thermex IRP 280 V Electric Water Heater User Manual

June 10, 2024
thermex

IRP 280 V Electric Water Heater

Product Information: IRP 300 V (combi) PRO

The Thermex IRP (combi) PRO comes in three different sizes: 200,
280, and 300. The product is designed for home use and operates on
230/400 volts. The product has a maximum power output of 0.7 kW and
is designed to provide hot water for household use.

Product Usage Instructions:

  1. Ensure that the product is installed according to the
    instructions in the user manual.

  2. Connect the product to the water supply using the appropriate
    fittings (G3/4 or G1/2).

  3. Turn on the product by pressing the power button.

  4. Adjust the temperature to your desired level using the
    temperature control dial.

  5. Your hot water is now ready for use. Turn off the product when
    you are finished using it.

Please note that the product should be regularly maintained
according to the instructions in the user manual to ensure optimal
performance.

IRP 300 V (combi) PRO

RU
! «Thermex». !
.
! .
(, .). , , !
– , , .
, !
«!»
Thermex IRP (combi) PRO 200, 280, 300 . .

……………………………………….. 1 . ……………………….. 1 . 1/2″ ……………………………………………..2 . ……………………… 1 . …………………………………………………….1 .

( ) , , « ». .
3

TX_IM_603_03

RU

, min/max ­ ( ), , () 1 2

0,05 / 0,7 230/400 ~,
50 6 0,7 2 0,7 2 3/4″ IPX4 +3…+40 0 +18…+74 0 ±5 0

.
, (), . . ­ , ­ , ­ .

1. , !
2. , « » ().
3. :
, ; ;
;

4

RU
0,7 .
0,7 , 0,7 , , ( ) ( ) . ;
; ; , ; ; , (, ),
;
(). ; .
4. , , .
5. , , , , , , . , . , .
6. . 1 ­ 4 , .
7. , 16.09.2020 . 1479, , .
8. ( , , . .). , ,

, .
.
. , , , . ­ , , .
5

RU
, .
(), . , +74° (±5°). , , ( ) ( ) .
. +93° (±5°)
. .
3 : , , 6, 4 2 .

, .

, . . 1.
(. 1, . 4, 8) (, , , ).
(. 1, . 10) 3/4″ . , (10) 3/4″ ( ).
1/2″ ( ) , . (. 1, . 6, 11). , (6, 11) 1/2″ , (, .).
() , , . ( ) .
6

RU

, , , .

. 1. .

1 13

4

3 5

6 7 8 9 10 11 12
2

14

1. 2.
(G3/4, . ) 3.
(G3/4, . )
4. 1 5.
(G3/4, . ) 6.
(G1/2, . ) 7.
(G3/4, . )
8. 2 9.
(G3/4, . ) 10. (G3/4, . ) 11.
(G1/2, . ) 12.
(G3/4, . )
13. 14.

200 .
(. 1, 2).
!
, , . , . .
. , .
7

RU
, , , . , . .
! .
, .
( ) .
, , 100° . . .
, , , , 5 .

, .
! , !
. . , , , .

(. 2) .
.
8

RU
. : (2 ), (4 ), (6 ).

­ / 2 + 2 + 2

. 2. .

1 ­ I 2 ­ II 3 ­ III

IRP 200, 280, 300 V (combi) PRO

2

2

2

IRP 200 V (combi) PRO, IRP 280 V (combi) PRO, IRP 300 V (combi) PRO 6 . , . , (. 2). , +74° (±5°).
()
. , . , , . – – . .
: .
: – . .

9

RU

:
; ; ; ; ,
;
; , ,
;
; , . –
.

, , .

.

(-)

.

( )

.

, , (. 3),

10

RU
.
, , .

. 3. .

:

1. ; 2. , ; 3. : +10° +20°; 4. ;

.

, 9 . , , , , , .

