Q-TRAN TORQ-FLAT Suspended Linear Lighting Fixtures Instruction Manual

June 15, 2024
Q-TRAN

INSTALLATION INSTRUCTIONS
LINEAR FIXTURE – TORQ Instruction Manual

TORQ-FLAT Suspended Linear Lighting Fixtures

ATTENTION: Please read all instructions BEFORE installation

  • Product to be installed by a licensed electrician – Field modifications void warranty
  • Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
  • Surface mount or recessed in millwork
  • Suitable for installation in storage area of a clothes closet when assembled as a finished fixture up to 4W/ft at Q-Tran facility
  • Not rated for walkover
  • Input Voltage: 24VDC
  • Diagrams for representation only and not to scale.

METHODS OF INSTALLATION: TORQ can be recessed in millwork with all compatible LED strips except SW-HE24/9.0. Surface Mounting Method

  • VHB Mount (page 5-6)

  • Silicone Mount (page 7)

  • Screw Mount (page 8)

  • Magnet Mount (page 9)

  • Low Profile Magnet Mount (page 10)
    Recessed Mounting Method

  • Magnet Mount : Millwork (page 11)

Cove, Under & over cabinet:
Ideal for office, retail, hospitality, education, laboratory, and residential. Shelf:
Ideal for office, retail, hospitality, education, laboratory, and residential. Display cabinet:
Ideal for retail and hospitality. Signage:
Ideal for lobby, retail, hospitality, institutional, and transportation.

COMPONENTS & HARDWARE

STAINLESS STEEL CLIP MAGNET CLIP LOW PROFILE MAGNET CLIP

ACCESSORIES SOLD SEPARATELY

MAGNET MOUNT ACCESSORY;
sold individually| HINGE BRACKET;
sold individually| Q-ANGLE;
sold in pairs| Q-PIVOT;
sold in pairs
---|---|---|---
| | |

LOW PROFILE MAGNET MOUNT ACCESSORY; sold Individually ADHESIVE SOLD SEPARATELY

SILICONE VHB TAPE; sold in 15’ increments

NOTES:
STAINLESS STEEL CLIP

  • 2 clips provided for 4’ or less; 4 clips provided for greater than 4’
    MAGNET CLIP

  • One magnet clip per foot

  • MMA-01/04 comes in 12” pieces; use at least one clip per MMA-01/04 accessory

  • MMA-01/04 can be cut into smaller pieces, if desired

CONTINUOUS WIRING CONFIGURATION OPTIONS

Review wire method to ensure clean installation prior to mounting extrusion.
NOTE: Additional wire methods include:
S1, S2, S3, S4: Connector/Wire Input only
P1, P2, P3, P4: Connector/Wire Input and Output

SURFACE MOUNTING METHOD

SURFACE PREPARATION Temperature and environmental concerns:

  • Ideal application environment is 70-100ºF in 50% humidity or less.
  • Minimum application temperature: 50ºF
  • This temperature and humidity should be maintained for 72 hours after application for maximum bond strength.

a. Using a 50/50 alcohol mix, thoroughly clean the backside of the Fixture and the surface area where Fixture will be installed.
Allow 5 minutes to dry.
b. Peel back 0.5″ of the VHB tape’s protective film on one end and use firm pressure to adhere it to the desired surface, avoiding air bubbles. Continue peeling the film and adhering the tape in small sections until the entire length is installed. For porous materials (Wood, Brick, Concrete etc.) apply two layers of paint or primer to the surface. This will help create a better bonding surface for these materials. These can be purchased from a local hardware store.

MATERIALS SUGGESTED EPOXIES
Concrete, Stone, Cinderblock, Metal, and Brick Loctite Metal and Concrete

Two-Part Epoxy
ABS, Fiberglass, Plastic, and PVC| Loctite Plastic Two-Part Epoxy
Tile, Wood, Ceramic, Glass, or Metal| Loctite Clear Two-Part Epoxy
All Purpose| Strong Stik

SURFACE MOUNTING METHOD: VHB ADHESIVE MOUNT
BEFORE installation, the surface must be thoroughly cleaned and dried for maximum bond strength. (page 5) Determine the TORQ fixture(s) location and positioning on desired surface before adhering Fixture to surface. Make any necessary reference markings to indicate fixture placement. a. To adhere the VHB adhesive, peel the white film back while evenly applying the tape to the mounting side of the fixture. The red side should be visible.
b. Remove the red film and position fixture in place according to your previous reference marking(s). Remove protective film from the surface of the fixture’s lens.
NOTES: EPOXY ALTERNATIVE: For improved bonding strength, apply a small amount of epoxy at each end. Refer to table on for suggested page 5 epoxies. These can be purchased at a local hardware store. Please follow all manufacturer instructions for suggested epoxy.
SURFACE MOUNTING METHOD: SILICONE

  • 2 clips provided for 4’ or less; 4 clips provided for greater than 4’

Determine the TORQ fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 24” – 30”. a. Firmly press the silicone-coated clips on the marked reference points.
b. Wait for silicone adhesive to cure completely before snapping fixture into place.
c. Snap fixture onto clips.
NOTE: Cure time is dependent on the type of silicone adhesive used.
Refer to silicone product manufacturer for accurate drying time. Remove protective film from the surface of the fixture’s lens.
SURFACE MOUNTING METHOD: SCREW MOUNT

  • 2 clips provided for 4’ or less; 4 clips provided for greater than 4’

Determine the TORQ fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 24” – 30”. a. Secure clips using the #4 flat head hardware provided.
b. Ensure the screw head is flush with the clip’s base.
c. Snap fixture onto clips.
NOTE: Flat head screw type is dependent on surface/application material.
Alternative flat head screws may be required. Refer to the surface material manufacturer for suggested screw type. Remove protective film from the surface of the fixture’s lens.
SURFACE MOUNTING METHOD: MAGNET MOUNT

  • One magnet clip per foot
  • MMA-01 comes in 12” pieces; use at least one clip per MMA-01 accessory
  • MMA-01 can be cut into smaller pieces, if desired

Determine the TORQ fixture(s) location and positioning on desired surface. Make any necessary reference markings to indicate where the magnet mount accessory bracket is to be secured in place. a. Mount the two #6 flat head screws into the 12” magnet mount accessory bracket through the slotted holes at each end. Ensure the screw head is flush with the magnet mount bracket.
b. Snap the magnet clips onto the backside of the fixture.
They should be offset to the accessory bracket screws to maximize magnetic connection.
c. Place the assembled fixture into the magnet mount bracket.
NOTE: If surface application requires a longer screw, the screw size must be a #6 Flat Head. Remove protective film from the surface of the fixture’s lens.
SURFACE MOUNTING METHOD: LOW PROFILE MAGNET MOUNT

  • One magnet clip per foot
  • MMA-04 comes in 12” pieces; use at least one clip per MMA-04 accessory
  • MMA-04 can be cut into smaller pieces, if desired

Determine the TORQ fixture(s) location and positioning on desired surface. Make any necessary reference markings to indicate where the magnet mount accessory bracket is to be secured in place.

a. Mount the two #6 flat head screws into the magnet mount accessory bracket through the slotted holes at each end. Ensure the screw head is flush with the magnet mount bracket.
b. Snap the magnet clips onto the backside of the fixture.
They should be offset to the accessory bracket screws to maximize magnetic connection.
i. If the clip does not fit securely onto the extrusion, apply the provided foam onto the inner face of the magnet clip.
c. Place the assembled fixture into the magnet mount bracket.
NOTE: If surface application requires a longer screw, the screw size must be a #6 Flat Head. Remove protective film from the surface of the fixture’s lens.
RECESSED MOUNTING METHOD: MILLWORK

  • One magnet clip per foot
  • MMA-01 comes in 12” pieces; use at least one clip per MMA-01 accessory
  • MMA-01 can be cut into smaller pieces, if desired
  • TORQ can be recessed in millwork with all compatible LED strips except SW-HE24/9.0

Determine the TORQ fixture(s) location and positioning on desired surface. Make any necessary reference markings to indicate where the magnet mount accessory bracket is to be secured in place.
NOTE: Depth of the channel in the millwork is dependent on overall height with the magnet clip and Magnet Mount Accessory. a. Mount the two #6 flat head screws into the 12” magnet mount accessory bracket through the slotted holes at each end. Ensure the screw head is flush with the magnet mount bracket.
b. Snap the magnet clips onto the backside of the fixture.
They should be offset to the accessory bracket screws to maximize magnetic connection.
c. Place the assembled fixture into the magnet mount bracket.
NOTE: If surface application requires a longer screw, the screw size must be a #6 Flat Head. Remove protective film from the surface of the fixture’s lens.

© 2023 Q-Tran Inc. All rights reserved
155 Hill St. Milford, CT 06460
203-367-8777
sales@q-tran.com
www.q-tran.com
Specification subject to change. Rev-09-13-23

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals