Thermex Harwich Lux 90 cm Wall Black with Motor Instruction Manual

May 16, 2024
thermex

Thermex Harwich Lux 90 cm Wall Black with Motor

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
product

WARNINGS

  • The range hood is designed and manufactured according to DS/ EN 60335-1.
  • This range hood is only for use in private house holdings, if used for other purposes the warranty will be repealed.
  • Installation must be performed by a skilled electrician in accordance with the specifications given by Thermex Scandinavia A/S (Thermex) and legislation in force.
  • Thermex disclaims all responsibility in regards to damages caused by wrong installation, mounting or use.

BEFORE MOUNTING/COMMISSIONING

  • Inspect the range hood for transport damages, flaws and defects immediately after the receipt.
  • Transport damages must be filed to the haulage contractor and Thermex immediately after the receipt.
  • Flaws and defects must be filed to Thermex within 8 days the receipt, and not later than mounting/commissioning.

MOUNTING

  • The range hood is intended for working at 230 Volt ±10%~ 50 HZ in referring to EN 50160.
  • Connect the hood with the attached plug.
  • NOTE: The hood MUST have earth if the plug has an earth connection.
  • For models with external motor applies that NOT to use common zero by installing the hood and engine, as this will affect the control.
  • It MUST be ensured that the motor can be used with the selected range hood when using an external motor from another supplier. Otherwise the warranty no longer apply.
  • Do not plug in the range hood until the mounting is complete.
  • The air must not be discharged from the hood into a pipe used for extraction from devices using gas or other fuels. Such devices must have a separate vent.
  • The national legislation on air emissions must be observed.
  • Always use the original dimension of the vent. By reducing the dimension of the vent, the performance will be reduced and the sound level will be increased.
  • The vent to the open air, must be as short as possible in order to get the greatest possible capacity of the range hood.
  • The number of bends on the vent ought to be minimised, to gain the greatest possible capacity of the range hood.
  • Thermex recommends to always use sound and condensation insulated vent hose at the carrying through in unheated spaces.
  • Thermex recommends that there is used for a muffler to minimize the noise level when using flexible hose.
  • Using the flexible hose must always ensure that this is fully extended to minimize air resistance and thereby achieve maximum absorbency.
  • Different materials takes different rawlplugs and screws. Use rawlplugs and screws intented for the material the range hood is to be mounted in.
  • If the instructions for the installation of screws and fittings are not followed, it may result in electrical shock.
  • The minimum distance to gas stoves from the burner’s edge to the underside of the hood MUST be minimum 65 cm in accordance with EN 60335-2-31.
  • Thermex recommends that the space between the lower edge of the range hood and cooker is between 50 cm and 70 cm, valid for all cabinet range hoods, islands and wall mounted range hoods.
  • Always control the stated minimum distance between cooker and range hood in the manual for the cooker. If the manual for the cooker states a greater distance than what Thermex recommends the manual for the cooker MUST be followed.
  • Thermex recommends that the space between cooker and range hood does not exceed 3 meters for range hoods integrated in the ceiling.

Info

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-1

INSTALLATION WALLMOUNTED

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-8

INSTALLATION FREEHANGING

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
fig-9USE OF THE HOOD REMOTE CONTROL

  1. LED
  2. On/off light
  3. (+) button
  4. (-) button
  5. On/off extraction

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-10

The remote control uses a radio frequency system that enables the hood’s functions to be controlled up to a distance of 8 metres (this distance can be reduced if the signal is disrupted by a wall and/or furniture, or if the batteries are almost dead).
When a button is activated on the remote control, the LED will light on the remote control.
When using the remote control for the first time, the accompanying battery must be inserted first:

  • Remove the protective film that surrounds the battery.
  • Remove the battery cover on the bottom of the remote control by loosening the small clip.
  • Insert the battery. NOTE: take care to position the battery correctly.
  • Replace the battery cover on the remote control.
  • The remote control is now ready for use.

As a radio frequency system is used between the remote control and the hood, the two units must be coupled up to each other. The manufacturer has already coupled the hood up to the remote control when you receive it. The connection between the two units can however be lost, and must subsequently be coupled back together again.
This is done in the following steps

  • Ensure that the remote control is ready for use and the batteries are correctly inserted.
  • Switch off the mains power to the hood (it is not enough for the light and extraction on the hood are turned off).
  • Reconnect the power to the hood.
  • Click the “PAIR” button behind the battery cover on the remote. This must be done within 8 seconds of the power being reconnected to the hood.
  • If coupling is done correctly, the remote control will start to control the hood’s functions.
  • If the coupling fails, start the process again.

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-11

EXTRACTION

  • The motor is activated by pressing on ‘on/off extraction’.
  • The motor speed is increased by pressing on the (+) button and reduced by pressing on the (-) button.
  • The LED-indicator on the remote shows which extraction level the hood is currently on (step 1-4)

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-13

LIGHT

  • The light on the hood is turned on and off by pressing on the ‘on/off light’ button. This can be done independently of whether the motor is running.

CENTRAL VENTILATION

  • If the remote is used together with a hood connected to a central ventilation system, then the LED indicator show how long the extraction is activated for.

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-15

ELECTRICAL INSTALLATION

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-16

MAINTENANCE AND CLEANING

  • Always disconnect power before cleaning.
  • The hood must be cleaned regularly to ensure optimal operation and long service life.
  • Grease and dust debris are collected in the filter and may risk igniting with insufficient cleaning.
  • The hood should be cleaned inside and out frequently to avoid grease stains on walls or other surfaces.

DAILY CLEANING

  • For cupboard-integrated, free-hanging and wall-mounted hoods, Thermex recommends that the grease filter be wiped with a damp cloth after each cooking session. It requires very little effort every day to keep your cooker hood clean and effective.
  • Steel surfaces are cleaned with a damp cloth with detergent and treated with 3M Polish.
  • Lacquered surfaces should be cleaned with a damp cloth with detergent/washing-up liquid. Never use abrasives.

CLEANING THE GREASE FILTERS
Grease filters should be cleaned as needed. Thermex recommends as a minimum that the filter is cleaned at the following intervals, depending on the fat used for frying:

  • Frying margarine – filter cleaned every 3 weeks
  • Liquid margarine – filter cleaned every 2 weeks
  • Oil – filter cleaned once per week
  • Deep fat frying – filter cleaned 2-3 times per week

The grease filters are cleaned in the following way:

  • Open the glass door
  • Remove the grease filter behind the glass plate and the filter in the base by pulling on the filter-locking mechanism to loosen the filter from the hood.
  • Place the filters in warm soapy water and clean if necessary with a soft brush.
  • Rinse with warm water.
  • Leave the filters to dry on a dishcloth or similar.
  • Repeat the process if necessary.
  • Re-attach the filters..

The filters can also be washed in the dishwasher, although please note that machine washing can result in discolouration of the filters. Discolouration of the filters does not affect performance.
REPLACING THE RECIRCULATION FILTERS
If recirculation filters are used, these cannot be washed, but must be replaced when needed. Thermex recommends that the recirculation filters are replaced at least 2-4 times per year.

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-17

SERVICE

  • Before reporting service on your Thermex range hood, it is important that you read the installation and/or user instructions carefully. It ensures that
  • Thermex can provide you the best possible assistance.
  • Service department at Thermex can be contacted in preparation to:
  • Technical support for installation and installation of your range hood.
  • Clarification of functionalities in your hood.
  • Service Request during the warranty on your hood .

Before a service request during the warranty always try to disconnect the power to the hood for about 5 min. Then plug the power back on to see if the problem is corrected.
If the problem is not corrected, disconnect the power supply to the hood for one hour. If the hood is still not functioning properly, and the troubleshooting charts are reviewed, contact the service department.
NOTE: For inquiries within the warranty, you will be asked for proof of your purchase in the form of a sales receipt. Therefore, always store your sales receipt
Before the request for service within the warranty, it is important to have all the necessary information ready:

  • Error Description
  • Model
  • The type and serial number of the hood (on the chassis plate)
  • Information of puchase

WALLMOUNTED

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-18 Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
fig-19 Thermex-Harwich-Lux-90-cm-Wall-Black-
with-Motor-fig-20 Thermex-Harwich-Lux-90
-cm-Wall-Black-with-Motor-fig-21 Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
fig-22 Thermex-Harwich-Lux-90-cm-Wall-Black-
with-Motor-fig-23 Thermex-Harwich-Lux-90
-cm-Wall-Black-with-Motor-fig-24

FREEHANGING

Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-fig-25 Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
fig-26 Thermex-Harwich-Lux-90-cm-Wall-Black-
with-Motor-fig-27 Thermex-Harwich-Lux-90
-cm-Wall-Black-with-Motor-fig-28 Thermex-Harwich-Lux-90-cm-Wall-Black-with-Motor-
fig-29 Thermex-Harwich-Lux-90-cm-Wall-Black-
with-Motor-fig-30 Thermex-Harwich-Lux-90
-cm-Wall-Black-with-Motor-fig-31

ENVIRONMENTAL CONSIDERATIONS

PACKAGING
The packaging must be disposed of in accordance with local regulations on waste management.
SCRAPPING OF THE PRODUCT
The symbol on the product or accompanying documentation indicates that this product may not be disposed of as household waste but must be delivered to the nearest collection center for the recycling of electrical and electronic equipment.

CONTACT

THERMEX SCANDINAVIA A/S

THERMEX SCANDINAVIA S.L.U

THERMEX SCANDINAVIA AS

THERMEX SCANDINAVIA A/S

THERMEX SCANDINAVIA AB

THERMEX SCANDINAVIA A/S

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals