Star BSH-32B Wireless Barcode Scanner User Guide

June 14, 2024
Star

Star BSH-32B Wireless Barcode Scanner User Guide
Star BSH-32B Wireless Barcode Scanner

Scanner

Scanner

Red LED flashes – Low battery alert
Red LED on Charging
Blue LED flashes slowly – Disconnected
Blue LED flashes quickly – Batch data transmission
Green LED on Full charged
Green LED flashes once – Good read

Cradle (Horizontal Mount)

The scanner and the cradle are paired before shipping Before pairing other scanners, disconnect or power off the paired scanner and scan the pairing barcode in the cradle. Replug the data cable in Bluetooth Dongle. mode.

Connecting the Cradle to the Host with USB Cable

Connecting

Note: The power jack and data port are located at the bottom of cradle as shown below.

Cradle – Vertical Mount

Cradle - Vertical Mount
Cradle - Vertical Mount

Cradle-Wall Mount & Battery Maintenance

Install the two plastic wall anchors in a wall and use screws to secure the plate to the wall with its A side facing the wall. Slide the vertical cradle onto the plate

  1. Replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types).
  2. Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion.
  3. Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas.
  4. A battery subjected to extremely low air pressure that may result in an explosion or the leakage off flammable liquid or gas.
  5. Risk of fire or explosion if the battery is replaced by an incorrect type.

Barcode Programming

Note: Asterisks (**) indicate factory default values.

Enter/Exit Setup

Enter Setup
Barcode Programming

**Exit Setup
Barcode Programming

Factory Defaults

Reset Scanner
Barcode Programming

Reset Cradle
Barcode Programming

Batch Mode

Off
Barcode Programming

Automatic Batch Mode
Barcode Programming

Manual Batch Model
Barcode Programming

  1. Windows7 and the below version doesn’t support Bluetooth HID.
  2. Insert USB cable of the cradle and scan Enter Setup barcode before changing setting. Scan the Exit Setup barcode after all changes are made,
  3. Pairing: Turn on Bluetooth in the host and search BSH32-XXXXXXX(the last 7 letters of the S/N number), click connected. Beep and blue LED on indicate the connection success.
  4. Pull out the USB cable before switching from Bluetooth Dongle to Bluetooth Mode.

Bluetooth Mode

Bluetooth HID

Bluetooth BLE

Bluetooth Dongle

**Bluetooth Dongle KBW
Barcode Programming

Bluetooth Dongle HID POS
Barcode Programming

Bluetooth Dongle CDC
Barcode Programming

Power off scanner

Power Off Scanner

NOTE: WHEN USING THE SCANNER FOR THE FIRST TIME, YOU MUST INSERT THE SCANNER IN A POWERED CRADLE TO EXIT BATTERY PROTECTION MODE BEFORE TURNING IT ON

UKCA/NOM

  1. Bluetooth:
    Maximum RF power: 6dBm. frequency range: 2402-2480MHz

  2. We hereby declares that this device is in compliance with the essential requirements and other relevant provisions of Radio Equipment Regulations 2017.

  3. The full test of the UK declaration of conformity is available at the following internet address: www.starmicronics.com

FCC

Radio Frequency Interference Requirements Radio Transmitters (Part 15)

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Tested to comply with FCC Standards

FOR HOME OR OFFICE USE

FCCID:SL9BSH-32B

Note

This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

FCC/IC

Note:
Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate theequipment.

CE/WEEE

Marking and European Economic Area (EEA) Statement of Compliance

We hereby declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc.;

This product max operating ambient temperate is 40 degree C.

Direct Current Symbol

RECYCLING:

This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE).
This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment

IC

IC Statement

This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The device is compliance with RF field strength limits, users can obtain Canadian information on RF exposure and compliance.

This Class B digital apparatus complies with Canadian ICES-003.

Troubleshooting

When the scanner is not working, please:

  1. Check for loose cable connections. Make sure only supplied cables are used and all cable connections are secure.
  2. Ensure the barcode is not defaced. Wrinkled, soiled or torn barcodes might be unreadable. Try scanning the known readable barcode to verify the reading function of the scanner.
  3. Find out the barcode type and ensure the barcode type is enabled.
  4. Ensure the cradle is programmed for the correct host interface.
  5. Ensure the scanner is paired to the cradle.
  6. If the problem still persists, please contact your dealer or Star Micronics.

More Information

For more information about BSH-32B BLK, please visit the Star website at www.starmicronics.com

Star logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Star User Manuals

Related Manuals