amiciSmart 220V Under Voltage and Over Load Protection User Manual

June 14, 2024
amiciSmart

AMICI-SMART-LOGO

amiciSmart 220V Under Voltage and Over Load Protection

Product Information

Application
The product is designed to protect single-phase lines from over-voltage, under-voltage, and over-current faults. It can automatically power off the line in case of a fault and restore the connection after a time delay when the voltage or current returns to normal. It also provides protection against transient over-voltage and can disconnect the line in case of unstable voltage, sudden power-off, or power-on due to faults.

Product Features

  • Automatic restoration of line connection after voltage or current recovery
  • Protection against false operation caused by transient over-voltage
  • Disconnection of the line in case of unstable voltage or faults
  • No damage to the product itself even at peak fault voltage

Normal Use and Installation Conditions

Normal Use Conditions

  • Ambient air temperature: No specific range is provided
  • Altitude: Installation place should not exceed 2000m
  • Atmospheric conditions:
    • Humidity: No specific range is provided
    • Class of pollution: 3

Installation Conditions

  • The protector can be vertically or horizontally mounted in a cabinet. Special orders may be required for specific mounting requirements.
  • The protector should be mounted in a medium without the risk of explosion. The medium should not contain gas or conductive dust that can corrode metal or affect insulation.
  • The protector should be mounted in a place that is not invaded by rain or snow.

Error Description

Error Code:

  • H: Supply/Grid Voltage is higher than the specified voltage in the device.
  • U: Supply/Grid Voltage is lower than the specified voltage in the device.
  • L: The load Current is higher than the specified current in the device.

Product Setting
The product has various settings that can be adjusted. Below are some of the available settings:

  • Voltage display: Default value is 230V
  • Current display: Default value is 63.0A
  • Power-on delay time: Default value is 1S
  • Over-voltage protection value: The default range is 230-300V
  • Over-voltage recovery value: The default range is 225-295V
  • Over-voltage recovery delay time: Default range is 1-500S
  • Over-voltage protection action time: Default range is 0.1-30S
  • Under-voltage protection value: The default range is 140-210V
  • Under-voltage recovery value: The default range is 145-215V
  • Under-voltage recovery delay time: Default range is 1-500S
  • Under-voltage protection action time: Default range is 230-300S
  • Over-current protection value: The default range is 1-63A
  • Over-current recovery delay time: Default range is 1-500S
  • Over-current protection action time: Default range is 0.1-500S
  • Voltage calibration
  • Continuous over current faults times: Default range is 1-20
  • Current calibration

To exit from the settings, press SET. The manual switch can be used to turn off the protection function. The settings can be changed using the arrow keys. Pressing the key for more than 12 seconds will restore the factory settings, and pressing the key for more than 6 seconds will allow querying the latest fault.

Main Technical Parameters

Function Technical Parameter
Input voltage AC 140-300V
Over-voltage protection value 230-300V (default 270V)
Under-voltage protection value 140-210V (default 170V)
Over-current protection value 1-63A (default 40A)
Recovery delay time 1-500s (default 30S)
Continuous over current faults times 1-20
Power consumption 2W
Boundary dimension 86 x 38 x 68MM
Function Power-on delay time 1-500s (default 10s)
Over-voltage recovery value 225-295V (default 265V)

Product Usage Instructions

To use the product:

  1. Ensure that the product is installed in accordance with the installation conditions mentioned in the user manual.
  2. Set the desired values for the various parameters using the product settings. Refer to the user manual for details on each setting.
  3. To change a setting value, use the arrow keys to navigate to the desired setting and press the key.
  4. To restore the factory settings, press and hold the key for more than 12 seconds.
  5. To query the latest fault, press and hold the key for more than 6 seconds.
  6. To turn off the protection function, press the manual switch key.

Application
Over Voltage and Voltage Protective Device with Auto-Reclosing Function (OUPA) is an intelligent protector integrated with an over-voltage protector, under-voltage protector, and over-current protector. In case of over-voltage fault, under-voltage fault, and over-current fault in line, this product can instantly power off to prevent electrical equipment from being burnt. The over-voltage, under-voltage, and over-current values of this product can all be set up by yourself and can be adjusted based on local practical conditions.

Product Features

  • In case of over-voltage fault, under-voltage fault, and over-current fault in single phase line, the product can power off the line and can automatically restore connecting the line over a time delay after the voltage or current of the line is recovered to normal condition.
  • In case of transient overvoltage in line, the product can protect the equipment from false operation.
  • In case the line is subject to unstable Voltage or sudden power-off and power-on due to a loosened connection and another fault, the product will disconnect the line.
  • When the fault voltage of the line reaches the peak, the product itself will not be damaged.

Normal use and installation conditions

Normal use conditions

Ambient air temperature
Ambient air temperature shall not be more than +55°C and not less than -20°C and the 24H average temperature shall not be more than +35°C.

Altitude
The altitude of the installation place shall not exceed 2000m.

Atmospheric conditions

Humidity
The relative air humidity at the installation place shall not be more than 50% when the ambient air temperature is +40°C; Relative humidity may be high under low-temperature conditions. For instance, when the mean minimum temperature in the wettest month is +20°C, the mean maximum relative humidity in the month may reach 90%. Condensation produced due to temperature change shall be prevented by taking appropriate measures.

  • 2 Class of pollution: 3
  • Installation conditions
  • Protector can be vertically or horizontally mounted in the cabinet. If specially required, it is necessary to make a special order.
  • Protector shall be mounted in medium without risk of explosion. In the medium, there shall be no gas and conductive dust which are sufficient to corrode metal and affect insulation effect.
  • Protector shall be mounted in a place that may not be invaded by rain and snow.

Error Description:

Error Code Reason
H U Supply/Grid Voltage is higher than the specified voltage in the device.
L U Supply/Grid Voltage is lower than the specified voltage in the device.
H A The load Current is higher than the specified current in the device.

Product setting:amiciSmart-220V-Under-Voltage-and-Over-Load-Protection-
FIG- \(1\)

  1. Change the setting value by pressing the keys.
  2. Press the key for more than 12 seconds to restore the factory settings.
  3. Press the key for more than 6 seconds to query the latest fault.

Main technical parameters

Function| Technical Parameter| Function| Technical Parameter
---|---|---|---
Input voltage| AC 140-300V| Power-on delay time| 1-500s default 10s
Over-voltage protection value| 230-300V default 270V| Over-voltage recovery value| 225-295V default 265V
Under-voltage protection value| 140-210V default 170V| Under-voltage recovery value| 145-215V default 175V
Over-current protection value| 63A:1-63A default 40A|  |
Recovery delay time| 1-500s default 30S| Action time| 0.1-30s default 1s
Continuous over current faults times| 1-20 times default OFF
Power consumption| ≤2W| Electrical and mechanical life| ≥100000cycles
Boundary dimension| 86 x 38 x 68MM| Wiring| Over-entering down-out

Usage
After being installed, the protector can be wired by the user. Wherein, a cross-section of the wire shall be selected by the standard applicable and based on the rated current of the protector. Pay attention to the locations of incoming and outgoing wires and the phase sequence before powering them on for use.

Notes

  • The user shall follow relevant procedures and pay attention to the following items when carrying out various operations or tests to ensure the correct and safe use of the product
  • The input and output shall be corrected and connected based on the product marking. (Wherein, the load current shall be less than the protective current of the product.)
  • Neutral line N cannot be improperly connected and shall be reliably wired; otherwise, the protector may not work normally.
  • Before powering on, please carefully check whether the wiring is correct, whether the load matches the protective current of the product, and whether the binding screw is tightened; otherwise, the product may be damaged.
  • After powering on the product, do not touch any live part to avoid electric shock.
  • This product shall be combined with micro circuit breaker to play the role of short-circuit protection; otherwise, the product may not be able to realize load limit protection in case the input or load end of the product appears short circuit.
  • As the product has an automatic reset function after the product plays the role of protection and acts, it is necessary to remove the load (electric appliance) and check the circuit; otherwise, the product will be frequently connected and disconnected from the load. Finally, the product or its circuit may be burnt due to frequent overload connection and disconnection for a long time.
  • Products that are not used for a long time shall be moisture-proof and dust-proof. Before use, they shall be debugged according to the above contents, and they can be put into operation only when they are normal.
  • This product has no isolation function. Please disconnect the front circuit breaker when maintaining circuit.
  • The maximum sustainable voltage of this device is 440V. In case of surge, this product will destroy itself without damaging your appliances. Your appliances will be safe.

Wiring diagramamiciSmart-220V-Under-Voltage-and-Over-Load-Protection-FIG-
\(2\)

Documents / Resources

| amiciSmart 220V Under Voltage and Over Load Protection [pdf] User Manual
220V Under Voltage and Over Load Protection, 220V, Under Voltage and Over Load Protection, Voltage and Over Load Protection, Over Load Protection, Load Protection, Protection
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals