ThermoPro TP961 Temperature Spike 150M Wireless Meat Thermometer User Guide

June 14, 2024
ThermoPro

TP961 Temperature Spike 150M Wireless Meat Thermometer

Truly Wireless Bluetooth
Meat Thermometer
Quick Start Guide

Aceording to the operating system of your mobile, scan the following QR code to download and install.

|
---|---
https://apps.apple.com/cn/app/tempspike/id1616090792| https://play.google.com/store/apps/details?id=com.rxt.thermopro

Introduction

Congratulations on your purchase  of a Smart, Wireless Bluetooth- connected Cooking Thermometer TempSpike. You will now be able 1o remotely monitor the internal food temperature and ambient temperature and how much time is left for the food to be done
from your smart device.

Features

  1. Booster: Receives the temperature signal from the probe and booster and transmits it to the smart device.  It also serves as apower source to charge the probe

  2. Probe: Inserted into meat and measures the internal temperature and ambient temperature, IP67 waterproof.

  3. ProbeBatteryPowerIndicator When it flashes quickly, it indicates the probe battery poweris low and needs to be recharged. When the probe is being charged, the light will flash slowly. After the probe is fully charged, the light il be off.

  4. Booster Battery Power Indicator: When it flashes quickly,this indicates the booster battery power is low and needs to replace batteries. probe and the booster are connected, the indicator will flash green slowly. If the probe loses connection with the
    booster, it il flash red slowly.

  5. When the probe is placed in the booster for charging and storage, the light wil be of

  6. Notch: When the probe is inserted into meat for measuring the meat’s internal temperature, the probe must be inserted deep enough so that the meat will cover this notch.

  7. S button: Serves 3 functions: Press once to silence the booster’s alarm when the meat temperature reaches the target temperature;
    Press and hold for 3 seconds to pair the booster and the probe;
    Press and hold for 10 seconds to reset the booster.

  8.   Sensors: Dual temperature sensors can monitor internal meat temperature up to 212°F (100°C) and ambient temperature up to 572°F(300°C) simultaneously

  9. Magnet: Two strong builtin magnets allow you 10 attach the booster onto your grill, oven, smoker or any other metal surface.

Components

1x Probe
1 x Booster
2 x AAA Batteries
1x Manual

Usage

Follow the simple steps below to set up your TempSpike and help you Cook Like a Pro!
Step 1: Download and install the “TempSpike” App. Scan the QR code above, or search for “TempSpike” on the Apple Store for i0S devices or on the Google Play Store for Android devices. Download the App and install it on your smart device.
Step 2: Enable Bluetooth on your smart device under the Settings section. If your smart device already has Bluetooth enabled, you can skip this step.
Step 3: Fully charge the probe Insert the batteries provided into the booster battery compartment with correct polarity as indicated and start to charge the probe. The probe battery indicator light will turn of once the probe is fully charged.
Step 4: air the probe to the booster The booster and the probe are pre- paired via Bluetooth at our manufacturing facility. Removing the probe from the booster, you will see the Connection Indicator begin to flash green slowly, this indicates that the booster and probe are paired.
If for any reason you need to re-pair them o you have a new probe or a booster to be paired, please follow the below steps:

  1. Remove the probe from the booster;
  2. Press and hold the § button until you see the Connection Indicator begin to flash green quickly;
  3. Wait for a few seconds until the Connection Indicator begins to lash green slowly. Once this occurs, this means the probe and the booster are successfully paired. Once they are paired, you do not need to pair them again for future uses.

Step 5 Pair the booster to your smart device

  1. Remove the probe from the booster;
  2. Launch the TempSpike App and press Add Device. A list of TempSpike devices will appear and select TempSpike from the list. The App wil jump to the device list page which shows the real time temperature measured by the probe. Now your TempSpike s ready for use. You don’t need to pair them again for future uses.

Step 6: Start Cooking

  1. Insert your probe into the meat deeply enough o that the notch on the probeis fully covered by the meat;
  2. Set your desired meat temperature or select the meat type and doneness you desire within the TempSpike App and/or set the highest/lowest ambient temperatures you prefer;
  3. Once the target temperature reaches your target temperature, an alarm will sound from the App and the booster.

caution

  1. There are sophisticated and delicate electronics within the probe. To avoid extremely high heat which could damage the electronics, please ensure to always insert the probe deeply enough into the meat so that the notch on the probe is fully covered by the meat.
  2. D0 NOT use TempSpike in the microwave.
  3. The connection range between the probe and the booster usually can go as far as 160 feet (S0 meters) in an open area, it can be dramatically reduced to as short as 10 feet (3meters) when the probe is inserted into the meat and then the metal cooking appliance is closed. Therefore, we strongly suggest placing the booster as close as possible to the probe whenit s inserted in the meat, such as resting directly outside the cooking appliance and always pay attention whether the Connection Indicator light flashes red which indicates the connection between the probe and the booster is lost. When this oceurs, please move the booster closer to the probe untilthe Connection Indicator light flashes green again.
  4. Always wear glove to remove the probe from the meat when you fnish cooking,
  5. Use a kitchen towel or rag to wipe and clean the probe after each use. Rinse the probe when it get back to normal temperature, please DO NOT rinse the probe when the temperature is stillhigh, it may damage the device.
  6.  After cleaning the probe, always place the probe in the booster for charging and storage.
  7. Do not immerse the booster in water.
  8. Place the booster at least 1 foot(30cm) away from the cooking appliance to avoid any potential damage from the heat,
  9. Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries. from different brands or with different capacities. The batteries should be removed from the unit if planning to store for more than four months.

* WARNING FOR ARTIFICIAL CARDIAC PACEMAKER USERS
Please be aware that a magnet installed inside the device may impact the functionality of your artificial cardiac pacemaker. If
You have a pacemaker, we recommend always staying up to 1 foot or 0.3 meter away from the device.

FCC Statement of Compliance

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.
    Warning: Changes or modifica tions to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmul interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmiulinterference to radio communications. However, there s no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference toradio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver,
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Declaration of Conformity

Hereby, the manufacturer declares that this product with the basic requirements and applicable regulations of the Radio Equipment Directive 2014/ 53/EU, the EMC Directive 2014/ 30/EU. The complete declaration of conformity can be found at. https://buythermopro.com/eu-declaration-of-conformity/.

Disposal of the Electronic Appliance

This electronic appliance should not be disposed of with normal household waste. Is of the unit atan approved facility or at your local recycling center. Please observe the current rules and regulations when disposing of the appliance. Contact your local
councilif in doubt.
8. Limited One-Year Warranty
TempSpike warrants this product 1o be free of defects in parts, materials and workmanship for a period of one year, from date of purchase.
Should any repairs or servicing under this warranty be required, contact Customer Service by phone or emailfor nstructions on how to pack and ship the product to TempSpike.
“This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Customer Service

Call or Text: 1-877-515:7797
(USA& Canada only)
33.975-129-576 (FR)
4921549319011 (DE)
39-052:317-15570 (IT)
34-910-601-787 (ES)
44-808164-1683 (UK)
61-180-057-7492 (AU)
Email: service@buythermopro.com
Hours: Weekdays 8:00AM- 8:00PM
EST (USA & Canada only)

Specification

Temperature Range:

Internal Temperature| 14°F to 212°F (-10°C to 100°C)
Ambient Temperature| 14°F to 572°F (-10°C to 300°C)
Tolerance| ±1.8°F (±1.0°C) from 14 to 212°F (-10 to 100°C), otherwise ±2%
Sensor Type| NTC
Transmission Range *:
Probe to Booster| 6.5Ft – 33Ft (2m-10m) depending on the oven/grill style
Booster to Smart device| 500Ft(150M)
Battery life:
Probe| 36 hours or more
Booster| 3 months or more
Wireless Technology| Bluetooth 5.2
Unit Size:
Probe|
Booster|
Power:
Probe| 2.4V (Built-in lithium rechargeable battery)
Booster| 3.0V( 2 x AAA Batteries)

  • The stated transmission range is based on tests at an ambient temperature of 77°F o 25°C without any obstructions or electromagnetic interference. Your range can vary depending on the number of obstructions and electromagnetic in your environment.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>