KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack Installation Guide

June 15, 2024
Keystone

KEYSTONE logo

KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack

APPLICATION
Building mount for exterior illumination needs (including perimeter, pathways, loading docks, and general security lighting requirements)

SAFETY AND ELECTRICAL PARAMETERS

Warning

  • To reduce the risk of death, personal injury, or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards, read all warnings and instructions included with
    and/or the fixture box and fixture labels.

  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.

  • Commercial installation, service, and maintenance of luminaires should be performed by a qualified licensed electrician.

  • If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician. Please abide by all relevant country, regional, and local code requirements and regulations when installing this luminaire. Wiring must be in accordance with NEC and all applicable local codes.

  • Do not make or alter any holes unnecessarily in an enclosure of wiring or electrical components during the installation. Additional holes in the housing are permitted only for mounting hardware and must be properly sealed with silicone (not provided) in order to maintain watertight operation of the fixture.

Warning

  • Turn off electrical power at the fuse or circuit breaker box before wiring fixture to the building power.
  • Turn off the electrical power when you perform any maintenance.
  • Verify that supply voltage is correct by comparing it with the luminaire label information. Do not install with supply voltage that exceeds the rated input voltage of the luminaire.
  • All wiring connections should be capped with UL approved wire connectors.

Caution

  • Avoid direct eye exposure to the light source while it is on.
  • Account for small parts and destroy / recycle packaging material, as these may be hazardous to children.
  • Risk of Burn. Disconnect power and allow fixture to cool before handling / servicing.

Notice

  • All fixture installs must be properly grounded.

  • Minimum of 75C supply conductors.

  • Specifications and dimensions subject to change without notice. Consult Keystone with any questions or concerns.

  • Fixture is IP65 Rated: Suitable for wet location.

  • Ensure ambient operating temperature between –40ºC/–40ºF to 50ºC/122ºF is maintained. Exceeding these temperature ranges will void warranty and may reduce lifetime or cause performance issues.

  • Inspect fixture for any damages before installing. If there is any damage, please do not install and contact Keystone or authorized
    distributor for resolution.

  • Fixture should not be recessed. Housing must be mounted with lens facing towards the ground.

  • Fixture is intended for outdoor usage but should not be mounted less then 80″ from the ground.

ELECTRICAL SPECIFICATIONS

Catalog Number| Wattage| Lumens| CCT| Efficacy| CRI| Dimming| Input Voltage| Photocell| Housing Color| Rated Life| Legacy Equivalent
---|---|---|---|---|---|---|---|---|---|---|---


KT-WPLED35PS-M4-8CSB-VDIM

| 35W| 4550 lm| 3000K| 130 lm/W| >80| 0–10V| 120–277V| Included| Bronze| 50,000 hrs| ****

175W MH

25W| 4655 lm| 4000K| 133 lm/W
15W| 4620 lm| 5000K| 132 lm/W


KT-WPLED55PS-M4-8CSB-VDIM

| 55W| 7260 lm| 3000K| 132 lm/W| ****

250 W MH

45W| 7645 lm| 4000K| 139 lm/W
35W| 7370 lm| 5000K| 134 lm/W


KT-WPLED80PS-M4-8CSB-VDIM

| 80W| 10560 lm| 3000K| 132 lm/W| ****

320W MH

70W| 11280 lm| 4000K| 141 lm/W
55W| 10960 lm| 5000K| 137 lm/W
KT-WPLED120PS-L4-8CSB-VDIM| 120W| 17040 lm| 3000K| 142 lm/W| ****

400W MH

100W| 17640 lm| 4000K| 147 lm/W
80W| 16920 lm| 5000K| 141 lm/W

GENERAL SETUP INSTRUCTIONS

GENERAL WIRING DIAGRAM

KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack
1

Note: *In accordance with NEC-20 410.69 2022, all 0-10V negative wires have been updated from gray to pink. Please contact Keystone for details

POWER SELECT (WATTAGE) ADJUSTMENT
The Power Select dial for this fixture is located inside of the housing. To access the dial, open the fixture face (see below instructions for reference).This wall pack is selectable between 3 wattage options, and is preset to the highest option. Please see chart below for details.

COLOR SELECT (CCT) ADJUSTMENT
This fixture is equipped with Color Select technology. There is an adjustable dip switch behind the translucent knock-out (KO) cover to change CCT between 5000K, 4000K, and 3000K (see illustrations below). Fixture comes preset at 5000K unless otherwise noted.
Note: *Please turn off the power before adjusting the color temperature.

PHOTOCELL ENABLE / DISABLE
This fixture is equipped with a dusk-to-dawn photocell behind the translucent knockout (KO) cover. Adjust the dip switch to enable (ON) or disable (OFF) the photocell function (see illustrations below). Fixture comes preset with photocell enabled unless otherwise noted.

KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack
2

Catalog Number Selectable Wattage Preset Value

KT-WPLED35PS-M4-8CSB-VDIM

| 35W|

35W

25W
15W

KT-WPLED55PS-M4-8CSB-VDIM

| 55W|

55W

45W
35W

KT-WPLED80PS-M4-8CSB-VDIM

| 80W|

80W

70W
55W

KT-WPLED120PS-L4-8CSB-VDIM

| 120W|

120W

100W
80W

INSTALLATION INSTRUCTIONS

OPTION 1: Installation via Back Side Wiring of Junction Box

  1. Ensure that power is off before beginning installation.

  2. Open fixture by loosening 2 screws.

  3. Disconnect wiring to LED’s quick-connector and remove entire door assembly.(see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack 3

  4. Using a screwdriver, remove the 1/2″ threaded plug in the center of the junction box drilling template.

  5. Using the junction box drilling template on back of housing as a reference, drill out the appropriate holes that align with junction box accommodations on site (drilling template matches most standard junction box varieties).
    (see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall
Pack 4

  6. Attach an EVA foam pad to the outside of fixture housing where drilling template mates with junction box / building exterior.

  7. Thread input power wiring though the 1/2″ KO hole on back side of housing.
    (see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall
Pack 5

  8. Secure fixture to the building / junction box with suitable screws / hardware for the application, using the holes drilled in step 5. Ensure that EVA foam on back side of fixture is compressed, and that silicone is applied on top of drill / screw locations to maintain watertight operation.

  9. Complete wiring to input power wires (see General Wiring Diagram on page 2).
    (see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall
Pack 6

  10. Re-install the fixture door assembly and connect wiring from LED to power supply using quick-connector.

  11. Close the door assembly and tighten the 2 screws. Be sure fixture gasket is seated properly and fully compressed.(see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack 7

  12. Confirm that fixture is securely mounted to building exterior and then restore power to the fixture.

OPTION 2: Installation via Side / Bottom Wiring of 1/2″ Threaded Knock- Out

  1. Ensure that power is off before beginning installation.

  2. Open fixture by loosening 2 screws.

  3. Disconnect wiring to LED’s quick-connector and remove entire door assembly.(see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack 8

  4. Using a screwdriver, remove the 1/2″ threaded plug on the side of the junction box drilling template.

  5. Drill out the appropriate holes needed for proper lag bolt mounting near the corners of the backplate, based on suitable structural accommodations on site. A minimum of (4) bolts is recommend for proper security.
    (see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall
Pack 9

  6. Mark and drill appropriate holes in the building walls for lag bolt mounting.

  7. Secure fixture to the wall. Ensure that silicone is applied around bolt locations to maintain watertight operation.(see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack 10

  8. Thread input power wiring though the 1/2″ KO hole on side of housing.

  9. Complete wiring to input power wires (see General Wiring Diagram on page 2). Ensure that conduit entry to fixture is watertight, using Teflon tape or silicone sealant.
    (see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall
Pack 11

  10. Re-install the fixture door assembly and connect wiring from LED to power supply using quick-connector.

  11. Close the door assembly and tighten the 2 screws. Be sure fixture gasket is seated properly and fully compressed.(see illustrations below)KEYSTONE KT-WPLED35PS-M4-8CSB-VDIM Slim LED Wall Pack 12

  12. Confirm that fixture is securely mounted to building exterior and then restore power to the fixture.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>