LENNOX EL297UHV Gas Furnace User Manual
- June 13, 2024
- Lennox
Table of Contents
LENNOX EL297UHV Gas Furnace
Product Information
- Product Name: EL297UHV Series Gas Furnace
- Model Number: 508360-01
- Manufacturing Date: May 2023
- Manufacturer: Not specified
Product Usage Instructions
Installation and Service:
It is important to have the gas furnace installed and serviced by a licensed professional HVAC installer or equivalent, a service agency, or the gas supplier. Improper installation, adjustment, alteration, service, or maintenance can lead to property damage, personal injury, or loss of life.
Safety Warnings:
- Do not store or use gasoline or other flammable vapors and liquids near the furnace or any other appliance.
- Follow all safety warnings exactly to avoid serious injury, death, or property damage.
Gas Smell:
If you smell gas, follow these steps:
- Leave the area immediately.
- Do not operate any electrical switches.
- Do not use any phones in the building.
- From a safe location, call the gas company or emergency services.
Parts Identification:
The following parts can be found in the EL297UHV gas furnace:
- Top Cap
- Flue Collar
- Access Panel Combustion Air Inducer
- Integrated Control
- DuralokTM Heat Exchanger Assembly Air Intake Collar
- Burners
- Gas Valve and Manifold
- Pressure Switch Assembly
- Blower Motor
Notice to Homeowner:
- The furnace is equipped with safety devices that protect you and your property. If any of these devices are activated, the furnace operation will stop.
- If your home will be unattended for an extended period, periodically check the equipment operation.
- If leaving the home unattended is not possible, shut off thewater supply to prevent problems associated with a no heat condition (e.g., frozen pipes).
Performing Service or Maintenance:
- Before attempting any service or maintenance, turn off the electrical power to the unit at the disconnect switch.
- In case of overheating or gas supply failure, shut off the manual gas valve to the furnace before shutting off the electrical supply.
Flood-Damaged Furnace:
- Do not use the furnace if any part has been underwater due to flooding. It can be extremely dangerous.
- Contact a licensed professional service technician (or equivalent) to inspect the furnace and replace all wet gas controls, control system parts, and electrical parts, or replace the furnace if necessary.
Modifications and Conversions:
- Any additions, changes, or conversions required to meet specific application needs must be performed by a licensed professional installer (or equivalent) using factory-specified and approved parts.
Carbon Monoxide Poisoning Hazard:
- Ensure all openings in the outside wall around the vent and air intake pipes are sealed to prevent the infiltration of combustion products into the building.
- Check that furnace vent and air intake terminals are not obstructed throughout all seasons to avoid carbon monoxide poisoning.
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury or loss of life. Installation and
service must be performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
WARNING
FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Leave the building immediatly
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
Parts Identification
NOTE – This manual is the property of the homeowner and must be left with the equipment user.
Notice to Homeowner
This furnace is equipped with safety devices that protect you and your
property. If one or more of these devices is activated, furnace operation will
stop. If your home is left unattended for an extended period of time,
equipment operation must be checked periodically.
If this is not possible, the water supply to the house should be shut off and the pipes should be drained. This will prevent problems associated with a NO HEAT condition (frozen pipes, etc.)
CAUTION
Before attempting to perform any service or maintenance, turn the electrical
power to unit OFF at disconnect switch.
WARNING
- Do not set thermostat below 60°F (16°C) in heating mode. Setting thermostat below 60°F (16°C) reduces the number of heating cycles. Damage to the unit may occur that is not covered by the warranty.
- If overheating occurs or if gas supply fails to shut off, shut off the manual gas valve to the furnace before shutting off electrical supply.
- Do not use this furnace if any part has been underwater.
A flood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fire or explosion. Immediately call a licensed professional service technician (or equivalent) to inspect the furnace and to replace all gas controls, control system parts, and electrical parts that have been wet or to replace the furnace, if deemed necessary.
NOTICE
Any additions, changes, or conversions required in order for the appliance to
satisfactorily meet the application needs must be made by a licensed
professional installer (or equivalent) using factory-specified and approved
parts.
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, personal injury or loss of life. Installation and
service must be performed by a licensed professional installer (or
equivalent), a service agency, or the gas supplier.
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow instruction could result in severe personal injury or death
due to carbon monoxide poisoning, if combustion products infiltrate into the
building.
Check that all openings in the outside wall around the vent (and air intake)
pipe(s) are sealed to prevent infiltration of combustion products into the
building.
Check that furnace vent (and air intake) terminal(s) are not obstructed in any
way during all seasons.
Safety Instructions
- Keep the furnace area clear and free of combustible material, gasoline, and other flammable vapors and liquids. If it is installed in an insulated area, the furnace must be kept free of insulating material. Insulating material may be combustible.
- After any heavy snow, ice or frozen fog event, the furnace vent pipes may become restricted. Always check the vent system and remove any snow or ice that may be obstructing the plastic intake or exhaust pipes.
- DO NOT obstruct air flow to unit. Unit must receive an unobstructed flow of combustion and ventilating air. DO NOT block or obstruct air openings on the furnace or air openings to the area in which the furnace is installed. Take care to maintain established clearances surrounding the furnace.
- DO NOT store chlorine or fluorine products near unit or introduce these products into the combustion air. These products can cause furnace corrosion. 5 – DO NOT draw return air from a room where this furnace, or any other gas appliance (ie., a water heater), is installed. When return air is drawn from a room, a negative pressure is created in the room. If a gas appliance is operating in a room with negative pressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout the house by the furnace duct system.
WARNING
Blower access panel must be securely in place when blower and burners are
operating. Gas fumes, which could contain carbon monoxide, can be drawn into
living space resulting in personal injury or death.
Sharp edges.
Be careful when handling unit to avoid sharp edges which may result in
personal injury.
Your furnace is a gas appliance. It is critical that the gas supplied to the unit be completely burned to avoid the production of carbon monoxide gas. Complete combustion of the gas requires, but is not limited to, correct gas pressure and gas flow rate, adequate combustion, air, and proper venting.
WARNING
Carbon monoxide gas is invisible, odorless and toxic.
Exposure to carbon monoxide gas can cause personal injury and even death to
all occupants, including pets. Any item that is powered by or gives off heat
from a combustion process (including lawn mowers, automobiles, and fireplaces)
has the potential to produce carbon monoxide gas. Because of this, Lennox
recommends the use of a carbon monoxide detector in your home, even if you do
not own gas appliances. Reliable detectors are available at reasonable retail
prices. Contact your Lennox dealer for more details about this investment in
your safety.
Your furnace is designed to meet standards set by national agencies, and to
operate safely when properly installed and maintained. However, the unit’s
performance can be greatly impacted by the individual installation and the
operating environment. It is your responsibility to ensure that this appliance
is maintained. Proper maintenance is critical for your safety and the
satisfactory operation of the product.
Lennox strongly recommends annual inspection and maintenance of this
appliance. Contact your Lennox dealer for an inspection by a licensed
professional service technician (or equivalent).
DANGER
Danger of explosion.
There are circumstances in which odorant used with LP/propane gas can lose its
scent. In case of a leak, LP/propane gas will settle close to the floor and
may be difficult to smell. An LP/propane leak detector should be installed in
all LP applications. Do not attempt to bleed the gas lines of air. Call your
local gas provider.
Start-Up & Operation Information
WARNING
If you do not follow these instructions exactly,a fire or explosion may result
causing property damage, personal injury or death.
BEFORE PLACING THE UNIT INTO OPERATION, smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than
air and will settle on the floor.The gas valve on the EL297UHV will be
equipped with a gas control switch. Use only your hand to move the switch.
Never use tools. If the switch will not move by hand, do not try to repair it.
Call a licensed professional service technician (or equivalent). Force or
attempted repair may result in a fire or explosion.
Placing the EL297UHV furnace into operation:
EL297UHV units are equipped with an ignition system. Do not attempt to
manually light burners on this furnace.
Each time the thermostat calls for heat, the burners will automatically light.
The ignitor does not get hot when there is no call for heat on units with this
ignition system.
Operating the Gas Valve (Figure 2)
-
STOP! Read the safety information at the beginning of this section.
-
Set the thermostat to the lowest setting.
-
Turn off all electrical power to the unit.
-
This furnace is equipped with an ignition device which automatically lights the burners. Do not try to light the burners by hand.
-
Remove the upper access panel.
-
Move switch on gas valve to OFF. See figure 2.
-
Wait five minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you do not smell gas go to next step. -
Move switch on gas valve to ON. See figure 2.
-
Replace the upper access panel.
-
Turn on all electrical power to the unit.
-
Set the thermostat to desired setting.
NOTE – When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line. -
If the appliance will not operate, follow the section “Turning Off Gas to the Unit” and call your licensed professional service technician (or equivalent).
Turning Off Gas to the Unit
- Set the thermostat to the lowest setting.
- Turn off all electrical power to the unit if service is to be performed.
- Remove the upper access panel.
- Move switch on gas valve OFF.
- Replace the upper access panel.
Filters
All EL297UHV filters are installed external to the unit. Filters should be
inspected monthly. Clean or replace the filter(s) when necessary to ensure
proper furnace operation.
A filter must be in place when the unit is operating.
See table 1 for recommended filter sizes.
NOTE – Use replacement filters that are similar in size and efficiency ratings to those originally provided by the installing contractor. Use of replacement filters with higher filtration ratings may restrict air flow to the furnace. This may result in reduced unit efficiency, as well as premature blower motor failure.
TABLE 1
Furnace Cabinet Width | Filter Size |
---|---|
Side Return | Bottom Return |
17- 1/2” | 16 X 25 X 1 (1) |
21” | 16 X 25 X 1 (1) |
24- 1/2” | 16 X 25 X 1 (1) |
Maintenance
A licensed professional service technician (or equivalent) should inspect the complete system each season (heating and cooling). The following maintenance procedures should only be conducted by a licensed professional service technician (or equivalent). Do not attempt to service the unit in any way.
WARNING
ELECTRICAL SHOCK, FIRE,OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly could result in dangerous operation,
serious injury, death or property damage.
Improper servicing could result in dangerous operation, serious injury, death,
or property damage. Before servicing, disconnect all electrical power to
furnace.
When servicing controls, label all wires prior to disconnecting. Take care to
reconnect wires correctly. Verify proper operation after servicing.
Venting System
WARNING
Asphyxiation Hazard
The exhaust vent for this furnace must be leak-free and must be securely
connected to the furnace flue collar at all times.
For your safety and to fulfill the terms of the limited warranty, a licensed
professional service technician (or equivalent) must annually inspect this
furnace and its vent system.
Annually (before heating season) inspect furnace venting system, vent cap, heat exchanger, and burners for corrosion, deterioration, or deposits of debris. Remove any obstructions.
Inspect the furnace for obvious signs of deterioration.
- Inspect the furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage.
- Vent pipe must be clear and free of obstructions and must slope upward away from the furnace.
- Inspect the furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space containing the furnace.
- Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.
- Inspect the condensate drain and trap for leaks and cracks. The drain and trap must also be cleaned and the trap must be filled with water.
- During a seasonal check the service technician will conduct a combustion analysis. The technician will also inspect the indoor blower, burner flames, electrical connections and the venting system.
Blower
Check the blower wheel for debris and clean if necessary.
The blower motors are prelubricated for extended bearing life. No further
lubrication is needed.
WARNING
The blower door must be securely in place when the blower and burners are
operating. Gas fumes, which could contain carbon monoxide, can be drawn into
the living space resulting in personal injury or death.
Burner Flame
CAUTION
To ensure proper operation, a licensed professional service technician (or
equivalent) should check the burner flame and conduct a combustion analysis
annually.
Electrical
- Check all wiring for loose connections.
- Check for the correct voltage at the furnace (furnace operating).
- Check amp-draw on the blower motor
Motor Nameplate__Actual__
Service Reminder
Call your Lennox service technician if the unit will not operate.
Before calling, always check the following to be sure service is required:
- Check that electrical disconnect switches are ON.
- Check room thermostat for proper setting.
- Replace any blown fuses or reset circuit breakers.
- Gas valve should be ON.
- Air filter should not be plugged, which will limit air flow.
- Is gas turned on at meter?
- Is manual main shut-off valve open?
Record the model and serial number of the furnace. These numbers are on the
unit nameplate, which is located on the blower deck below the combustion air
inducer.
Serial Number __
Model Number __
Safety Precautions
If you discover any of the following, shut down your unit, and contact a Lennox dealer for an inspection by a licensed professional service technician (or equivalent).
-
If you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a problem.
For example, poorly performing burners can produce unfamiliar noises. -
If you smell any unusual odors, your unit may be operating improperly. For example, units can give off unfamiliar odors if components are required to operate in abnormal conditions.
-
Look for visible signs of a malfunctioning unit. Examples include unusual amounts of condensate on windows inside your house, visibly burnt components or unusual dirt or rust accumulations on the vent pipe or in the unit.
-
If you experience headache, nausea, fatigue, or dizziness, the cause could be exposure to carbon monoxide gas. This is often misdiagnosed as the flu because symptoms are similar. If you suffer from flu-like symptoms that are exaggerated at home, but seem to subside while you are away from the house, exposure to carbon monoxide could be the cause.
Your vigilance may pay off in early detection of a problem before either
personal injury or property damage occurs.
Do not hesitate to contact a qualified service technician as an investment in
your well being.
Planned Service
Annual Furnace Maintenance
At the beginning of each heating season, and to comply with the Lennox Limited
Warranty, your system should be checked as follows by a licensed professional
service technician (or equivalent).
-
Check wiring for loose connections, voltage at indoor unit and amperage of indoor motor.
-
Check the condition of the belt and shaft bearings if applicable.
-
Inspect all gas pipe and connections for leaks.
-
Check the cleanliness of filters and change if necessary (monthly).
-
Check the condition and cleanliness of burners and heat exchanger and clean if necessary.
-
Check the cleanliness of blower assembly and clean the housing, blower wheel and blower motor if necessary.
-
Inspect the condensate drain and trap for leaks and cracks. The drain and trap must also be cleaned and the trap must be primed with water. Inspect the rubber hoses connected to the pressure switches for cracks or loose connections, replace as necessary.
- Remove the rubber hoses from the cold end header box and inspect for any blockage, clean as needed.
- If strainers are installed in the hoses remember to remove and clean before reinstalling the hoses.
-
Evaluate the heat exchanger integrity by inspecting the heat exchanger per the AHRI heat exchanger inspection procedure. This procedure can be viewed at www.ahrinet.org
-
Ensure sufficient combustion air is available to the furnace. Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) must be properly sized, open and unobstructed to provide combustion air.
-
Inspect the furnace intake and exhaust pipes to make sure they are in place, structurally sound,without holes, blockage or leakage and the exhaust pipe is sloped toward the furnace. Inspect terminations to ensure they are free of obstructions and are structurally sound. Inspect the furnace return air duct connection to ensure the duct is sealed to the furnace. Check for air leaks on supply and return ducts and seal where necessary.
NOTE – After any heavy snow, ice or frozen fog event the furnace vent pipes may become restricted. Always check the vent system and remove any snow or ice that may be obstructing the plastic intake or exhaust pipes. -
Inspect the furnace return air duct connection to ensure the duct is sealed to the furnace. Check for air leaks on supply and return ducts and seal where necessary.
-
Check the condition of the furnace cabinet insulation and repair if necessary.
-
Perform a complete combustion analysis during the furnace inspection to ensure proper combustion and operation. Consult Service Literature for proper combustion values.
-
Verify operation of CO detectors and replace batteries as required.
Perform a general system test. Turn on the furnace to check operating functions such as the start-up and shutoff operation.
- Check the operation of the ignition system, inspect and clean flame sensor. Check microamps before and after. Check controls and safety devices (gas valve, flame sensor, temperature limits). Consult Service Manual for proper operating range. Thermal Limits should be checked by restricting airflow and not disconnecting the indoor blower. For additional details, please see Service and Application Note H049.
- Verify that system total static pressure and airflow settings are within specific operating parameters.
- Clock gas meter to ensure that the unit is operating at the specified firing rate for each stage of operation. Check the supply pressure and the manifold pressure on both low fire and high fire. If manifold pressure adjustment is necessary, consult the Service Literature for unit specific information on adjusting gas pressure. Not all gas valves are adjustable. Verify correct temperature rise.
Repair Parts List
The following repair parts are available through Lennox dealers. When ordering parts, include the complete furnace model number listed on the CSA International nameplate — Example: EL297UHV045P36B. All service must be done by a licensed professional installer (or equivalent), a service agency, or the gas supplier.
- Cabinet Parts
- Outer access panel
- Blower access panel
- Top Cap
- Control Panel Parts
- Transformer
- Integrated control
- Door interlock switch
- Blower Parts
- Blower wheel
- Motor
- Motor mounting frame
- Blower housing cutoff plate
- Heating Parts
- Flame Sensor
- Heat exchanger assembly
- Gas manifold
- Combustion air inducer
- Gas valve
- Main burner cluster
- Main burner orifices
- Pressure switch
- Ignitor
- Primary limit control
- Flame rollout switches