thermex IF 50 H Comfort WIFI Platte Horizontale Boiler User Manual
- June 9, 2024
- thermex
Table of Contents
- DEAR CUSTOMER!
- APPLICATION
- MAIN TECHNICAL CHARACTERISTICS
- DESCRIPTION AND PRINCIPLE OF OPERATION
- SPECIFYING SECURITY MEASURES
- INSTALLATION AND CONNECTION
- ARRANGEMENT AND INSTALLATION
- CONNECTION TO WATER MAINS
- CONNECTION TO POWER SUPPLY
- OPERATION
- TECHNICAL MAINTENANCE
- POSSIBLE FAULTS AND REMEDIES.
- TRANSPORTATION AND STORAGE OF ELECTRIC WATER HEATERS
- DISPOSAL
- **MANUFACTURER’S WARRANTY
- **INFORMATION ON THE MANUFACTURER
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IF 50 H Comfort WIFI Platte Horizontale Boiler
User Manual
BEFORE THE FIRST USING YOUR ELECTRIC STORAGE WATER HEATER, CAREFULLY READ THIS OPERATION MANUAL
DEAR CUSTOMER!
Congratulations on your purchase of an electric water heater THERMEX. Water heaters THERMEX are designed and manufactured in strict accordance with domestic and international standards guaranteeing operation reliability and safety. Present manual applies to THERMEX models of IF (comfort) Wi-Fi. The full name of the model of your heater is specified in “Manufaturer’s warranty” section (sub -section “Note of sale”) and in the marking plate on the heater casing.
APPLICATION
Electric water heater (hereinafter referred to as the EWH) is designed to
provide with hot water for domestic and industrial facilities having a cold
water supply line pressure of not less than 0.05 MPa and not more than 0.7
MPa.
EWH shall be operated indoors in heated spaces and it is not designed for
operation in continuous flow mode.
2. SCOPE OF SUPPLY
Water heater | – 1 pcs. |
---|---|
Safety valve of GP type | – 1 pcs. |
Operation manual | – 1 pcs. |
Anchors for fastening (option) | – 1 set |
Packaging | – 1 pcs. |
MAIN TECHNICAL CHARACTERISTICS
EWH power supply shall be within the range of 230 V ± 10%. Supply network
frequency 50 Hz ± 1%. Volume of the inner tank and heating element power are
specified in the marking plate on the casing. Thread diameter in water inlet
and outlet pipes – G1/2 “.
The manufacturer reserves the right to make changes to the design, complete
set and specifications of the heater without prior notice.
Model| EWH useful volume, 1| Average heating time T = 45°
C at 2 kW| Installation
---|---|---|---
IF 30 V (comfort) Wi-Fi| 25| 0 h 39 min.| vertical
IF 50 V (comfort) Wi-Fi| 42| 1 h 06 min.| vertical
IF 80 V (comfort) Wi-Fi| 67| 1 h 45 min.| vertical
IF 100 V (comfort) Wi-Fi| 84| 2 h 12 min.| vertical
IF 50 H (comfort) Wi-Fi| 42| 1 h 06 min.| horizontal
IF 80 H (comfort) Wi-Fi| 67| 1 h 45 min.| horizontal
DESCRIPTION AND PRINCIPLE OF OPERATION
The outside casing of the EWH is made of impact-resistant plastic. Inner tanks
have a special bio-glass-porcelain coating reliably protecting the inner
surface against chemical corrosion. The space between the outside casing and
the inner tank is filled with polyurethane foam – a modern, ecologically clean
thermal insulation, which has the best heat-saving characteristics. IF
(comfort) Wi-Fi models have two screwed nozzles: for inlet of cold water
(Figure 1, p. 3) with a blue ring and for outlet of hot water (Figure 1, p. 2)
— with a red ring, and equipped with an additional drain connection (closed
with metal plug button) for draining the water and flushing the inner tank
(Figure 1, p. 17). The control panel, in all models, is on the front side of
the EWH. (Figure 1, p. 16).
Tubular heating element (THE), thermostat and thermal switch sensors are
mounted on the removable flange. THE is used to heat water and thermostat
provides with possibility of heating temperature regulation up to +65°С. All
models have electronic control with sensor adjustment. Electronics maintain
automatically water temperature at the level set by the user. The thermostat
is used for protecting against EWH overheating, which disconnects THE from
power supply when water temperature exceeds 95°С. (Fig. 3).
Safety valve (Fig. 1, p. 5) operates as the check valve, ensuring protection
of the water ingress from the water heater into the sewage system in case of
pressure drop in the sewage system and in case of pressure rise in the tank at
high water heating, as well as the functions of the safety valve, releasing
overpressure in the tank at high water heating. During water heater operation
water may leak out of the exhaust outlet pipe of the safety valve to relieve
excessive pressure, which is made for the purpose of water heater safety. This
outlet pipe shall remain open to the atmosphere and be installed constantly
down.
Drainage of water from the safety valve exhaust pipe into the drain shall be
pro- vided with installation of the corresponding EWH drainage. It is required
regularly (at least once a month) to discharge a small amount of water through
the exhaust pipe of the safety valve into the drain to remove lime deposits
and to test the operating functionality of the valve. Handle (Fig. 1, p. 15)
is intended to open the valve. It is necessary to control when operating water
heater this handle to be in position closing water draining from the tank.
SPECIFYING SECURITY MEASURES
Electrical safety and corrosion protection of EWH are guaranteed only if there
is an effective grounding in accordance with applicable electric installation
rules and regulations.
Plumbing pipes and fittings shall conform to parameters of water main and have
the required certificates of quality.
When installing and operating EWH the following is not allowed:
- To power EWH if EWH is not filled with water.
- To remove the protective cover when the power is on.
- Use EWH without grounding or use water pipes as grounding.
- To connect EWH to water supply with pressure exceeding 0.7 MPa.
- To connect EWH to the water supply without safety valve.
- To drain water from EWH with power switched on.
- To use spare parts not recommended by the manufacturer.
- To use water from the EWH for cooking.
- To use water containing impurities (sand, small stones), which might lead to EWH and safety valve breakdown.
- To modify design and installation dimensions of EWH brackets.
Ambient temperature shall be within the range of 3ºС to 40ºС. Water in
freezing EWH at negative temperatures results in malfunction, which is not a
warranty case.
Attention should be paid to children so that they do not play with EWH. EWH
is not intended for use by persons (including children) with limited physical,
sensory or mental capabilities, or by persons who do not know how to use the
EWH, except for cases when this happens under the supervision or instructions
by persons responsible for safety of the EWH.
During EWH operation, it shall be inspected regularly for proper health
(absence of dripping, burning smell, wiring sparks, etc.). In the case of long
interruptions in water heater operation, water supply failures, EWH shall be
disabled and cold water inlet valve shall be shut off.
INSTALLATION AND CONNECTION
All installation, plumbing and electrical works shall be performed by qualified personnel.
ARRANGEMENT AND INSTALLATION
All installation, plumbing and electrical works shall be performed by
qualified personnel.
EWH installation shall be performed in accordance with marking on the housing.
It is recommended to install EWH as close as possible to the place of hot
water using to reduce heat loss in the pipes.
When choosing the place of installation it should be taken into account the
total weight of EWH filled with water. Walls and floor with low carrying
capacity should be strengthened accordingly. When drilling (making) holes in
the wall consider cables, ducts and pipes in the wall.
EWH is suspended by brackets on hook anchors fixed in the wall. Hooks mounting
on the wall shall exclude spontaneous movement of EWH brackets along them.
The manufacturer bears no liability for EWH falling associated with improper
installation of anchors and their selection.
For EWH maintenance the distance from the protective cover to the nearest
surface in the direction of the removable flange axis shall be at least 30 cm
for all models.
In order to avoid damage of the user’s and/or third parties’ property in the
event of a faulty hot water system, it is required to install EWH in spaces
with waterproofing and drainage to the sewers, and in no case to place under
items exposed to the water under EWH. When placed in unprotected areas a
protective plate (not supplied) with rainage into sewers shall be installed
under the EWH.
In case of placing EWH in hard-to-reach places in order to perform maintenance
and warranty service (mezzanine floors, niches, ceiling voids, etc.),
installation and dismantling of EWH is carried out by the user on his own or
for his own account.
Note: safety tray is not included into the scope of EWH supply.
CONNECTION TO WATER MAINS
Cold water shall be supplied to EWH using pre-filter with water treatment
level not less than 200 µm.
Install pressure relief valve (fig. 1, p.5) at the cold water inlet (fig. 1,
p. 3) tube with the blue ring, by 3.5-4 turnings, ensuring junction tightness
with any sealing material (flax, FUM tape, etc.).
During EWH operation you can observe water leak out of the outlet pipe of the
safety valve for excessive pressure release to ensure safety of the water
heater. It is recommended to connect to a drainage hole a rubber or silicone
pipe of the relevant diameter for moisture removal.
Connection to the water supply line shall be carried out in accordance with
Fig. 1 using copper, plastic pipes or special flexible sanitary wiring. Do not
use any used flexible wiring. It is recommended to supply water to EWH through
filter installe d on thecold water main (not included in the scope of supply).
Do not use used flexible feed pipes. Do not operate the EWH without safety
valve or with valve made by other manufacturers. Figure 1. EWH
connection diagram to water supply
Figure 1: 1 – EWH, 2 – hot water pipe, 3 – cold water pipe, 4 – drain
valve (not in the scope of supply), 5 – safety valve, 6 – drainage (not in the
scope of supply), 7 – feed pipe, 8 – shut off valve when EWH operation, 9 –
cold water main, 10 – hot water main, 11 – cold water shut-off valve, 12 – hot
water shut-off valve, 13 – protective cover, 14 – exhaust pipe of the safety
valve, 15 – handle for opening pressure relief valve, 16 – control panel.
After connecting EWH make sure that cold water shut-off valve is open and hot
water shut-off valve (8) is closed. Open cold water tap in EWH (11), hot water
outlet valve (12) and hot water tap on mixer to ensure outflow of air from the
EWH. When the final EWH filling, water will continuously flow out of mixer
tap. When connecting EWH in places not provided with water supply it is
permitted to supply water in EWH from auxiliary tank using pumping station, or
from reservoir placed at a height of not less than 5 meters over the top of
EWH.
Note: for ease of maintenance during EWH operation it is recommended to
install drain valve (Fig. 1, p.4) in accordance with Fig. 1 (for models not
equipped with drainage pipe. (not in the scope of EWH supply)).
If the water pressure exceeds 0.7 MPa, at EWH cold water inlet, before the
safety valve (in the direction of water flow), the appropriate pressure
reducing valve (not supplied with the EWH) shall be installed to reduce water
pressure to standard.
CONNECTION TO POWER SUPPLY
Prior to the water heater connection to electrical network, make sure its parameters complies with the technical specifications of the water heater. ATTENTION! Prior to power activation make sure EWH is filled with water! Water heater shall be earthed to ensure safe operation. EWH is equipped with the stationary power cable (option) with Europlug (option). Power outlet shall have an earth terminal with the connected earthing wire and located in the area protected from moisture, or comply with the requirements not less than 1РХ4.
OPERATION
Figure 2. Electronic control board
Figure 2: 1 – LCD display, 2 – button «▲» Temperature control /
increasing the heating temperature, 3 – button «▼» Temperature control /
decreasing the heating temperature, 4 – button «on/off» / switch on/switch
off, 5 – button «Heating mode» / setting the heating power, 6 – “No Frost”
mode indication, 7 – indication «Economy» / minimum power, 8 – indication
«Optimal» / conventional power, 9 – indication «Turbo» / maximu m power, 10 –
Wi-Fi feature.
Switching on/switching off of the EWH is performed by pressing the central
button «on/off» (Figure 2, p. 4), while the display shows the preselected
heating temperature. After 2.5 seconds, the display shows the current water
temperature in the EWH. Selection of the heating power is performed by
pressing the button «Heating mode» (Figure 2, p. 5), on the control panel.
Mode 2 kW is accompanied by the indication of a control lamp «Turbo» (Figure
2, p. 9), 1,3 kW is accompanied by the indication of a control lamp «Optimal»
(Figure 2, p. 8), and 0,7 kW is accompanied by the indication of a control
lamp «Economy» (Figure 2, p. 7). Antifreeze mode is accompanied by the
indication of a control lamp «No Frost» (Figure 2, .6).
During the operation of the EWH, the user can adjust the temperature of the
water heating using two buttons «▲» «▼» Temperature control (Figure 2, p. 2
and p. 3). If you do not use the EWH in the winter time and there is a
possibility of freezing of the main waterways and the water heater itself, it
is recommended to turn off the power and drain the water from the EWH in order
to avoid damage to the inner tank.
For control from a mobile device water heater has Wi-Fi function.
- Install app “Thermex Home” from GooglePlay or AppStore. Create an account.
- On water heater panel press and hold buttons 2 and 3 together (Fig. 2). Appears Wi-Fi indication (Fig. 2, p. 10).
- In application “Thermex Home”:
-
click Add Device
-
from the drop list, select Water Heater
-
next follow the instructions of application.
Failures: -
make sure Wi-Fi function is enabled on your mobile device
-
make sure you are connected to the Internet
-
or contact your provider.
TECHNICAL MAINTENANCE
When performing maintenance scale on THE is checked. At the same time residue
that may accumulate in the bottom of the EWH is removed. If there is scale on
THE, it can be removed by using scale removing means or mechanically. It is
recommended to hold the first technical maintenance after a year from the time
of connection by experts
of a specialized organization and depending on intensity of scale and residue
to determine intervals of follow-up maintenance. This action will extend the
maximu m EWH service life.
The first replacement of the magnesium anode shall be made no later than 12
months from the date of EWH installation. In case of no mark of installation
in warranty certificate with the seal of installation company, the period is
calculated from the date of purchase. Regular periodic maintenance and annual
replacement of the magnesium anode in time is imperative to maintain the
manufacturer’s warranty. Replacement of the anode must be accompanied by a
mark in the warranty card in case of replacement by a service organization, or
an attached sales receipt for its p urchase in case of replacement by the
owner.
ATTENTION: accumulation of scale on TEH may cause its damage .
Note: Damages to THE due to scale formation are not subject to warranty.
Regular maintenance is not included in the warranty of the manufacturer and
the seller.
The following shall be carried out for maintenance:
- Turn off EWH power;
- Cool hot water or discharge it through the mixer;
- Cut off supply of cold water into EWH;
- Unscrew the relief valve or open drain valve;
- To put on the cold water supply inlet or discharge valve a rubber hose, sending the other end down the drain;
- Open hot water tap on mixer and drain water from the EWH through the hose;
- Remove the protective cover, disconnect wires, unscrew and remove from the casing the removable flange;
- Clean if necessary THEs from scale and remove residue from the tank;
- Assemble, fill the EWH with water and power on.
In models with drain pipe, it is enough to cut off the flow of cold water into
the EWH, unscrew the drain stub on drain pipe and open hot water tap. Once the
water is discharged, you can open for a while cold water supply in EWH for
additional tank washing.
When conducting EWH maintenance by forces of specialized organization mark
with the seal of organization performing maintenance shall be made in service
coupon.
POSSIBLE FAULTS AND REMEDIES.
Malfunction | Possible cause | How to fix |
---|
Hot water pressure from EWH decreased. Cold
water pressure keeps at the level.| Clogged inlet safety valve| Remove the
valve and clean it in water
Heating time increased| THE is covered with a layer of sludge| Remove the
flange and clean the THE
Supply voltage decreased| Contact power main operation ser- vice
Frequent tripping of thermal switch| The set temperature is close to the
limit| Set lower value of water heating temperature
Thermostat tube is coy- ered with sludge| Take out the EWH the remova- ble
flange and gently clean the
tube from scale
EWH operates but is not heating water| Valve (Fig. 1, p.8) is not closed or
out of or- der| Close or replace the valve (Fig. 1, p. 8)
Powered EWH does not heat water. No backlightsof indicator lamps.| 1) no
voltage in electric network;
2) damaged power cord.
3) Thermal switch actuated and not switched
on| 1) Check voltage at the electrical outlet;
2) Contact a qualified service center.
3) Disconnect from the power supply, remove EWH protective cover, press the
button on thermal switch until you hear a click (fig. 2) install the cover and
turn on the power
These faults are not defects of EWH and shall be fixed by the consumer or by a specialized organization at his own expense. In case of failure to fix problems using the above recommendations or in case of others problems revealing you should contact the authorized service center listed in the operation manual. Figure 2. Thermal switch arrangement diagram
TRANSPORTATION AND STORAGE OF ELECTRIC WATER HEATERS
Transportation and storage of electric water heaters shall be carried out in accordance with manipulation marks on the packaging:
need to protect the goods from moisture
fragile, delicate handling
recommended storage temperature range from +10° to +20° С
correct vertical position of cargo;
DISPOSAL
When complying with the rules of EWH installation, operation and maintenance
and when water quality complying with current standard the manufacturer sets
EWH lifespan of 9 years from the date of purchase.
All parts of the heater are made of materials allowing, where appropriate,
environmentally sound disposal which must be made in accordance with the rules
and regulations of the country where the water heater is operated.
When disposing of the EWH comply with local environmental laws and guidelines.
The manufacturer reserves the right to make changes to the design and
specifications of the heater without prior notice.
**MANUFACTURER’S WARRANTY
**
The manufacturer sets 2 years as the period of warranty for water heater.
The warranty period is calculated from the date of EWH sale. If there is no or
corrected date of sale and shop stamp, the warranty period is calculated from
the date of EWH
manufacture. Claims within the warranty period are accepted only on
presentation of the warranty card with marks of the s eller, and the
identification plate on the casing of the EWH. Release date of a water heater
is encoded in a unique serial number, located on the identification plate on
the casing. EWH serial number consists of thirteen digits. The third and
fourth digits of the serial number are year of manufacture, the fifth and
sixth digits – month of release, the seventh and eighth digits – day of EWH
release. Claims within the warranty period are accepted only on presentation
of the guarantee card with marks of the seller, and the identification plate
on the casing of the EWH. The warranty shall apply to EWH only. Responsibility
for compliance with principles of installation and connection shall be borne
by the buyer (in case of connection by his own) or by the installer carrying
out connection.
The first replacement of the magnesium anode shall be made no later than 12
months from the date of EWH installation. In case of no mark of installation
in warranty certificate with the seal of installation company, the period is
calculated from the date of purchase. Regular periodic maintenance and annual
replacement of the magnesium anode in time is imperative to maintain the
manufacturer’s warranty. Replacement of the anode must be accompanied by a
mark in the warranty card in case of replacement by a service organization, or
an attached sales receipt for its purchase in case of replacement by the
owner.
The manufacturer shall not be liable for defects due to violations of
principles of installation, operation and maintenance of EWH set forth herein,
including in cases where these defects have arisen due to invalid parameters
of mains (electricity and water), where EWH is operated, and due to the
intervention of a third party. Manufacturer’s warranty does not cover claims
for appearance of EWH.
**INFORMATION ON THE MANUFACTURER
**
Manufacturer:
THERMEX heating Technology (Jiangmen) CO., Ltd
No. 51, Jianshedonglu , Taoyuan town, Heshan City, Guangdong Province, China
ZIP: 529725
All models have been certified and comply with requirements of European
Directives.
NOTE OF SALE
Model ____ Serial No. _
Date of sale ____, 20 __ .
Dealer: _
Dealer’s representative
signature __
Dealer’s seal
The product is completed; I have no claims for the appearance of the product.
Operation manual with the necessary marks is received. I have read, understood
and accepted operation rules and warranty terms.
Customer’s signature: ___
WARRANTY CERTIFICATE 1
Model | Dealer’s seal | |
---|---|---|
Serial No. | ||
Date of sale | ||
Dealer |
To be filled by the dealer
ARRANTY CERTIFICATE 2
Model | Dealer’s seal | |
---|---|---|
Serial No. | ||
Date of sale | ||
Dealer |
To be filled by the dealer
Date of acceptance | Stamp of service center | |
---|---|---|
Issue date | ||
Defect | ||
Executed work | ||
Expert (full name) |
Filled in by service center
Date of acceptance | Stamp of service center | |
---|---|---|
Issue date | ||
Defect | ||
Executed work | ||
Expert (full name) |
Filled in by service center
WARRANTY CERTIFICATE 3
Model | Dealer’s seal | |
---|---|---|
Serial No. | ||
Date of sale | ||
Dealer |
To be filled by the dealer
WARRANTY CERTIFICATE 4
Model | Dealer’s seal | |
---|---|---|
Serial No. | ||
Date of sale | ||
Dealer |
To be filled by the dealer
Date of acceptance | Stamp of service center | |
---|---|---|
Issue date | ||
Defect | ||
Executed work | ||
Expert (full name) |
Filled in by service center
Date of acceptance | Stamp of service center | |
---|---|---|
Issue date | ||
Defect | ||
Executed work | ||
Expert (full name) |
Filled in by service center
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>