BougeRV B064 400W 12V 10BB Mono Solar Panel User Manual
- June 15, 2024
- BougeRV
Table of Contents
B064 400W 12V 10BB Mono Solar Panel
User Manual B ugeRV
Mono Solar Panel
Limitless energy, limitless life
Important
Thank you for choosing BougeRV Solar Panel.
Please read and understand the installation manual before installing BougeRV
Solar Panel. With proper operation and maintenance, this solar panel could
provide you with clean, renewable solar electricity for many years. This
manual contains important installation, maintenance, and safety information.
Retain this manual for future reference.
Limited Warranty
BougeRV Solar Panel comes with an 10year limited warranty that commences from
the date of purchase.We offer the following two types of limited warranty for
all BougeRV Mono Solar Panels:
1.10 years Material & workmanship warranty
2. 25 years Linear power output warranty
—-5 year 95% output warranty
—-10 year 90% output warranty
—-25 year 80% output warranty
If you have any questions during use, please feel free to contact BougeRV Tech
Support:
service@bougerv.com
www.bougerv.com
1-408-656-8402
1-669-232-7427
Note: If you have any after-sales questions about the BougeRV solar panel, please provide the barcode on the upper left corner of the solar panel, the appearance picture of the solar panel, with the test parameters (voltage and current) and operating environment of the solar panel. We will respond within 24 hours.
Before using the product, please carefully read the User Manual and the
product disclaimer. Once you use the product, it will be deemed that you have
understood, acknowledged, and accepted all the contents and terms of this
document. BougeRV hereby disclaims any liability for any losses caused by
users’ failure to use the product in accordance with the user manual. On the
premise of complying with laws and regulations, the company has the final
right to interpret the documents and the documents related to this product.
Ps: The limited warranties do not apply to any of the following:
The solar panel which in BougeRV’s absolute judgment have been subjected to
misuse, abuse, neglect or accident, alteration, or improper installation,
application, or removal. This includes, but is notlimited to, installation,
application,or removal by any party other than a BougeRV authorized dealer;
non-observance of BougeRV’s installation, user’s and/or maintenance
instructions; power failure surges, lightning, flood, fire, accidental
breakage, or other events beyond BougeRV’s control.
Safety Precautions
- Do not stand on, drop, scratch, or allow objects to fall on the solar panels as doing so may damage them and void the warranty.
- Do not place anything on the solar panel, even for a moment because the resulting residue may damage or stain the glass surface.
- lf the front glass is broken, or the back sheet is torn, contact with any panel surface or panel frame can cause electric shock.
- Broken J-boxes or connectors are electrical hazards as well as laceration hazards. Installers should remove any such solar panel from the array and contact BougeRV for disposal instructions.
- Do not install or handle the solar panel when they are wet or during periods of high wind.
- Do not block drain holes or allow water to pool in or near module frames.
- Unconnected connectors must always be protected from pollution (e.g dust, humidity, foreign particles, etc), prior to installation. Do not leave unconnected (unprotected) connectors exposed to the environment. A clean assembly environment is therefore essential to avoid performance degradation.
- Save these instructions!
Electrical Parameters
MODEL|
100W
SOLAR PANEL
|
200W
SOLAR PANEL(NEW)
|
300W
SOLAR PANEL
---|---|---|---
Peak Power Pm| 100W-±5%| 200W-±5%| 300W±5%
Open circuit voltage Voc| 21.4V±5%| 22.5V-±5%| 20.8V±5%
Max.power voltage Vmp| 18.15V±5%| 19.1V±-5°A| 17.5V±-5°A
Max.power current Imp| 5.51A±5%| 10.994±5%| 17.144±-5%
Short circuit current Isc| 6.114±5%| 12.21A±5%| 18.85A±5%
Solar cells Efficciency| 23%±5%| 23%±5%| 23%±5%
Operating temperature Limits| -40°F-4-185°F| -40°F-4-185°F| -40°F-+185°F
Cable/ Cable connector Model| 12AWG
3FT MC4 connectors| 12AWG 3FT MC4
connectors| 12AWG 3FT MC4
connectors
Max.static load, front(e.g.snow/wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.static load, back(e.g.,wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.hailstone impact (diameter/velocity)| 1.27g stell ball fall down from lm
height and 60m/s wind| 227g stell ball fall down from lm
height and 60m/s wind| 227g stell ball fall down from lm
height and 60m/s wind
Max.system voltage(V)| 1000V DC| 1000V DC| 1000V DC
Series fuse rating| 10A| 15A| 20A
Application Class| Class A| Class A| Class A
Product Certification /Standard| CE,ETL| CE,ETL| CE,ETL
Product diameter (mm)| 99554035| 148570535| 164088035
MODEL| 100W
SOLAR PANEL| 200W
SOLAR PANEL(NEW)| 300W
SOLAR PANEL
---|---|---|---
Peak Power Pm| 100W-±5%| 200W-±5%| 300W±5%
Open circuit voltage Voc| 21.4V±5%| 22.5V-±5%| 20.8V±5%
Max.power voltage Vmp| 18.15V±5%| 19.1V±-5°A| 17.5V±-5°A
Max.power current Imp| 5.51A±5%| 10.994±5%| 17.144±-5%
Short circuit current Isc| 6.114±5%| 12.21A±5%| 18.85A±5%
Solar cells Efficciency| 23%±5%| 23%±5%| 23%±5%
Operating temperature Limits| -40°F-4-185°F| -40°F-4-185°F| -40°F-+185°F
Cable/ Cable connector Model| 12AWG 3FT MC4 connectors| 12AWG 3FT MC4
connectors| 12AWG 3FT MC4 connectors
Max.static load, front(e.g.snow/wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.static load, back(e.g.,wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.hailstone impact
(diameter/velocity)| 1.27g stell ball fall down from lm height and 60m/s wind|
227g stell ball fall down from lm
height and 60m/s wind| 227g stell ball fall down from lm
height and 60m/s wind
Max.system voltage(V)| 1000V DC| 1000V DC| 1000V DC
Series fuse rating| 10A| 15A| 20A
Application Class| Class A| Class A| Class A
Product Certification /Standard| CE,ETL| CE,ETL| CE,ETL
Product diameter (mm)| 99554035| 148570535| 164088035
MODEL| 100W
SOLAR PANEL| 200W
SOLAR PANEL(NEW)| 300W
SOLAR PANEL
---|---|---|---
Peak Power Pm| 100W-±5%| 200W-±5%| 300W±5%
Open circuit voltage Voc| 21.4V±5%| 22.5V-±5%| 20.8V±5%
Max.power voltage Vmp| 18.15V±5%| 19.1V±-5°A| 17.5V±-5°A
Max.power current Imp| 5.51A±5%| 10.994±5%| 17.144±-5%
Short circuit current Isc| 6.114±5%| 12.21A±5%| 18.85A±5%
Solar cells Efficciency| 23%±5%| 23%±5%| 23%±5%
Operating temperature Limits| -40°F-4-185°F| -40°F-4-185°F| -40°F-+185°F
Cable/ Cable connector Model| 12AWG 3FT MC4 connectors| 12AWG 3FT MC4
connectors| 12AWG 3FT MC4 connectors
Max.static load, front(e.g.snow/wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.static load, back(e.g.,wind)| 2400 Pa| 2400 Pa| 2400 Pa
Max.hailstone impact (diameter/velocity)| 1.27g stell ball fall down from lm
height and 60m/s wind| 227g stell ball fall down from lm height and 60m/s
wind| 227g stell ball fall down from lm
height and 60m/s wind
Max.system voltage(V)| 1000V DC| 1000V DC| 1000V DC
Series fuse rating| 10A| 15A| 20A
Application Class| Class A| Class A| Class A
Product Certification /Standard| CE,ETL| CE,ETL| CE,ETL
Product diameter (mm)| 99554035| 148570535| 164088035
Electrical Connections
Series Connection
The panel may be wired in series to Lo, Loe, produce the desired voltage
output.
Parallel Connection
The solar panel can be wired in parallel to produce the desired current
output with the parallel .
Frequently Asked Questions
Q1 How to choose the appropriate solar accessories that fit the solar panel if | want to build a solar system on my own?
Q2 What should | do if the solar panel | received is damaged, missing parts, or no output?
Q3 What causes the low output power or no output during the use of solar panels? How can | solve it ?
The output power of solar panels is mainly affected by light intensity, light angle, and shadow occlusion during the use of solar panels. Therefore, during daily A3 use, the angle of illumination must be adjusted to prevent shadows, and the obstructions on the solar panel must be cleaned regularly, such as bird droppings, dust, and garbage. Such obstructions may cause the solar panel to not output at all.
(e2 = Does it works with the portable power station?
Yes, BougeRV solar panels with mc4 connectors are suitable for most portable A4 power stations on the market. If you want to inquire about the specific model, please contact us.
OUTDOOR APPLIANCES
www.bougerv.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>