11

RU

1 , :
( ) ­ 7 ;
( , , -, , , , ) ­1 .
. .
, -, .
. ( ) , . , :
, ,
,
,

, , , , . . , – ( ), , . .
, , .
! . ( ) , .
12

RU

«Heating Equipment» LTD « » 44, Moskovskoe Shosse, Tosno, Leningrad Region, 187002, Russia 187002, , ., . , , . 44
004/2011, 020/2011, 037/2016 RU C-RU.53..05547/22, 2014/35/U, 2014/30/U.
: .: 8 (800) 333-00-23 (- 09:00 20:00; , 10:00 18:00 ; ), e-mail: service@thermex.ru
­ , : , 196105, . -, . , . 63 .: 8 (800) 333-00-23
www.thermex.ru , :
, :
: «» 220029, . , . , . 22, 6, . 202 .: +375 17 3 800 200, +375 44 739 23 55 minsk@thermex.by, www.thermex.by
: .: +375 17 284 89 03
: « -» .: 8 (7212) 51 28 89
, , : « -» .: 8 (7212) 51 28 89
: ICS «Thermex MLD» SRL R. Moldova, MD-2023, Mun. Chisinau, str. Uzinelor 78, of. 403 Tel.: +373 (22) 81 77 58
13

RU – : «RE-SERVE» S.R.L. R. Moldova, MD-2001, Mun. Chisinau, bd. Gagarin 16 Tel.: +373 (22) 54 54 74 ii: «» .: 0 (800) 500 610 www.thermex.ua
1. / Sky blue / / 2. / Red / / 3. / Brown / / 4. / Black / / 5. – / Yellow- green / – / – 6. / Adjustable thermostat with safety
shutdown / / . 7. , 2 , 230 / THE 2 kW 230 V / , 2 , 230 / , 2 , 230 8. , 2 , 230 / THE 2 kW 230 V / , 2 , 230 / , 2 , 230 9. , 2 , 230 / THE 2 kW 230 V / , 2 , 230 / , 2 , 230 10. / EWH casing / / S1, S2, S3 ­ 16 , 250 / switch with 16 A, 250 V switching on indication / 16 , 250 / 16 , 250 14

/ Wiring diagram / ‘ / .

230 ~

N

1

7

L1 2

L

L2

11 12

3

21 22

31 32

L3

4

6

E 5

8
1 2 3 S1
9
1 2 3 S2

1 2 3 S3
10 L1 ­ 1 / phase 1 L2 ­ 2 / phase 2 L3 ­ 2 / phase 2 L (L1+L2+L3) ­ / phase (230 V~) N ­ / Neutral conductor / / E ­ / Earthing / /

N 1

L1 2
L2 3

L3

4

E 5

400 ~
7

11 12 21 22 31 32
6

8
1 2 3 S1
9
1 2 3 S2

1 2 3 S3
10 15

/ Warranty certificates /
/ Note of sale /
/ Model / / / Nr. seriei / / / Date of sale / / – / Dealer / – / , – / Service center indicated by dealer , – /
Stamp of dealer

/ Customer signature / /

/ Warranty certificates / /
1. / Model / / 2. / Serial no / / 3. / Date of sale / / 4. – / Dealer / – / 5. – / Stamp of dealer / /
6. – / Filled in by dealer / – /

1. Model 2. Serial No. 3. Date of sale 4. Dealer 1
1. Model 2. Serial No. 3. Date of sale 4. Dealer 2
1. Model 2. Serial No. 3. Date of sale 4. Dealer 3
1. Model 2. Serial No. 3. Date of sale 4. Dealer 4

6. Filled in by dealer 6. Filled in by dealer 6. Filled in by dealer 6. Filled in by dealer

5. Stamp of dealer 5. Stamp of dealer 5. Stamp of dealer 5. Stamp of dealer

1. / Date of acceptance / / 2. / Issue date / / 3. / Defect / / 4. / Executed work / / 5. / Specialist (name) / () / ( -) 6. / Stamp of service center / /

7. / Filled in by service center / / C

1. Date of acceptance 2. Issue date 3. Defect 4. Executed work 5. Specialist (name)
1. Date of acceptance 2. Issue date 3. Defect 4. Executed work 5. Specialist (name)
1. Date of acceptance 2. Issue date 3. Defect 4. Executed work 5. Specialist (name)
1. Date of acceptance 2. Issue date 3. Defect 4. Executed work 5. Specialist (name)

7. Filled in by service center 7. Filled in by service center 7. Filled in by service center 7. Filled in by service center

6. Stamp of service center
6. Stamp of service center
6. Stamp of service center
6. Stamp of service center

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals