NEDLANDS GROUP ID8W-WF Smart WIFI Tuya User Guide
- October 30, 2023
- Nedlands Group
Table of Contents
NEDLANDS GROUP ID8W-WF Smart WIFI Tuya
Important Safety Instructions
Basic safety precautions should always be followed when installing, including the following:
- Read all instructions carefully before installation.
- Installation should be carried out only by a licensed electrician.
- IP54 rating is suitable for indoor use only.
- Ensure that the power is switched off and the fitting has cooled down before performing any maintenance, cleaning, changing the globe, or adjustment to the fitting.
- Ensure that no luminaire is installed near a heat source.
- Do not exceed the nominal supply voltage or amperage ratings.
- Ensure that power leads and screws are secure before connecting the power to avoid damage to the fitting.
Installation Instruction
The fitting has an insulating ceiling type IC-4 rating. Building materials and thermal insulation that can safely be exposed continuously to temperatures up to 90°C may abut and cover the luminaire. If the building material cannot meet this condition, the minimum clearance of 25mm is required. Refer to Figure 1 for installation spacing.
Fig 1: Installation Spacing
Tab 1: Ceiling cutout reference table.
Downlight dia (inch) | 2.5 | 3 | 4 | 6 | 8 |
---|---|---|---|---|---|
Ceiling Cutout (mm) | 70-75 | 90 | 120 | 160 | 190 |
Note: Before installation, check the IP label on the luminaire to choose the right place to install.
IP20/IP40 | Indoor use only, do not use in wet or damp place. |
---|---|
IP44/IP54 | Suitable for indoor areas including bathrooms and covered/sheltered |
areas such as porches.
IP65| Suitable for outdoor areas, not suitable for water immersion.
Note: Before installation, check the information of the driver as below.
Non-dim | Can not be used with any dimmer. |
---|---|
Triac dim | Compliable with recommended TRIAC dimmers, dimming range 8-100%. |
Installation Procedure
- Switch off before installation.
- Switch on only after complete installation and examination of the circuit.
- Professional electrician for installation and maintenance only.
- Risk of overheating or fire if the clearance distances are compromised.
|
Turn Off Power Supply
---|---
Turn off the power supply before starting any installation. Read instructions and check that you have all the tools and accessories to complete the installation correctly.
Downlight with internal driver
For products with a light color changeable button, select the light color (CW/NW/WW) before installation.
Light color changeable button
-
Cut a hole according to the cutout size of led downlight.
-
Use a screwdriver to open the driver terminal cover on the back of the downlight, feed the main AC wire L.N. in the terminal block respectively, then fix the cover back.
-
Hold back the spring clip then push the downlight into the hole.
-
Make sure the downlight is fixed tightly in the ceiling, turn on the power (Figure 1).
RISK OF FIRE – Required clearance from structural members and building
elements
SCB=25mm HCB=25mm
Warning:
Input wire diameter ≥0.75mm²;
Product modification and improper installation void the warranty!
Customer Support
Free Call: 1800 909 306
Website: nedlandsgroup.com.au
Email: sales@nedlandsgroup.com.au