mm| ID 3688
4 x| 4 x 70 mm| ID 3689
4 x| 4 x 25 mm| ID 71185
4 x| 80 x 20 x 20 mm| ID 71184
***** Not included
Overview
- Length must be determined and sawn****
|
---|---
|
|
|
Karibu Holztechnik GmbH
Eduard-Suling-Str. 17
28217 Bremen
info@karibu.de
+49 421 38693 33
Read User Manual Online (PDF format)