I. Product Introduction:
-
Start/reset: Press the RESET button to restart the clock and display the detection on every 0-9 digital screens.
-
Clock functions: Hours, minutes, temperature, humidity, date, week, and 12/24 hours system transformation.
-
Voice control function: Under the mode of power saving, when the close sound is greater than 60 decibels, the awaken display can appear; Voice control can also choose to light up half of the screen and all the screen
-
Three display modes: dp-1: Time or date and temperature displays in turn, humidity displays in default; dp-2: Keep the currently set display; dp-3: Only displays time, temperature and humidity
-
Alarm clock function: Three groups of daily alarm can be set
-
The brightness of LED screen automatically reduces in half: From 6 o’clock pm to 7 o’clock am, the brightness can be automatically reduced in half.
-
The temperature can switch in ℃ / ℉; The temperature measurement range: degree centigrade (0 ℃ to 50 ℃);
Degrees Fahrenheit (32 ℉ ~ 122 ℉) -
Humidity display range: relative humidity of 20% ~ 95%.
-
Working voltage: DC5V / 500 ma, or 4 sections of 7 battery (AAA)
II. The functions of the buttons/keys
- SET key: The function setting key, which is used to switch display time, date and three groups of alarm modes.
- UP button: Raising key; adjust the value of the regulating object up in the setting state. In normal mode: Press to switch the three display modes.
- DOWN button: The cutting key, in setting up state, adjust the value of the regulating object downward. In normal mode: Press to open or close the voice control function, long press to convert Celsius/ Fahrenheit.
- RESET button: RESET button.
III. Operation instructions:
-
The setting of time and alarm:
A. Time settings: In time mode, long press SET button to enter 12/24 model, 12/24 is flashing, then press UP/DOWN key to switch. Press the SET key once again to set the clock, the clock is flashing, press the UP/DOWN key to cooperate and adjust clock value; Then press the SET key, the minutes is flashing, press the UP/DOWN key again to adjust to minutes value, press SET key to complete time settings.
B. Date and alarm settings: In clock mode, short press the SET key to enter the date display. Then, long press SET button to enter date setting, the year is flashing, press the UP/DOWN key to cooperate and adjust the year; Press the SET key once again and the month is flashing, then press the UP/DOWN key to cooperate and adjust the month; Then press the SET key, the date is flashing, then press the UP/DOWN key to adjust the date/time, press SET key to complete date setting; Then press SET key twice to enter the A1 alarm time setting. Press UP key to set A1 “ON” or “-”. When setting “ON”, the alarm indicator lights up, which indicates that the alarm is on. When setting “-”, the alarm indicator is off, which shows the alarm is off. When entering the “ON”, the alarm setting is open, then long press SET key, the alarm clock is flashing, then press the UP/DOWN key to enter the alarm clock adjustment, press SET key again, the minutes is flashing, then press the UP/DOWN key to adjust the alarm minutes; A2 and A3 alarm can be set according to this method; Finally press STE settings to complete.
C. In the condition of time and temperature, press UP key to convert among the three modes of dP-1, dP-2, and dP-3:
dP-1 mode: LED screen automatically make circulation conversion among time, temperature, year and date, with temperature displaying for 10 seconds, the year and date showing for 5 seconds; after the completion of setting, it will return directly to the time mode.
dP-2 mode: Time is in default to be displayed. No matter what kinds of modes it will switch to, this mode will always be showed; after setting, the system will exit to this mode and keep the current state. Temperature and humidity will display in the same screen display and keep long bright.
dP-3 mode: Time is in default to be displayed. After the setting of each mode, the system will exit to the state of the model firstly, and then return to the time state after 15 seconds. Temperature and humidity will display in the same screen display and keep long bright.
D. In normal mode: Press the DOWN button to choose whether or not open power saving function (Open display: oNSd; Close display: – Sd); After opening the power saving function (Non setting state and non ringing alarm), the LED display will automatically shut down with no button operation for 30 seconds and enter into the power saving state, but the system still keeps walking. -
Temperature display settings:
The default display unit of temperature is for ℃ (degree centigrade). In normal mode, long press the DOWN button
can switch temperature unit between ℃ or ℉ mode; the temperature values are detected every 60 seconds. -
Voice control function:
A. After opening the power saving function, clap hands or make larger sound can open the LED display.
B. In acoustic control state, when the screen lights up, voice control can select the brightness of the screen (The semi-bright function can be adjusted again after lasting for 8 seconds) -
RESET button:
When operating error or some exception encounter, please power off and press the “RESET” button inside the battery tank to return the factory settings.
IV. Electric parameters:
-
Power adapter requirements: Input voltage: AC110V ~ AC240V, 50/60 HZ.
Output voltage: DC5V / 500mA ~ 1000mA -
The requirements of the chosen battery power supply: * 4 AAA batteries for backup (It is recommended to open the voice control function when using the battery power).
-
In acoustic mode, when the close sound is greater than 60 decibels, the display can be awakened.
-
The working temperature: 0 ℃ to + 50 ℃